• Title/Summary/Keyword: Collection 6

Search Result 2,688, Processing Time 0.032 seconds

The Study on the Optimal Operating Conditions of Direct Charging Type Electrospray for Particulate Matter Collection (미세먼지 집진을 위한 직접 하전 방식 정전분무의 최적 동작 조건에 관한 연구)

  • Sugi Choi;Sunghwan Kim;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.474-481
    • /
    • 2023
  • This paper is an experimental study on the optimal operating conditions of direct charging type electrospray for particulate matter collection. To perform the research, a direct charging type electrospray visualization system was configured to photograph the spray shape of microdroplets, and experiments were performed with varying electrode distance, flow rate, and applied voltage, which are the main factors affecting the particulate matter collection efficacy. Through image processing, the total number of microdroplets according to each condition was analyzed, and the number of microdroplets with a diameter of 1.5 mm or less was confirmed. In addition, by calculating the number of microdroplets per power consumption according to the applied voltage, the optimal operating conditions were derived in terms of energy consumption efficacy, and the microdroplet size distribution was analyzed under the optimal operating conditions. As a result of the experiment, it was confirmed that the optimal operating condition was at a flow rate of 10 mL/min and a voltage of -20 kV in case of 5 mm electrode distance, and at a flow rate of 15 mL/min and a voltage of -30 kV in case of 100 mm electrode distance.

Lazy Garbage Collection of Coordinated Checkpointing Protocol for Avoiding Sympathetic Rollback (동기적 검사점 기법에서 불필요한 복귀를 회피하기 위한 쓰레기 처리 기법)

  • Chung, Kwang-Sik;Yu, Heon-Chang;Lee, Won-Gyu;Lee, Seong-Hoon;Hwang, Chong-Sun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.29 no.6
    • /
    • pp.331-339
    • /
    • 2002
  • This paper presents a garbage collection protocol for checkpoints and message logs which are staved on the stable storage or volatile storage for fault tolerancy. The previous works of garbage collections in coordinated checkpointing protocol delete all the checkpoints except for the last checkpoints on earth processes. But implemented in top of reliable communication protocol like as TCP/IP, rollback recovery protocol based on only last checkpoints makes sympathetic rollback. We show that the old checkpoints or message logs except for the last checkpoints have to be preserved in order to replay the lost message. And we define the conditions for garbage collection of checkpoints and message logs for lost messages and present the garbage collection algorithm for checkpoints and message logs in coordinated checkpointing protocol. Since the proposed algorithm uses process information for lost message piggybacked with messages, the additional messages for garbage collection is not required The proposed garbage collection algorithm makes 'the lazy garbage collectioneffect', because relying on the piggybacked checked checkpoint information in send/receive message. But 'the lazy garbage collection effect'does not break the consistency of the whole systems.

Quality Characteristics of the White Birch Sap with Varying Collection Periods (자작나무수액의 유출시기별 품질특성)

  • Jeong, Su-Jeong;Lee, Chang-Hyeon;Kim, Hyun-Young;Lee, Sang-Hoon;Hwang, In-Guk;Shin, Chang-Seob;Lee, Jun-Soo;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.1
    • /
    • pp.143-148
    • /
    • 2012
  • This study evaluated the quality characteristics of white birch (Betula platyphylla var. japonica) sap with different collection times. The changes of browning index, turbidity, pH, total acidity, organic acid, free sugar, crude protein, crude ash, and mineral content were investigated. The browning index and turbidity increased from 0.076 to 0.222 and from 0.048 to 0.138, respectively, with increasing collection time. The pH decreased from 6.09 to 4.72, while total acidity increased with increasing collection time. Citric and malic acids were detected and malic acid increased with increasing collection time. Glucose and fructose as free sugars were detected and their contents were 0.364~0.433% and 0.497~0.664%, respectively. Crude protein and crude ash contents remarkably increased from 3.40 to 32.37 mg% and from 0.01% to 0.04%, respectively, with increasing collection time. Cu, Fe, Ca, Mg, Mn, and K were detected, and increased with increasing collection time. Particularly, K increased remarkably from 5.25 to 37.27 mg/L over time. These results indicate that the optimum processing method to improve the quality of white birch sap is necessary, because the quality of sap decreased as collection time increased, but nutritional value increased.

Factors Influencing Peripheral Blood Stem Cell Collection (자가 말초혈액 조혈모세포 채집에 영향을 주는 관련요인)

  • Choi, Yong-Suk;Kim, Kwang-Sung;Kim, Youn-Soon;Hwang, Mee-Jung;Cho, Hyung-Suk;Kim, Su-Mi
    • Asian Oncology Nursing
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Purpose: Peripheral blood stem cell transplantation (PBSCT) has been widely used. The optimal time for collection is a critical factor to obtain proper counts of CD34 cell by peripheral blood stem cell collection (PBSC). The purpose of this study was to identify the factors influencing peripheral blood stem cell collection in order to figure out the more effective timing for PBSC. Method: The subjects of this study were 189 patients undergoing 3 leukapheresis from January 28, 2005 to December 31,2006. Group's characteristics, checkup opinion of pre-peripheral blood on the day of harvest & outcome of PBSC were analyzed and evaluated using SAS statistics program after grouping patients as below; group 1-CD34 cell counts $<2{\times}10^6/kg$ (n=97); group $2-2{\times}10^6/kg$ ${\leq}CD34$ cell counts $<4{\times}10^6/kg$ (n=26); group 3-CD34 cell counts ${\geq}4{\times}10^6/kg$ (n=63). Results: Based on outcome of peripheral blood stem cell according to diagnosis, acute myelocytic leukemia (AML) was 65.5% at Group 1, Lymphoma was 21.7% at Group 2 and multiple myeloma (MM) was 70.8% at Group 3. There were significant differences in CD34 cell counts according to diagnosis (p=0.00004). Type of cytokine mobilization according to diagnosis, Lenograsim was using 62.5% of MM & 38.2% of AML and filgrastim is using 22.0% of AML only. Circular peripheral blood CD34 cell counts prior to harvest was $258.1/{\mu}L$ at Group 3 which was much higher comparing to Group 1 ($10.5/{\mu}L$) and Group 2 ($39.9/{\mu}L$) (p<0.001). TNC counts of collected peripheral blood stem cell was $15.36{\times}10^6/kg$ at Group 3 and it's much higher than Group 2 ($13.16{\times}10^6/kg$) and Group 1 ($12.36{\times}10^6/kg$) (p=0.083). There was no significant difference in MNC counts inbetween 3 groups. Conclusions: Circular peripheral blood CD34+ cell counts prior to harvest was much higher at Group 3 than Group 1 and Group 2. Therefore, the number of CD34+ cells on the day of harvest can be used as an accurate predictor for peripheral blood stem cell.

  • PDF

A Study on the Effectiveness and the Distribution of Isolated Strains by Sputum Collection Methods

  • Seong, Hee-Kyung;Lee, Jeong-Nyo
    • Biomedical Science Letters
    • /
    • v.8 no.2
    • /
    • pp.63-69
    • /
    • 2002
  • This study was performed to investigate the effectiveness of the aspiration trap method for collection of sputum by comparing with the conventional method which was collecting specimens at canular cap swab. In this study, the author tested by two methods to collect specimens from 46 patients who were cared with tracheostomy and intubation at the intensive care unit of an university hospital in Pusan, and investigated the incidence of the lower respiratory tract infection, the consistency between the two methods, the level of specimen contamination. Major results were as follows: Among the patients, 35 were cared with tracheostomy and 11 were cared with intubation. In clinical diagnosis we were classified the subjects in to two group, 17 of pneumonia group and 29 of non-pneumonia group. A total of 247 strains were isolated. Among them, most three strains were Serratia marcescens (62 strains; 25.1%), Pseudomonas aeruginosa (52 strains; 21.1%), and Acinetobacter baumannii (19 strains; 7.8%). Out of total, 188 (76.1%) strains were Gram negative bacilli. The isolated strains by the aspiration trap method were the average 2.1 strains, but by the canular cap swab method were 1.6 strains. In spite of the high contaminated possibility from the incision site and the oral cavity swab, the low isolated rates of the canular cap may be the dried environment of the canular of cap area. But the contamination rates were 57.2% of the canular cap, 51.5% of the oral swab and 50.5% of the incision site swab, respectively. The consistency of predominant microorganisms according to collection method were 86.7% of aspiration, 78.3% of canular, 74.3% of incision, and 63.6% of oral. In conclusion, the aspiration trap method fur the sputum collection from the patients with intubation of tracheostomy showed the lower contamination rate of the specimens and it was helpful for rapid, accurated interpretation of the lower respiratory tract infection and hospital infection.

  • PDF

Corona Discharge and Strong Electrolyzed Water Generation Characteristics of the Electrode System Bedded by Dielectric Pellets (유전체구 충진형 전극계의 코로나방전과 강전해수 발생특성)

  • 김진규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.46-54
    • /
    • 2002
  • A dielectric pellets bedded parallel plates with a membrane centered have been proposed as an ion separation and collection system in water. and effects of the relative dielectric constant and the applied square wave pulse voltage on the characteristics of ion separation and collection in tap water and NaCl dissolved tap water have been investigated. As a result, electrolyzed water of pH 3.1 and 10.6 were obtained with only tap water at the pulse current of 1.0[A] and flow rate of 0.5[LPM]. And the higher ionized water of pH 2.8 and pH 11.7 ware obtained in 0.1[%wt] NaCl dissolved water. When the dielectric pellets of BaTiO$_3$ having the highest dielectric constant were bedded in the ion separation and collection cell, the ionized water of pH 2.7 and pH 11.7 were obtained with only tap water. And the ionized water of pH 2.4 and pH 12.0 were obtained in 0.1[wt%] NaCl dissolved tap water with the dielectrics pellets bedded ones.

Real-Time Traffic Information Collection Using Multiple Virtual Detection Lines (다중 가상 검지선을 이용한 실시간 교통정보 수집)

  • Kim, Eui-Chul;Kim, Soo-Hyung;Lee, Guee-Sang;Yang, Hyung-Jeong
    • The KIPS Transactions:PartB
    • /
    • v.15B no.6
    • /
    • pp.543-552
    • /
    • 2008
  • ATIS(Advanced Traveler Information System) is the system to offer a real-time traffic information or traffic situation for the benefit of the client. One of traffic information collection methods for ATIS research is the method of image analysis. The method is divided into two : one is the method to set two loop detectors at the area and the other is the method detecting the vehicle through an image analysis. In this paper, we propose a real-time traffic information collection system to mix two methods. The system installs multiple virtual detection lines and traces the location of the vehicle. Use of multiple virtual detection lines supplements the defect of the method of loop detectors. And we drew a representative pixels in the detecting area and used it for image analysis. This is to solve the problem of time delay which increases as the image size increases. We gathered traffic images and experimented using the system and got 92.32% of detection accuracy.

Automatic Patch Information Collection System Using Web Crawler (웹 크롤러를 이용한 자동 패치 정보 수집 시스템)

  • Kim, Yonggun;Na, Sarang;Kim, Hwankuk;Won, Yoojae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.6
    • /
    • pp.1393-1399
    • /
    • 2018
  • Companies that use a variety of software use patch management systems provided by security vendor to manage security vulnerabilities of software to improve security. System administrators monitor the vendor sites that provide new patch information to maintain the latest software versions, but it takes a lot of cost and monitoring time to find and collect patch information because the patch cycle is irregular and the structure of web page is different. In order to reduce this, studies to automate patch information collection based on keyword or web service have been conducted, but since the structure to provide patch information in vendor site is not standardized, it was applicable only to specific vendor site. In this paper, we propose a system that automates the collection of patch information by analyzing the structure and characteristics of the vendor site providing patch information and using web crawler to reduce the cost and monitoring time consumed in collecting patch information.

Comparison and Evaluation of Data Collection System Database for Edge-Based Lightweight Platform (엣지 기반 경량화 플랫폼을 위한 데이터 수집 시스템의 데이터베이스 비교 및 평가)

  • Woojin Cho;Chae-young Lim;Jae-hoi Gu
    • Journal of Platform Technology
    • /
    • v.11 no.5
    • /
    • pp.49-58
    • /
    • 2023
  • Factory energy management system is rapidly growing and evolving due to factors such as the 3rd Basic Energy Plan and global energy cost increases, as well as environmental issues. However, implementing an essential data collection system for energy management in factory settings, which have limited space and unique characteristics, presents spatial, environmental, and energy-related challenges. This paper endeavors to mitigate these challenges by devising a data collection system implemented through an edge-based lightweight platform. A comparison and evaluation of database operation on edge devices are conducted. To conduct the evaluation, a benchmarking tool called CDI Benchmark is developed, utilizing the characteristics of existing factories involved in practical applications. The evaluation results revealed that RDBMS systems like MySQL encountered errors in the database due to high data insertion loads, making them inoperable. On the other hand, InfluxDB, thanks to its highly efficient compression algorithm, demonstrated compression rates about 6 times higher than MyRocks according to the evaluation. However, it was observed that MyRocks outperformed InfluxDB by a significant margin, recording a maximum processing time approximately 80 times faster compared to InfluxDB.

  • PDF

Effects of Dummy Cow or Teaser Bull for Semen Collection on Semen Characteristics in Hanwoo Proven Bull (한우 종모우에 있어 정액 채취시 의빈대 혹은 의빈우 이용이 정액성상에 미치는 영향)

  • Lee S.S.;Jeong J.;Park N.H.
    • Journal of Embryo Transfer
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 2006
  • Thirty heads of proven bulls were used to identify the effects of mounting conditions (dummy cow vs. teaser bull) on semen characteristics in Hanwoo. Semen was collected from bulls daily two times with 1 h interval every $3{\sim}6$ days for 6 months. Bulls mounted dummy cow (BDC) had higher both the $1^{st}$ and the $2^{nd}$ sperm concentrations than in bulls mounted teaser bull (BTB), resulting in more total sperm number (p<0.05). The total sperm number in the $1^{st}$ collection was the highest in BDC with collection interval of 5 days. Total sperm number in the $1^{st}\;and\;2^{nd}$ collections tended to be more in the BDC of $4{\sim}5$ years old and BTB of $6{\sim}7$ years old. These results indicate that semen collection using dummy cow has a better effect than teaser bull on semen characteristics.