• Title/Summary/Keyword: Combined Heat Transfer

Search Result 190, Processing Time 0.025 seconds

Evaluation Methods on ONDOL Thermal Environmental Index (온돌 온열환경지표 평가방법)

  • Kim, Sung-Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.

A proposal on SOFC-PEMFC combined system for maritime applications

  • Duong Phan Anh;Ryu Borim;Nguyen Quoc Huy;Lee Jinuk;Kang Hokeun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.162-163
    • /
    • 2022
  • Maritime transportation is going to transfer to alternative fuels as a result of the worldwide demands toward decarbonization and tougher maritime emissions regulations. Methanol is considered as a potential marine fuel, which has the ability to reduce SOx and CO2 emissions, reduce climate change effects, and achieve the objective of green shipping. This work proposes and combines the innovative combination system of direct methanol solid oxide fuel cells (SOFC), proton exchange membrane fuel cells (PEMFC), gas turbines (GT), and organic Rankine cycles (ORC) for maritime vessels. The system's primary power source is the SOFC, while the GT and PEMFC use the waste heat from the SOFC to generate useful power and improve the system's ability to use waste heat. Each component's thermodynamics model and the combined system's model are established and examined. The multigeneration system's energy and exergy efficiency are 76.2% and 30.3%, respectively. When compared to a SOFC stand-alone system, the energy efficiency of the GT and PEMFC system is increased by 19.2%. The use of PEMFC linked SOFC has significant efficiency when a ship is being started or maneuvered and a quick response from the power and propulsion plant is required.

  • PDF

Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy (태양열 온수 및 난방 일체형 복합시스템의 성능예측)

  • Han, Yuri;Park, Youn Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

Combined Convective Heat Transfer from Vertical Parallel Plates (수직 평행평판에서의 혼합대류 열전달)

  • 양성환;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.299-306
    • /
    • 1989
  • The combined convective heat transfer from vertical parallel plates with constant temperature has been studied by numerical method. The governing equations for the system are solved by the finite difference method and successive over relaxation scheme for Re$_{L}$ = 50 - 500, Gr = 10$^{4}$, Pr = 0.7. Results for various plate spacings and plate lengths are as follows ; For various plate spacings, the mean Nusselt number increases and then decreases as the dimensionless plate spacing increases. The optimum plate spacing for maximum mean Nusselt number decreases with increasing Reynolds number and can be expressed as a function of Reynolds number. For various plate lengths, the mean plate Nudest number increases as the dimensionless plate length decreases and Reynolds number increases.

Study on the Prediction of Absorption Performance by the Optimization of a Vertical Absorber (수직형 흡수기 최적화에 따른 흡수 성능 예측에 관한 연구)

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.194-202
    • /
    • 2005
  • The present study was analytically and experimentally carried out to predict the absorption characteristics on combined heat and mass transfer process in a vertical falling film of variable absorbers. Heat and mass transfer enhancements were analytically investigated. Effects of geometric parameters by insert device (spring) and corrugate, flow pattern on absorption performances has been also investigated. Especially, the optimal values of absorber geometry (ID=22.8mm, L=1150m) and kinetic variables (solution flow rate, flow pattern) for maximum absorption performance has been predicted by the numerical analysis. The maximum absorption performance in a numerical analysis and experiment was shown at the wavy-flow by insert device (spring).

Measuring Apparatus for Convective Heat Transfer Coefficient of Nanofluids Using a Thermistor Temperature Sensor (더미스터 온도센서를 이용한 나노유체의 대류열전달계수 측정 장치)

  • Lee, Shin Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.103-110
    • /
    • 2016
  • Fine wires made from platinum have been used as sensors to evaluate the convection performance of nanofluids. However, the wire sensor is difficult to handle due to its fragility. Additionally, an unrealistic convective heat transfer coefficient (h) is obtained if a rigorous calibration process combined with precision equipment is not used for measurement. This paper proposes a new evaluation apparatus for h of nanofluids that uses a thermistor sensor instead of the platinum wire. The working principles are also explained in detail. Validation experiments for pure engine oil comparing h from the two sensors confirmed numerous practical benefits of the thermistor. The proposed system can be used as a useful tool to justify the adoption of developed nanofluids.

A study on the estimation of temperature distribution around gas storage cavern

  • Lee Yang;Moon Hyun-Koo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.238-243
    • /
    • 2003
  • As there are many advantages on underground caverns, such as safety and operation, they can also be used for gas storage purpose. When liquefied gas is stored underground, the cryogenic temperature of the gas will affect the stability of the storage cavern. In order to store the liquefied gas successfully, it is essential to estimate the exact temperature distribution of the rock mass around the cavern. In this study, an analytic solution and a conceptual model that can estimate three-dimensional temperature distribution around the storage cavern are suggested. When calculating the heat transfer within a solid, it is likely to consider the solid as the intersection of two or more infinite or semi-infinite geometries. Therefore heat transfer solution for the solid is expressed by the product of the dimensionless temperatures of the geometries, which are used to form the combined solid. Based on the multi-dimensional transient heat transfer theory, the analytic solution is successfully derived by assuming the cavern shape to be of simplified geometry. Also, a conceptual model is developed by using the analytic solution of this study. By performing numerical experiments of this multi-dimensional model, the temperature distribution of the analytic solution is compared with that of numerical analysis and theoretical solutions.

  • PDF

Heat Transfer Behavior of Viscoelastic Fluid including buoyancy effect with Modified Temperature Dependent Viscosity Model in a Rectangular Duct (수정점도 모델을 이용한 직사각형 덕트에서의 부력을 고려한 점탄성 유체의 열전달 특성)

  • Sohn C. H.;Jang J. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.192-198
    • /
    • 1999
  • The present study proposes modified temperature-dependent non-Newtonian viscosity model and investigates flow characters and heat transfer enhancement of the viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. The proposed modified temperature dependent viscosity model has non-zero value near the high temperature and high shear rate region while on the existing viscosity models have zero value. Two versions of thermal boundary conditions involving difference combination of heated walls and adiabatic walls are analyzed in this study. The combined effect of temperature dependent viscosity, buoyancy, and secondary flow caused by second normal stress difference are ail considered. The Reiner-Rivlin model is adopted as a viscoelastic fluid model to simulate the secondary flow caused by second normal stress difference. Calculated Nusselt numbers by the modified temperature-dependent viscosity model gives under prediction than the existing temperature-dependent viscosity model in the regions of thermally developed with same secondary normal stress difference coefficients with experimental results in the regions of thermally developed. The heat transfer enhancement of the viscoelastic fluid in a 2:1 rectangular duct is highly dependent on the secondary flow caused by the magnitude of second normal stress difference.

  • PDF

Effects of the Convector Plate Shape and the Atmospheric Gas on Characteristics of Heat Transfer in a Batch Annealing Furnace (BAF에서 분위기 가스와 대류판 형태가 열전달 특성에 미치는 영향)

  • Yoon, Soon Hyun;Kim, Moon Kyung;Kim, Dae Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.72-79
    • /
    • 1996
  • In a BAF(Batch Annealing Furnace), various studies have been pursued in order to reduce energy consumption rate to improve productivity and to stabilize the properties of products. The purpose of this study was to investigate the effects of both the atmospheric gas and convector plate shapes on the augmentation of heat transfer. The use of hydrogen instead of nitrogen as an atmospheric gas, combined with high convection in the BAF, has shown that considerable increases in furnace out put and significantly improved material quality are attainable. Because convector plate shapes make the atmosheric gas easily flow density, high diffusivity and reducing character of hydrogen, a better heat transfer rates resulting in uniform material temperature distribution and improved coil surface quality can be achieved. Also, it was found that the closed convector plate took more time for the annealing cycle time than the other plate type(open-type)by about ten hours.

  • PDF