• 제목/요약/키워드: Combined system

검색결과 5,700건 처리시간 0.03초

관류형 증기발생기를 사용한 복합발전용 초임계압 하부시스템의 성능 설계해석 (Performance Design Analysis of the Supercritical Pressure Bottoming System of Combined Cycle Power Plants Using Once-Through Steam Generator)

  • 양진식;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1370-1377
    • /
    • 2002
  • This study analyzed the design performance of the bottoming system of combined cycle power plants using a once-through heat recovery steam generator. For a parallel arrangement of the main heater and reheater, parametric analyses were carried out to present the criteria for determining the reheater pressure and the location of the starting point of the reheater in the HRSG. The performance of the bottoming system was presented fer a range from high subcritical to supercritical pressure. The steam turbine power is as high as that of conventional triple-pressure bottoming systems. The serial arrangement of heat exchangers with division of each heater into several segments can achieve similar power level.

시스템 식별법에 의한 복합 부하 모델링 (The Combined Load Modeling based on the System Identification)

  • 심건보;김주락;오임걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.260-264
    • /
    • 2007
  • Many load modeling concepts have been proposed in the past. Efforts of load modeling may be summarized into three approaches ; the first one is to find an aggregation of various different load components scattered and distributed in an area. The second one is to find parameters to represent load from field tests, if any. And the third one is how to present the load of motor components could be represented. This paper proposes a system identification of combined load modeling to cover the second approach. In this paper, an improved method of system identification is suggested for the combined load model (dynamic and static load model) in which parameters of the equivalent induction motor. polynomial type load and their compositions.

  • PDF

다양한 경계조건에서 원판이 결합된 원통 셸의 고유진동 해석 (Analysis of Free Vibration of a Cylindrical Shell with a Circular Plate Under Various Kinds of Boundary Conditions)

  • 임정식;손동성
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.936-948
    • /
    • 1998
  • A theoretical formulation for the analysis of free vibration of a cylindrical shell with a circular plate attached at an arbitrary axial position of the shell under various kinds of boundary conditions was derived and programed to get the numerical results for natural frequencies and mode shapes of the combined system. The boundary conditions of the shell to be considered here are clamped-free, clamped-simply supported, both ends clamped and both ends simply supported. The frequencies and mode shapes from theoretical calculation were compared with those of commercial finite element code, ANSYS. The results showed good agreement with those of ANSYS in frequencies and mode shapes. The program will contribute to the design optimization of a shell/plate combined system through the analysis of natural frequencies and mode shapes for the system.

  • PDF

연료전지용 스크롤 팽창기-압축기 성능해석 (Performance Analysis of a Combined Scroll Expander-compressor unit for a Fuel Cell System)

  • 김성준;안종민;김현진
    • 동력기계공학회지
    • /
    • 제13권3호
    • /
    • pp.11-19
    • /
    • 2009
  • This paper introduces a conceptual design of a combined scroll expander-compressor unit for a fuel cell. Since air discharged out of the fuel cell stack has still high pressure energy, some power can be extracted from the air by directing it to pass through an expanding device. Such extracted power can be used to drive an auxiliary compressor. For this purpose, a scroll type expander coupled to a scroll type compressor was designed for a 1kW-class fuel cell. The orbiting scroll members of the expander and the compressor were made to share three of common drive shafts installed in the mid frame plate. Performance analysis for the combined expander-compressor unit showed that the installation of this unit could reduce the auxiliary power consumption in the fuel cell by about 42%.

  • PDF

다중수원 수처리 의사결정에 관한 실험적 연구 (An experimental study on decision making for multi-source water)

  • 정정우;조형락;이상호;채수권
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2015
  • A combined treatment system using multiple source water is becoming important as an alternative to conventional water supply for small-scale water systems. In this research, combined water treatment systems were investigated for simultaneous use of multi-source water including rainwater, ground water, river water, and reclaimed wastewater. A laboratory-scale system was developed to systematically compare various combinations of water treatment processes, including sand filtration, microfiltration (MF), granular activated carbon (GAC), and nanofiltration (NF). Results showed that the efficiency of combined water treatment systems was affected by the quality of feed waters. In addition, a simply approach based on the concept of linear combination was suggested to support a decision-making for the optimum water treatment systems with the consideration of final water quality.

전력기기 내환경특성평가를 위한 복합가속열화시스템 제작 (The Combined Testing System for Simulating Condition of Acceleratedly Deteriorated Environment)

  • 이정기;김민규;김익수;정주영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.182-183
    • /
    • 2006
  • It has been studied about the important consideration in designing and construction of the reliability assessment facilities including the combined testing system for simulating condition of acceleratedly deteriorated environment, which enable to test and evaluate the large-sized HV power apparatus without any disassembly up to transmission class in this paper. Also it is described simply about its ratings and main technical specifications and trial running of the system. To evaluate the performance characteristics against combined test condition for various power installation, especially for the polymer type insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

인터리브드 풀브릿지 컨버터와 하프브릿지 인버터를 결합한 연료전지 발전 시스템 (Fuel Cell Generation System Combined Interleaved Full-bridge Converter with Half-bridge Inverter)

  • 김헌희;이희준;신수철;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.518-519
    • /
    • 2012
  • This paper suggested a fuel cell generation system which combined interleaved full-bridge converter with half-bridge inverter. High ratio step-up converter is essential to use the power as general voltage source. Full-bridge converter has high efficiency and can boost the input voltage to high output with transformer. With series connected capacitors, interleaved full-bridge converter and half-bridge inverter are combined. Half-bridge inverter has two fewer switches compared to full-bridge type. Also, switching loss can be reduced. The performance is verified through simulation with 1.5[kW] fuel cell generation system.

  • PDF

유비쿼터스 데이터 웨어하우스: RFID와 다차원 온라인 분석의 통합 (Ubiquitous Data Warehosue: Integrating RFID with Mutidimensional Online Analysis)

  • 조대연;이승표
    • 한국IT서비스학회지
    • /
    • 제4권2호
    • /
    • pp.61-69
    • /
    • 2005
  • RFID is used for tracking systems in various business fields these days and these systems brought considerable efficiencies and cost savings to companies. Real-time based information acquired through RFID devices could be a valuable source of information for making decisions if it is combined with decision support tools like OLAP of a data warehouse that has originally been designed for analyzing static and historical data. As an effort of extending the data source of a data warehouse, RFID is combined with a data warehouse in this research. And OLAP is designed to analyze the dynamic real-time based information gathered through RFID devices. The implemented prototype shows that ubiquitous computing technology such as RFID could be a valuable data source for a data warehouse and is very useful for making decisions when it is combined with online analysis. The system architecture of such system is suggested.

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

발아현미, 배양산삼 및 용안육 혼합 제제가 Pentobarbital로 유도된 수면시간에 미치는 영향 (Effects of the Combined-Preparation of Germinated Brown Rice, Cultured Mountain Ginseng and Longanae Arillus on Pentobarbital-induced Sleeping Time)

  • 오석흥;오기완;조형권;은재순
    • 동의생리병리학회지
    • /
    • 제24권4호
    • /
    • pp.598-601
    • /
    • 2010
  • This experiment was performed to investigate whether the combined-preparation of water extracts of germinated brown rice (WGR), water extracts of cultured mountain ginseng (WCG) and 70% ethanol extracts of Longanae Arillus (ELA) has hypnotic effects and/or enhances pentobarbital-induced sleep behaviors through the GABAergic system. The combined-preparation of WGR and WCG reduced sleep latency and prolonged sleep time induced by pentobarbital. ELA also reduced sleep latency and prolonged sleep time induced by pentobarbital. However, WGR or WCG itself did not induce sleep. The combined-preparation of WGR, WCG and ELA strongly reduced sleep latency and prolonged sleep time via chloride influx into primary cultured cerebellar granule cells. In conclusion, the combined-preparation of WGR, WCG and ELA augments pentobarbital-induced sleep behaviors through the modification of GABAergic system.