• Title/Summary/Keyword: Cold Water

Search Result 1,908, Processing Time 0.029 seconds

Activity and Isozyme Profile of Antioxidative Enzymes at Booting Stage of Rice Treated with Cold Water

  • Kim Ki-Young;Kim Bo-Kyeong;Shin Mun-Sik;Choung Jin-Il;Ko Jae-Kweon;Kim Jung-Kon;Lim Jung-Hyun;Yun Song-Joon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.4
    • /
    • pp.289-294
    • /
    • 2004
  • This study was carried out to investigate the antioxidative enzymes and isozymes between chilling-tolerant and -susceptible varieties at the booting stage under cold water stress $(13^{\circ}C)$ in japonica rice. Total SOD, CAT, POX, and GR activities on the basis of protein were found to be important factors to defend cold water stress. Especially, SOD and CAT activities showed distinctive differences between chilling-tolerant and -susceptible varieties. Chilling-tolerant varieties were higher than chilling-susceptible varieties for SOD and CAT activities. One of eight isozyme bands for SOD was a inducible isoform. Three isozymes for CAT and one isozyme for POX were closely correlated with defense to cold water stress. Total GR activities except Stejaree 45 on the basis fresh weight and POX were increased by cold water stress, but there was no difference between chilling-tolerant and -sus­ceptible varieties.

Characteristics and origin of the Cold Water in the South Sea of Korea in Summer (여름철 남해 저온수의 특성과 기원)

  • Cho, Yang-Ki;Kim, Kuh
    • 한국해양학회지
    • /
    • v.29 no.4
    • /
    • pp.414-421
    • /
    • 1994
  • In summer, the water colder than 14$^{\circ}C$ exists near the bottom in the South Sea of Korea. We investigate the characteristics and the origin of this bottom cold water by the analysis of temperature and salinity data. The salinity of the bottom cold water in June and August is 33.4∼34.0% which is lower by about 0.6% than that of cold water in April. In 1983, the water in August is colder than in June. These facts indicate that the bottom cold water in summer is not the same one formed in the South Sea in winter, but flowed into the area from the neighbouring seas. Based upon frequency distribution of the occurrence of the cold water and temperature and salinity analysis of waters in the Cheju Strait, it is suggested that the origin of the bottom cold water is west of the Cheju Strait.

  • PDF

Water Mass Distribution and Currents in the Vicinity of the Hupo Bank in Summer 2010 (2010년 하계 후포퇴 근해의 수괴분포와 해류)

  • Lee, Jae Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.1
    • /
    • pp.61-73
    • /
    • 2016
  • Water mass distribution and currents were investigated off the east coast of Korea near the Hupo Bank using the CTD and ADCP data from June to August 2010. The typical water masses were: (1) Tsushima Surface Water (TSW) from the East Korean Warm Current (EKWC) in the surface layer, (2) a shallow thermocline at 20-30 m depth, (3) Tsushima Middle Water (TMW) of high salinity (>34.2) below the pycnocline, (4) North Korean Cold Water (NKCW) of low salinity (<34.05) and low temperature (<4°C) in the lower layer. In June, a double eddy was observed in which a cold filament intruded cyclonically from the south around a pre-existing cold-core eddy. A burst of strong southward current was recorded in mid-August due to a warm filament from the meandering EKWC. Current in the N-S direction was predominant due to topographic effects, and the direction of the northward EKWC was frequently reversed in its direction due to the eddy-filament activity, whereas the influence of the wind was not noticeable. The vertical structure of the current was of a two-layer system, with the northward EKWC in the upper layer and weak southward flows corresponding to the North Korean Cold Current (NKCC) in the deeper layer.

Inheritance of Days to Heading, Spikelet Number and Fertility under Cold Water Treatment in Rice (냉수처리답에서 벼의 출수일수, 영화수 및 임실률의 유전)

  • 예종두
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.1
    • /
    • pp.45-52
    • /
    • 1996
  • This study was conducted to know how cold tolerance of rice is inherited. Several crosses were made between cold tolerant and susceptible varieties, and their progenies were evaluated for days to heading, spikelet number per panicle and spikelet fertility under both cold water and natural conditions. In F$_1$ and F$_2$ generations, earlier heading, more number of spikelet per panicle and higher spikelet fertility under the cold condition were dominance, and less delay or reduction in heading days and spikelets per panicle by cold treatment were over dominance or partial dominance, while less reduction in spikelet fertility by cold-water irrigation was complete dominance. Heritability in most characters by cold treatment was high and there was less difference of heritabilities in heading days and spikelets per panicle between cold treatment and natural conditions, while there was much difference of heritability in spikelet fertility between two conditions. Heterosis in spikelet fertility was considerably high, while those in heading days and spikelets per panicle were relatively low. Heterosis in remote crosses was especially larger under the cold-water treatment condition compare with that under natural condition.

  • PDF

A Case Study on Cold Water Damage to Rice by Installation of Underground Drain Pipe at a Mountainous Valley (산간 계곡의 지하배수관 설치에 따른 벼 냉수피해 사례분석)

  • Shim, Kyo-Moon;Jung, Myung-Pyo;Kim, Yong-Seok;Choi, In-Tae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.270-274
    • /
    • 2015
  • The complaint was filed for the cold water damage to rice in accordance with the installation of buried drain pipes in the mountainous areas of the valley. Field research was conducted in order to identify and analyze relevance of cold water damage to rice with underground drain pipe installation. In conclusion, water temperature was analyzed by 0.5 to $4.5^{\circ}C$ lower than before the installation of underground drain pipes, so the cold water damage to rice was likely to occur at the rice paddy field using cold water passing through the underground drain pipe. Therefore, the rice harvest was estimated to be impossible without appropriate measures of water temperature rise such as use of small unshaded warming basins, before water is applied to fields.

Quality Characteristics of Extracted Coffee with Cold Water according to Water Quantity and Dilution Ratio (가수량 및 희석 비율을 달리하여 제조한 냉수 추출 커피의 품질 특성)

  • Jeong, Ji-Gyun;Cho, Yeon-Sook;Kwak, Eun-Jung
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.24 no.1
    • /
    • pp.109-115
    • /
    • 2014
  • This paper investigated the optimal conditions for coffee extraction and dilution by comparing differences in soluble compounds and sensory characteristics of coffee subjected to cold-water extraction according to water quantity and dilution ratio. For sample preparation, we extracted coffee for 3 to 10 hours by adding 400 mL, 600 mL, 1,000 mL and 1,800 mL of cold water ($20^{\circ}C$) to 100 g of ground coffee, resulting in 200 mL, 400 mL, 800 mL and 1,600 mL portions of extracted coffee, respectively. Following this, the 200 mL, 400 mL and 800 mL portions of extracted coffee were further diluted with 1,400 mL, 1,200 mL and 800 mL of cold water, resulting in ratios of coffee to cold water of 1:7, 1:3 and 1:1, respectively. The 1,600 mL of portion of extracted coffee was not diluted and used as a sample. Undiluted coffee showed the highest values for pH, acidity, reducing sugar, total soluble solids and total phenolic compounds among all sample coffees, whereas the highly diluted coffee with a high ratio of 1:7 showed the lowest values. In a descriptive test, odor, sourness, bitterness and body intensity were also the highest in undiluted coffee due to the overly extracted coffee compounds. Undiluted coffee showed the lowest preference in terms of aroma, aftertaste and balanced coffee taste. On the other hand, diluted coffee at a ratio of 1:7 showed the lowest values for odor, sourness, bitterness and body intensity. Diluted coffee at a ratio of 1:3 showed the highest values for sweetness and acidity and was the most preferred in terms of aroma, aftertaste and balance. As a result, our study concluded that the optimal conditions for extraction and dilution of coffee with cold water are a ratio of ground coffee to cold water of 1:6 (w/v), followed by further dilution of the coffee by cold water at a ratio of 1:3.

Recent Advances in Cold-Start and Drive Capability of Fuel Cell Electric Vehicle

  • Sung, Woo-Suk;Suh, Kyung-Won;Kweon, Soon-Gil;Park, Jong-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.47-50
    • /
    • 2008
  • The sub-zero cold is a major environmental consideration for the operational readiness of FCEVs because fuel cells produce water and utilize wet air with varying water content to generate electricity. Typical fuel cells thus have a fatal flaw in freezing conditions at startup. This drawback becomes more serious with the outsourced fuel cell that is entirely water-based for its internal humidification. In this background, the HMC's self-designed fuel cell was developed as an alternative and was employed in the Tucson-based FCEV in 2006 demonstrating its good cold-startup characteristics. The cold-startup capacity of the vehicle was validated through tests in the cold chamber and on the road, resulting in 50% stack power achieved in 250 seconds at $-15^{\circ}C$.

  • PDF

Variation and Structure of the Cold Water Around Ganjeol Point Off the Southeast Coast of Korea (하계 용승현상에 따른 간절곶 주변해역의 냉수역 구조와 변동)

  • Choo, Hyo-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.836-845
    • /
    • 2016
  • The variation and structure of the cold water mass around Ganjeol Point during the summer of 2011 were studied using data from CTD observations and temperature monitoring buoys deployed at 20 stations off the southeast coast of Korea. There was a $-12^{\circ}C$ surface temperature difference between the cold water mass and normal water during the monitoring period. Variations in the isothermal lines for surface temperature along the coast showed that the seabed topography at Ganjeol Point played an important part in the distribution of water temperature. Cold water appeared when the wind components running parallel to the coast had positive values. The upwelling -response for temperature fluctuations was very sensitive to changes in wind direction. Vertical turbulent mixing due to the seabed topography at Ganjeol Point can reinforce the upwelling of cold bottom water. From wavelet analysis, coherent periods found to be 2-8 days during frequent upwelling events and phase differences for a decrease in water temperature with a SSW wind were 12-36 hours.

Numerical Analysis on the Thermal Design of a Heat Exchanger for a Cold & Hot Water Mattress Equipped with Thermoelectric Modules (열전소자가 적용된 냉·온수 매트용 전열 모듈의 기초 열설계에 관한 수치해석적 연구)

  • Yang, Ho-Dong;Park, Seul-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.113-121
    • /
    • 2021
  • In this study, the thermal characteristics of cold and hot water mattress units equipped with thermoelectric modules were investigated via numerical analyses. Cold and hot water mattress products that are currently in existence use manual methods requiring refrigerants to be added to the hot water boiler. However, the cold and hot water mattress units using thermoelectric modules can provide improved efficiency via energy savings and actively resolving environmental pollution problems. To determine the efficiency of the thermoelectric module, the mattress was modeled and its efficiency was analyzed for the cooling and heating processes using two 100-W-class and one 200-W-class thermoelectric modules, respectively. From the results of this study, it was confirmed that when two 100-W-class modules were used, the application area was larger than when a single 200-W-class module was used, with uniform temperature distribution and improved performance compared to existing products in terms of electrical energy.

Inheritance of Some Agronomic Characters Related to Cold Tolerance under Cold Water Treatment in Rice (냉수처리답에서 벼 내냉성 관련형질의 유전)

  • 예종두
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.4
    • /
    • pp.473-480
    • /
    • 1995
  • This study was conducted to know how cold tolerance of rice varieties is inherited. Several crosses were made between cold tolerant varieties and susceptible varieties, and their progenies were morphologically and physiologically evaluated each characters at cold water and natural conditions. The segregation modes of leaf discoloration by cold treatment in F$_2$ generations are agreed to simple inheritance ratio of R3 : Sl in four crosses among total seven cross combinations. In F$_1$ and F$_2$ generations, tall one was dominance in culm and panicle length and less reduction in culm and panicle length by cold treatment was overdominance or partial dominance, while more number of panicles per plant was dominance and more increasing of panicle numbers by cold water irrigation was overdominance. Heritability and heterosis in most characters showed high values, and heterosis in remote crosses was especially larger under the cold water treatment condition compare with that under natural condition.

  • PDF