• Title/Summary/Keyword: Combination Implant Crown

Search Result 8, Processing Time 0.029 seconds

SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT (콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례)

  • Kim, Rae-Gyoung;Song, Eon-Hee;Choi, Byeong-Gap;Kim, Hyoun-Chull;Ahn, Hyun-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

Implant assisted removable partial denture with implant surveyed prostheses: A 9-year follow-up (임플란트 서베이드 보철물을 이용한 임플란트 보조 국소의치의 9년 경과 관찰 증례)

  • Lee, Jae-Rim;Yoon, Hyung-In;Kim, Hee-Sun;Sim, Hye-Young;Han, Yoon-Sic
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.211-221
    • /
    • 2022
  • Implant placement may be restricted by anatomical and/or financial limitations in restoring a completely edentulous arch, or the patients' unwillingness to have extensive surgical procedures. Implant assisted removable partial dentures (IARPD) in combination with anterior fixed implant prostheses can be proposed as an alternative treatment option for the restoration of a completely edentulous arch. In this case, a 56-year-old female patient who has a fully edentulous maxilla opposed by partially edentulous mandible was treated. The treatment option for the maxilla consisted of an implant-assisted removable partial denture supported by four anterior fixed implant prostheses. The mandible was restored with 8 anterior fixed partial dentures and posterior fixed implant-supported prostheses. Long-term follow-up and supportive periodontal treatment were performed for 9 years, and the patient was satisfied with the overall appearance as well as masticatory function.

An innovative prostheses design for rehabilitation of severely mutilated dentition: a case report

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Partial edentulism has multiple implications in relation to function, esthetics and future rehabilitative treatment. This case report illustrates the management of a patient with extreme consequences of partial edentulism. The main clinical findings were unopposed remaining teeth, overeruption of the remaining teeth, loss of vertical dimension of occlusion, and significant disfigurement of the occlusal plane. Following the diagnostic procedure, a well-coordinated prosthodontic treatment involving liaison with other dental disciplines was indicated. The management involved an innovative combination of fixed and removable prostheses in conjunction with crown lengthening surgery and strategic implant placement. Series of provisional prostheses were applied to facilitate the transition to the final treatment.

Finite Element Analysis of Supporting Bone according to Custom Abutment Angles (맞춤형 지대주 각도에 따른 지지골의 유한요소 분석)

  • Nam, Min-Gyeong;Kim, Nam-Sic
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.115-120
    • /
    • 2015
  • Purpose: The purpose of this study is a finite element analysis of supporting bone according to custom abutment angle. Methods: Implant fixture was selected with a diameter of 4 mm and the length of 13 mm. The fixture and abutment was designed by a combination of the abutment screw clamping force to produce a custom abutment model of $0^{\circ}$, $15^{\circ}$, $25^{\circ}$ and $35^{\circ}$. The loading condition of 176 N was applied to the lingual surface of the crown, near to the incisor edge, and horizontal load. An oblique load of $90^{\circ}$ was applied long axis of the implant fixture analyze the stress of supporting bone. Results: The result of mechanical analysis was observed that the supporting bone stress analysis of the horizontal load, the von Mises stress values (MPa) are given in the order of TH00 (432.6) > TH25 (418.0) > TH15 (417.4) > TH35 (415.8), the oblique load, the von Mises stress values are given in the order of TO00 (459.3) > TO15 (399.6) > TO25 (374.8) > TO35 (343.4) Conclusion: The $35^{\circ}$ abutment over the current clinical tolerance limits will be available for clinical application.

Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation (임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석)

  • Seo, Young-Hun;Lim, Hyun-Pil;Yun, Kwi-Dug;Yoon, Suk-Ja;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to find an inclination slope of the screw thread that is favorable in distributing the stresses to alveolar bone by using three dimensional finite element analysis. Materials and methods: Three types modelling changed implant thread with fixed pitch of 0.8 mm is the single thread implant with $3.8^{\circ}$ inclination, double thread implant with $7.7^{\circ}$ inclination and the triple thread implant with $11.5^{\circ}$ inclination. And three types implant angulation is the $0^{\circ}$, $10^{\circ}$ and $15^{\circ}$ on alveolar bone. The 9 modelling fabricated for three dimensional finite element analysis that restored prosthesis crown. The crown center applied on 200 N vertical load and $15^{\circ}$ tilting load. Results: 1. The more tilting of implant angulation, the more Von-Mises stress and Max principal stress is increasing. 2. Von-Mises stress and Max principal stress is increasing when applied $15^{\circ}$ tilting load than vertical load on the bone. 3. When the number of thread increased, the amount of Von-Mises stress, Max principal stress was reduced since the generated stress was effectively distributed. 4. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants. When comparing the magnitude of the maximum principal stress, the triple thread implant had a least amount of stress. This shows that the triple thread implant gave a best result. Conclusion: A triple thread implant to increase in the thread slope inclination and number of thread is more effective on the distribution of stress than the single and double thread implants especially, implant angulation is more tilting than $10^{\circ}$ on alveolar bone. Thus, effective combination of thread number and thread slope inclination can help prolonging the longevity of implant.

Effect of abutment types and resin cements on the esthetics of implant-supported restorations

  • Asena Ceken;Hamiyet Kilinc;Sedanur Turgut
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.114-125
    • /
    • 2023
  • PURPOSE. The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades. MATERIALS AND METHODS. A1/LT MZ specimens were prepared (10 × 12 × 1 mm, N = 30) and divided into 3 groups according to cement shades as transparent (Tr), yellow (Y) and opaque (O). Abutment specimens were obtained from 4 different materials including zirconia (Group Z), hybrid (Group H), titanium (Group T) and anodized yellow titanium (Group AT). MZ and abutment specimens were then cemented. L*, a*, and b* parameters were obtained from MZ, MZ + abutment, and MZ + abutment + cement. ∆E001* (between MZ and MZ + abutment), ∆E002* (between MZ and MZ + abutment + cement) and ∆E003* (between MZ + abutment and MZ + abutment + cement) values were calculated. Statistical analyses included 2-way ANOVA, Bonferroni, and Paired Sample t-Tests (P < .05). RESULTS. Abutment types and resin cements had significant effect on L*, a*, b*, ∆E001*, ∆E002*, and ∆E003* values (P < .001). Without cementation, whereas zirconia abutment resulted in the least discoloration (∆E001* = 0.68), titanium abutment caused the most discoloration (∆E001* = 4.99). The least ∆E002* = 0.68 value was seen using zirconia abutment after cementation with yellow shaded cement. Opaque shaded cement caused the most color change (∆E003* = 5.24). Cement application increased the L* values in all groups. CONCLUSION. The least color change with/without cement was observed in crown configurations created with zirconia abutments. Zirconia and hybrid abutments produced significantly lower ∆E002* and ∆E003* values in combination with yellow shaded cement. The usage of opaque shaded cement in titanium/anodized titanium groups may enable the clinically unacceptable ∆E00* value to reach the acceptable level.

Clinical remarks about esthetics in the case of full zirconia restoration utilizing Zirkonzahn Prettau® block (지르코잔 프레타우 블럭을 이용한 Full Zirconia 수복 시 심미에 관한 임상적 소견)

  • Park, Jong-Chan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.30-46
    • /
    • 2013
  • Porcelain fused to metal crown has been used mostly over the last 50 years for restorations in dentistry. However, the patients' awareness of aesthetic aspect, biocompatibility and the problems such as an allergy to metals led to the growing interest in the 'metal free restoration'. In particular, the price of the precious metals that have been mainly used to date has risen drastically, which made them impossible to play their role as oral restorative materials anymore, and in addition, the PFM restoration has intrinsic problems of chipping and fracture. Therefore, the CAD/CAM has been drawing more attention than ever due to the popular needs for the material that is more aesthetic and stronger for restoration of the molar implant. Considerations in carrying out the full zirconia restoration are as follows: 1) strength, 2) combination work, 3) light penetrability, 4) treatment of cracks, 5) the color reproducibility of the block, 6) the abrasivity of antagonistic tooth, 7) low temperature degradation. In this presentation, the color reproducibility of the block will be discussed. One of the biggest reasons for avoiding the full zirconia restoration is that it is difficult to reproduce the natural color compared to the conventional PFM restoration. Thus, many clinicians show reluctance due to the exposure of the ugly block when the coloring on the surface is removed after occlusal adjustment. From the experience of using blocks by Zirkonzahn for more than 4 years, it is considered that these problems can be addressed to some degrees. Accordingly, how to make restorations that are well in harmony with surrounding prosthesis or natural teeth will be discussed.