• Title/Summary/Keyword: Cold district

Search Result 63, Processing Time 0.025 seconds

A Study on the District Community Cooling System using LNG Cold Energy (LNG 냉열이용 지역집단 냉방시스템에 대한 연구)

  • Kim, Chung-Kyun;Kim, Seung-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.27-30
    • /
    • 2010
  • This paper presents the system design process of district community cooling system using LNG cold energy. The newly developed LNG cooling system includes several heat exchangers, LNG storage tank, thermal mass storage tank, several cold energy storage tanks, gas air-conditioners, compressors, constant pressure regulators, cold energy and hot energy supply pipes. In addition, the gas air-conditioner system is installed to supply not sufficient cold energy due to low level of city gas consumptions during a summer period. This system design is very effective and safe to supply cold energy mass of fresh air by exchanging two thermal masses of an air and 200kcal/kg cold energy of LNG. The district community cooling system with LNG cold energy does not produce CO2 and freon gases in the air.

A Study on the Integrated Fusion Technology Between a Carbon Dioxide Emission and a District Cooling Energy Using a Cold Energy ($CO_2$ 배출문제와 냉열이용 지역집단 냉방에너지에 관한 통합적 융합기술 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.34-40
    • /
    • 2006
  • This paper provides a fusion technology between a district cooling energy system and an environment conservation policy based on the energy savings and reusable cold energy resources. The district heating and cooling systems are very effective ways for an energy saving, a cost reduction and a safety control. It is necessary to equalize the energy savings and an environmental preservation policy for an improved human lift. A gasification process of a liquefied natural gas, cooling water from deep seawater and an ice water thermal storage system may produce a cold energy. A district cooling system is used to cool an apartment, office buildings and factory facilities with a cooling energy supply pipeline. LNG cooling energy will switch a conventional air-conditioning system, which is operated by on electrical energy and a Freon refrigerant. Coincident with significant clean energy and operating cost savings, LNG cold energy system owen radical reductions in an air-borne pollutant, $CO_2$ and the release of environmentally harmful refrigerants compared with that of the conventional air-conditioning system. This study provides useful information on the fusion technology of a LNG cold energy usage and energy savings, and environmental conservation.

  • PDF

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF

Studies on Zone Cooling of Greenhouse in the Daytime in Summer and Occurrence of Blossom - End Rot in Tomato Plants (하기주간의 국소냉방과 토마토 배꼽썩음병 발생에 관한 연구)

  • 조일환;우영회;인과홍중;교본강
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.36-41
    • /
    • 1994
  • The major objective of this study is to develop a method of zone cooling during summer day using heat pump for year- round cultivation. The efficiency of cold water cooling and fog cooling was investigated. In order to prevent the occurrence of blossom - end rot in tomato, cooling was induced together with air flow of the fruit treatment as well as promoting air circulation in the plant treatment was induced. The following results were obtained : 1) The temperature in the cold water cooling district was 1$0^{\circ}C$ lower than greenhouse temperature and the temperature in the fo8 cooling district was about 5$^{\circ}C$ lower than the greenhouse. 2) Regardless of cooling method, the treatment of air flow on fruit did not affect the fruit but prevent blossom-end rot. There was 34.5% occurrence rate of blossom -end rot in non-air flow district of cold water cooling 54.5% in non-air flow district of fog cooling and 78% in fog circulation cooling district. The cooling efficiency using cold water cooling method induced enough cooling at critical temperature for growth and development and the occurrence of blossom -end rot was lower than fog cooling. Fog cooling in culture district with air circulation did not induce and difference in temperature but caused an Increase in humidity resulting in 24% increase in the occurrence of blossom-end rot. Thus the occurrence of blossom-end rot in tomato caused by environmental factors can be attributed more to humidity than to temperature.

  • PDF

Type 2 Absorption Cycle to Transport Energy in the Long Distance for District Cooling Application (지역냉방 적용을 위한 LNG냉열 장거리 수송용 제 2종 흡수식 시스템)

  • Cho Young Kyong;Kim Jin-Kyeong;Oh Min Kyu;Kang Yong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.250-255
    • /
    • 2005
  • The objective of this paper is to develop a new energy transport system for district cooling application by using type 2 absorption cycle. Cold energy from the LNG storage system is utilized as the cooling source of the condenser and the rectifier. The pressures of the system, UAs of the evaporator and the desorber, and the inlet temperatures of the refrigerant to each component are considered as the key parameters. The results show that UA of the evaporator is more dominant parameter on COP than that of the desorber and the optimum system pressure for the demand side is estimated as 525 kPa. For the present system, it is recommended that the refrigerant inlet temperature of the evaporator be lower than $4.3^{\circ}C$ for long-distance transportation. It is concluded that the cold energy from the LNG storage system can be effectively applied to the long-distance transportation system for district cooling application with the type 2 absorption cycle. The optimum operation conditions are also predicted from the parametric analysis.

A Study on Microclimate Change Via Time Series Analysis of Satellite Images -Centered on Dalseo District, Daegu City- (위성영상의 시계열 분석을 통한 미기후변화 분석 -대구시 달서구를 대상으로-)

  • Baek, Sang-Hun;Jung, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.34-43
    • /
    • 2009
  • Based on previous research on ways of reducing an urban heat island phenomenon via an introduction of wind corridors, I conducted this study to see what influence a change in land cover arising of or going through urbanization has on wind corridors of urban space. As a target place, I chose Daegu city where is a representative extreme heat place in Korea and has been also largely expanded in size by incorporating its neighboring areas since the 1980s, expecially Dalseo District whose surface temperature gap is large. The population of Dalseo District has been sharply increased since its creation as a new administrative district in 1988. I studied on the urban microclimate change for a 20-year period by using satellite images on summer months in 1987, 1997 and 2007 in time frames. The finding of this study found that a reduction of natural land cover and an increase of artificial land cover serves as a disadvantageous factor for cold air creation and flowing and strikingly lowers the amount and height of cold air in the downtown area. It seemed that the cold air creation and flowing functions are influenced by land cover. In order to steadily create cold air and secure its flowing, it is thought that urban development or urban regeneration should be implemented by analysing the characteristics of the space surrounding the city. By doing so, a pleasant and healthy city could be formed.

  • PDF

Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger (급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구)

  • Jeong, Dong-Hwa;Kim, Joo-Wan;Baik, Young-Jin;Lee, Young-Soo;Chung, Dae-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

An Analysis of Consumption Patterns in Residential Sector of District Heating (지역난방의 주택용 열소비행태 분석)

  • Kim, Jin Hyung
    • Environmental and Resource Economics Review
    • /
    • v.10 no.2
    • /
    • pp.217-234
    • /
    • 2001
  • The use of district heating is expanding very rapidly in Korea. High population densities and the relatively cold winters make district heating an economically attractive option. About 8 percent of Korean houses are already using district heating and the government is seeking to aggressively expand this number. It has set a target of 15 percent of the residential heat market to be met by district heating in the year 2001. The main purpose of this paper is to analyze the consumption behavior of households using district heating. By pooling time-series and cross-sectional data for 12 apartment complexes in Seoul area, a single demand function is estimated and used to forecast the amounts of heat demanded by the individual households. The results shows that the level of consumption varies among households, depending on the non-economic factors such as the installation of individual metering equipment and the volume of apartment building. When individual metering equipment is installed, the level of annual heat consumption per household declines, on average, about 22.1 Mcal per square meters, which is equivalent to 834 won per square meter in terms of heating expenditures. In case that the apartment building was built in more than 6 stories, annual consumption level reduces additionally about 17.3 Mcal per square meters and, thus, save the expenditures by 649 Won per square meters, compared to the opposite case.

  • PDF