• Title/Summary/Keyword: Combined sewer

Search Result 147, Processing Time 0.024 seconds

Estimation of Solid Deposition in Sewer Systems using MOUSE Model (MOUSE 모형을 이용한 관거 내 고형물 퇴적량 산정)

  • Lee, Jae-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.5
    • /
    • pp.397-407
    • /
    • 2007
  • The deposition of sewer solids during dry weather in combined sewer systems results in a loss of flow capacity that may restrict flow and cause a local flooding and enhanced solids deposition. In order to solve these problems and to manage sewer systems efficiently, development of estimation equations for solid sediments In sewer systems is needed. However, estimation of solid sediments has performed using specific methods such as computer model before the development of estimation equations. In this study, solid sediments in sewer systems were estimated using MOUSE model for Gunja drainage basin in Korea and the estimated results were verified using estimation equations developed by the U.S. Environmental Protection Agency. As results, the estimated values using MOUSE model are smaller than that of equations developed in 1977 but greater than that of equations developed in 1984. Although the comparison between simulated and measured solid deposition is difficult due to the absent of measurement data, the estimated values using MOUSE model is reliable and can be used to develop estimation equations for solid sediment in Gunja drainage basin.

A Post-Implementation Assessment of the Effectiveness of a Separate Sewer System in Improving River Water Quality

  • Reyes, Nash Jett;Geronimo, Franz Kevin;Guerra, Heidi;Choi, Hyeseon;Jeon, Minsu;Kim, Lee-Hyung;Ku, Jin Hye;Jun, Kyung Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.241-241
    • /
    • 2021
  • Recent developments recommend the use of SSS to prevent combined sewer overflows and reduce excessive pollutant deposition in the receiving waters; however, other studies also suggest that SSS have minimal or no advantage over CSS in terms of reducing the pollutant loads being discharged in natural waterways. This study was conducted to evaluate the effectiveness of employing SSS in improving the water quality of the rivers in Okcheon-gun, South Korea. The former combined sewer outfalls (CSOs) were monitored to determine the presence of illicit connections or leaks in the newly-established SSS. Dry and wet-day monitoring was conducted alongside the collection of water samples on 14 points along the reach of the rivers and four former CSOs to determine water quality changes and patterns of pollutant loading. Among the 34 former CSOs in the study area, eight former CSOs exhibited dry-day discharges, implying the possibility of having illicit connections, leaks, or illegal wastewater discharge in the system. Moreover, relatively high biochemical oxygen demand (BOD) chemical oxygen demand (COD) concentrations, ranging from 4.8 mg/L to 24.9 mg/L and 6.4 mg/L to 10.1 mg/L, respectively were observed on three out of the four monitored CSOs. Fluctuations in the pollutant concentrations in the different monitored points along the river was also observed due to the presence of pipes discharging polluted water. Ultimately, further studies are necessary to identify the sources of dry-day discharges in the CSOs to successfully improve the water quality of the rivers in the area.

  • PDF

Set up Reduction Goals of Combined Sewer Overflow Pollutant Load Using Long-Term Rainfall-Runoff Model Simulation (장기간 강우-유출 모의를 통한 합류식하수관로시스템의 월류부하량 저감목표 설정 연구)

  • Lee, Gunyoung;Na, Yongun;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.785-794
    • /
    • 2013
  • Combined sewer overflows during rainfall events contain sewer sediments and surface pollutants. This can cause significant chemical, physical and biological problems to receiving watershed. However, there are no method that can commonly apply to decide criteria for controlling the pollutant load. In this study, it sets up the reduction goals of combined sewer overflow through long-term simulation using the rainfall-runoff model. From a review of domestic and foreign management standard of combined sewer overflow for this, it makes decision that 60% (phase 1), 85% (phase 2) of total pollutant load and frequency per year for reduction goals is more proper. Also, the result of analyzing long-term simulation (minimum 10 years) applied to research basin indicates that reduction goals of BOD pollutant load are 1,123 kg (phase 1) and 2,374 kg (phase 2), and overflow volumes for research objective achievement are $11,685m^3$ (phase 1) and $24,701m^3$ (phase 2).

Flow Analysis of Urban Combined Sewer by Personal Computer (개인 전산기를 이용한 도시합류관거의 흐름해석)

  • Jun, Byung Ho;Lee, Hyung Gee;Koo, Ja Kong;Shin, Hang Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.127-140
    • /
    • 1988
  • The management of sewage and rainfall runoff becomes an emerging problem with the growth of urban communities. From the uncontrollable excess intensity or amount of rainfall, the conditions of sewer surcharge or manhole overflow could be generated in the combined sewer network where municipal or industrial wastewaters and rainfall runoff flow. The predictive model far the prevention of property and human life losses from this inundation was studied in this research. In the development of a mathematical flow model for the combined sewer surcharge and overflow, the Preissmann Slot concept and the four-point implicit method of finite difference were utilized. For the usage in personal computer, the overlapping segment method that required less memory storage was adopted. Through the simulation of hypothetical sewer network, the conservation of discharge volume was checked, and the usefulness of the Preissmann Slot was assured from the temporal distribution of discharge and depth along the sewer network. Also the possible field application for the correction of sewer diameters and slopes in the design of sewer network which has no surcharge/overflow condition was suggested.

  • PDF

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

Method to Determinate Monitoring Points in Sewer Networks (하수관망 내 모니터링 지점 선정 기법)

  • Lee, Jung-Ho;Jun, Hwan-Don;Park, Moo-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • In order to manage a sewer system effectively, flow conditions such as flux, water quality, Infiltration and Inflow (I/I), Combined Sewer Overflows (CSOs), etc need to be monitored on a regular base. Therefore, in sewer networks, a monitoring is so important to prevent the river disaster. Monitoring all nodes of an entire sewer system is not necessary and cost-prohibitive. Water quality monitoring points that can represent a sewer system should be selected in a economical manner. There is no a standard for the selection of monitoring points and the quantitative analysis of the observed data has not been applied in sewer system. In this study, the entropy method was applied for a sewer network to evaluate and determine the optimal water quality monitoring points using genetic algorithm. The entropy method allows to analyze the observed data for the pattern and magnitude of temporal water quality change. Since water quality measurement usually accompanies with flow measurement, a set of installation locations of flowmeters was chosen as decision variables in this study.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

Characteristics of Pollution Loads from the Combined Sewer during Dry Season (무강우시 합류식 하수관거의 오염부하 특성)

  • Won, Chul-Hee;Choi, Yong-Hun;Park, Woon-Ji;Shin, Min-Hwan;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.137-144
    • /
    • 2011
  • We have examined the pollutant load of combined sewer in dry days. Two monitoring sites (C-1, C-2) were equipped with an flowmeter. Monitoring was conducted from September 2004 to April 2006 for 20 months during dry days. Flowrate and concentration of pollutants are lowest from 3 to 6 o'clock, and it is high at 9, 12 and 21 o'clock. Most of organic matters exist in the dissolved state. The results show that pollution loads in C-2 area were 4.5-7.2 times higher than in C-1. Pollutant loads were high on Saturdays. Pollutant loads (kg/ha/day) of C-2 were 1.1-3.1 times higher those of C-1. However there was no significant difference in winter. Analysis of correlation coefficient of water quality parameter indicates that besides of flowrate all items in C-1 site have tight relationship respectively (p<0.01). In C-2 site, correlation coefficient of TP-SS, TP-TN, TP-flowrate, BOD-flowrate, BOD-SS and TN-TP are statistically significant (p<0.01).

Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin (영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구)

  • Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.