• Title/Summary/Keyword: Cold environment

검색결과 922건 처리시간 0.032초

우리나라의 겨울철 기온 변화 및 한파 발생빈도 분석 (An Analysis of a Winter-time Temperature Change and an Extreme Cold Waves Frequency in Korea)

  • 전미정;조용성
    • 한국기후변화학회지
    • /
    • 제6권2호
    • /
    • pp.87-94
    • /
    • 2015
  • To compare changes in winter temperature over South Korea, 30-year average climate data and climate data of recent 10 years (2014~2014) such as mean temperature, daily maximum temperature and daily minimum temperature were analyzed. Also, we set analysis extreme cold waves frequency related to winter such as freezing days, snow days, days with temperature of below -5, and days with temperature of below -10. This process enabled the comparative analysis of winter temperature changes and extreme cold waves frequency related to winter. This study estimated that winter temperature has gradually increased throughout the last five decades, however, the frequency of extreme weather, such as cold waves has also increased.

HCA AND TWC HYBRID SYSTEM FOR REDUCING COLD-START EMISSION

  • Lee, S.C.;Jang, J.H.;Lee, B.Y.;Bae, J.H.;Choung, S.J.
    • International Journal of Automotive Technology
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2004
  • In line with the Super Ultra Low Emission Vehicle (SULEV) regulation, the main idea in this study has been focused on the utilization of hydrocarbon adsorber (HCA) to adsorb the excess hydrocarbons emitted during a period of engine cold-start, As main recipes of HCA materials, many types of zeolite as well as the combination of alumina and precious metals were used, Representative physico-chemical factors of zeolite such as acidic and hydrophobic properties were characterized. The optimum recipe of HCA materials was also determined. Among the acid properties of zeolites, the Si/Al ratio was found to be the most important factor to get higher hydrocarbon adsorption capacity.

철도건설의 환경적 가치평가연구 (An Appraisal of Environmental Value of Railroad Construction)

  • 정성봉
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.357-363
    • /
    • 2011
  • In spite of numerous advantages in railroads such as mass transportation, high reliability, and environmental soundness etc., the value of railroad construction is relatively underestimated compared to road. This is because the current method of evaluation focuses mainly on economic effect. In this study, considering recent research results, the environmental value of railroad construction was assessed by calculating the effect of reduction of emissions and water contamination. With these two benefits, the environmental effect produced by railroads and road construction was calculated and compared to each other using EMME/3. As a result, the senario 4 which considers 'Hot/Cold start' condition and water contamination had highest benefits. Furthermore, the environmental effect produced by railroad is 55~101% higher than road construction. If the suggested method is used in the current appraisal system, the environment-friendly mode like railway would be highly valued, much more than before.

유역의 찬공기 특성을 고려한 도시 바람길 활용 전략 - 경기도 의정부 및 과천 일대를 사례로 - (Strategies for utilizing Urban Ventilation Corridor considering Local Cold Air in Watershed Areas - A Case Study of Uijeongbu and Gwacheon -)

  • 엄정희
    • 한국지리정보학회지
    • /
    • 제22권2호
    • /
    • pp.133-151
    • /
    • 2019
  • 본 연구는 찬공기 특성을 유역단위로 분석하고, 유역 내 생성되는 찬공기를 도시 바람길 계획에서 활용하는 방안을 제안하는 것을 목적으로 한다. 이를 위해, 경기도 지역의 북쪽에 위치한 중랑천 유역의 의정부시, 남쪽에 위치한 안양천 유역 및 양재천 탄천 유역의 과천시를 연구 대상지로 선정하였다. 찬공기 특성 분석을 위해 독일에서 개발된 모형인 KALM(Kaltluftabflussmodell)을 활용하였으며, 야간 6시간 동안 생성되는 찬공기 흐름 및 찬공기층 높이를 파악하였다. 중랑천 유역의 주요 바람길이 흐르는 곳에 위치해 있는 의정부시는 남쪽 외곽에서부터 유입된 찬공기가 의정부시 전체 바람길 계획의 중요한 부분을 차지하고 있다. 또한, 서쪽의 사패산 일대에서 생성된 찬공기는 시청 인근의 중심상업지구까지 유입되고 있어 도심의 열환경을 조절하는 주요한 역할을 수행하는 것으로 판단된다. 반면, 의정부시 동쪽지역은 바람길 이용이 원활하지 않는 것으로 파악되었다. 동쪽의 관악산과 서쪽의 청계산 등에서 생성된 찬공기 흐름은 과천시의 북쪽 지역에서 가장 활발하였는데, 이 흐름은 안양천 및 양재천 탄천 유역 전체에서도 주요한 바람길이다. 이에 비해, 찬공기 흐름이 원활하지 않은 남쪽지역에 '과천지식정보타운 공공주택지구' 조성이 계획되어 있어 향후 이 지역의 주거환경이 저하될 가능성이 크다. 향후, 이 지역을 개발할 경우 상세한 바람길 분석을 통한 바람길 활용 계획을 추가적으로 수립할 것을 제안하였다.

어린이집 급식실 정수기의 미생물학적 오염 평가 (Prevalence of Microbiological Contamination on Water Purifiers at Lunchroom in Child Care Center)

  • 윤미혜;김중범;오혁수
    • 한국식품조리과학회지
    • /
    • 제28권5호
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the prevalence of microbiological hazard on water purifiers at lunchroom in child care center was investigated. A total of 49 water purifiers and their purified cold water were sampled to test about the total aerobic bacteria, coliform bacteria, Bacillus cereus, Staphylococcus aureus, and Salmonella spp. Total aerobic bacteria was detected over 2.0 log CFU/mL in 6 out of 49 purified cold water (12.2%), ranged from 2.0 to 2.4 log CFU/mL, and the average number of total aerobic bacteria was showed to be 3.3 log CFU/drain spout. The drain spout turned out to be a major contaminant in water purifier and needs to be improved. Coliform bacteria were also detected in 7 out of 49 cold faucets (14.3%) and 7 out of 49 drain spouts (14.3%), but not detected in purified cold water. All samples were not contaminated with the pathogens tested in this study, except for B. cereus, which was contaminated on 2 out of 49 cold faucets (4.1%) and 4 out of 49 drain spouts (8.2%). All of B. cereus isolates produced enterotoxin, such as heamolysin BL enterotoxin (HBL) or non-heamolytic enterotoxin (NHE). The HBL was detected in 5 out of 6 B. cereus isolates (83.3%), including B. cereus PCF-11 and B. cereus PDS-30 isolate only produced NHE (16.7%). These results showed that the sanitary conditions of cold faucets and drain spouts should be improved promptly.

하계 용승현상에 따른 간절곶 주변해역의 냉수역 구조와 변동 (Variation and Structure of the Cold Water Around Ganjeol Point Off the Southeast Coast of Korea)

  • 추효상
    • 해양환경안전학회지
    • /
    • 제22권7호
    • /
    • pp.836-845
    • /
    • 2016
  • 본 연구에서는 하계 한국 남동해 간절곶 주변해역의 냉수대 구조와 변동을 CTD 관측과 수층별 수온 장기 연속 모니터링 자료를 이용하여 분석하였다. 냉수대의 표층수온은 냉수기 이전과 $-12^{\circ}C$의 차이를 보였으며 해저지형 효과로 간절곶에서 냉수대 세력이 가장 컸다. 남북해역 간 등온선의 시계열분포에 간절곶을 경계로 공간변화가 발생해 간절곶 주변 해저지형이 언덕(hill)역할을 하고 있음이 추정되었다. 냉수대는 해안에 평행한 풍속이 양(+)의 값일 때 출현하는 연안용승반응을 나타냈고, 수온의 감소와 상승은 풍향이 바뀐 후 하루 이내에 반응하였다. 간절곶 주변은 얕은 수심 주위에서 발생하는 와류효과가 결합하여 바람에 의한 용승효과가 강화되었다. 수온변화는 2~6일 주기의 바람변동에 민감하였으며, 수온감소는 12~36시간의 위상차를 나타냈다. 냉수대가 출현한 7월은 2~3일 주기, 8월은 3~8일 주기에서 바람-수온변화의 상관성이 컸다.

저온의 고-액상변화 모듈 용기의 배열에 따른 축냉시스템의 수치해석 (Numerical Analysis of Cold Storage System with Array of Solid-Liquid Phase Change Module)

  • 문수범
    • 해양환경안전학회지
    • /
    • 제21권5호
    • /
    • pp.577-582
    • /
    • 2015
  • 본 논문은 육해상의 운송장치에 축냉시스템을 적용시키기 위한 기초 연구이다. 또한, 축냉재의 고액상변화에 대한 수치해석을 수행한 연구이다. 수치해석법으로는 유한차분법(Finite-Difference Method)을 이용하였으며, 1차원 비정상의 상태를 가정하여 계산하였다. 또한 용기는 직사각형의 구형용기로 가정하여 대칭의 조건을 이용하였다. 축냉을 목적으로 사용하는 열매체는 염화칼슘 수용액($CaCl_2$) 30wt%의 물성치를 사용하여 계산을 수행하였다. 계산에 영향을 미치는 요소로는 냉동고의 냉기 온도 및 냉기 유속이 있으며, 축냉재를 싸고 있는 용기는 플라스틱으로 가정하였다. 본 수치해석에서 경계층의 두께는 냉기의 속도 증가와 함께 얇게 되고 축열시간도 짧아지는 것을 확인할 수 있었다. 그리고 냉기의 유속이 빨라질수록 열전달이 촉진되어 축냉용기 전면부에서의 온도가 낮아짐을 알았다. 축냉용기의 후면부에서는 경계층이 두꺼워져 열전달이 전면부에 비해 작아짐을 알았다.

Effects of cyclic mean pressure of helium gas on performance of integral crank driven stirling cryocooler

  • Hong, Yong-Ju;Ko, Junseok;Kim, Hyo-Bong;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권3호
    • /
    • pp.30-34
    • /
    • 2016
  • An integral crank driven Stirling cryocooler is solidly based on concepts of direct IR detector mounting on the cryocooler's cold finger, and the integral construction of the cryocooler and Dewar envelope. Performance factors of the cryocooler depend on operating conditions of the cryocooler such as a cyclic mean pressure of the working fluid, a rotational speed of driving mechanism, a thermal environment, a targeted operation temperature and etc.. At given charging condition of helium gas, the cyclic mean pressure of helium gas in the cryocooler changes with temperatures of the cold end and the environment. In this study, effects of the cyclic mean pressure of helium gas on performances of the Stirling cryocooler were investigated by numerical analyses using the Sage software. The simulation model takes into account thermodynamic losses due to an inefficiency of regenerator, a pressure drop, a shuttle heat transfer and solid conductions. Simulations are performed for the performance variation according to the cyclic mean pressure induced by the temperature of the cold end and the environment. This paper presents P-V works in the compression and expansion space, cooling capacity, contribution of losses in the expansion space.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 1 The effects of heating temperatures and testing conditions (hot and cold)

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제2권2호
    • /
    • pp.145-162
    • /
    • 2014
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was determined by conducting three-point bending tests on eighty notched HPC beams of $500mm{\times}100mm{\times}100mm$ at high temperatures up to $450^{\circ}C$ (hot) and in cooled-down states (cold). When the concrete beams exposed to high temperatures for 16 hours, both thermal and hygric equilibriums were generally achieved. $K_{IC}$ for the hot concrete sustained a monotonic decrease tendency with the increasing temperature, with a sudden drop at $105^{\circ}C$. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and rapidly thereafter. The fracture energy-based fracture toughness $K_{IC}$' was found to follow similar decrease trends with the heating temperature. The weight loss, the fracture energy and the modulus of rapture were also evaluated.