• Title/Summary/Keyword: Combined Cycle Plant

Search Result 225, Processing Time 0.022 seconds

A Study on Comparative Analysis of Socio-economic Impact Assessment Methods on Climate Change and Necessity of Application for Water Management (기후변화 대응을 위한 발전소 온배수 활용 양식업 경제성 분석)

  • Lee, Sangsin;Kim, Shang Moon;Um, Gi Jeung
    • Journal of Korean Society of societal Security
    • /
    • v.4 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • In order to resolve the problem of change in global climate which is worsening as days go by and to preemptively cope with strengthened restriction on carbon emission, the government enacted 'Framework Act on Low Carbon Green Growth' in 2010 and selected green technology and green industry as new national growth engines. For this reason, the necessity to use the un-utilized waste heat across the whole industrial system has become an issue, and studies on and applications of recycling in the agricultural and fishery fields such as cultivation of tropical crops and flatfishes by utilizing the waste heat and thermal effluent generated by large industrial complexes including power plants are being actively carried out. In this study, we looked into the domestic and overseas examples of having utilized waste heat abandoned in the form of power plant thermal effluent, and carried out economic efficiency evaluation of sturgeon aquaculture utilizing thermal effluent of Yeongwol LNG Combined Cycle Power Plant in Gangwon-do. In this analysis, we analyzed the economic efficiency of a model business plan divided into three steps, starting from a small scale in order to minimize the investment risk and financial burden, which is then gradually expanded. The business operation period was assumed to be 10 years (2012~2021), and the NVP (Net Present Value) and economic efficiency (B/C) for the operation period (10 years) were estimated for different loan size by dividing the size of external loan by stage into 80% and 40% based on the basic statistics secured through a site survey. Through the result of analysis, we can see that reducing the size of the external loan is an important factor in securing greater economic efficiency as, while the B/C is 1.79 in the case the external loan is 80% of the total investment, it is presumed to be improved to 1.81 when the loan is 40%. As the findings of this study showed that the economic efficiency of sturgeon aquaculture utilizing thermal effluent of power plant can be secured, it is presumed that regional development project items with high added value can be derived though this, and, in addition, this study will greatly contribute to reinforcement of the capability of local governments to cope with climate change.

  • PDF

Comparative studies in Perception of Patient safety culture of Nurses and Dental hygienist (간호사와 치위생사의 환자안전문화 인식수준 비교연구)

  • Kim, Mi-Young;Kim, Young-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5196-5205
    • /
    • 2012
  • Purpose: The Purpose of this study were to compare the level of perception and to identify factors associated with perception on patient safety culture by nurses and hygienists. Method: The data were collected from september to December, 2010 using Hospital survey on patient safety culture questionnaires. The subjects were 399 Nurses, hygienists, recruited from the hospital in Busan & Kyungnam. The collected data were analyzed using SPSS descriptive statistics, mean and standard deviation, t-test and ANOVA, Spearman rank coefficient. Result: The perception level of nurses on patient safety culture was 3.48. In case of hygienists, the level was 3.51. Compared to nurses, hygienists showed a significantly difference on the items "Staff arrangement"(t=2.841, p<.01) and "Administator attitude"(t=-2.471, p<.05), "Feedback and communication in accident"(t=-3.356, p<.01). Nurses and hygienists' age and career, working hour per week were identified as factor associated with patient safety culture. Conclusion: The perception level of hospital health providers on patient safety culture was moderate. and identified factors associated with patient safety culture were age and career, working hour per week.

Test of Insecticidal Efficacy of Some Commercial Natural Products against Trialeurodes vaporariorum(Homoptera : Aleyrodidae), Bemisia tabaci(Homoptera : Aleyrodidae), and Spodoptera litura(Lepidoptera : Noctuidae)

  • Jeong, Hyung-Uk;Kim, Man-Il;Chang, Sung-Kwon;Oh, Hyung-Keun;Kim, Ik-Soo
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2009
  • The greenhouse whitefly, Trialeurodes vaporariorum (Westwood) and the sweet potato whitefly, Bemisia tabaci (Gennadius) are serious insect pests that have a wide host range including cucumber, tomato, and pepper. In this study, we tested larvicidal efficacy of several on-the-market environment-friendly agricultural materials (EFAM) to select the effective products after the target pests were stabilized in indoor rearing condition. The developmental periods of two whiteflies are as follows: in the case of T. vaporariorum, egg duration is 9.6 days and nymph is 18.9 days, and in the case of B. tabaci, egg duration is 7.4 days and nymph is 15.2 days under $25^{\circ}C$ with relative humidity (RH) of $60{\pm}5%$ and a photoperiod of 16 L:8D. The total period of T. vaporariorum was 5 days longer than B. tabaci. Among 22 EFAMs six products showed more than 60% of insecticide efficacy against T. vaporariorum BTV B, BTV D, BTV G, BTV L, BTV M, and BTV S. On the other hand, seven EFAM products showed over 60% of insecticide efficacy against B. tabaci BTV D, BTV G, BTV K, BTV L, BTV M, BTV N, and BTV U. In the case of Spodptera litura previously, 16 EFAMs were tested against $2^{nd}$ instar S. litura, and six EFAMs were found to have more than 90% efficacy. Test of these six EFAMs against entire larval stages were performed in this study. Although some of these products showed still more than 90% of insecticidal efficacy against up to $3^{rd}$ instar larvae, the efficacy of these EFAMs sharply decreased as ages increase, resulting in less than 60% of efficacy of the products at most. This result indicates the difficulty to control S. litura with the on-the-market EFAMs alone under economic injury level. Collectively, it is required to find more EFAMs, and find alternative method, and combined way of controlling to control those insect pests tested in this study.

Combustion Performance Test of Syngas Gas in a Model Gas Turbine Combustor - Part 2 : NOx/CO emission Characteristics, Temperature Characteristics and Flame Structures (모델 가스터빈 연소기에서 합성가스 연소성능시험 - Part 2 : NOx/CO 배출특성, 온도특성, 화염구조)

  • Lee, Min Chul;Yoon, Jisu;Joo, Seong Pil;Yoon, Youngbin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.8
    • /
    • pp.639-648
    • /
    • 2013
  • This paper describes on the NOx/CO emission characteristics, temperature characteristics and flame structures when firing coal derived synthetic gas especially for gases of Buggenum and Taean IGCC. These combustion characteristics were observed by conducting ambient-pressure elevated-temperature combustion tests in GE7EA model combustor when varying heat input and nitrogen dilution ratio. Nitrogen addition caused decrement in adiabatic flame temperature, thus resulting in the NOx reduction. At low heat input condition, nitrogen dilution raised the CO emission dramatically due to incomplete combustion. These NOx reduction and CO arising phenomena were observed at certain flame temperature of $1500^{\circ}C$ and $1250^{\circ}C$, respectively. As increasing nitrogen dilution, adiabatic flame temperature and combustor liner temperature were decreased and singular points were detected due to change in flame structure such as flame lifting. From the results, the effect of nitrogen dilution on the NOx/CO and flame structure was examined, and the test data will be utilized as a reference to achieve optimal operating condition of the Taean IGCC demonstration plant.

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.