• 제목/요약/키워드: Color reproducibility

검색결과 78건 처리시간 0.023초

Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner

  • Jeon, Jin-Hun;Kim, Dong-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.214-218
    • /
    • 2016
  • PURPOSE. We assessed the repeatability and reproducibility of abutment teeth dental impressions, digitized with a blue light scanner, by comparing the discrepancies in repeatability and reproducibility values for different types of abutment teeth. MATERIALS AND METHODS. To evaluate repeatability, impressions of the canine, first premolar, and first molar, prepared for ceramic crowns, were repeatedly scanned to acquire 5 sets of 3-dimensional data via stereolithography (STL) files. Point clouds were compared and the error sizes were measured (n=10, per type). To evaluate reproducibility, the impressions were rotated by $10-20^{\circ}$ on the table and scanned. These data were compared to the first STL data and the error sizes were measured (n=5, per type). One-way analysis of variance was used to assess the repeatability and reproducibility of the 3 types of teeth, and Tukey honest significant differences (HSD) multiple comparison test was used for post hoc comparisons (${\alpha}=.05$). RESULTS. The differences with regard to repeatability were 4.5, 2.7, and $3.1{\mu}m$ for the canine, premolar, and molar, indicating the poorest repeatability for the canine (P<.001). For reproducibility, the differences were 6.6, 5.8, and $11.0{\mu}m$ indicating the poorest reproducibility for the molar (P=.007). CONCLUSION. Our results indicated that impressions of individual abutment teeth, digitized with a blue light scanner, had good repeatability and reproducibility.

홍화 황색소를 이용한 모염색의 최적화 (Optimization of Wool Dyeing with Yellow Dye from Carthamus Tinctorius L.)

  • 신윤숙;손경희;류동일
    • 한국의류학회지
    • /
    • 제33권12호
    • /
    • pp.1971-1978
    • /
    • 2009
  • 본 연구는 염색 공정의 표준화와 재현성을 확립하기 위해 홍화 황색소의 모섬유에 대한 염색성을 조사하는데 목적이 있다. 홍화 황색소는 물로 추출한 후 농축, 동결건조하여 분말상태로 만들어 사용하였다. 염색 온도 및 시간, 염료 농도, 염액의 pH 등에 따른 염착성과 색상 변화에 대해 조사하였으며, 세탁 및 일광견뢰도를 평가하였다. 염착량은 $50^{\circ}C$까지 서서히 증가하다가 이후 급격히 증가하여 $90^{\circ}C$에서 최고 값을 나타냈다. 염착은 초기 10분 이내에 빠르게 일어났으며 이후 서서히 증가하다가 40~60분 사이에 평형에 도달하였다. 염료 농도가 증가함에 따라 염착량이 계속 증가하여 점점 진하고 어두운 노랑색이 되었다. 산성 조건에서 염착이 잘 되었으며 pH 3.0에서 최대염착량을 보였다. 얻은 결과를 근거로 최적 염색 조건은 $90^{\circ}C$, 40분, pH 3.5으로 설정하였으며, 최적 조건에서 염색한 시료들 간의 색차는 0.53~1.75로서 재현성이 우수하였다. 후매염은 염착성 증진에 효과가 없었으나, 다양한 톤과 농담의 노랑색을 얻을 수 있었다. 세탁(드라이크리닝)견뢰도는 4/5등급으로 좋은 편이었으나 20시간 조사 후 일광견뢰도는 Fe과 Cu매염한 경우 3/4등급으로 색차가 가장 적었다. 결과를 종합해 볼 때 매염제가 색상톤을 다양하게 하는 효과는 있었지만, 염착량과 견뢰도 향상에 기여하지 못하였다. 홍화 황색소는 모염색에서 매염제 없이 만족스러운 결과를 얻을 수 있고, 따라서 환경에 피해를 주지 않을 것으로 사료된다.

백색광과 청색광 스캐너를 이용한 지대치 인상체 스캐닝의 반복재현성 비교 (Comparison of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners)

  • 전진훈;성환경;민병국;황재선;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.213-218
    • /
    • 2015
  • Purpose: The purpose of this study compared of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners. Methods: To evaluate reproducibility with white and blue light scanners, the impression of premolar were rotated by $10^{\circ}{\sim}20^{\circ}$ and scanned. These data were compared with the first 3-D data (STL file), and the error sizes were measured (n=5). Independent t test was used to evaluation the reproducibility of impression of premolar with white versus blue light scanners through discrepancies of mean, RMS (${\alpha}=0.05$). Results: Discrepancies of mean with regard to reproducibility were $11.2{\mu}m$, $5.8{\mu}m$, respectively, with white and blue light scanners (p<0.047). And discrepancies of RMS with regard to reproducibility were $33.4{\mu}m$, $18.8{\mu}m$, respectively, with white and blue light scanners (p<0.045). Conclusion: Our results indicate a good reproducibility of prepared tooth impression digitized with blue light scanner more than that with white light scanner.

Comparison of the reproducibility of results of a new peri-implantitis assessment system (implant success index) with the Misch classification

  • Abrishami, Mohammad Reza;Sabour, Siamak;Nasiri, Maryam;Amid, Reza;Kadkhodazadeh, Mahdi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권2호
    • /
    • pp.61-67
    • /
    • 2014
  • Objectives: The present study was conducted to determine the reproducibility of peri-implant tissue assessment using the new implant success index (ISI) in comparison with the Misch classification. Materials and Methods: In this descriptive study, 22 cases of peri-implant soft tissue with different conditions were selected, and color slides were prepared from them. The slides were shown to periodontists, maxillofacial surgeons, prosthodontists and general dentists, and these professionals were asked to score the images according to the Misch classification and ISI. The intra- and inter-observer reproducibility scores of the viewers were assessed and reported using kappa and weighted kappa (WK) tests. Results: Inter-observer reproducibility of the ISI technique between the prosthodontists-periodontists (WK=0.85), prosthodontists-maxillofacial surgeons (WK=0.86) and periodontists-maxillofacial surgeons (WK=0.9) was better than that between general dentists and other specialists. In the two groups of general dentists and maxillofacial surgeons, ISI was more reproducible than the Misch classification system (WK=0.99 versus WK non-calculable, WK=1 and WK=0.86). The intra-observer reproducibility of both methods was equally excellent among periodontists (WK=1). For prosthodontists, the WK was not calculable via any of the methods. Conclusion: The intra-observer reproducibility of both the ISI and Misch classification techniques depends on the specialty and expertise of the clinician. Although ISI has more classes, it also has higher reproducibility than simpler classifications due to its ability to provide more detail.

pH Control for Dyebath Reuse in Dyeing of Polyamide with Binary Mixtures of Acid Dyes

  • Koh, Joonseok;Park, Sang Hyuck;Shim, Goo Hwan;Cho, Dae Hwan;Kim, Jae Pil
    • Fibers and Polymers
    • /
    • 제5권2호
    • /
    • pp.110-116
    • /
    • 2004
  • Hydrolyzable organic esters were compared with ammonium sulphate as an acid donor for the pH control in dye-bath-reuse system of acid dyes mixtures. The ability of pH control, levelness, dyeing properties and reproducibility in dye-bath-reuse system were investigated comparatively. Hydrolyzable organic esters showed higher exhaustion and color yield than ammonium sulphate. In addition, hydrolyzable organic ester exhibited very low conductivity less than 0.5 mS, while ammonium sulphate give high conductivity. However, we could not observe any difference in levelness of dyed samples between two kinds of acid donors in laboratory scale dyeing. Over 10 cycles of reuse, hydrolyzable organic esters showed higher reproducibility than ammonium sulphate. No deterioration of the color fastness and levelness occurs over 10 cycles of reuse.

Optical Films for Mobile LCD

  • Higashi, Kohji;Honda, Masaru;Matsumoto, Kohji;Sairai, Takuya
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.901-904
    • /
    • 2002
  • Display performance of mobile LCDs has been improved according to broadening of their application. But there are many demands from market, such as contrast improvement (high color reproducibility), higher efficiency of light usage, thickness reduction, widening its viewing angle and so on. To respond them we have been developing many new types of films. In this paper we introduce new high contrast white polarizers for better color reproducibility, and new film construction for higher light efficiency.

  • PDF

Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.71-78
    • /
    • 2014
  • PURPOSE. The objective of this study was to evaluate the clinical acceptability of all-ceramic crowns fabricated by the digital veneering method vis-$\grave{a}$-vis the traditional method. MATERIALS AND METHODS. Zirconia specimens manufactures by two different manufacturing method, conventional vs digital veneering, with three different thickness (0.3 mm, 0.5 mm, 0.7 mm) were prepared for analysis. Color measurement was performed using a spectrophotometer for the prepared specimens. The differences in shade in relation to the build-up method were calculated by quantifying ${\Delta}E^*$ (mean color difference), with the use of color difference equations representing the distance from the measured values $L^*$, $a^*$, and $b^*$, to the three-dimensional space of two colors. Two-way analysis of variance (ANOVA) combined with a Tukey multiple-range test was used to analyze the data (${\alpha}$=0.05). RESULTS. In comparing means and standard deviations of $L^*$, $a^*$*, and $b^*$ color values there was no significant difference by the manufacturing method and zirconia core thickness according to a two-way ANOVA. The color differences between two manufacturing methods were in a clinically acceptable range less than or equal to 3.7 in all the specimens. CONCLUSION. Based on the results of this study, a carefully consideration is necessary while selecting upper porcelain materials, even if it is performed on a small scale. However, because the color reproducibility of the digital veneering system was within the clinically acceptable range when comparing with conventional layering system, it was possible to estimate the possibility of successful aesthetic prostheses in the latest technology.

천연인디고를 이용한 셀룰로오스계 직물 염색의 표준화 연구: 일단계 환원/염색에 의한 마직물 염색 (Optimization of Cellulose Dyeing with Natural Indigo: Ramie dyeing by One-step Reduction/dyeing Process)

  • 손경희;신윤숙;류동일
    • 한국의류산업학회지
    • /
    • 제13권2호
    • /
    • pp.263-268
    • /
    • 2011
  • One-step reduction/dyeing method was applied for ramie dyeing with natural indigo powder. The effect of reduction/dyeing conditions including the pH of bath, dye temperature and time, and concentration of indigo powder and reduction agent on dye uptake and color properties were investigated. Regardless of addition of alkali, the dyed fabrics appeared in the PB Munsell color range(${\lambda}_{max}$: 660 nm) and the dye uptake was much higher with no addition of sodium hydroxide. Dyeing was carried out through the use of only sodium hydrosulfite in the bath. The maximum dye uptake was obtained at 60 for 30min. Saturated dye uptake was obtained at 2 g/L of sodium hydrosulfite concentration up to 2 g/ L of indigo powder. Whereas, at higher indigo powder concentration (4 g/L), more than 3 g/L of reducing agent concentration was required for obtaining the saturated dye uptake. Color reproducibility was reliable with color difference in the range of 0.03~0.16. Regardless of color strength, fastness to rubbing was acceptable with a 3/4~4/5. Fastness to washing, dry cleaning, and light of samples with low color strength were poor. Whereas, fastness to washing, dry cleaning, and light of samples with high color strength were very good.

도포법 및 침전법을 이용한 지르코니아의 색조 재현성 비교 연구 (Comparative study of color reproducibility of zirconia using a dipping method and coating method)

  • 이희정;김재홍;김웅철;김지환;김혜영
    • 대한치과기공학회지
    • /
    • 제35권3호
    • /
    • pp.185-192
    • /
    • 2013
  • Purpose: The aim of this study was to compare with color reproducibility of the coating method and dipping method using a colour liquid. Methods: Two groups of square-shaped specimens ($10mm{\times}10mm$ in diameter, 1.5mm thickness) were prepared for analysis(n=15/group). The CM(Coating Method) group was fabricated as full zirconia specimens with the coating coloring method and Group DM(Dipping Method) was prepared as specimens of 0.7 mm-thick zirconia plate using the dipping coloring method and veneered with 0.8mm-thick porcelain. Color parameters were measured with ShadeEye $NCC^{(R)}$ spectrophotometer and color differences were calculated using the equation ${\Delta}E^*= \{({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2\}^{1/2}$. Non-parametric statistical methods, the Mann-Whitney test, and the Kruskal-Wallis test were used to analyze the data. Type one error rate was set at 0.05. Results: Color difference values larger than 7 were observed between specimens with the coating method and the dipping method, which were detectable difference in a clinical setting. Conclusion: Cautious application of the coating coloring method in a clinical setting and further researches to standardize the coating method are needed.

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.