• Title/Summary/Keyword: Color Doppler

Search Result 116, Processing Time 0.025 seconds

Study on the clutter filter of color Doppler processor (칼라 도플러 프로세서의 클러터 필터에 관한 연구)

  • Bang, J.H.;Lee, K.J.;Bae, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.68-69
    • /
    • 1998
  • Discriminating the clutter signal from Doppler signal is the main function of CDP(color Doppler processor). Up to now, a general method of eliminating clutter signal is using IIR high pass filter. There are many filters that were introduced in other paper. In this paper, we propose the new method of filtering clutter signal. To the new method, we adopt an appropriate filter that can eliminate clutter filter most effectively.

  • PDF

A Case of Pseudoaneurysm of the Common Carotid Artery secondary to Deep Neck Infection (심경부 감염과 동반된 총경동맥 가성동맥류 1례)

  • 정필섭;조정석;정필상
    • Korean Journal of Bronchoesophagology
    • /
    • v.3 no.1
    • /
    • pp.159-163
    • /
    • 1997
  • The complications of deep neck infection have become much less common in the antibiotic era. The vascular complications of deep neck infection can have devasting consequences. Most commonly, the internal carotid artery is involved, although the common carotid and external carotid artery can also be affected.0 the cases of patients with a protracted course, recurrent bleeding, cranial neuropathies, or trismus, the presence of vascular complications must be considered. Appropriate imaging should be carried out to allow the localization of the infection and ascertain the status of the vessels in the neck The vascular structures can be imaged with duplex doppler or color doppler flow ultrasound to see the flow between the mass and vessels. Also angiography plays a key role in the diagnosis and management of vascular complication of deep neck infection. Prompt diagnosis and treatment of these patients is necessary to prevent significant hemmorrhagic complications. We experienced a case of pseudoaneurysm of the common carotid artery secondary to deep neck infection treated successfully with surgical excision in 45-year-old-male.

  • PDF

In vivo Evaluation of Flow Estimation Methods for 3D Color Doppler Imaging

  • Yoo, Yang-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.177-186
    • /
    • 2010
  • In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.

Effects of anesthetics on resistive index of the medial long posterior ciliary artery and ophthalmic artery using color doppler imaging

  • Choi, Ho-jung;Lee, Young-won;Yoon, Jung-hee;Yeon, Seong-chan;Lee, Hyo-jong;Lee, Hee-chun
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.3
    • /
    • pp.423-427
    • /
    • 2005
  • Color Doppler imaging (CDI) was carried out to evaluate the anesthetics effect on ophthalmic circulation using CDI-derived resistive index (RI) values. CDI was preformed on 24 dogs, and RI values were calculated for the medial long posterior ciliary artery (mLPCA) and ophthalmic artery (OA) before and after administration of anesthetics. After administration of benoxinate or acepromazine, a significant change of the mLPCA RI was not found. But, a significant decrease of the RI following ketamine (p < 0.001) or xylazine (p < 0.01) administration could be observed as compared with the self-control. Mean RI value of OA also showed this same trend. Intraocular pressure was significantly decrease following benoxinate (p < 0.01), acepromazine (p < 0.01), and xylazine (p < 0.001) administration within normal range. The results suggest that some anesthetics influence on ophthalmic vascular resistance. Therefore, chemical restraint was carefully used in clinical application of CDI-derived RI measurement. Particularly, benoxinate and acepromazine is useful chemical restraint without a change of the ophthalmic vascular resistance.

Use of ultrasound Doppler to determine tooth vitality in a discolored tooth after traumatic injury: its prospects and limitations

  • Cho, Yong-Wook;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.68-73
    • /
    • 2014
  • When a tooth shows discoloration and does not respond to the cold test or electric pulp test (EPT) after a traumatic injury, its diagnosis can be even more difficult due to the lack of proper diagnostic methods to evaluate its vitality. In these case reports, we hope to demonstrate that ultrasound Doppler might be successfully used to evaluate the vitality of the tooth after trauma, and help reduce unnecessary endodontic treatments. In all three of the present cases, the teeth were discolored after traumatic injuries and showed negative responses to the cold test and EPT. However, they showed distinctive vital reactions in the ultrasound Doppler test during the whole observation period. In the first case, the tooth color returned to normal, and the tooth showed a positive response to the cold test and EPT at 10 wk after the injury. In the second case, the tooth color had returned to its normal shade at 10 wk after the traumatic injury but remained insensitive to the cold test and EPT. In the third case, the discoloration was successfully treated with vital tooth bleaching.

Real Time Moving Object Detection Based on Frame Difference and Doppler Effects in HSV color model (HSV 컬러 모델에서의 도플러 효과와 영상 차분 기반의 실시간 움직임 물체 검출)

  • Sanjeewa, Nuwan;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.4
    • /
    • pp.77-81
    • /
    • 2014
  • This paper propose a method to detect moving object and locating in real time from video sequence. first the proposed method extract moving object by differencing two consecutive frames from the video sequence. If the interval between captured two frames is long, it cause to generate fake moving object as tail of the real moving object. secondly this paper proposed method to overcome this problem by using doppler effects and HSV color model. finally the object segmentation and locating is done by combining the result that obtained from steps above. The proposed method has 99.2% of detection rate in practical and also this method is comparatively speed than other similar methods those proposed in past. Since the complexity of the algorithm is directly affects to the speed of the system, the proposed method can be used as low complexity algorithm for real time moving object detection.

Diagnosis in Canine Tricuspid Valve Dysplasia (개에서 삼첨판 이형성의 증례)

  • 최호정;정동희;최윤주;신남식;권오경;최민철;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.264-267
    • /
    • 2002
  • Tricuspid valve dysplasia was diagnosed in 2 month-old german shepherd dog. Radiographic and echocardiographic examination was performed and they revealed severe dilatation of the right atrium, dilatation of the right ventricle, and septal leaflet tethered to the right side of the septum. On Doppler echocardiography, tricuspid valve incompetence was detected, flow velocity ranging from 3-4 m/sec. Color Doppler examination showed large turbulent jet in the right atrium.

A New Method for Extending Doppler Mean Frequency in Ultrasonic Imaging Systems (초음파 영상 시스템에서 새로운 도플러 평균주파수 확장 방법)

  • Kwon, Sung-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1047-1056
    • /
    • 2007
  • Basically, an ultrasonic imaging system has two fundamental imaging modes available. One is the B-mode imaging modality which provides an image of reflection coefficient, and the other is the Doppler color flow mode that maps blood flow inside the human heart and blood vessels. This paper presents a new method of detecting and compensating for aliasing that occurs when the Doppler frequency exceeds one-half of the pulse-repetition frequency (PRF). Its validity is shown by computer simulation. The new method not only extends the measurable Doppler frequency, but also helps to reduce the effect of noise. The results show that the aliasing can be compensated for correctly fur signal-to-noise ratios down to 20 dB.

  • PDF

The correlation of the skin color to the blood circulation on the face of Korean female between the ages of 30 and 45 (30${\sim}$40대 한국 여성의 안색과 혈행의 상관성 연구)

  • Kim, Eun-Joo;Roh, Ho-Sik;Kim, Su-Jong;Moon, Eun-Jeong;Kim, Duck-Hee;Kim, Han-Kon;Cho, Ga-Young
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 2008
  • Objectives : We investigated the correlation of the skin color to blood circulation on the face of Korean female by noninvasive-skin measuring devices. Methods : Korean female(37.47${\pm}$3.66 years, n=36) aged 30-45 years were participated in this study. We measured the skin color of the face with Spectrophotometer CM2600d (Minolta, Japan) and the skin blood flow with Laser Doppler Imaging-Periscan PIM II (Perimed AB, Sweden). The skin color and blood circulation of three groups (30-35 years, 36-40 years, 41-45 years) divided on age were analyzed by paired-t test and regression analysis. Results : The L* values of the skin were decreased and the a* values were increased significantly with age. This means that the more age increase, the more the skin is dark and red. But the skin blood flow was not significantly different with age and skin color. Conclusions : In the oriental medicine, It was reported that the face of the female over 35 years is changed gradually haggard and the blood circulation is decreased. In our study, the blood circulation was not changed and the skin color was dark and red with increasing the age. We think this symptom resulted from the better nutrition than the past, the change of the blood-quality and this changes were too sensitive to be measured by Laser Doppler Imaging system.

  • PDF