• 제목/요약/키워드: Cold test

Search Result 1,537, Processing Time 0.026 seconds

Performance of Imported Sweet Corn Hybrids in Korea

  • Seo, Seo-Jung;Yun, Yun-Sang;Lee, Lee-Suk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.4
    • /
    • pp.305-310
    • /
    • 2002
  • The performance of 7 sugary (su) and 12 shrunken-2 (sh2) sweet com hybrids which are commercially grown in the United States was tested in Korea. The 100-seed weight of su hybrids (16.5-23.6 g) was much heavier compared to that of sh2 hybrids (10.9-17.5 g). The germination rate of su and sh2 hybrids at $25^{\circ}C$ ranged 93.3-100% and 86.7-98.9%, the emergence rate of su and sh2 hybrids in cold test ranged 78.9-97.8% and 62.2-97.8%, and field emergence rate of su and sh2 hybrids ranged 74.4-100.0% and 79.9-98.2%, respectively. In su hybrids, there was a significantly positive correlation between germination rate at $25^{\circ}C$ and emergence rate in cold test or early growth. In contrast, in sh2 hybrids seed weight was positively correlated with early plant growth, while not with the germination rate at $25^{\circ}C$ or emergence rate in cold test and field. Most sh2 hybrids produced larger and more marketable ears compared to su hybrids although there were significant differences among the hybrids in the same genotype. At harvest (24 days after pollination) soluble solids content of su hybrids (24.3-27.1 Brix %) was much higher than that of sh2 hybrids (13.8-18.0 Brix %), while total sugars of sh2 hybrids (21.4-28.6% on the dry weight basis) was much higher compared to su hybrids (2.4-15.9%). Considering germination and emergence rates, marketable ear production, and total sugar content, 'GCB 70' and 'Sweet Satin' in su hybrids and 'Ice Queen', 'Aspen', 'Sweet Magic', 'Bandit', 'Xtrasweet 82', 'Aspen', and 'Cambella 90' in sh2 hybrids performed better than other hybrids.

Comparison of the effects of two oral cares on thirst and oral status following nasal surgery: Oral swab versus non-swab using cold water gauze (비강수술 후 구강간호 방법에 따른 갈증과 구강상태 효과 비교: 냉수 거즈 활용 구강 내 닦아주기와 냉수 거즈 물려주기)

  • Gu, Anna;Yu, Mi;Kim, Youngjin;Park, Suyeon;Baek, Kyunghee;Kim, Taehee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.28 no.3
    • /
    • pp.317-327
    • /
    • 2022
  • Purpose: This study aimed to compare the effects of oral swab and non-swab using cold water gauze on patients' thirst and oral status following nasal surgery under general anesthesia. Methods: A non-equivalent control group was applied. Participants were divided into a control group (n=30) that was treated by cared for with cold water gauze application without oral swab and an experimental group (n=29) that was treated cared for with oral swab using cold water gauze after nasal surgery at the G University Hospital in Korea. Data were collected from May 14, 2020, to April 30, 2021, and analyzed using descriptive statistics, a chi-squared test, independent t-test, Wilcoxon signed-ranks test, and Mann-Whitney test. Results: The results showed no significant differences between the two groups in thirst (U=-0.04, p=.693) and overall oral condition (U=-0.34, p=.813) after the intervention. However, participants' thirst and oral condition were significantly improved in each group after intervention. Conclusions: It was confirmed that both oral care methods reduced thirst and improved oral condition after nasal surgery. These findings indicate the need for intervention for patients' thirst and oral condition after nasal surgery. Furthermore, they show that these oral care protocols can be used as a safe and effective nursing intervention for patients who undergo nasal surgery under general anesthesia.

Distortional buckling performance of cold-formed steel lightweight concrete composite columns

  • Yanchun Li;Aihong Han;Ruibo Li;Jihao Chen;Yanfen Xie;Jiaojiao Chen
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.675-688
    • /
    • 2024
  • Cold-formed steel (CFS) is prone to buckling failure under loading. Lightweight concrete (LC) made of lightweight aggregate has light weight and excellent thermal insulation performance. However, concrete is brittle in nature which is why different materials have been used to improve this inherent behavior of concrete. The distortional buckling (DB) performance of cold-formed steel-lightweight concrete (CFS-LC) composite columns was investigated in this paper. Firstly, the compressive strength test of foam concrete (FC) and ceramsite concrete (CC) was carried out. The performance of the CFS-LC members was investigated. The test results indicated that the concrete-filled can effectively control the DB of the members. Secondly, finite element (FE) models of each test specimen were developed and validated with the experimental tests followed by extensive parametric studies using numerical analysis based on the validated FE models. The results show that the thickness of the steel and the strength of the concrete-filled were the main factors on the DB and bearing capacity of the members. Finally, the bearing capacity of the test specimens was calculated by using current codes. The results showed that the design results of the AIJ-1997 specification were closer to the experimental and FE values, while other results of specifications were conservative.

Analysis of Clinical Research Trends on Cold-Heat Pattern Identification in Korea - Focused on Quantitative Indicators for General People (한열변증의 국내 임상연구 동향 분석 - 일반인의 정량지표를 중심으로)

  • Yeo, Min Kyung;Lee, Young Seop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.145-152
    • /
    • 2017
  • The purpose of this study was to investigate the clinical research of Cold-Heat of pattern identification(PI) focused on quantitative indicators for general people in Korea, through the review of OASIS, KISS, DBpia, NDSL database. Ten clinical researches were analyzed in this study. These research gradually started from 2004 to 2009 but there was no research after 2010. Diagnosis of Cold-Heat PI all was done through a questionnaire, 7 or most researches had not used the intervention methods. Quantitative indicators related to the Cold-Heat PI mentioned in the selected 10 researches are seven, these indicators include heart rate variability(HRV), electroencephalogram, Yangdorak, respiratory index, electrogastrography, acoustic analysis index, western health test index. Related to the HRV were 3 researches, but correlation of significant indicators was a few levels(R=0.026-0.090). So far, studies regarding at the quantitative indicators of the prior the Cold-Heat PI were few, and the results of the study showed that low statistical precision, a lack of biological basis. Refer to the current state, in the future, we expect that research of quantitative indicators of scientific evidence-based through calculated and precise research concerning Cold-Heat PI be regarded as important in Korean Medicine.

Expression of spinal cord c-fos with cold therapy in rats of carrageenan-induced inflammatory muscle pain (Carrageenan으로 유도된 염증성 근통증 흰쥐 모델에서 냉치료에 의한 척수의 c-fos의 발현)

  • Paek Yun-Woong
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.190-198
    • /
    • 2003
  • Expression of c-fos, an immediate early gene, has accepted to be a marker of functional activity in neurons. This study was aimed to investigate the effects of cold therapy on the expression of spinal cord c-fos in rats of carrageenan-induced muscle pain. Muscle pain was induced in male Sprague-Dawley rats by intra-muscular injection of gastrocnemius with $2\%$ carrageenan. The paw withdrawal latency (PWL) and tail flick test (TFT) responses to heat stimuli were used to detect secondary hyperalgesia produced by the muscle pain and measured to assess the effects of cold. The expression of c-fos was determined in the lumbar regions of the spinal cord by reverse transcription-polymerase chain reaction (RT-PCR) and immunohistochemistry assays. The secondary hyperalgesia to heat simuli (PWL and TFT) were significantly reduced in cold therapy compared with that in the controls. In RT-PCR assays the expression of c-fos mRNA was down-regulated in the lumbar spinal cord in cold group. In addition, Fos immunoreactivity in the dorsal horn of the lumbar spinal cord was decreased in cold group. These results suggested that application of cold attributed to increase PWL and TFT responses and to decrease expression of the c-fos produced by muscle pain.

  • PDF

Server Room Temperature Condition in Data Center with Cold Aisle Containment System (냉복도 밀폐시스템을 적용한 서버실의 실내온도조건)

  • Jung, Yong-Ho;Chang, Hyun-Jae;Seo, Jang-Hoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.79-84
    • /
    • 2013
  • In this study, a cold aisle containment system was proposed among various strategies to reduce the energy waste by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, a test bed which is similar to an actually existing server room was set up in the Internet Data Center(IDC) building. Comparative experiments, conventional open type cooling system and cold aisle containment system were carried out under actual conditions. The result revealed that the range of inlet temperature of the server system was $20{\sim}25^{\circ}C$ in an existing cooling system and the range of inlet temperature dropped below $20^{\circ}C$ by the cold aisle containment system. After all, cold aisle containment system was proved to be the solution for energy saving cooling system.

Study on the Stability Test of Impinging(FOOF) Injector on $GN_2$ Purge Cold Flow Test (질소분사 음향시험을 통한 충돌형(FOOF) 분사기의 안정성 평가에 관한 연구)

  • Yoo Doc-Koon;Lee Kwang-Jin;Seo Seong-Hyeon;Han Young-Min;Choi Hwan-Seok;Seol Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.135-140
    • /
    • 2006
  • In the experimental study of $N_2$ purge cold flow test of impinging(FOOF) injector for determining of instability region, the whistling sound which has a specific frequency is generated. The frequency of whistling is proportional to the gas flow velocity in part of the oxidizer orifice and due to the coupling of the vibrating gas column and the natural frequency of pipe-orifice shape, the discontinuous jumping phenomena arises. The whistling phenomena have no effect on the combustion instability. Compared the damping factor of 1T1L mode with the hot fire test, the instability region of $N_2$ purge cold flow test is very much like that. It means that flow instability by impinging or mixing of jet is the main reason of combustion instability of impinging injector(FOOF) in the hot firing test.

  • PDF

Cold flow Test and Ignition Test of a 75-tonf-Class Thrust Chamber with Ablative Material for Technology Demonstration (75톤급 기술검증용 내열재 연소기의 수류시험과 점화시험)

  • Lee, Kwang-Jin;Kim, Jong-Gyu;Kim, Mun-Ki;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.26-37
    • /
    • 2011
  • A 75-tonf-class LRE(liquid rocket engine) thrust chamber with ablative material for technology demonstration was manufactured on the basis of development technologies of 30-tonf-class LRE. Hydraulic characteristics of the thrust chamber were examined through cold flow test and ignition test of low flow condition. Test result showed that hydraulic function was good. Side ignition method with igniter ring also showed a fine function of ignition in operating ways of static condition. But a close review is required to understand the phenomena of generation and extinction of specific frequencies showed in dynamic characteristics ways. To achieve these, a large combustion test facility which is capable of performing combustion test at design condition of the 75-tonf-class thrust chamber should be constructed as soon as possible.

The Evaluation of Surface and Adhesive Bonding Properties for Cold Rolled Steel Sheet for Automotive Treated by Ar/O2 Atmospheric Pressure Plasma (대기압 Ar/O2 플라즈마 표면처리된 자동차용 냉연강판의 표면특성 및 접착특성평가)

  • Lee, Chan-Joo;Lee, Sang-Kon;Park, Geun-Hwan;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.4
    • /
    • pp.354-361
    • /
    • 2008
  • Cold rolled steel sheet for automotive was treated by Ar/$O_2$ atmospheric pressure plasma to improve the adhesive bonding strength. Through the contact angle test and calculation of surface free energy for cold rolled steel sheet, the changes of surface properties were investigated before and after plasma treatment. The contact angle was decreased and surface free energy was increased after plasma treatment. And the change of surface roughness and morphology were observed by AFM(Atomic Force Microscope). The surface roughness of steel sheet was slightly changed. Based on Taguchi method, single lap shear test was performed to investigate the effect of experimental parameter such as plasma power, treatment time and flow rate of $O_2$ gas. Results shows that the bonding strength of steel sheet treated in Ar/$O_2$ atmospheric pressure plasma was improved about 20% compared with untreated sheet.

A Study on the fracture behavior of surface hardening treated aluminum alloy under the high velocity impact (고속충격을 받는 표면처리된 알루미늄 합금의 거동에 관한 연구)

  • 손세원;김희재;황도연;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.784-789
    • /
    • 2001
  • In order to investigate the fracture behaviors(penetration modes) and the resistance to penetration during ballistic impact of cold-rolled Al 5052 H34 alloy laminates, anodized Al 5052 H34 alloy laminates, and Al 5052 H34 alloy after cold-rolling, ballistic testing was conducted. In general, superior armor material is brittle materials which have a high hardness. Ballistic resistance of these materials was measured by protection ballistic limit(V50), a statical velocity with 50% probability for incomplete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are observed respectfully, resulting from V50 test and Projectile Through Plate(PTP) test at velocities greater than V50. PTP tests were conducted with 0$^{\circ}$obliquity at room temperature using 5.56mm ball projectile. V50 tests with 0$^{\circ}$obliquity at room temperature were also conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface Hardness, resistance to penetration, and penetration modes of Al 5052 H34 alloy laminates compared to those of cold-rolled Al 5052 H34 alloy laminates and anodized Al 5052 H34 alloy laminates anodized Al 5052 H34 alloy after cold-rolling.

  • PDF