• 제목/요약/키워드: Column Members

검색결과 501건 처리시간 0.026초

A study on compressive strength of concrete in flexural regions of reinforced concrete beams using finite element analysis

  • Cho, Chang-Geun;Hotta, Hisato
    • Structural Engineering and Mechanics
    • /
    • 제13권3호
    • /
    • pp.313-328
    • /
    • 2002
  • Based on the orthotropic hypoelasticity formulation, a triaxial constitutive model of concrete is proposed. To account for increasing ductility in high confinement of concrete, the ductility enhancement is considered using so called the strain enhancement factor. It is also developed a three-dimensional finite element model for reinforced concrete structural members based on the proposed constitutive law of concrete with the smeared crack approach. The concrete confinement effects due to the beam-column joint are investigated through numerical examples for simple beam and structural beam member. Concrete at compression fibers in the vicinity of beam-column joint behaves dominant not only by the uniaxial compressive state but also by the biaxial and triaxial compressive states. For the reason of the severe confinement of concrete in the beam-column joint, the flexural critical cross-section is observed at a small distance away from the beam-column joint. These observations should be utilized for the economic design when the concrete structural members are subjected to high confinement due to the influence of beam-column joint.

강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석 (Parameter Study of Buckling Behavior of Steel Built-up Column)

  • 김진용;김성보
    • 대한토목학회논문집
    • /
    • 제31권2A호
    • /
    • pp.79-87
    • /
    • 2011
  • 이 연구에서는 압축력을 받는 강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석을 수행하였다. 압축력을 받는 조립기둥에서 기둥 전체 길이에 설치되는 H-형강 단면의 주 부재와 H-형강의 상 하 플랜지를 연결하는 배튼의 휨 및 전단력에 의한 전단변형효과를 고려한 좌굴하중 식을 제시하였다. 조립기둥의 길이, H-형강 주부재의 간격, 배튼의 개수, 배튼 작용을 하는 상 하 덮개판의 설치 여부에 따른 좌굴하중의 변화를 분석하였다. 일반 볼트 및 고장력 볼트가 사용된 조립 기둥의 설계에 사용되는 AISC 설계식이 배튼 및 주 부재의 간격이 큰 조립 기둥에도 활용할 수 있는지에 대한 적용성을 검토하였다. 이 연구에서 제시한 엄밀해 그리고 보요소 및 판요소를 사용한 유한요소해석 그리고 AISC의 설계식에 의한 결과를 비교 분석하여 강재 조립기둥의 좌굴거동에 대한 매개변수 해석을 수행하였다.

평면프레임 구조의 개선된 좌굴설계 (Improved Stability Design of Plane Frame Members)

  • 김문영;송주영;경용수
    • 한국강구조학회 논문집
    • /
    • 제18권2호
    • /
    • pp.225-237
    • /
    • 2006
  • 김 등(2005a, b)의 연구를 확장시켜 시스템 좌굴 고유치해석법을 이용한 유효좌굴길이 산정법과 2차 탄성해석기법을 이용한 2차모멘트를 이용하여 축력과 휨모멘트를 받는 라멘구조의 보-기둥부재에 대한 개선된 좌굴설계법을 제안한다. 이를 위하여 먼저 국내도로교설계기준, AISC-LRFD, SRC의 각 설계기준에 제시된 내하력 기준식을 이용하여 응력-변형율 관계를 유도하고, 이를 이용한 탄성 및 비탄성 좌굴 고유치해석을 이용한 유효좌굴길이 산정법을 고찰한다. 또한 라멘구조에 대하여 AISC-LRFD에서 제시하고 있는 좌굴 안정성 검토식과 본 연구에서 제시하는 안정성 검토식을 해석예제를 통하여 비교, 검토를 행한다.

Constructability Analysis of Green Columns at the Low Bending Moment Zone

  • Lee, Sung-Ho;Park, Jun-Young;Lim, Chae-Yeon;Kim, Sun-Kuk
    • Journal of Construction Engineering and Project Management
    • /
    • 제3권4호
    • /
    • pp.12-19
    • /
    • 2013
  • Green Frame is an environmentally friendly column-beam system composed of composite PC members that can increase buildings' life spans while reducing resource consumption. Typically, connections of PC and RC columns occur at the boundaries of each floor, which is at the upper section of slabs, causing the boundary of each floor to generate the maximum moment. Although it is not optimal in terms of structural safety to connect members at a location where the moment is high, this approach is highly adopted due to its constructability. We propose that a superior approach that employs the concept of connecting columns at the low bending moment zone can be applied to quickly and safely install green columns, the main structural members of Green Frame. Connection of green columns at the low bending moment zone can be classified into three techniques, depending on the method of reinforcing the joints, which have different connection characteristics and construction methods. Research is needed to compare the features of each method of reinforcing the joints so that the most appropriate column connection method can be chosen for the site conditions. This study aims to confirm the structural safety of the connection component at the low bending moment zone and to compare and analyze the construction duration, unit price, quality and safety performance of each column connection method. The study results are anticipated to activate the use of composite precast concrete and to be used as development data in the future.

스트럿 부재와 융합단면을 이용한 기둥-보 강결 구조물 해석 (Analysis of Beam-column Joints in a Structure using Strut Members and Composite Section)

  • 조재형;송재호
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.289-299
    • /
    • 2020
  • The composition of convergence cross-section of the material is a technique that provides reasonable design and construction of structures. It is frequently used in medium-sized bridges and architectural structures. However, the structural behavioral spare capacity enhancement of the structure by the application of the convergence cross-section is still limited by the expandability due to the limiting state of each material. In order to overcome these limitations, this study reasonably analyzed the construction stages before and after the convergence cross-section constructed and developed a technique for forming multi-point boundary conditions using struts, which are compression members. Based on the existing cases, a reasonable construction step for forming the material composite section of the entire structural system of the structure was derived, and a numerical analysis model for a specific part was constructed to analyze the behavior of the strut application. As a result of this study, the effect of reducing the sectional force of 7.40% in beam-column joint and 6.31% in the center of girder was derived, and the deflection, which is a measure of the serviceability of the structure, improved by 54.41% from the installation and dismantling of strut members at each construction stage.

합성 PC부재의 Steel-joint Connection Method 개발 기초연구 (A basic study of steel-joint connection method of composite precast concrete members)

  • 김근호;이동훈;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2013
  • Green Frame is a column-beam system formed by composite precast concrete column and beam connected with steel buried in both members. During the installation of Green columns, the columns of Green Frame, covering 3 floors per each piece and beams, the eccentricity can be observed due to the construction error and the weight of beam itself. Such eccentricity may have a little influence on a single frame, yet, it can develop critical issues to the installation of subsequent beams or beams on the upper floors in the context of a building as a whole that has multiple frames. These issues lead to delay in frame installation, decrease of productivity and increase of cost, etc. Therefore, this study presents a steel-joint connection method in order to solve the issues. The steel-joint connection method exists on slope plane and reinforcing plate in steel frame buried in composite PC members. Through this method, the issues can be resolved without requiring additional equipment or manpower.

  • PDF

원형단면 멀티기둥 풍력타워 적용 T형 강관조인트 강도 평가 (Strength Evaluation of T-type Tubular Joints for Circular Section Multi-Column Wind Towers)

  • 김경식;박현용;서동혁
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.119-129
    • /
    • 2015
  • 강재량을 줄이면서도 풍하중의 영향을 완화시킬 수 있는 장점으로, 수평재로 서로 연결된 다수의 수직 원형강관으로 구성된 멀티기둥 풍력타워 시스템은 기존의 단일 실린더형 타워구조에 대한 대안으로 고려될 수 있다. 멀티기둥 타워를 하나의 타워구조로 거동하게 하기 위해서는 수직 강관과 수평 강관의 연결부인 강관조인트의 강도 확보가 중요하다. 본 연구에서는 멀티기둥에 적용될 수 있는 T 조인트의 강도평가를 수행하였다. AISC, Eurocode3, ISO 19902, CIDECT의 4가지 강관조인트 설계기준을 검토하고, 조인트에서 주강관과 지강관의 세장비에 대한 매개변수해석을 통하여 설계기준에서 제공되는 강도산정식의 타당성을 검토하였다.

Shake-table tests on moment-resisting frames by introducing engineered cementitious composite in plastic hinge length

  • Khan, Fasih A.;Khan, Sajjad W.;Shahzada, Khan;Ahmad, Naveed;Rizwan, Muhammad;Fahim, Muhammad;Rashid, Muhammad
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.23-34
    • /
    • 2022
  • This paper presents experimental studies on reinforced concrete moment resisting frames that have engineered cementitious composite (ECC) in plastic hinge length (PHL) of beam/column members and beam-column joints. A two-story frame structure reduced by a 1:3 scale was further tested through a shake-table (seismic simulator) using multiple levels of simulated earthquake motions. One model conformed to all the ACI-318 requirements for IMRF, whereas the second model used lower-strength concrete in the beam/column members outside PHL. The acceleration time history of the 1994 Northridge earthquake was selected and scaled to multiple levels for shake-table testing. This study reports the observed damage mechanism, lateral strength-displacement capacity curve, and the computed response parameters for each model. The tests verified that nonlinearity remained confined to beam/column ends, i.e., member joint interface. Calculated response modification factors were 11.6 and 9.6 for the code-conforming and concrete strength deficient models. Results show that the RC-ECC frame's performance in design-based and maximum considered earthquakes; without exceeding maximum permissible drift under design-base earthquake motions and not triggering any unstable mode of damage/failure under maximum considered earthquakes. This research also indicates that the introduction of ECC in PHL of the beam/column members' detailing may be relaxed for the IMRF structures.

그린프레임 현장생산용 거푸집 시스템 개발을 위한 구조설계 절차 (A Process for Structural Design of Form System for in-situ Production of Green Frame)

  • 임채연;김근호;나영주;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2012
  • The precast concrete column-beam structure, Green Frame, allows the main structural members such as precast concrete column and beam to be produced on the site, resulting in a reduction of transportation cost and the margin of plant. However, existing plywood from for in-situ production of precast concrete members has problems like putting in inordinate human resource, falling-off in quality and workability. To solve those problems, form system for in-situ production of precast concrete members shall be developed. In this regard, this study aims to analyze the structural concept of from system for in-situ production. The result of this study will use for development of form system for in-situ production.

  • PDF

Vibration behaviour of axially compressed cold-formed steel members

  • Silvestre, N.;Camotim, D.
    • Steel and Composite Structures
    • /
    • 제6권3호
    • /
    • pp.221-236
    • /
    • 2006
  • The objective of this work is to describe the main steps involved in the derivation of a GBT (Generalised Beam Theory) formulation to analyse the vibration behaviour of loaded cold-formed steel members and also to illustrate the application and capabilities of this formulation. In particular, the paper presents and discusses the results of a detailed investigation about the local and global free vibration behaviour of lipped channel simply supported columns. After reporting some relevant earlier GBT-based results dealing with the buckling and vibration behaviours of columns and load-free members, the paper addresses mostly issues concerning the variation of the column fundamental frequency and vibration mode nature/shape with its length and axial compression level. For validation purposes, some GBT-based results are also compared with values obtained by means of 4-node shell finite element analyses performed in the code ABAQUS.