NUMERICAL STUDY ON THE OPTIMAL DESIGN OF SPRAY SYSTEM IN PACKED BED SCRUBBER (충진층식 스크러버의 스프레이 시스템 최적 설계에 대한 수치해석적 연구)

  • Ko, S.W.;Ro, K.C.;Ryou, H.S.
    • Journal of computational fluids engineering
    • /
    • v.12 no.1
    • /
    • pp.28-34
    • /
    • 2007
  • This study evaluates the performance of the packed bed scrubber and proposes the optimization of spray system for improvements of collection efficiency. The packed bed scrubber is used primarily in the semiconductor manufacturing process. The mean diameter of entering solid particles in scrubber is the submicron. The impaction between water droplets and solid particles is an important factor in removing the solid particles. Thus, the coverage area of spray system influences on the collection efficiency. The collection efficiency of a single droplet is calculated through the mathematical model and numerical calculations are performed for coverage area for each nozzle type (Droplet diameters: 500, 319.5, $289.5{\mu}m$) and injected directions (0, 15, $30^{\circ}$). In case of nozzle type 3, the collection efficiency of a single droplet is highest but the collection efficiency of spray system has lowest value because the ratio of flow rate between the gas and water is below 0.1. The results show the coverage area ratio is about 85% in the case of nozzle type 3 and downward sirection $15^{\circ}$. It was shown that a coverage area increase by two times than an existing spray system. In simulation of demister, collection efficiency by demister is predicted about 80% and the pressure drop in demister is below 3.5 Pa.

Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles (승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

Effects of the Block Arrangement on the Collection Efficiency in the Two-Stage Electrostatic Precipitator with Charging Plate (평판형 방전판을 갖는 2단식 전기집진기의 집진판 블록배열이 집진효율에 미치는 영향)

  • 박성호;박청연;김태권
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.641-652
    • /
    • 2000
  • The effect of block arrangement has been investigated on the particle deposition in the specified collecting cell of two-stage electrostatic precipitator by numerical analysis. Recirculation zone existed at the downstream of the block in the collecting cell, and the particles entering the recirculation zone were deposited on the collecting plate. Particle trajectory and deposition had considerably different phenomenon according to electrostatic and inertial effect, which depended on inlet mean velocity, electrostatic number, and particle diameter in the collecting cell. The total collection efficiency reached a minimum value through an interaction of electrostatic and inertial effect. In the computational domain, total collection efficiency for the case of two blocks in the computational domain was more than that of one block at the relative small electrostatic number. However as the block distance and inertial effect increased, the difference between the collection efficiency of two cases decreased. In the range of relatively small particle size total collection efficiency was always superior to particle collection efficiency that was predicted by Deutsch equation.

  • PDF

A Basic Study on Developing an Electrocharged Scrubber (전기하전식 세정집진장치 개발에 관한 기초 연구)

  • 김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF

A Study on the Discharge Characteristics and the Collection Efficiency of the Electrostatic Precipitator for Pulverized Coal Boiler (미분탄 연소 보일러용 전기집진기의 방전특성 및 집진특성에 관한 연구)

  • Lee, Tae-Sik;Son, Jin-Woon;Nam, Chang-Woo;Lee, Kyu-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.570-576
    • /
    • 2000
  • The discharge and the collection efficiency characteristics of an electrostatic precipitator have been studied under various operating conditions. The specific resistivity of pulverized coal dust was about 1013∼1014[${\Omega}{\cdot}cm$] and reached the maximum value of 6${\times}$1013[${\Omega}{\cdot}cm$] at 150[$^{\circ}C$]. Back corona has been occurred as dust contents and gas temperature increase. In the case of back corona occurrence, collection effciency decreased rapidly. This problem has been solved by increasing moisture contents. Experimental results showed that collection efficiency of the full wave voltage was higher than that of the pulse wave voltage. The modification parameter k of the collection efficiency equation was about 0.42.

  • PDF

Study on the Simulation for the Removal of Different Sized Particles in Suspension by Deep-Bed Filtration

  • Choo, Chang-Upp
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.18-22
    • /
    • 2005
  • A model was proposed for investigating the particle removal from suspension with particles of different sizes by deep-bed filtration, and the collection efficiency was predicted by computer simulation. Deposited particles on the pore surface may act as additional collector and reduce the pore size, which contribute to the improved collection efficiency with increase of deposition. Computer experiments for suspension of particles of three sizes and its equivalent size of mono particles were carried out and compared. The collection efficiency of suspension with poly-dispersed particles shows higher efficiency than that of suspension with mono-dispersed particles. Also the collection efficiency of smell particle of mixture is higher that that of same uniform size particles.

Collection Performance of an Electret Cabin Air Filter for Fine Particles (승용차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Gang, Seok-Hun;Kim, Dong-Cheol;Hwang, Jeong-Ho;Yun, Ung-Seop;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - I. Effect of Collection Plate Velocity - (이동 전극형 전기집진기의 집진특성에 관한 연구 - I. 집진판 이동 속도의 영향-)

  • Kim Yong-Jin;Ha Byung-Kil;Jeong Sang-Hyun;Moon Sang-Cheol;Yoo Joo-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.901-907
    • /
    • 2004
  • This study investigate the effect of collection plate velocity on the electrical and collection characteristics of a moving electrode electrostatic precipitator (MEEP). Though a high resistivity fly ash is attached at the collecting electrode, the MEEP has very stable characteristics of voltage and corona current. Collection efficiency, corona current, and overall collection efficiency are increased, as the magnitude of the collection plate velocity increases.

Effects of Electrohydrodynamic Flow and Turbulent Diffusion on Collection Efficiency of an Electrostatic Precipitator with Cavity Walls

  • Park, Seok-Joo;Park, Young-Ok;Kim, Sang-Soo;McMurry, Peter H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.97-103
    • /
    • 2001
  • The effects of the electrohydrodynamic (EHD) flow and turbulent diffusion on the collection efficiency of a model ESP composed of the plates with a cavity were studied through numerical computation. The electric field and ion space charge density were calculated by the Poisson equation of the electrical potential and the current continuity equation. The EHD flow field was solved by the continuity and momentum equations of the gas phase including the electrical body force induced by the movement of ions under the electric field. The RNG $k-{\varepsilon}$ model was used to analyze the turbulent flow. The particle concentration distribution was calculated from the convective diffusion equation of the particle phase. As the ion space charge increased, the particulate collection efficiency increased because the electrical potential increased over the entire domain in the ESP. The collection efficiency decreased and then increased, i.e. had a minimum value, as the EHD circulating flow became stronger when the electrical migration velocity of the charged particle was low. However, the collection efficiency decreased with the stronger EHD flow when the electrical migration of the particle was higher relatively. The collection efficiency of the model ESP increased as the turbulent diffusivity of the particle increased when the electrical migration velocity of the particle was low. However, the collection efficiency decreased for increasing the turbulent diffusivity when the electrical migration of the particle was higher relatively.

  • PDF

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.