• Title/Summary/Keyword: Color Calibration

Search Result 209, Processing Time 0.025 seconds

Moon Imaging for the Calibration of the COMS Meteorological Imager (천리안 위성의 기상탑재체 보정을 위한 달 영상 획득 방안)

  • Park, Bong-Kyu;Yang, Koon-Ho
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.44-50
    • /
    • 2010
  • COMS accommodates multiple payloads; Meteorological Image(MI), Ocean Color Imager(GOCI) and Ka-band communication payloads. In order to improve the quality of MI visible channel, the moon image has been taken into account as backup reference in addition to Albedo monitoring. However, obtaining the moon image by adding special mission schedule is not recommended after IOT, because we may miss chances to obtain meteorological images during the time slots for special imaging. As an alternative solution, an approach extracting moon image from MI FD(Full Disk) image has been proposed when the moon is positioned near to the earth. However, prediction of acquisition time of moon image is somewhat difficult as the moon moves while the MI is scanning type sensor. And the moon can not be seen when it is behind the earth or outside of FD field of view. This paper discusses how effectively the moon can be detected by the MI FD imaging. For that purpose, this paper describes an approach taken to predict the time when the moon image is achievable and then introduces the results obtained from computer simulation.

Observational Evidence of Merging and Accretion in the Milky Way Galaxy from the Spatial Distribution of Stars in Globular Clusters

  • Chun, Sang-Hyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.76-76
    • /
    • 2013
  • The current hierarchical model of galaxy formation predicts that galaxy halos contain merger relics in the form of long stellar streams. In order to find stellar substructures in galaxy, we focused our investigation on the stellar spatial density around globular clusters and on the quantitative properties of the evolved sequences in the color-magnitude diagrams (CMDs). First, we investigated the spatial configuration of stars around five metal-poor globular clusters in halo region (M15, M30, M53, NGC 5053, and NGC 5466) and one metal-poor globular cluster in bulge region (NGC 6626). Our findings indicate that all of these globular clusters show strong evidence of extratidal features in the form of extended tidal tails around the clusters. The orientations of the extratidal features show the signatures of tidal tails tracing the clusters' orbits and the effects of dynamical interactions with the galaxy. These features were also confirmed by the radial surface density profiles and azimuthal number density profiles. Our results suggest that these six globular clusters are potentially associated with the satellite galaxies merged into the Milky Way. Second, we derived the morphological parameters of the red giant branch (RGB) from the near-infrared CMDs of 12 metal-poor globular clusters in the Galactic bulge. The photometric RGB shape indices such as colors at fixed magnitudes, magnitudes at fixed colors, and the RGB slope were measured for each cluster. The magnitudes of the RGB bump and tip were also estimated. The derived RGB parameters were used to examine the overall behavior of the RGB morphology as a function of cluster metallicity. The behavior of the RGB shape parameters was also compared with the previous observational calibration relation and theoretical predictions of the Yonsei-Yale isochrones. Our results of studies for stellar spatial distribution around globular clusters and the morphological properties of RGB stars in globular clusters could add further observational evidence of merging scenario of galaxy formation.

  • PDF

Nondestructive determination of physico-chemical properties in compost by NIRS

  • Seo, Sang-Hyun;Lee, Chang-Hee;Park, Sung-Hun;Cho, Rae-Kwang;Park, Woo-Churl
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1622-1622
    • /
    • 2001
  • The purpose of this research was to develop a the reflection technique with near infrared (NIR) radiation for estimating physico-chemical properties in compost. The composts (cattle, pig, chicken and waste composts) were air dried and then ground to pass through a 0.5 or 2mm sieve for the physico-chemical properties and spectroscopic determinations. The physico-chemical properties of compost were shown high values ; moisture(30-60%), T-N(0.8-2.9%), organic matter(29-89%), pH(5.89-9.60) K$_2$O(0.27-5.66%), P2O$\sub$5/(0.07-2.62%), CaO(0.03-4.80%), MgO(0.09-1.56%), NaCl(0.01-1.13%), EC(1.41-13.76dS/m). Generally, we should select a simple calibration and prediction method for determining physico-chemical properties in compost under similar accuracy and precision of prediction. It should be remembered that the NIRS approach will never replace the traditional methods. However, NIRS technique may be an effective method for rapid and nondestructive measurements of a large number of compost samples. Near infrared reflectance spectra of composts was obtained by Infra Alyzer 500 scanning spectrophotometer at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of physico-chemical properties and humic acid contents in composts. The standard error of prediction(SEP) for finely sized sample(<0.5mm) and coarsely sized sample(<2mm) did not show much difference. The NIR instrument of filter type showed the same accuracy of the monochromator scanning type to estimate the compost properties. The results summarized that NIR spectroscopy can be used as a routine testing method to determine quantitatively the OM, moisture, T-N, color, pH, cation content in the compost samples nondestructively.

  • PDF

Development of a Ubiquitous Vision System for Location-awareness of Multiple Targets by a Matching Technique for the Identity of a Target;a New Approach

  • Kim, Chi-Ho;You, Bum-Jae;Kim, Hag-Bae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.68-73
    • /
    • 2005
  • Various techniques have been proposed for detection and tracking of targets in order to develop a real-world computer vision system, e.g., visual surveillance systems, intelligent transport systems (ITSs), and so forth. Especially, the idea of distributed vision system is required to realize these techniques in a wide-spread area. In this paper, we develop a ubiquitous vision system for location-awareness of multiple targets. Here, each vision sensor that the system is composed of can perform exact segmentation for a target by color and motion information, and visual tracking for multiple targets in real-time. We construct the ubiquitous vision system as the multiagent system by regarding each vision sensor as the agent (the vision agent). Therefore, we solve matching problem for the identity of a target as handover by protocol-based approach. We propose the identified contract net (ICN) protocol for the approach. The ICN protocol not only is independent of the number of vision agents but also doesn't need calibration between vision agents. Therefore, the ICN protocol raises speed, scalability, and modularity of the system. We adapt the ICN protocol in our ubiquitous vision system that we construct in order to make an experiment. Our ubiquitous vision system shows us reliable results and the ICN protocol is successfully operated through several experiments.

  • PDF

Real-time Implementation and Application of Pointing Region Estimation System using 3D Geometric Information in Real World (실세계 3차원 기하학 정보를 이용한 실시간 지시영역 추정 시스템의 구현 및 응용)

  • Han, Yun-Sang;Seo, Yung-Ho;Doo, Kyoung-Soo;Kim, Jin-Tae;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.29-36
    • /
    • 2008
  • In this paper we propose a real-time method to estimate a pointing region from two camera images. In general, a pointing target exists in the face direction when a human points to something. Therefore, we regard the direction of pointing as the straight line that connects the face position with the fingertip position. First, the method extracts two points in the face and the fingertips region by using detecting the skin color of human being. And we used the 3D geometric information to obtain a pointing detection and its region. In order to evaluate the performance, we have build up an ICIGS(Interactive Cinema Information Guiding System) with two camera and a beam project.

STATUS OF GOCI DATA PROCESSING SYSTEM(GDPS) DEVELOPMENT

  • Han, Hee-Jeong;Ahn, Yu-Hwan;Ryu, Joo-Hyung
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.159-161
    • /
    • 2007
  • Geostationary Ocean Color Imager (GOCI), the world-first ocean remote sensing instrument on geostationary Communication, Ocean, Meteorological Satellite (COMS), will be able to take a picture of a large region several times a day (almost with every one hour interval). We, KORDI, are in charge for developing the GOCI data processing system (GDPS) which is the basic software for processing the data from GOCI. The GDPS will be based on windows operating system to produce the GOCI level 2 data products (useful for oceanographic environmental analysis) automatically in real-time mode. Also, the GDPS will be a user-interactive program by well-organized graphical user interfaces for data processing and visualization. Its products will be the chlorophyll concentration, amount of total suspended sediments (TSS), colored dissolved organic matters (CDOM) and red tide from water leaving radiance or remote sensing reflectance. In addition, the GDPS will be able to produce daily products such as water current vector, primary productivity, water quality categorization, vegetation index, using individual observation data composed from several subscenes provided by GOCI for each slit within the target area. The resulting GOCI level 2 data will be disseminated through LRIT using satellite dissemination system and through online request and download systems. This software is carefully designed and implemented, and will be tested by sub-contractual company until the end of this year. It will need to be updated in effect with respect to new/improved algorithms and the calibration/validation activities.

  • PDF

Image Discriminal Analysis for Detecting a Esophagitis (식도염 진단을 위한 영상 판별분석)

  • Seo K. W.;Lee C. W.;Kim W.;Lee S. Y.;Lee D. W.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.545-550
    • /
    • 2004
  • An Image processing algorithm was developed and tested to detect abnormal parts, such as esophagitis, with the information on the color and the texture in a digital clinic endoscopic image by using discriminal analysis. In order to develope the algorithm, the critical parameters from many parameters were found to distinguish between normal and abnormal part in the various images. The Inflammation and ulceration which are very important diagnostic indexes were detected by the algorithm. The algorithm proved to a reliable program for detecting abnormal parts with 20 images. A success rate was 92.8% and 92.4% in the calibration stage and the validation stage by using the algorithm with discriminal analysis.

Quantitative Determination of Total Bile Acids from Bezoar and Bezoar-containing Liquid Preparation by Enzymatic Technique (효소반응법을 이용한 우황 및 우황함유 액상 제제 중 총담즙산의 정량)

  • Ha, In-Sik;Kim, Seung-Hwan;Cha, Bong-Jin;Kwon, Jong-Won;Yang, Joong-Ik;Min, Shin-Hong
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.2
    • /
    • pp.67-71
    • /
    • 1991
  • A simple and sensitive method was developed for the quantification of free and conjugated bile acids in bezoar without prior hydrolysis. $3{\alpha}-Hydroxy$ bile acids are first oxidized to 3-keto bile acids in the reaction catalyzed by $3{\alpha}-hydroxysteroid$ $dehydrogenase(3{\alpha}-HSD)$. During this oxidative reaction, an equimolar quantity of nicotinamide adenine dinucleotide(NAD) is reduced to NADH and subsequently oxidized to NAD with concomitant reduction of nitrotetrazolium blue(NTB) to diformazan by the catalytic action of diaphorase. The diformazan has an absorbance maximum at 540 nm. The intensity of the color produced is directly proportional to bile acids concentration in the bezoar extracts. The optimum conditions for the enzymatic reaction such as effects of reaction time, reaction temperature and pH, and stability were investigated. Calibration plots for the sodium chelate observed to be linear and intra-, inter-assay analytical recovery of bile acids averaged $97.65{\pm}3.4%(S.D.)$. Therefore, it is considered that the quality control of total bile acids from bezoar or bezoar-containing liquid preparation using this simple and sensitive assay system will be acceptable. Also current bezoars and bezoar-containing liauid preparations were examined their total bile acids from this method.

  • PDF

Evaluation for Long-term Stability of EGCG Rich Green Tea Extract (EGTE) (신규 건강기능식품소재 'EGCG 고함유 녹차추출물(EGTE)'의 장기안정성 평가)

  • Cheon, Se In;Heo, Eun Ji;Yoon, Min Ji;Choi, Sang Un;Ryu, Geon-Seek;Ryu, Shi Yong
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.4
    • /
    • pp.328-335
    • /
    • 2018
  • 'EGCG(epigallocatechin gallate) rich Green Tea extract(EGTE)' was prepared by a convenient chromatographical manner using water and alcohol which was regarded as the most suitable and appropriate process for food manufacturing. The EGCG content in EGTE was estimated above 97%. Analysis of polyphenol components in green tea, i.e., catechin(C), epigallocatechin(EGC), epicatechin(EC), epigallocatechin gallate(EGCG), epicatechin gallate(ECG) and caffeine was performed by HPLC. The optimized HPLC method exhibited a good linearity of calibration curve, accuracy and precision. The long-term stability evaluation of EGTE was carried out with a powdered formulation and solution formulation by estimating the color change and measuring the EGCG content by HPLC analysis for one year. The EGCG content of the powdered EGTE stored in a transparent bottle at room temperature was retained over 97% at the end of the experimental period. The EGCG content of 0.1% water solution of EGTE stored in a transparent bottle at RT were observed to decrease below 30%, whereas that stored at $2^{\circ}C$ retained over 70%, respectively. These results suggested that a powdered formulation could be recommended for the commercialized nutraceutical product of EGTE rather than a solution formulation.

Development of a soil total carbon prediction model using a multiple regression analysis method

  • Jun-Hyuk, Yoo;Jwa-Kyoung, Sung;Deogratius, Luyima;Taek-Keun, Oh;Jaesung, Cho
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.891-897
    • /
    • 2021
  • There is a need for a technology that can quickly and accurately analyze soil carbon contents. Existing soil carbon analysis methods are cumbersome in terms of professional manpower requirements, time, and cost. It is against this background that the present study leverages the soil physical properties of color and water content levels to develop a model capable of predicting the carbon content of soil sample. To predict the total carbon content of soil, the RGB values, water content of the soil, and lux levels were analyzed and used as statistical data. However, when R, G, and B with high correlations were all included in a multiple regression analysis as independent variables, a high level of multicollinearity was noted and G was thus excluded from the model. The estimates showed that the estimation coefficients for all independent variables were statistically significant at a significance level of 1%. The elastic values of R and B for the soil carbon content, which are of major interest in this study, were -2.90 and 1.47, respectively, showing that a 1% increase in the R value was correlated with a 2.90% decrease in the carbon content, whereas a 1% increase in the B value tallied with a 1.47% increase in the carbon content. Coefficient of determination (R2), root mean square error (RMSE), and mean absolute percentage error (MAPE) methods were used for regression verification, and calibration samples showed higher accuracy than the validation samples in terms of R2 and MAPE.