• 제목/요약/키워드: Cold engine start

검색결과 100건 처리시간 0.023초

가솔린 엔진의 배기 열교환기가 촉매 온도에 미치는 영향에 관한 연구 (Effect of Exhaust Heat Exchanger on Catalytic Converter Temperature in an SI Engine)

  • 이석환;배충식
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.9-16
    • /
    • 2004
  • Close-coupled catalyst (CCC) can reduce the engine cold-start emissions by utilizing the energy in the exhaust gas. However, in case the engine is operated at high engine speed and load condition, the catalytic converter may be damaged and eventually deactivated by thermal aging. Excess fuel is sometimes supplied intentionally to lower the exhaust gas temperature avoiding the thermal aging. This sacrifices the fuel economy and exhaust emissions. This paper describes the results of an exhaust heat exchanger to lower the exhaust gas temperature mainly under high load conditions. The heat exchanger was installed between the exhaust manifold and the inlet of close-coupled catalytic converter. The exhaust heat exchanger successfully decreased the exhaust gas temperature, which eliminated the requirement of fuel enrichment under high load conditions. However, the cooling of the exhaust gas through the heat exchanger may cause the deterioration of exhaust emissions at cold start due to the increment of catalyst light-off time.

LPG 엔진의 냉 시동시 시동성 개선 및 배출들 저감을 위한 연구 (A Study for the Improvement of Start Ability and Exhaust Emissions in a Conventional Mixer Type LPG Engine on Cold Start)

  • 김우석;이종화
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.84-92
    • /
    • 2002
  • On the cold start of LPG engine, as the engine temperature has not reached its equilibrium temperature, liquid LPG could not be changed perfectly gaseous LPG, although it was passed to the vaporizer. Liquid and gas mixed fuel could influence starting ability and exhaust emission characteristics of LPG engine. In this study, the vaporization characteristic of liquid LPG was investigated with a conventional vaporizer and the vaporizer with heat source(glow plug) installed at preheated chamber inlet, by using the visualization methods and engine test. According to visualization result, even if the engine coolant temperature was $14^{\circ}C$, liquid fuel was supplied to primary chamber over 25 seconds without vaporizing from preheated chamber in such a conventional vaporizer. However, the vaporizer with heat source do not correspond with that, scarcely had been trim on glow plug when LPG began to vaporize. The effectiveness of heat source could be verified by application to the conventional LPG engine.

2차 공기분사 및 냉각수제어에 의한 SI 엔진의 탄화수소 배기저감 (SI Engine Hydrocarbon Emissions Reduction with Secondary Air Injection and Coolant Control)

  • 박기수;조영진;박심수
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.51-58
    • /
    • 2000
  • It is well known that the majority of the emissions measured from vehicle exhaust in the US Federal Test Procedure(FTP-75) are emitted during the first 60 seconds. This paper describes an experimental study on SI engine emissions reduction after cold start with interval secondary air injection and coolant control. Secondary air injection after cold start to reduce exhaust emissions causes an exothermic reaction at the exhaust port and gives sufficient air to the catalyst. For that reason engine-out emissions oxidized in the exhaust port and the rapid heating of a catalytic converter after cold start with CSAI and ISAI are estimated. The influence of the coolant temperature on SI engine emissions has been estimated. In the present studycoolant control of the cylinder head tempeature is used to investigate the effect of coolant temperature on SI engine emissions. The results show that engine-out hydrocarbon and carbon monoxide emissions are considerably reduced with interval secondary air injection and coolant control.

  • PDF

스파크 점화기관에서 이차 공기 분사가 냉시동시 THC 배출량에 미치는 영향에 관한 실험적 연구 (Experimental Study of the Effect of Secondary Air Injection on the Cold Start Total Hydrocarbon Emissions in a Spark Ignition Engine)

  • 이승재;함윤영;전광민
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2003
  • Engine emission regulations are becoming more stringent nowadays. In cold transient regime, about 80% THC is exhausted to the atmosphere in the first 200s (US FTP cycles). Accordingly, reducing emission levels in the cold period immediately after the engine start before the catalysts reach their working temperature will be an especially critical factor in meeting more stringent regulations in the future. In this study, the total hydrocarbon quantities are measured using a Fast FID with gasoline fuel for a 4-cylinde. Sl engine, including Secondary Air Injection (SAI) system. Commercial SAI device's direction is reverse to the exhaust flow. In this study, a swirl flow type SAI system which is positioned between the exhaust manifold and exhaust port, was developed. We compared the swirl type secondary air injection with a commercial secondary air injection of .everse flow. The swirl type SAI showed better results in reducing HC by 26% than the commercial flow type SAI of reverse flow which was caused by the better mixing between the exhaust gas and the secondary air.

합성가스를 첨가한 SI 엔진의 냉간시동 유해 배기가스 저감에 관한 연구 (A Study on Reductions of Cold Start Emissions with Syngas Assist in an SI Engine)

  • 송춘섭;가재금;홍우경;박정권;조용석;김창기
    • 한국자동차공학회논문집
    • /
    • 제19권4호
    • /
    • pp.114-120
    • /
    • 2011
  • Fuel reforming technology for the fuel cell vehicles has been frequently applied to internal combustion engine for the reduction of engine out emissions. Since syngas which is reformed from fossil fuel has hydrogen as a major component, it has abilities to enhance the combustion characteristics with wide flammability and high speed flame propagation. In this paper, syngas was feed to a 2.0 liter SI engine with MPI to improve exhaust emissions under cold start and early state of idle condition. Syngas fraction is varied to 0%, 10%, 25%, with various ignition timings. Exhaust emission characteristics and the exhaust system temperature were measured to investigate the effects of syngas addition on cold start. Result showed that HC emission could be dramatically reduced due to the fact that syngas has $H_2$ and no HC as components. The amount of $NO_x$ emission was decreased with the increase of syngas fraction. Because the dilution effect of $N_2$ and the retard of ignition timing reduces the peak combustion temperature inside the cylinder. Exhaust gas temperature was lower than that of gasoline feeding condition. Retarded ignition timing, however, resulted in increased exhaust gas temperature approximated to gasoline condition. It is supposed that the usage of syngas in an SI engine is an effective solution to meet the future strict emission regulations.

엔진 문전 조건이 촉매 온도에 미치는 영향 (Parametric Study of Engine Operating Conditions Affecting on Catalytic Converter Temperature)

  • 이석환;배충식;이용표;한태식
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.61-69
    • /
    • 2002
  • To meet stringent LEV and ULEV emission standards, a considerable amount of development work was necessary to ensure suitable efficiency and durability of catalyst systems. The main challenge is to cut off the engine cold-start emissions. It is known that up to 80% of the total hydrocarbons(THC) are exhausted within the first five minutes in case of US FTP 75 cycle. Close-Coupled Catalyst(CCC) provides fast light-off temperature by utilizing the energy in the exhaust gas. However, if some malfunction occurred at engine operation and the catalyst temperature exceeds 1050$\^{C}$, the catalytic converter is deactivated and shows the poor conversion efficiency. This paper presents effEcts of engine operating conditions on catalytic converter temperature in a SI engine, which are the indications of catalytic deactivation. Exhaust gas temperature and catalyst temperature were measured as a function of air/fuel ratio, ignition timing and misfire rates. Additionally, light-off time was measured to investigate the effect of operating conditions. It was found that ignition retard and misfire can result in the deactivation of the catalytic converter, which eventually leads the drastic thermal aging of the converter. Significant reduction in light-off time can be achieved with proper control of ignition retard and misfire, which can reduce cold-start HC emissions as well.

흡기포트 분사방식의 가솔린 엔진에서 냉시동시 혼합기 형성에 관한 연구 (A Study on Mixture Preparation in a Port Fuel Injection Sl Engine During Engine Starting)

  • 황승환;이종화;민경덕
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.15-22
    • /
    • 2002
  • As the emission regulations on the automobiles have been increasingly stringent, precise control of air/fuel ration is one of the most important issues on the gasoline engines. Although many researches have been carried out to identify the fuel transport phenomena in the port fuel injection gasolines, mixture preparation in the cylinder has not been fully understood due to the complexity of fuel film behavior, In this paper, the mixture preparation during cold engine start is studied by using a Fast Response Flame ionization Detector.(FRFID) In order to estimate the transportation of injected fuel from the intake port into cylinder, the wall wetting fuel model was used. The two coefficient($\alpha$,$\beta$) of the wall-wetting fuel model was determined from the measured fuel mass that was inducted into the cylinder at the first cycle after injection cut-in. $\alpha$( ratio of directly inducted fuel mass into cylinder from injected fuel mass) and $\beta$ (ratio of indirectly inducted fuel mass into cylinder from wall wetted fuel film on the wall) was increased with increasing cooling water temperature. To reduce a air/fuel ratio fluctuation during cold engine start, the appropriate fuel injection rate was obtained from the wall wetting fuel model. Result of air/fuel ratio control, air/fuel excursion was reduced.

Mechatronic V8 Engine Start Capabilities of an Automotive Starter/Generator System at the Super Cold Weather

  • Jang, Bong-Choon
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.942-949
    • /
    • 2002
  • The use of a combined starter/generator integrated into the drive train of an automobile offers several possibilities for improvement of fuel economy The use of such a starter/generator system is made feasible by a switch from a 14 volts electrical system to a 42 volts system, however, the sizing of the components is not a trivial problem. This study combines a dynamic electromechanical model of the starter, battery and power electronics with the nonlinear mechanics of the piston/crankshaft system and a thermofluid model of the compression and expansion processes to investigate the cold start problem. The example involves the start of an eight cylinder engine at -25 degrees Celsius. This paper shows how the mechatronic V8 engine of an automotive starter/generator system for the startability works well.

한국형발사체 연소기 연소시험설비의 구축 및 시운전 (Construction and Start-up Test of Hot-firing Test Facility for KSLV-II Combustion Chamber)

  • 이광진;이승재;서대반;황창환;우성필;임지혁;전준수;소윤석;김채형;김성혁;김승한;조남경;한영민
    • 한국추진공학회지
    • /
    • 제20권1호
    • /
    • pp.69-75
    • /
    • 2016
  • 본 논문은 한국형발사체 연소기 연소시험설비의 구축과 시운전 결과를 다루고 있다. 이 시험설비는 2012년부터 2014년까지 구축되었고, 2014년 하반기에 시운전이 수행되었다. 시운전 과정에는 산화제 수류시험, 연료 수류시험, 냉각수 수류시험 등이 수행되었고, 이후 점화시험이 이루어졌다. 점화시험 결과는 연소기의 시동시퀀스를 설정하는데 적용되며, 저압연소시험과 설계점 연소시험을 위한 기초자료로 활용되게 된다.

가솔린엔진의 냉시동 천이구간에서 배출가스 온도 및 유해배출물 특성에 관한 연구 (Characteristics of Exhaust Gas Temperature and Harmful Emission During Cold Start Transient Operation in an SI Engine)

  • 조용석;정대철;박영준;김득상
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1181-1187
    • /
    • 2006
  • Stringent regulations of exhaust emission from vehicles become a major issue in automotive industries. In SI engines, it is one of the crucial factor to reduce exhaust emissions during cold start in order to meet stringent regulations such as SULEV or EURO-4, because SI engines emit a large portion of total harmful exhaust compounds when they are cold. At early stages of cold start in gasoline engines, exhaust gas temperature plays a key role to improve three way catalyst by virtue of fast warmup. Therefore, this study focused on the increase of exhaust gas temperature under controls of engine operating parameters such as spark ignition timing, valve overlap by virtue of intake VVT and catalyst heating function. Furthermore, effects on harmful emission due to these parameters are also investigated. Experiments showed that retarded spark ignition timings and increased valve overlap may be helpful to increase exhaust gas temperature. It was also found that $NO_x$ was decreased with increased valve overlap. This study also showed that sudden changes in ISA and amount of fuel due to the deactivation of catalyst heating function cause temporal increase of harmful emissions.