• Title/Summary/Keyword: Cold heat storage

Search Result 138, Processing Time 0.022 seconds

Cold Plasma Treatment Effects on the Physicochemical and Biodegradable Properties of a Corn Biomass-containing Polyester Film (옥수수 바이오매스를 함유한 폴리에스터 필름의 물리 화학적 특성과 생분해 특성에 대한 콜드 플라즈마 처리의 영향)

  • Song, Ah Young;Oh, Yoon Ah;Oh, Se Jun;Min, Sea Cheol
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.2
    • /
    • pp.224-232
    • /
    • 2015
  • The effects of cold plasma (CP) treatments on the physicochemical and biodegradable properties of a corn biomass-containing polyester (CBPE) film were studied. The CBPE film was treated with CP generated by $N_2$, $O_2$, He, Ar, or dry air at 400-900 W and 667 Pa for 10-40 min. The glass transition temperature of the CBPE film ($-30.2--28.6^{\circ}C$) was not affected by the CP treatment, while the elastic modulus and water vapor permeability decreased (p<0.05). The ink printability was improved by the treatment and the improved printability was maintained during storage for 56 days at room temperature. Roughness of the film increased after treatments and the level of roughness appeared to increase during storage. Heat and microbial biodegradability of the CBPE film was improved by the air-CP treatment (p<0.05). These results have demonstrated the potential of applying CP treatments to improve the flexibility, printability, and biodegradability of CBPE films.

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

Study on Manufacturing and Characteristics of Phase Change Materials for Having Latent Heat (열저장 물질로써 잠열재의 제조 및 특성 연구)

  • Kwon K.H.;Jeong J.W.;Choi C.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.168-174
    • /
    • 2006
  • The purpose of this study is to develop the cold chain system by developing optimal phase change materials (PCM). There are some benefits from developing this system such as keeping freshness of agriculture products, saving energy, etc. The major results are as follows. To decide a latent heat material, the characteristics of water, sodium, polyacrylate, ethanol and N-tetradecane are analysed. Also, an insulating material is made by mixing water, nucleating agent and latent heat material, using cementing method. In addition, the sensitivity analysis for developed latent heat material($K_l,\;K_2,\;K_3$) is conducted. For $K_l,\;K_2,\;K_3$ which cans keep latent heat temperature, ranging from $0\;to\;5^{\circ}C,\;5\;to\;10^{\circ}C,\;10\;to\;15^{\circ}C$. it can keeps latent heat temperature at radiant heat (5, 12, $17^{\circ}C$) and transportation latent heat container both melting temperature and amount of latent heat of Kl are $-1.6{\pm}1.0^{\circ}C$, 326.51 J/g, respectively and freezing temperature and latent heat are $-7.98{\pm}1.5^{\circ}C$ and 174.18 J/g. and $K_2$ are $7.41{\pm}1.5^{\circ}C$, 89.80 J/g, respectively and freezing temperature and latent heat are $-2.14{\pm}1.5^{\circ}C$ and 83.90 J/g. and $K_3$ are $9.54{\pm}1.0^{\circ}C$, 145.42 J/g, respectively and freezing temperature and latent heat are $0.21{\pm}1.0^{\circ}C$ and 152.48 J/g.

A Study on the Estimation of Temperature, Humidity and Cooling Load (온도, 습도 및 냉방부하 예측에 관한 연구)

  • Yoo, Seong-Yeon;Han, Seung-Ho;Lee, Je-Myo;Han, Kyou-Hyun;Noh, Kwan-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.80-85
    • /
    • 2006
  • The peak demand of electricity in summer season mainly comes from the day time cooling loads. Ice thermal Storage System (ITSS) uses off-peak electricity at night time to make ice for the day time cooling. In order to maximize the use of cold storage in ITSS, the estimation of day time cooling load for the building is necessary. In this study, we present a method of cooling load estimation using 5 years of normalized outdoor temperature, relative humidity, and the building construction data. We applied the hourly-based estimation to a general hospital building with relatively less sudden heat exchange and the results are compared with the measured cooling load of the building. The results show that the cooling loads estimation depends on the indoor cooling design temperature of the building.

  • PDF

Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern (냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구)

  • 이대혁;김호영
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.142-151
    • /
    • 2002
  • Claesson(2001)'s analytical solution, and two numerical models with Dirichlet and Neuman interior boundary condition respectively were investigated to estimate the transient temperature distribution with distances from the Taejon underground food cold storage pilot cavern. Claesson's solution, which is based on constant temperature boundary condition at the rock wall during a temperature decline step, showed relatively good agreement with temperature measurements in the rock mass in order of average error difference, 0.89$\^{C}$ without any adjustments on laboratory thermal properties to represent the rock mass. For the numerical model with heat flux through the rock wall, a boundary condition setting technique was newly proposed to overcome the difficulty of prescribing variable convective heat tranfer coefficient and far-field air temperature inside the cavern as they may be certainly changed according to the cooling-down time. The results showed also good agreement with measurements in order of average error difference, 1.58$\^{C}$, and were compared to those of the numerical model with fixed temperature at the rock wall. Finally, the most proper procedure to precisely predict the temperature profile around a cavern was proposed as a series of analysis steps including an analytical exact solution and numerical models.

A Study on the Thermal Properties of Binary Eutectic Mixed PCM Using Polyethylene Glycol and 1,4-Butanediol (Polyethylene glycol과 1,4-Butanediol을 활용한 이원 공융혼합 PCM의 열적 특성에 관한 연구)

  • Jooyoung Park;Kitae Park;Jongchul Seo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.30 no.2
    • /
    • pp.101-106
    • /
    • 2024
  • Current cold chain logistics relying on organic or eutectic materials within the 2~8℃ range as secondary fluids often face limitations in heat storage capacity, necessitating high energy consumption and large volume capacity. An effective approach to address this challenge is by incorporating polymers to enhance the heat storage capacity of eutectic materials. In this study, we investigated the impact of polyethylene glycols (PEGs) on phase change materials using Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimeter (DSC), analyses of endothermic and exothermic phase change processes, and an accelerated thermal cycling test. Our findings indicate that the introduction of PEGs into the phase change materials can lead to improvements in latent heat, thermal conductivity, and 2~8℃ retention time. This enhancement is attributed to the high latent heat and thermal conductivity of the polymer, along with its ability to inhibit crystal formation in the eutectic mixture.

Establishment of the Successive Rearing System of Brush-footed Butterflies (Lepidoptera: Nymphalidae) (네발나비과 나비류의 계대사육법 체계확립)

  • Seol, Kwang-Youl;Kim, Nam-Jung;Hong, Seong-Jin
    • Korean journal of applied entomology
    • /
    • v.44 no.4 s.141
    • /
    • pp.257-264
    • /
    • 2005
  • In order to establish the successive rearing system brush-footed butterflies (Lepidoptera : Nymphalidae) were reared in a room. Artificial diets were developed for a year-round rearing. Bu-diet was best to rear these butterflies among 3 kinds of diet used. The freeze-dried host plant leaf powder in diet was better than heat-dried one $(60^{\circ}C)$ in the growth of larvae. The rearing results were best in the diet C/N ratio was 1:1. The 24-hrs old eggs could be stored for 5 days at $15^{\circ}C$ or for 3 days at $5^{\circ}C$ and showed 75% of hatchability. On the other hand, pupae could be stored for maximum 15 days at $15^{\circ}C$ because the emergence of abnormal adults appeared much more as the cold storage period got longer. And the adult was able to be stored until 60 days at refrigerator without relation of nectar-sucking period before cold-storage and storage temperature. Also a simple artificial ovipositing kit was devised by ${\Phi}9$ cm of petri-dish and a female oviposited $278{\pm}27$ of eggs with adding the ether extract of host plant to this kit. The systematic successive rearing method of brush-footed butterflies in a room was completed.

Evaluation of the Characteristics of the Aluminum Alloy Casting Material by Heat Treatment (AC8A 알루미늄합금 주조재의 열처리에 의한 특성 평가)

  • Lee, Syung Yul;Park, Dong Hyun;Won, Jong Pil;Kim, Yun Hae;Lee, Myung Hoon;Moon, Kyung Man;Jeong, Jae Hyun
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.280-285
    • /
    • 2012
  • Aluminum is on active metal, but it is well known that its oxide film plays a role as protective barrier which is comparatively stable in air and neutral aqueous solution. Thus, aluminum alloys have been widely applied in architectural trim, cold & hot-water storage vessels and piping etc., furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston because of its properties of temperature and wear resistance. In recent years, the oil price is getting higher and higher, thus the using of low quality oil has been significantly increased in engines of ship and vehicle. Therefore it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and prolong its lifetime. In this study, the effect of solution and tempering heat treatment to corrosion and wear resistance is investigated with electrochemical method and measurement of hardness. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment and exhibited the highest value of hardness with tempering heat treatment temperature at $190^{\circ}C$ for 24hrs. Furthermore, corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. As a result, it is suggested that the optimum heat treatment to improve both corrosion and wear resistance is tempering heat treatment temperature at $190^{\circ}C$ for 16hrs.

Conceptual Design of Turbine Exhaust System for 3rd stage of Launch Vehicle (한국형발사체 3단 터빈배기부 개념설계)

  • Shin, DongSun;Kim, KyungSeok;Han, SangYeop;Bang, JeongSuk;Kim, HyenWoong;Jo, DongHyuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1068-1071
    • /
    • 2017
  • The turbine exhaust system consists of a turbine flange, heat exchanger, exhaust duct and thrust nozzle. Heat exchanger is used for the launch vehicle because of the advantage of reducing the weight of the helium gas and the storage tank by using the heat exchanger pressurization method compared to the cold gas pressurizing method. Since the gas generator is combusted in fuel-rich condition, the soot is contained in the combustion gas. Hence, the heat exchanger should be designed considering the reduction of the heat exchange efficiency due to the soot effect. In addition, the uncertainty of the heat exchange calculation and the evaluation of the influence of the combustion gas soot on the heat exchange can not be completely calculated, so the design requirements must include a structure that can guarantee and control the temperature of the heat exchanger outlet. In this paper, it is described that the component allocation, the design method considering the manufacture of internal structure, the advantages of new concept of nozzle design.

  • PDF

Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer (화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안)

  • 김상욱;한종훈;황용준;이건홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF