• Title/Summary/Keyword: Color stimulation

Search Result 91, Processing Time 0.027 seconds

Efficacy of a self - applied paint - on whitening gel combined with wrap (Wrap을 사용하는 자가 도포 미백젤의 치아 미백 효과)

  • Kim, Soo-Yeon;Ahn, Jae-Hyun;Kim, Ji-Young;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.175-185
    • /
    • 2018
  • Purpose: The aim of this clinical study was to evaluate the efficacy and safety of a self - applied paint - on whitening gel combined with wrap to increase the effect of a whitening gel and minimize gingival irritation. Materials and Methods: Ninety adult volunteers were randomly treated to a control group and two experimental groups using whitening gel containing 2.8% and 3.0% hydrogen peroxide for 30 persons each. They had used the wrap and whitening gel on maxillary 4 anterior teeth for 30 minutes per day during 2 weeks. Whitening tooth color response was measured by VITA shade guide and ShadeEye $NCC^{(R)}$. And side effects were assessed from interview and intraoral examination. The efficacy and safety evaluations were statistically analyzed. Results: In the evaluation with VITA shade guide, there was significantly the whitening effect in experimental groups compared with the control group. In the evaluation with ShadeEye $NCC^{(R)}$, the 3.0% experimental group showed significantly the whitening effect compared to the control group and the 2.8% experimental group (P < 0.05). There were some complaints of minor side effects, but there did not find abnormal symptoms of the gingival stimulation in all groups. Conclusion: A self - applied paint - on whitening gel combined with wrap can be used as a useful self-whitening material because the whitening effect increases as the concentration of hydrogen peroxide from 2.8% to 3.0% and also no significant side effects are observed.

The Analysis of Research Trend about Management of Low Back Pain (요통관리에 관한 연구동향 분석)

  • Hyun, Kyung-Sun
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1998
  • The result of studying papers about management of lower back pain published in domestic and foreign nursing and medical magazines in these 10 years is as follows ; 1. General characteristic of lower back pain ; 1) In sex distribution, there were more men than women in 5 papers and more women than men in 4 papers among 9 papers surveryed. 2) In age distribution, thirties to forties of patients had more lower back pain as surveyed by general hospitals and fifties to sixties of patients had more lower back pain as surveyed by oriental medical hospitals. 3) In cause factor, there were 50 to 65% of sprain, 32 to 44% of herniated intervertebral disc and 13 to 29% of degenerative changes. 4) In symtom distribution, there were 26 to 57% of lower back pain, 42 to 65% of lower back pain with radiating pain and 34 to 99% of paravertevral muscle spasm. 5) In period of pain management distribution, 18 to 40% of patients experienced pain for less than 6 months and 59 to 82% of them experienced pain for more than 6 months in 3 papers among 4 papers. 6) In surveying the treatment, 66 to 88% of patients had conservative treatment and there were treatments of general hospital, oriental medicine, self remedy and traditional practice in conservative treatment. 7) In job distribution, 12 to 50% of them were housekeepers, 23 to 31% office workers, 4.6 to 36% blue color workers and 11 to 15% students. 2. As psychological character lower back pain paients had anxiety, depression, anger-hostility, phobic anxiety, neurasthenia, hypochondriasis, and interpersonal sensitivity. 3. To distinguish the cause of lower back pain, plain lumbar roentgenogram, straight leg rasing test, eletromyelogic findings, somatosensory evoked potentials CT and MRI were performed. 4. To relieve lower back pain. epidural adhesiolysis, epidulal injection of local anesthetic in mixture with steroid, lumbar spinal root block, low level laser therapy, acupuncture like transcutaneous nerve stimulation(AL TENS), topical capsaicin and lumbar orthotics were used in medical field, and relaxation technique was used in nursing field. 5. Mckenzie's extension exercise and William's flexsion exercise for lower back pain were used in medical field and Yoga exercise was applied in nursing field. 6. The more school education and self efficacy were high, the better they had active coping lower back pain positively and the less self efficacy was the more they had serious pain. As a result of studying the paper there have been very little research for lower back pain in nursing fields of Korea and foreign countries. Because 60 to 80% of population expeience lower back pain at least more than once, it is necessary to develop the study and clinical practice for management of lower back pain.

  • PDF

Effects of Handling and Transport Vehicle on Stress and Carcass Quality of Market Pigs (출하취급과 차량형태가 출하돈의 스트레스와 도체품질에 미치는 영향)

  • Kim, Doo-Hwan;Song, Jun-Ik;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.101-106
    • /
    • 2011
  • One hundred and forty-four cross-bred market pigs weighing approximately 110 kg were randomly divided into four groups in a 2 (handling stress; minimal vs stimulated) ${\times}$ 2 (transport vehicle type; enclosed box vs conventional open) factorial arrangement of treatments. The stimulated handling stress group received overally rough handling including electric prod stimulation during loading, transport and lairage at least once at each step. All the animals received 3-h lairage prior to slaughter. Blood and longissimus dorsi muscle (LM) samples were taken at slaughter and after overnight chilling of the carcass, respectively. Plasma concentrations of stress indicators glucose, cortisol, creatine kinase and lactate dehydrogenase were greater in the stimulated vs minimal handling stress group. There were no interactions between the handling stress and transport vehicle type in their effects on these blood variables. The incidence of pale, soft and exudative (PSE) carcass and drip loss of LM, 24-h postmortem LM pH and color including the lightness and redness were not affected by the handling stress and transport vehicle type. In conclusion, results suggest that rough handling inflicts a stimulated stress on the animal, which is manifested by increased blood concentrations of stress indicators, and therefore should be avoided for animal welfare.

Antioxidant Activity of Fermented Wild Grass Extracts (산야초 발효액의 항산화 활성)

  • Lee, Young-Jun;Yoon, Bo-Ra;Kim, Dan-Bi;Kim, Myoung-Dong;Lee, Dae-Won;Kim, Jae-Keun;Lee, Ok-Hwan
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.2
    • /
    • pp.407-412
    • /
    • 2012
  • Wild grass is edible, and it grows in the mountains or field areas. Wild grass has diverse biological effects, such as antiobesity, anti-cancer, antioxidant activities and immune stimulation. Currently, many studies are aimed at enhancing the efficacy of medicinal foods on biological activity using a bioconversion technology, including the fermentation process. In this study, the quality characteristics and antioxidative activity of the fermented wild grass was investigated. The antioxidant activity of fermented wild grass was assessed by various radical scavenging assays using DPPH(2,2-diphenyl-1-picrylhydrazyl), FRAP(ferric ion reducing antioxidant power), reducing power, and ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)). Moisture contents of the fermented wild grass is $49.6{\pm}0.06%$. Contents of crude ash, crude protein, and crude fat were $0.65{\pm}0.01$, $0.65{\pm}0.04$, and $3.3{\pm}0.59%$, respectively. Moreover, fermented wild grass showed that the hunter's color values were 80.36(lightnees), 11.47(redness), and 44.53(yellowness), respectively. Total phenolic contents of the fermented wild grass was $1,185{\pm}159{\mu}g$ GAE(gallic acid equivalent)/g. The antioxidative activities of the fermented wild grass were significantly increased in a dose dependent manner. In addition, fermented wild grass did not show any cytotoxicity up to 500 ${\mu}g/m{\ell}$. However, the anti-adipogenic effect of the fermented wild grass extract was barely detectable. This antioxidant potential is partly due to the phenolic compounds that are present in the fermented wild grass extracts.

Characterization of Rabbit Retinal Ganglion Cells with Multichannel Recording (다채널기록법을 이용한 토끼 망막 신경절세포의 특성 분석)

  • Cho Hyun Sook;Jin Gye-Hwan;Goo Yong Sook
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.228-236
    • /
    • 2004
  • Retinal ganglion cells transmit visual scene as an action potential to visual cortex through optic nerve. Conventional recording method using single intra- or extra-cellular electrode enables us to understand the response of specific neuron on specific time. Therefore, it is not possible to determine how the nerve impulses in the population of retinal ganglion cells collectively encode the visual stimulus with conventional recording. This requires recording the simultaneous electrical signals of many neurons. Recent advances in multi-electrode recording have brought us closer to understanding how visual information is encoded by population of retinal ganglion cells. We examined how ganglion cells act together to encode a visual scene with multi-electrode array (MEA). With light stimulation (on duration: 2 sec, off duration: 5 sec) generated on a color monitor driven by custom-made software, we isolated three functional types of ganglion cell activities; ON (35.0$\pm$4.4%), OFF (31.4$\pm$1.9%), and ON/OFF cells (34.6$\pm$5.3%) (Total number of retinal pieces = 8). We observed that nearby neurons often fire action potential near synchrony (< 1 ms). And this narrow correlation is seen among cells within a cluster which is made of 6~8 cells. As there are many more synchronized firing patterns than ganglion cells, such a distributed code might allow the retina to compress a large number of distinct visual messages into a small number of ganglion cells.

  • PDF

Effect of Gibberellin Paste on the Fruit Growth and Maturation in 'Hosui' Pears (Gibberellin 처리(處理)가 배 '풍수(豊水)' 과실(果實)의 생장(生長) 및 성숙현상(成熟現想)에 미치는 영향(影響))

  • Lee, Jae Chang;Park, Soon Hee;Kwon, Oh Won;Hwang, Yong Soo
    • Korean Journal of Agricultural Science
    • /
    • v.19 no.1
    • /
    • pp.9-15
    • /
    • 1992
  • This experiment was conducted to find the effect of gibberellin paste on the growth and maturation of 'Hosui' pear fruit and to develop a cultural technique in the middle area of Korea, where fruit quality is often poor due to the short growing season. The application of $GA_{3+4+7}$ paste on the petioles at the young stage of development resulted in the early increase of fruit diameter and weight. Although fruit firmness was slightly low by the $GA_{3+4+7}$ paste treatment, compared to that of control, there were no differences in other quality actors such as soluble solid content and acidity. However, $GA_3$ alone did not affect the fruit growth and quality. Are increase of ethylene evolution of fruit was not confirmed hut ground color development was hastened, resulting in the stimulation of maturity by 3~5 days. Thus, these results may be applicable to the production of high quality 'Hosui' pears in the area where growing season is relatively short.

  • PDF

A Study on Sensibility Evaluation of Ceramic Surface: Comparison between Tactility and Visual Tactility (세라믹 표면의 감성 평가 연구: 촉감과 시각적 촉감의 비교를 중심으로)

  • Kim, Jihyun;Song, Min Jeong
    • Science of Emotion and Sensibility
    • /
    • v.19 no.2
    • /
    • pp.101-112
    • /
    • 2016
  • Selecting appropriate materials can be significantly important to make different image in the product and also give distinguished express to the users. A material for the ceramic product surface consists of the combination between a glaze and a body, and each attribution of materials and the way of the combination creates different texture and color. This study analyzes the difference between visually and tactually sensibility of ceramic surface to through the simulating both visual and tactual stimulation by verbal evaluation method. Totally 13 adjectives are selected from homepage of local and global ceramic product brand. And totally 12 ceramic samples are created with the consideration of color, glossiness and roughness. These 12 samples are the combination between four ceramic bodies (White porcelain, Celadon_c, Sancheong and Black soil) and three glazes (Transparent, Celadon_g, Black glaze). The respondents of first survey were asked to rub, touch and hold before evaluating the sensibility of ceramic surface and other respondents of second survey were asked to evaluate visual images of 9 samples which showed meaningfully difference from first survey. The surface which scored the highest sensibility with the first survey was 'pure' on a surface of White porcelain body with Transparent glaze, and the lowest was also 'pure' on a surface of Black soil body with Transparent glaze. The highest score in the second survey was the same result as the first survey, but the lowest scored 'casual' and the surface was Black soil body with Celadon glaze. By the comparison with two survey results, not every sensibility is same result shown as the first survey and the second survey, but the tactile sensibilities such as 'artistic', 'luxurious', 'sensuous', 'romantic' and 'mysterious' can be experienced by via visual materials of ceramic surfaces.

Effects of Fasting and Handling Stress on Plasma Concentrations of Glucose, Stress-associated Enzymes and Carcass Quality of Market Pigs (절식과 출하취급이 출하돈의 스트레스 관련 혈액성상과 도체품질에 미치는 영향)

  • Kim, D.H.;Ha, D.M.;Seo, J.T.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.81-88
    • /
    • 2007
  • One hundred and forty-four cross-bred market pigs weighing approximately 110 kg were randomly divided into six groups in a 3 (duration of fasting prior to loading; 0, 12 and 24 h) ${\times}$ 2 (handling stress; minimal vs stimulated handling stress) factorial arrangement of treatments. The stimulated handling stress group received overally rough handling including electric prod stimulation during loading, transport and lairage at least once at each step. All the animals received 3-h lairage prior to slaughter. Blood and longissimus dorsi muscle (LM) samples were taken at slaughter and after overnight chilling of the carcass, respectively. Mean plasma glucose concentration, as expected, was less in the 12 h- or 24 h-fasting group than in the 0 h-fasting, whereas cortisol concentration was greater (P<0.05) in the 24 h- vs 0 h-fasting group. Plasma concentrations of stress indicators glucose, cortisol, creatine kinase and lactate dehydrogenase were greater in the stimulated vs minimal handling stress group. There were no interactions between the duration of fasting and handling stress in their effects on these blood variables. The incidence of pale, soft and exudative (PSE) carcass and drip loss of LM were reduced in the 12 h- or 24 h- vs 0 h-fasting group, whereas the 24-h postmortem LM pH and color including the lightness and redness were not affected by the duration of fasting. The incidence of PSE carcass and physicochemical characteristics of LM, however, were not changed by the stimulated vs minimal handling stress. In conclusion, results suggest that fasting the market pig overnight prior to transport is desirable in terms of reducing the incidence of PSE carcass. Rough handling of market pigs may not affect the carcass quality of the animals when an enough lairage time is provided. However, rough handling inflicts a stimulated stress on the animal, which is manifested by increased blood concentrations of stress indicators, and therefore should be avoided fer animal welfare.

  • PDF

f-MRI with Three-Dimensional Visual Stimulation (삼차원 시각 자극을 이용한 f-MRI 연구)

  • Kim C.Y.;Park H.J.;Oh S.J.;Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.24-29
    • /
    • 2005
  • Purpose : Instead of conventional two-dimensional (2-D) visual stimuli, three-dimensional (3-D) visual stimuli with stereoscopic vision were employed for the study of functional Magnetic Resonance Imaging (f-MRI). In this paper f-MRI with 3-D visual stimuli is investigated in comparison with f-MRI with 2-D visual stimuli. Materials and Methods : The anaglyph which generates stereoscopic vision by viewing color coded images with red-blue glasses is used for 3-D visual stimuli. Two-dimensional visual stimuli are also used for comparison. For healthy volunteers, f-MRI experiments were performed with 2-D and 3-D visual stimuli at 3.0 Tesla MRI system. Results : Occipital lobes were activated by the 3-D visual stimuli similarly as in the f-MRI with the conventional 2-D visual stimuli. The activated regions by the 3-D visual stimuli were, however, larger than those by the 2-D visual stimuli by $18\%$. Conclusion : Stereoscopic vision is the basis of the three-dimensional human perception. In this paper 3-D visual stimuli were applied using the anaglyph. Functional MRI was performed with 2-D and 3-D visual stimuli at 3.0 Tesla whole body MRI system. The occipital lobes activated by the 3-D visual stimuli appeared larger than those by the 2-D visual stimuli by about $18\%$. This is due to the more complex character of the 3-D human vision compared to 2-D vision. The f-MRI with 3-D visual stimuli may be useful in various fields using 3-D human vision such as virtual reality, 3-D display, and 3-D multimedia contents.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF