• Title/Summary/Keyword: Cold test

Search Result 1,537, Processing Time 0.025 seconds

A clinical study on patients with Cold Hypersensitivity on hands and feet and their autonomic nervous system function using of Heart Rate Variability(HRV) (수족냉증 환자의 실태 및 HRV(Heart Rate Variability)를 이용한 자율신경계 기능 평가 연구)

  • Kim, Eun-Sook;Hwang, Jae-Ho;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Choi, Jae-Ho
    • Journal of Oriental Medical Thermology
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Objectives : This study was designed to analyze basic data for cold hypersensitivity patients with a questionnaire and investigate correlation between cold hypersensitivity and Heart Rate Variability(HRV). Methods : 49 patients who complain of cold hypersensitivity on hands and feet in ambulatory care were investigated in Oriental Gynecology, Kyunghee Oriental Medical Center and Women medical center, Kangnam Koreana hospital from May 1, 2006 to October 20, 2006. All patients were asked to answer a questionnaire. After careful I examination to rule out other disease which may affect Digital Infrared Thermal Imaging(DITI) and HRV data, patients were taken thermography for the diagnosis of cold hypersensitivity Based on the result of thermography, the patients were divided into two groups(Objective cold hypersensitivity and Subjective cold hypersensitivity). Then, these two groups were compared using HRV data which was measured in the supine position for 5 minutes. Results: 1. For most patients, cold hypersensitivity first developed during puberty. 2. The parts of the body that felt cold first time were hands and feet. 3. The cold sensation was increased in winter or at bedtime Showing that the sensation can be changed according to the level of coldness. 4. Among women who sufferfrom cold hypersensitivity, very few of them were treated. 5. More than half of cold hypersensitivity patients's family member also had a cold hypersensitivity. 6. The decrease in mean values of LF/HF ratio was observed in objective cold hypersensitivity group than subjective cold hypersensitivity group and the decrease was significant(P=0.014) when examined by Student t-test. Conclusions : It is necessary that the cold hypersensitivity patients should be treated carefully considering the facts mentioned above. And it can be suggested that dysautinomia be related with cold hypersensitivity and be evaluated by HRV.

  • PDF

A Study on the Effect of Cold Application Using a Sponge Bath in Healthy Adults (냉요법 적용방법에 따른 냉요법 효과에 관한 연구-건강한 성인 여성에서 스폰지 목욕방법을 중심으로)

  • Chung, Hyun-Sook;Kang, Kyu-Sook;Hwang, Ae-Ran
    • The Korean Nurse
    • /
    • v.28 no.3
    • /
    • pp.68-82
    • /
    • 1989
  • This study was a quasi-experimental research study to test the characteristics of temperature regulation according to sponge bath methods of cold application. Thirteen volunteers were selected from among nursing college students according to an established criteria using a purposive sampling technique. Four different cold application methods were used: $\circled1$ tepid water sponge bath at $28^{\circ}C$, $\circled2$ 20% alcohol sponge bath at $28^{\circ}C$, $\circled3$ 40% alcohol sponge bath at $28^{\circ}C$ and $\circled4$ tepid water sponge bath at 28$^{\circ}$C plus an ice bag to the head. Changes in rectal temperature, mean skin temperature, mean body temperature, heat content change and thermal discomfort during the cold application were measured at 5 minute intervals over a 120 minute period. The data collection period was from Dec. 20, 1988 to Feb. 3, 1989. The data were analyzed using descriptive statistics, simple regression, ANOVA, Duncan's multiple range test and Pearson correlation coefficient using the SPSS-X Program. The results of the study are summarized as follows. Five general hypothesis were tested. Hypothesis 1 that "Change in heat content will be decreased for each cold application method according to the cold application time" was rejected. (tepid water sponge bath: after 10 minutes of cold application, 20% alcohol sponge bath: after 25 minutes of cold application: 40% alcohol sponge bath: after 45 minutes of cold application, tepid water sponge bath plus an ice bag to the head: after 80 minutes of cold application) Hypothesis 2 that "Thermal discomfort will be changed for each cold application method according to the cold application time" was rejected after 5minutes of cold application. Hypothesis 3 that "Change in heat content will differ among the cold application methods" was accepted except 0~5, 0~10, 0~65, 0~105 and 0~120 minute. This difference showed significance only between sponge bath methods and tepid water sponge bath plus an ice bag to the head. Hypothesis 4 that "Thermal discomfort will differ among the cold application methods" was accepted at 15, 20, 35, 45, 75, 80, 90, 95, 100, 105, 110, 115 and 120 minute of cold application time. This difference showed significance only between sponge bath methods and tepid water sponge bath plus an ice bag to the head. Hypothesis 5 that "The higher the change in heat content, the higher the thermal discomfort during the cold application time" was accepted for between 10~60 and 75 minute of cold application. In conclusion, this study showed that in sponge bath at $28^{\circ}C$, 10~80 minute was a effective cold application time in the view of heat loss through the skin. Concerning the effects of evaporation and thermal discomfort, it was found that there was no difference with regard to the solutions; tepid water sponge bath; 20% alcohol sponge bath or 40% alcohol sponge bath at a $28^{\circ}C$ controlled solution temperature. So it was thought that the type of solution itself did not have a big influence on the heat loss through skin. The combined effect of sponge bath with an ice bag to the head showed a significant difference and also showed a slight increase in thermal discomfort. On the basis of this research it can be concluded that cold application, for example, an ice bag to the head during a tepid water sponge bath is a good method as it increase heat loss through conduction, although fit can also cause a slight increase in thermal discomfort. The correlation between changes in heat content and thermal discomfort were not high. So factors other than change in heat content are considered to have an effect on the cognition of thermal discomfort.

  • PDF

Identification of the genes which related cold (low temperature) stress in Bombyx mori

  • Kang, Min-Uk;Choi, Kwang-Ho;Park, Kwan-Ho;Nho, Si-Kab
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.33 no.2
    • /
    • pp.102-107
    • /
    • 2016
  • Stress may be defined as any modification of environmental parameters that leads to a response by biological organisms. Stresses that affect biolpgical structures may be nonthermal, such as ultraviolet radiation, pH, or salinity, or thermal. Temperture is one of the major stresses that all living organism face. The major effects of cold(low emperature) are decrease of membrane fluidity and the stabilization of secondary structures of RNA and DNA in the cells, which may effect the efficiency of translation, transcription, and DNA replication. In this study, we focus on discovering the genes that are expressed by the cold(low temperature) stress in the silkworm. In cold(low temperature) stress test, we found 100% survive from cold stress at $0^{\circ}C$ up to 12h and $-5^{\circ}C$ up to 2h, and then, survive rate was rapidly decrease in silkworm. Thereafter two whole genes have selected by SSH(Suppression subtractive hybridization). (GenBank accession : GQ149511, GQ338156)

Development of Low Pollution Grinding Technology using Mist (Mist를 이용한 저공해 연삭 가공기술 개발)

  • 최헌종;이석우;김대중;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.793-797
    • /
    • 2000
  • The environmental problems by using coolant demanded the new cooling methods. As one of them the studies on the dry grinding with compressed cold air have been done. The cooling method using compressed cold air was effdve thmugh going down the temperature of compressed air supplied below $-25^{\circ}C$ and inneasing the amount of mmpresd cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using MQL(Minimum Quantity Lubrication) or mist newly were suggested. These two methods can satisfy both cooling effect and lubrication with only small amount of coolant, also has the benefit in the point of decreasing the envimnmental pollution. This paper focused on analyzing the grindmg characteristics of the cooling method using mid. The generated heat and grinding force of the cooling method using mist were compared with them of coolant and compressed cold air. And them grinding test according to the temperature of compressed cold air, mist spray amount and mist supply direction were done.

  • PDF

A Comparative Study of Clothes-Wearing Behaviors According to Differences in Indoor Heating Systems and Cold Sensitivity (난방방식과 추위민감도에 따른 착의행동)

  • Zhang, Chong;Jun, Dae Geun;Jeong, Woon Seon
    • The Korean Journal of Community Living Science
    • /
    • v.26 no.1
    • /
    • pp.115-126
    • /
    • 2015
  • The study investigates the clothes-wearing behaviors of female college students based on differences in indoor heating systems and cold sensitivity. The respondents included a total of 281 female college students living in South Korea and China. Data were analyzed through an ANOVA and, a paired t-test based on SPSS 21.0. Korean students were less dependent on winter clothing than Chinese students for the whole body parts except for the trunk. Korean students were more likely to feel coldness more but wore less clothing. Korean students' clothes-wearing behaviors with respect to coldness depended on the indoor heating system. Korean students tended to buy warmer clothing, although they preferred not to wear undergarments and tended to wear and to wear less winter clothing. Chinese students showed more active clothes-wearing behaviors to keep their feet warm. Finally, groups divided by indoor heating systems and cold sensitivity showed different clothes-wearing behaviors in comparison to those groups based only on indoor heating systems. Even in similar weather conditions, clothes-wearing behaviors for cold adaptation depended on the indoor heating systems and cold sensitivity. The results suggest that this perspective should be taken into consideration when evaluating clothes-wearing behaviors of certain groups or individuals.

The Effects of TENS and cold application on secondary thermal hyperalgesia in rats induced by muscle pain (근통증이 유발된 흰쥐에 있어 TENS와 냉적용이 이차성 열 통각과민에 미치는 영향)

  • Chae Yun-Won;Kim Sang-Yub;Kim Jin-sang;Park Rae-joon;Gu Hyun-mo;Lim Chang hun
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.181-194
    • /
    • 2004
  • The aim of this study was to investigate the effects of TENS and cold application on secondary thermal hyperalgesia in rats induced by muscle pain. Muscle pain was induced in male Sprague-Dowley rats by intra-muscular injection of gastrocnemius with $3\%$ carrageenan. The paw withdrawal latency(PWL) and tail flick test(TFT) to heat were used to detect secodary thermal hyperalgesia induced by the muscle pain. PWL and TFT were quantified before and 4, 10, and 24 h after induction of muscle pain and after application of TENS(100Hz, $100{\mu}s$, sensory intensity) and cold($4^{\circ}C$). TENS and cold significantly reduced the PWL and TFT to heat stimuli when compared with controls receiving no TENS and cold(p<.05). These results suggested that application of TENS and cold attributed to decrease secodary thermal hyperalgesia in rat induced by muscle pain.

  • PDF

Axenic purification and cultivation of an Arctic cyanobacterium, Nodularia spumigena KNUA005, with cold tolerance potential for sustainable production of algae-based biofuel

  • Hong, Ji-Won;Choi, Han-Gu;Kang, Sung-Ho;Yoon, Ho-Sung
    • ALGAE
    • /
    • v.25 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • A psychrotolerant cyanobacterium, Nodularia spumigena KNUA005, was isolated from a cyanobacterial bloom sample collected near Dasan Station in Ny-${\AA}lesund$, Svalbard Islands during the Arctic summer season. To generate an axenic culture, the isolate was subjected to three purification steps: centrifugation, antibiotic treatment and streaking. The broad antibacterial spectrum of imipenem killed a wide range of heterotrophic bacteria, while the cyanobacterium was capable of enduring both antibiotics, the remaining contaminants that survived after treatment with imipenem were eliminated by the application of an aminoglycoside antibiotic, kanamycin. Physical separation by centrifugation and streaking techniques also aided axenic culture production. According to the cold-tolerance test, this mat-forming cyanobacterium was able to proliferate at low temperatures ranging between 15 and $20^{\circ}C$ which indicates the presence of cold-tolerance related genes in N. spumigena KNUA005. This suggests the possibility of incorporating cold-resistance genes into indigenous cyanobacterial strains for the consistent production of algae-based biofuel during the low-temperature seasons. Therefore, it is needed to determine the cold-tolerance mechanisms in the Arctic cyanobacterium in the next research stage.

The Digital Cold War Argument and the Internet Governance (디지털 냉전론과 인터넷 거버넌스)

  • Kim, Jae Yeon
    • Review of Korean Society for Internet Information
    • /
    • v.14 no.3
    • /
    • pp.35-51
    • /
    • 2013
  • The Digital Cold War argument has become one of the heatedly discussed foreign policy agendas in the U.S. Considering the authority and power of the U.S. government and Internet companies in the cyberspace, this shift is not negligible in understanding not only the changes in the U.S. foreign and military policies but also that in the operations of the global Internet governance. Given these circumstances, I seek to explain the origins of and test the theoretical validity of the Digital Cold War argument. In particular, I analyze how the political concerns of the Chinese authorities shaped the characteristics of their control of the domestic Internet and their approach to the global Internet governance. The findings indicate that the Chinese way of the Internet governance is more concerned of their domestic political stability than overthrowing the current Internet governance regime, which many supporters of the Digital Cold War argument cited as the key evidence of such political contentions. Though the Digital Cold War argument is theoretically unwarranted, its growing popularity and the historical lessons of the Cold War have broad implications to the understanding of the impacts of the great power rivalries on the future Internet governance.

  • PDF

Optimized Design of a Cold Plate Heat Sink using FEM and Optimization (유한요소법과 최적설계기법을 활용한 히트싱크 콜드 플레이트 최적 설계)

  • Hong, S.;Seo, H.;Kim, J.;Sim, J.;Hwang, J.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.419-424
    • /
    • 2014
  • In order to improve efficiency, an outdoor unit using a refrigerant cooling method is designed into many air conditioner systems. The heat exchanger is composed of a Cu tube and an plate. The optimal design for the cold plate is very important because the efficiency of the heat transfer depends on the contact area between the Cu tube and the cold plate. The current study focused on the design of the cold plate to obtain a uniform contact between the Cu tube and the cold plate. Both FE(finite element) analysis and optimization were used in the design. The contact area between the tube and plate was predicted and improved by 16% through the press forming simulations. The springback after press forming was also reduced when the optimized design parameters were used. To verify the validity of the optimal cold plate design, a verification test was conducted. As a result, the performance of the heat exchanger improved by 34% when compared to benchmarked products.

Column design of cold-formed stainless steel slender circular hollow sections

  • Young, Ben;Ellobody, Ehab
    • Steel and Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.285-302
    • /
    • 2006
  • This paper describes the design and behaviour of cold-formed stainless steel slender circular hollow section columns. The columns were compressed between fixed ends at different column lengths. The investigation focused on large diameter-to-plate thickness (D/t) ratio ranged from 100 to 200. An accurate finite element model has been developed. The initial local and overall geometric imperfections have been included in the finite element model. The material nonlinearity of the cold-formed stainless steel sections was incorporated in the model. The column strengths, load-shortening curves as well as failure modes were predicted using the finite element model. The nonlinear finite element model was verified against test results. An extensive parametric study was carried out to study the effects of cross-section geometries on the strength and behaviour of stainless steel slender circular hollow section columns with large D/t ratio. The column strengths predicted from the parametric study were compared with the design strengths calculated using the American Specification, Australian/New Zealand Standard and European Code for cold-formed stainless steel structures. It is shown that the design strengths obtained using the Australian/New Zealand and European specifications are generally unconservative for the cold-formed stainless steel slender circular hollow section columns, while the American Specification is generally quite conservative. Therefore, design equation was proposed in this study.