• Title/Summary/Keyword: Coliform

Search Result 902, Processing Time 0.031 seconds

Distribution of Marine Bacteria and Coliform Groups in Puksin Bay, Korea (북신만의 대장균군 및 해양세균의 분포)

  • CHOI Jong-Duck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.202-208
    • /
    • 1995
  • Puksin Bay located in the northwestern pan of Tongyeong, Korea has been contaminated by municipal wastewaters. In Puksin Bay, red tides have occured almost every year since the early 1980's. This experiment was carried out two times in a month in the winter in 1990, the summer' 1991, and the winter in 1994 so as to clarify the distribution marine bacteria and coliform groups in Puksin Bay. The water quality of Puksin Bay was not only move polluted than that of any other costal area around Tongyeong, but also its water quality was investigated to keep going bad. Viable cell counts in Puksin Bay were $4.9\times10^3/ml$ in 1990's winter, $3.6\times10^6/ml$ in 1991's summer, and $2.1\times10^4/ml$ in 1994's winter. The variation of seasonal total and fecal coliform MPN/100ml in Puksin Bay were $6.7\times10^2\;and\;2.6\times10^2$ in 1990's winter, $1.5\times10^4$ and $5.4\times10^3$ in 1991's summer, and $1.5\times10^3$ and $5.6\times10^2$ in 1994's winter, respectively. The changes of stational total coliform MPN/100m1 from station 1 to station 8 in Puksin Bay were 95,000, 1600, 1,000, 182, 151, 94, 43 and 13 in winter, and 110,000, 29,000, 2,400, 4,100, 1,700, 1,700, 810 and 150 in 1991's summer, and 3,381, 1928, 1582, 256, 161, 59 and 23 in 1994's winter. During the study period, the number of viable cell was ranged from $10^4\;to\;10^7/ml$ and 307 bacteria strains were isolated from Puksin Bay. The dominant species were Acinetobacter spp. 86 $(28.3\%)$, Pseudomonas spp. 51 $(16.6\%)$, Flavobacterium spp. 41 $(13.4\%)$, Escherichia coli 36 $(11.7\%)$, and Vibrio spp. 27$(8.8\%)$. The results obtained in this study indicate that this bay is getting to contaminate far more with municipal wastewaters and cultivation of the shellfish and finfish in this bay is not proper. When municiple wastewaters keep flowing into this bay, any other coastal area around Tongyeong may be contaminated.

  • PDF

Water Quality Variations due to Tidal Change in the Lower Part of the Nagdong River (조석에 따른 낙동강 하류수질의 변화)

  • KIM Yong-Gwan;CHANG Dong-Suck;MOON Hong-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.109-118
    • /
    • 1985
  • This experiment was carried out to evaluate the water quality in the lower part of the Nagdong river in Korea. Three hundred and sixty water samples were collected from the 15 stations from December 1981 to November 1982 by tide(see Fig.1). Water temperature, pH, chloride ion, salinity, total coliform, fecal coliform, viable cell count and the composition of coliform were observed to evaluate the water quality. The variations of water temperature was ranged from $2.0^{\circ}C\;to\;29.5^{\circ}C$ and as mean value from $15.8^{\circ}C\;to\;18.9^{\circ}C$. The range of pH was 6.00-8.88 and 7.20-7.96 as mean value. The concentration of chloride ion from St. 1 to 5 was higher as 17.51-771 mg/l in flood tide than 13.12-264.58 mg/l in ebb tide. Specially, water quality at St.1 (Samrangjin) which located about 46 km far from Hadan was also influenced by tide. Salinities of water in flood tide were a litte higher ($11.05{\sim}31.08\%0$) than those of in ebb tide ($7.80{\sim}29.28\%0$). Total coliform MPN's ranged from 3.6/100 m/l to 460,000/100ml. The geometric mean value of the upper area (included St. $1{\sim}3$) was $259{\sim}538/100ml$, that of the middle area (included St. $4{\sim}6$) was $1,097{\sim}39,544/100ml$ for it leveled heavy contamination. Specially, in the ebb tide St. 10 was influenced by St. 6 and 7. In the upper area, the geometric mean value of fecal coliform MPN's was $109{\sim}199/100ml$ but in the area in cluded St. 5, 6 and 7 were heavily contaminated by domestic sewage, waste water from the factories area and bird's excrement. Composition of coliform was $17\%$ Escherichia coli group, $33\%$ Citrobacter freundii group, $28\%$ Enterobacter aerogenes group and $21\%$ others. Plate count of samples was varied from <30 to $3.9{\times}10^4/ml$ during the study period.

  • PDF

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF

Bacteriological and Physiochemical Water Quality of Seawater in Tongyeong Harbor, Korea (통영항 해수의 세균학적 및 이화학적 수질)

  • CHOI Jong-Duck;JEOWG Woo-Geon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.611-616
    • /
    • 2001
  • The bacteriological and physiochemical analysis of seawater in Tongyeong harbor was conducted to evaluate sanitary conditions, The samples were collected at 6 stations established once a month from January to December, 2000. During the study period, the ranges of temperature, transparency, chemical oxygen demand, dissolved oxygen, dissolved nitrogen, phosphate and chlorophyll-a were $6.8\sim25.2^{\circ}C,\;1.0\sim2.5\;m,\;1.79\sim2.41\;mg/L,\;5.7\sim10.1\;mg/L,\;6.59\sim10.53{\mu}g-at/L,\;0.56\sim1.01{\mu}g-at/L\;and\;1.21\sim9.54\;mg/m^3$, respectively, The viable cell counts of seawater in Tongyeong harbor ranged from $3.0\times10^4CFU/mL\;to\;6.9\times10^6CFU/mL$. The coliform group and fecal coliform MPN's of the samples were ranged $23\~4,600\;MPN/100\;mL$ (means 540 MPN/100 mL) and $11\~1,600\;MPN/100\;mL$ (means 210 MPN/100 mL), respectively, The coliform group was classified with IMViC reactions and pathogenic vibrios were analyzed. Two hundred eighteen strains that were obtained from seawater samples in Tongyeong harbor represented Escherichia coli group, $66.1\%$; Citrobacter freundii group, $11.0\%$; Enterobacter aerogenes, $9.6\%$; and unknown, $13.3\%$, respectively. During the study period, infectious bacteria such as Vibrio cholerae O1, Salmonella sp. and Shigella sp. were not detected from the samples, but detection ratios of V. parahaemolyticus, V cholerae non-O1 and V. vulnificus were $10.0\sim30.1\%$.

  • PDF

Bacteriological and Physicochemical Character of Sea Water and Sediments in South Western Part of Jinhae Bay, Korea (진해만 남서부 해역의 해수와 저질의 세균학적 및 이화학적 특징)

  • Choi Jong Duck;Kim Jeong Gyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.6
    • /
    • pp.621-626
    • /
    • 2002
  • The bacteriological and physicochemical analysis of sea water and sediments in south western part of Jinhae Bay was conducted. The samples were collected from 40 stations, which were established once a month from January to December, 2000. During the study period, the range of temperature was from 5.5 to $23.7^{\circ}C$, the concentration of chemical oxygen demand ranged from 1.20 to 1.55 mg/L, dissolved oxygen ranged from 3.7 to 9.1 mg/L, dissolved inorganic nitrogen ranged from 2.79 to 7.09 $\mu$g-at/L phosphate phosphorus ranged from 0.39 to 0.57 $\mu$g-at/L, and chlorophyll-$\alpha$g-at/L ranged from 4.28 to $9.66 mg/m^{3}$. The chemical oxygen demand, acid volatile sulfide and ignition loss of sediments in south western part of Jinhae Bay ranged from 0.04 to 0.40, from 24.23 to 35.52 mg/L and from 10.49 to $11.09\%$ respectively. The coliform group and fecal coliform MPN's of sea water in south western part of Jinhae Bay ranged from <3.0 to 1,600 MPN/1003nL (means <3.0 MPN/100 mL) and from <3.0 to 93 MPN/100 mL (means <3.0 MPN/ 100 mL), respectively. The coliform group was classified with IMViC reactions were analyzed. Two hundred eighteen strains that were obtained from sea water samples in south westen of Jinhae Bay represented Escherichia coli group, $61.9\%$; Citrobacter freundii group, $12.1\%$; Enterobacter aerogenes, $14.1\%$; and unknown, $11.9\%$.

Development of River Recreation Index Model by Synthesis of Water Quality Parameters (수질인자의 합성에 의한 하천 레크리에이션 지수 모델의 개발)

  • Seo, Il Won;Choi, Soo Yeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1395-1408
    • /
    • 2014
  • In this research, a River Recreation Index Model (RRIM) was developed to provide sufficient information on the water quality of rivers to the public in order to secure safety of publics. River Recreation Index (RRI) is an integrated water quality information for recreation activities in rivers and expressed as the point from 0 to 100. The proposed RRIM consisted of two sub models: Fecal Coliform Model (FCM) and Water Quality Index Model (WQIM). FCM predicted Fecal Coliform Grade (FCG) using a logistic regression and WQIM synthesized water quality parameters of, DO, pH, turbidity and chlorophyll a into Water Quality Index (WQI). FCG and WQI were integrated into RRI by the integrating algorithm. The proposed model was applied to upstream of Gangjeong Weir in Nakdong River, and compared with Real Time Water Quality Index (RTWQI) which is the existing water quality information system for recreation use. The results show that calculated RRI reflected change of integrated water quality parameters well. Especially chlorophyll a showed Pearson correlation coefficient -0.85 with RRI. Also, RRIM produced more conservative index than RTWQI because RRI was calculated considering uncertainty of water quality criteria. Further, RRI showed especially low values when fecal coliform was predicted as low grade.

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

Effects of Fermentation to Improve Hygienic Quality of Powdered Raw Grains and Vegetables Raw Grains and Vegetables Using Lactobacillus sp. Isolated from Kimchi (김치분리균주 Lactobacillus sp.를 Starter로 한 발효생식 제조에서의 위생미생물 살균효과)

  • 김동호;송현파;변명우;차보숙;신명곤
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.5
    • /
    • pp.765-769
    • /
    • 2002
  • Improvement of hygienic quality of powdered raw grains and vegetables by fermentation was investigated. Luc-tobacillus sp. isolated from kimchi was used as a starter. The cell counts of coliform group and SS enteric bacteria on the SS agar plate in raw grains and vegetables were 2.3$\times$103 cfu/mL and 8.6$\times$10$^3$ cfu/mL, respectively. The starlet, Lactobacillu sp., reached 10$^{7}$ cfu/mL after 48 hr in fermentation. At that time, the coliform group and enteric bacteria on the SS agar plate were gradually inactivated and eliminated after 60 hr of fermentation. During the fermentation process, pH of the suspension was lowered and acidity increased. Antimicrobial activity of the acidic supernatant of fermented raw grains and vegetal]les against the E. coli sp. and Salmonella sp. was higher than that of lactic acid solution or neutralized supernatant. Therefore, it was considered that antimicrobial effect of the fermented raw grains and vegetal]les might be accelerated by tile synergic effect of acid and bacteriocin, and liquid fermentation of powdered raw grains and vegetables will be effective for inactivation of hygienic microorganisms.

Study on the Sanitary Indicative Bacteria of Sea Water in Fish Preservatory Tanks during the Mid Summer (여름철 활어조해수(活魚槽海水)의 세균학적(細菌學的)인 연구(硏究))

  • Heo, Seong Ho;Kim, Young Man;Lee, Dong Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 1983
  • The purpose of the present study is to obtain some fundamental data for hygienic control of sanitary indicative bacteria of sea water in fish preservatory tanks at popular swimming beaches in Busan including Songdo, Kwanganri, Haeundae and Songjeong from July to August in 1982. The geometric mean values of coliform group and fecal coliform MPN (most probable number) of sea water of Kwanganri were 27,300/100ml and 8,700/100ml respectively, which showed the highest population of the study regions. MPN's of the sea water of beaches and fish preservatory tanks showed 21,000/100ml and 8,800/100ml respectively at Kwanganri, which were also the highest numbers. The degree of the hygienic bacteriological populations of both the seawater and that of the fish tanks at a same region showed similar trend. The pollution caused by coliform group generally increased as viable cell counts increased. The types of coliform organisms isolated from seawater in fish presorvatory tanks by IMViC reaction were 42% Escherichia coli group, 2% Citrobacter freundii group, 44% Klebsiella aerogenes group and 12% others.

  • PDF

Evaluation of the $HApS^{TM}$ Method for the Enumeration of Aerobic Microorganisms and Coliforms in Retailed Meat Samples in Korea

  • Keun-Seok Seo;Wonki Bae;So-Hyun Kim;Nam-Hoon Kwon;Ji-Yeun Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.194-199
    • /
    • 2001
  • This study was designed to compare the effectiveness and applicability of the HApS$^{TM}$ (Hazard Analysis process System; HUKO, Seoul, Korea) based on Petrifilm$^{TM}$ (3M, St. Paul, MN, USA) with the AOAC (the Association of Official Analytical Chemists) standard total aerobic count (TAC) method and coliform count (CC) method for meat products. The comparisons were carried out using 230 meat samples collected from various retailers: 80 pork samples, 80 chicken samples, and 70 beef samples. In the comparison of the correlation coefficient (r) between conventional method and HApS$^{TM}$ method by a linear regression analysis, the correlation coefficients in total microorganism were 0.97767, 0.90712, and 0.95594 in pork, beef, and chicken samples, respectively. The correlation coefficients in coliform count were 0.82062, 0.94833, and 0.96839 in pork, beef and chicken samples, respectively. All the independent t-test on measurement values between conventional method and HApS$^{TM}$ method represented no significant differences in the means between two methods at the 0.05 of significance level($\alpha$=0.05). Based on the high correlation between HApS$^{TM}$ and the AOAC standard methods in the TAC and CC, it might be compatible to employ the HApS$^{TM}$ method to measure the microbial contamination in livestock products. HApS$^{TM}$ method was simpler and less time-consuming in sample preparation and procedures faster than the conventional method. These results suggested that the HApS$^{TM}$ method could be substitute for the conventional methods in the analysis of microbial contamination measurement in meat products.n meat products.

  • PDF