• 제목/요약/키워드: Collapse Strength

검색결과 456건 처리시간 0.022초

Structural identification and seismic performance of brick chimneys, Tokoname, Japan

  • Aoki, T.;Sabia, D.
    • Structural Engineering and Mechanics
    • /
    • 제21권5호
    • /
    • pp.553-570
    • /
    • 2005
  • Dynamic and static analyses of existing structures are very important to obtain reliable information relating to actual structural properties. For this purpose a series of material test, dynamic test and static collapse test of the existing two brick chimneys, in Tokoname, are carried out. From the material tests, Young's modulus and compressive strength of the brick used for these chimneys are estimated to be 3200 MPa and 7.5 MPa, respectively. The results of static collapse test of the existing two brick chimneys are discussed in this paper and composed with the results from FEA (Finite Element analysis). From the results of dynamic tests, the fundamental frequencies of Howa and Iwata brick chimneys are estimated to be about 2.69 Hz and 2.93 Hz, respectively. Their natural modes are identified by ARMAV (Autoregressive Moving Average Vectors) model. On the basis of the static and dynamic experimental tests, a numerical model has been prepared. According to the European code (Eurocode n. 8: "Design of structures for earthquake resistance") non-linear static (Pushover) analysis of the two chimneys is carried out and they seem to be vulnerable to earthquakes with 0.25 to 0.35 g.

Capacity design of boundary elements of beam-connected buckling restrained steel plate shear wall

  • Liu, Wen-Yang;Li, Guo-Qiang;Jiang, Jian
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.231-242
    • /
    • 2018
  • As a lateral load resisting component, buckling restrained steel plate shear walls (BRW) have excellent energy dissipating capacity. Similar to thin steel plate shear walls, the mechanical behavior of BRWs depends on the boundary elements (adjacent beams and columns) which need adequate strength and stiffness to ensure the complete yielding of BRWs and the emergence of expected plastic collapse mechanism of frame. This paper presents a theoretical approach to estimate the design forces for boundary elements of beam-connected BRW (i.e., The BRW is only connected to beams at its top and bottom, without connections to columns) using a fundamental plastic collapse mechanism of frame, a force transferring model of beam-connected BRW and linear beam and column analysis. Furthermore, the design method of boundary beams and columns is presented. The proposed approach does not involve nonlinear analyses, which can be easily and efficiently used to estimate the design forces of beams and columns in a frame with BRWs. The predicted design forces of boundary elements are compared with those from nonlinear finite element analyses, and a good agreement is achieved.

Seismic performance assessment of the precast concrete buildings using FEMA P-695 methodology

  • Adibi, Mahdi;Talebkhah, Roozbeh
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.55-67
    • /
    • 2022
  • The precast reinforced concrete frame system is a method for industrialization of construction. However, the seismic performance factor of this structural system is not explicitly clarified in some existing building codes. In this paper, the seismic performance factor for the existing precast concrete building frame systems with cast-in-situ reinforced shear walls were evaluated. Nonlinear behavior of the precast beam-column joints and cast-in-situ reinforced shear walls were considered in the modeling of the structures. The ATC-19's coefficient method was used for calculating the seismic performance factor and the FEMA P-695's approach was adopted for evaluating the accuracy of the computed seismic performance factor. The results showed that the over-strength factor varies from 2 to 2.63 and the seismic performance factor (R factor) varies from 5.1 to 8.95 concerning the height of the structure. Also, it was proved that all of the examined buildings have adequate safety against the collapse at the MCE level of earthquake, so the validity of R factors was confirmed. The obtained incremental dynamic analysis (IDA) results indicated that the minimum adjusted collapse margin ratio (ACMR) of the precast buildings representing the seismic vulnerability of the structures approximately equaled to 2.7, and pass the requirements of FEMA P-695.

암석과 토층 경계면의 전단강도 특성연구 (A Study on Characteristics of Shear Strength in Rock-soil Contacts)

  • 이수곤
    • 한국환경복원기술학회지
    • /
    • 제4권3호
    • /
    • pp.49-54
    • /
    • 2001
  • It is common that the soil layer is a few meters below the earth's surface and the rock mass is below the soil layer in the view of geological characteristics in Korea. And the boundary between rock and soil is clearly divided. When dealing with the stability of rock masses, as in the case of rock slopes or dam foundations, the majority of the collapses is not within the soil layer, but within the soil-rock boundary. Therefore it is important to identify the shear strength characteristics between soil-rock boundary. And then in the method of reinforcement on landslide this chose a cut slope near Daemo elementary school in Seoul, surveyed shear strength between soil-rock contacts and considered a large scale collapse using a limit equilibrium method.

  • PDF

파이프골조 온실의 조립연결구 내력에 관한 실험적 연구 (Experimental Analysis on Yield Strength of Pipe Connectors and Joints for Pipe Framed Greenhouses)

  • 남상운;김문기;권혁진
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.271-274
    • /
    • 2001
  • Experiments on the yield strength of pipe connectors made of metal wire, joint pins, pole pipes, multi span insertion joints, and T-clamp joints used in pipe houses were conducted. The strength of connections of a pipe connector made of metal wire was adequate but it had a big difference according to loading direction. The collapse load of pipes connected with a joint pin was lower than that of single pipes. Also experimental results showed that pole pipes for use in a part of frame buried under the ground were safe, and the strength of multi span insertion joints should be increased. The resistant moment of T-clamp was about 13.7% of a single pipe.

  • PDF

폴리머 시멘트 모르터용 골재로서 금속광산 폐광미의 활용연구 (A study on utilizatio of metal-mine tailings for polymer cement mortars)

  • 민경원
    • 자원환경지질
    • /
    • 제32권1호
    • /
    • pp.13-18
    • /
    • 1999
  • The tailings stocked at two tailing piles in Sangdong aea have raised collapse hazards and various environmental problems. A trial for effective utilization of tailings as fine aggregates for polymer concrete has been performed along with mineralogical and physical characterization of tailings. The tailings from the Sangdong mine, mainly composed of quartz, orthoclase, amphiboles and muscovite, are alkaline and tailings at the new tailing pile are generally finer in grain size than those at the old tailing pile. In case of using New Tailings as fine aggregates, cement mortar with equivalent amounts of tailings and sands shows the highest compressive strength. Cement mortars containing tailings show lower values of compressive strength, splitting tensile strength and flexural strength than those not-containing tailings. Mixture of polymers such as SBR and EVA in cement mortars raises strengths of cement mortars effectively, which shows potential possiblity to utilize the tailings in Sangdong area as fine aggregates for polymer concretes.

  • PDF

The distribution of magnetic field strength in Orion A region

  • Hwang, Jihye;Kim, Jongsoo
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.43.3-43.3
    • /
    • 2019
  • Magnetic fields play an important role in supporting molecular clouds against gravitational collapse. The measured magnetic field strengths in molecular clods enable us to see the effect of magnetic fields in star-forming regions. People have used the Chandrasekhar and Fermi (CF) method to estimate magnetic field strength from observational quantities of molecular cloud density, turbulent velocity and polarization angle dispersion. However, previous studies obtained just one magnetic field strength over the quite large region of a molecular cloud by using the CF method. We here suggest a way to estimate magnetic field strength distribution in Orion A region. We used 450 and 850-micron polarization data of James Clerk Maxwell Telescope (JCMT). Magnetic field strengths were estimated in two wavelengths with 4 pixel resolutions of 16, 20, 24 and 28". Through statistical analysis, we proved the difference of magnetic field strengths between two wavelengths were caused by the difference of their beam sizes. Additionally, we calculated the radii of curvature of polarization segments to select a best pixel resolution for estimating the magnetic field distribution. The pixel resolution should be larger than a radius of curvature. We selected that 20 or 24" pixel resolutions are good choices towards Orion A region.

  • PDF

정적 및 동적 해석을 통한 철근콘크리트 무량판 구조의 연쇄 붕괴 저항 성능 평가 (Evaluation for Progressive Collapse Resistance of a RC Flat Plate System Using the Static and Dynamic Analysis)

  • 이선웅;신성우
    • 콘크리트학회논문집
    • /
    • 제23권2호
    • /
    • pp.245-252
    • /
    • 2011
  • 현재 한국에서는 연쇄 붕괴에 대한 설계지침이 적용되고 있지 않으며, 특히 무량판 구조의 연쇄 붕괴 저항 성능에 대한 연구는 초기단계라고 할 수 있다. 따라서 이 연구에서는 철근콘크리트 무량판 구조의 연쇄 붕괴 저항 성능을 평가하기위하여 3가지 해석법을 수행하였다. 선형 정적 해석을 통하여 GSA의 대체경로법에 의한 DCR 값의 차이를 비교하였고, 선형 동적 해석을 통하여 기둥 제거 이후의 수직 변위를 비교하였으며, 비선형 정적 해석을 통하여 최대 하중 계수를 판단하였다. 유효 보폭 모델과 판 유한 요소 해석 모델의 차이점을 분석하기 위하여 여러 변수들에 따라 유한 요소 해석이 수행되었다. 무량판 구조에서 실무에서 많이 사용되고 있는 유효 보폭으로 모델링하는 방법은 슬래브의 강성 기여도를 반영하고 있지 못해 연쇄 붕괴 성능 평가는 상세 유한 요소 해석이 적절할 것으로 판단된다. 여러 변수들을 종합 모서리 기둥(CC)을 제거할 경우가 가장 불리한 조건이고, 내부 기둥(IC)이 제거될 경우가 가장 유리한 조건으로 나타났다. 이 연구에서 제시된 무량판 구조의 연쇄 붕괴 저항 성능 결과로부터 향후 무량판 구조의 성능을 합리적으로 평가하는데 유용하게 활용될 수 있을 것으로 사료된다.

알루미늄-복합재료 혼성 사각관 보의 굽힘 성능평가 (Bending Performance Evaluation of Aluminum-Composite Hybrid Square Tube Beams)

  • 이성혁;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.76-79
    • /
    • 2005
  • Bending deformation and energy absorption characteristics of aluminum-composite hybrid tube beams have been analyzed for improvement in the bending performance of aluminum space frame by using experimental tests combined with theoretical and finite element analyses. Hybrid tube beams composed of glass fabric/epoxy layer wrapped around on aluminum tube were made in autoclave with the recommended curing cycle. Basic properties of aluminum material used for initial input data of the finite element simulation and theoretical analysis were obtained from the true stress-true strain curve of specimen which had bean extracted from the Al tube beam. A modified theoretical model was developed to predict the resistance to the collapse of hybrid tube beams subjected to a bending load. Theoretical moment-rotation angle curves of hybrid tube beams were in good agreement with experimental ones, which was comparable to the results obtained from finite element simulation. Hybrid tube beams strengthened by composite layer on the whole web and flange showed an excellent bending strength and energy absorption capability.

  • PDF

경량화용 혼성 알루미늄 CFRP 사각튜브의 축 압궤특성 (Axial Collapse Characteristics of Combined Aluminum CFRP Square Tubes for Light-Weight)

  • 이길성;차천석;정진오;양인영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2004
  • Aluminum and CFRP tube is light-weight material representatively but collapse mechanism is different under axial loading. Aluminum tube absorbs energy by stable plastic deformation under axialloading. While CFRP(Carbon Fiber Reinforced Plastics)tube absorb synergy by unstable brittle failure but its specific strength and stiffness is higher than that of aluminum tube. In this study, for complement of detect and synergy effect by combination with the advantages of each member, the axialcollapsetests were performed for combined aluminum CFRP tubes which are composed of aluminum tubes wrapped with CFRP out side aluminum square tubes. Collapsecharacteristics were analyzed for combined square tubes which have different CFRP orientation angle and thickness. Test results were compared with that of aluminum tubes and CFRP tubes.

  • PDF