• 제목/요약/키워드: Combined sewer

검색결과 147건 처리시간 0.023초

분류식 하수관거로의 전환시 유입하수의 성상 변화 및 선회와류식 SBR공법의 처리 특성 (Change in Influent Concentration of Domestic Wastewater from Separated Sewer and Biological Nitrogen and Phosphorus Removal of a Full Scale Air-vent SBR)

  • 이장희;강호
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.63-70
    • /
    • 2012
  • This study was carried out to investigate change in influent concentration of domestic wastewater flowed from a newly constructed separate sewer system (SSS) and biological nutrients removal efficiency of a full scale Air-vent sequential batch reactor (SBR, $600m^3/d$). The average concentration of $BOD_5$, SS, T-N and T-P from SSS were 246.5 mg/L, 231.6 mg/L, 42.974 mg/L, 5.360 mg/L, respectively which corresponds to 2.2times, 1.2times, 1.8times and 2.1times higher than those from the conventional combined sewer system (CSS). The removal efficiency of $BOD_5$, SS, T-N, and T-P for the Air-vent SBR operated with influent from SSS averaged 99.1%, 99.0%, 91.2%, and 93.5%, respectively. Especially the respective nitrogen and phosphorus removal was 15% greater than that of the SBR operated with influent from CSS. Simultaneous nitrification and denitrification (SND) was observed in an aerobic reactor(II) as a result of DO concentration gradient developed along the depth by the Air-vent system. In order to achieve T-N removal greater than 90%, the C/N ratio should be over 6.0 and the difference between $BOD_5$ loading and nitrogen loading rate be over 100 kg/day (0.130 kg $T-N/m^3{\cdot}d$). Even with high influent T-P concentration of 5.360 mg/L from SSS (compared with 2.465 mg/L from CSS) T-P removal achieved 93.5% which was 15.5% higher than that of the SBR with influent from CSS. This is probably due to high influent $BOD_5$ concentration from SSS that could provide soluble carbon source to release phosphorus at anaerobic condition. In order to achieve T-P removal greater than 90%, the difference between $BOD_5$ loading and phosphorus loading rate should be over 100 kg /day (0.130 kg $T-N/m^3{\cdot}d$).

연속 강우-유출 모의기법을 이용한 최적 CSOs 산정에 관한 연구 (A Study of Optimal-CSOs by Continuous Rainfall/Runoff Simulation Techniques)

  • 조덕준;김명수;이정호;김중훈
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1068-1074
    • /
    • 2006
  • For receiving water quality protection a control systems of urban drainage for CSOs reduction is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as storm-water detention storage is highly dependant on the temporal variability of storage capacity available as well as the infiltration capacity of soil and recovery of depression storage. For the continuous long-term analysis of urban drainage system this study used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model has evolved that offers much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. Runoff characteristics manifested the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual CSOs, number of CSOs and event mean CSOs for the decision of storage volume.

합류식 하수관거 월류수의 인제거를 위한 응집제 투여 (Addition of Coagulants for Phosphorus Removal from Combined Sewer Overflows (CSOs))

  • 손상미;주티담롱판;박기영
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.295-302
    • /
    • 2012
  • The coagulation of combined sewer overflows ($CSO_{s}$) was investigated by jar-testing with several commercial coagulants. $CSO_{s}$ sample showed different characteristics of coagulation from secondary wastewater with three common coagulants, aluminum sulfate, ferric chloride and polyaluminum chloride (PACl). Jar-tests showed that relatively wide range of optimal SS and T-P removal yielded with alum and ferric chloride compared with cationic polymers, though efficient SS and T-P removal can be achieved with all three coagulants. The decrease of pH was caused by the increase in dosage of aluminum sulfate, ferric chloride and PACl as coagulants. The pH was changed from 7.0 to 4.7 with the dosages of ferric chloride 25 mL/L. Aluminum sulfate revealed pH of 5.0 and PACl was highest pH of 5.4 after dosing of coagulants. The optimal pH to treat $CSO_{s}$ with aluminum sulfate were 6-6.5; with PACl 6-7, and with ferric chloride higher than 7.

수질오염총량관리 배출부하량에 대한 강우영향 분석연구 (Rainfall Effects on Discharged Pollution Load in Unit Watershed Area for the Management of TMDLs)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.648-653
    • /
    • 2010
  • Discharged pollution load for the management of Total Maximum Daily Loads (TMDLs) is calculated on the basis of rainfall data for reference year. Rainfall has an influence on discharged pollution load in unit watershed with combined sewer system. This study reviewed the status of discharged pollution load and rainfall conditions. We also investigated rainfall effects on discharged pollution load by analyzing change of the load in accordance with increase of rainfall. The change ratio of discharged pollution load was 18.6% while inflow load only 5.8% for 5 years from 2004 to 2008 in Daejeon district. The greatest rainfall and rain days were over 2 times than the least during the period. This change in rainfall could have great effect on discharged pollution load. The analysis showed that discharged pollution load increased 2.1 times in case rainfall increased 2 times and 1.2 times in case rain days increased 2 times. Rainfall effects, therefore, should be considered to make resonable evaluation of discharged pollution load in the assessment of annual performances.

하수의 화학적 응집조건 및 응집제별 응집효율 분석 (Chemical Coagulation Conditions and Efficiency of Sewage with Al(III) and Fe(III) Coagulants)

  • 박준규;전동걸;박노백;전항배
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.463-474
    • /
    • 2010
  • In this study, chemical coagulation conditions for treating combined sewer overflow(CSO) occurred during rainy season were evaluated by jar tests with aluminum sulfate[$Al_2(SO_4)_3{\cdot}17H_2O$] and ferric chloride[$FeCl_3{\cdot}6H_2O$]. The raw domestic sewage sampled from the primary sedimentation tank at a local sewage treatment plant was filtered through $150{\mu}m$ sieve before using. Point of zero charge(PZC) for various dose of aluminum sulfate occurred at pH 5.8-6.5, while for ferric chloride occurred at pH 5.3-6.0 in term of streaming current(SC) values. Charge neutralization ability of aluminum sulfate was bigger than that of ferric chloride. Optimum pH and dose of aluminum sulfate and ferric chloride were 6.2, 0.438mM and 5.8, 0.925mM, respectively. Removal efficiencies of TCOD, turbidity, SS and TP were 75, 97, 95, 96% with aluminum sulfate and 74, 96, 98, 99% with ferric chloride at their optimum coagulation conditions. More efficient removal of SS, TP and small particles was possible with ferric chloride at optimum coagulation conditions. Both SC values and COD removal started to increase where soluble phosphorus was completely removed.

비점오염원 관리를 위한 독립호우 결정 (Estimation of Interevent Time for Management of Non-Point Source Pollutants)

  • 이의훈;유도근;김중훈
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3159-3168
    • /
    • 2014
  • 비점오염원 관리를 위한 독립호우의 결정은 월류수 처리시설의 설계에서 필수적이다. 비점오염원의 관리를 위해서는 총량을 결정해야만 하는데 이를 위해서는 결정된 독립호우에 의해 1회 평균강우량, 평균강우강도, 평균지속시간 등의 강우특성의 분석이 실시되어야만 한다. 독립호우의 결정은 무강우 지속시간의 산정(Interevent Time Definition, IETD)에 따라 분리할 수 있으며 이를 결정하기 위한 기존의 분석방법에는 자기상관 분석, 변동계수 분석, 연강우 평균발생횟수 분석 등이 있다. 본 연구에서는 기존의 IETD 분석방법에 따라 무강우시간을 산정한 후 방법별 문제점을 고찰하고 새로운 IETD 결정방법으로 지수함수 검정방법을 제안하였다. 또한, 검정방법을 통하여 결과값의 적절성을 검토하였다.

도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가 (A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model)

  • 탁용훈;김재동;김영도;강부식
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.395-406
    • /
    • 2016
  • 도시화로 인한 인구집중 및 개발 집중현상으로 하천변 저지대 및 지하공간 사용이 증가하였고, 불투수층이 증가하여 도시유역의 배수체계는 우수관거에 의존하고 있다. 이러한 변화로 인한 우수관거의 저류용량 부족 및 외수위의 영향으로 인한 도심지 역류 현상으로 인한 침수피해가 발생하고 있다. 하지만 기존의 홍수범람에 관한 연구는 대부분 외수범람과 내수침수를 유기적으로 연결하지 못하고 있다. 본 연구에서는 상습침수가 발생하는 도시유역에 대하여 도시유역 유출특성을 고려한 홍수의 정확한 예측을 위해 강우분석 및 외수위를 고려하고, 도시유출모형인 SWMM 모형을 이용하여 하수관거의 월류를 분석하였고, 이 결과를 홍수범람해석 모형과 연계하여 도시유역에서의 집중호우 발생시 침수해석을 실시하여 수방시설물의 홍수배제 효율을 분석하였다. SWMM 모형의 적용결과 외수위영향에 따른 원활한 내수배제가 불가능 한 것으로 나타났고, 관거 월류량이 많아진 것으로 나타났다. 월류된 우수가 지면을 따라 흐를 경우 저지대의 침수가 예상되고, 월류량이 많은 맨홀을 주요맨홀로 선정하였고, 월류수 저감을 위한 방안으로 주요 맨홀의 인근 지역에 저류지를 설치하는 방안과 각 맨홀들을 연결하는 관거를 확대하는 방안을 설정하였다. 월류 저감 시나리오 적용 결과 저류지 설치시 월류량의 45%, 관거 확대시 33~64%의 저감효과를 보였다. SWMM 모형의 결과를 이용하여 홍수범람해석 모형을 모의한 결과 지표경사와 도로를 따라 맨홀 월류수가 모여 침수현상을 발생시키는 것으로 나타났으며, 관거 확대 적용시 침수면적이 19.6%, 60.5% 줄어든 것으로 나타났다.

홍수범람모의를 위한 내외수 연계모형 개발 (Development of a Combined Model for Flood Inundation Simulation)

  • 유재홍;김형준;조용식
    • 한국방재학회 논문집
    • /
    • 제5권4호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 연구에서는 홍수범람을 모의하기 위하여 하천모형과 우수관망모형을 결합하였다. 하천의 범람을 모의하는 하천모형은 2차원 Saint Venant 방정식을 유한차분기법으로 차분화하여 수치모형을 구성하였다. ILLUDAS를 기반으로 하는 우수관망모형은 관망의 통수능과 홍수량을 비교하여 제내지에서의 침수현상을 해석한다. 내외수연계모형을 실제 홍수범람사상에 적용하여 제내지와 제외지에서 일어나는 홍수범람현상을 적절히 모의함을 확인할 수 있었다.

합류맨홀에서의 유사퇴적 저감을 위한 실험적 연구 (An Experimental Study for Reduction of Sedimentation Deposit in Combining Junction Manholes)

  • 김정수;김경범;윤세의
    • 한국수자원학회논문집
    • /
    • 제45권8호
    • /
    • pp.767-782
    • /
    • 2012
  • 일반적으로 관거 및 맨홀 등의 도시 배수 시스템에서의 유사 및 유송잡물의 퇴적은 유수 흐름의 저항, 합류식 하수도의 조기 운영 및 도시 침수 및 주수로에서의 필연적인 오염 발생 등의 하수도 시설에 심각한 영향을 미친다. 그러므로 배수관과 연결된 합류맨홀에서 유사의 거동 특성 및 퇴적 양상을 분석할 필요가 있다. 본 연구에서는 문헌조사 및 현장조사를 실시하여 실험장치를 제작하고 실험조건을 선정하였다. 선정된 실험조건인 맨홀 형상 조건(사각형, 원형), 유사 유입 조건, 유입 유사량 및 유사 유입 관거를 변화시키면서 실시하였다. 맨홀 내부에 경사형 benching을 설치한 개선형 합류맨홀은 맨홀의 형상에 관계없이 합류맨홀 내 유사퇴적을 저감시키는 데에 상당한 효과를 나타내고 있으므로 도시 배수 시스템에서 개선형 합류맨홀은 관거 시설의 배수능력을 증대시킬 것으로 판단된다.