• 제목/요약/키워드: Cold Gas

검색결과 760건 처리시간 0.033초

헬륨을 이용한 열유속센서 검정방법의 실험적 연구 (An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas)

  • 양훈철;송철화;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

마이크로 콜드 가스 추력기의 선행 연구 (Preliminary Study of Micro Cold Gas Thruster)

  • Seonghwan Moon;Hwayoung Oh;Hwanil Huh
    • 한국추진공학회지
    • /
    • 제8권2호
    • /
    • pp.54-61
    • /
    • 2004
  • 추진 시스템을 포함해 구성요소의 소형화가 최근 위성체 기술의 경향이다. 소형위성 추진기관은 크기 축소라는 기술적 도전일 뿐만 아니라, 기본적인 유동/연소 구속조건의 결합을 보이고 있다. 본 논문에서는 냉각 가스 마이크로 추력기에서 마이크로 노즐의 물리적 구속조건에 대해 살펴보았다. 또한 미소 추력의 측정 방법에 대해서도 언급하였다.

분류층 건식 석탄가스화기에서의 가스화 특성 (Gasification characteristics in an entrained flow coal gasifier)

  • 유영돈;윤용승;안달홍;박호영
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1690-1700
    • /
    • 1997
  • Entrained coal gasification tests with Datong coal were performed to assess the influence of oxygen/coal ration and pressure. When gasification condition in oxygen/coal ratio has changed from 0.5 to 1.0, optimal gasification condition from low pressure runs was oxygen/coal ratio of approximately 0.9 where CO was produced about 40% and H, about 20%. Under the pressure condition of 12-14 atmospheres, optimal oxygen/coal ratio value was in the region of 0.6 where CO was produced about 55% and H2about 25%. From these results, it was found that the oxygen/ coal ratio for the maximum production of CO and H, was decreasing with the increase in gasifier pressure and also, with increasing oxygen content, carbon conversion was increased. For the Chinese Datong coal, cold gas efficiency was in the range of 40-80%.

이중관 배기메니폴드의 HC저감효과 및 열특성에 관한 연구 (A Study on the Reduction of HC and Heat Characteristics of the Dual Pipe Exhaust Manifold)

  • 박경석;허형석
    • 한국자동차공학회논문집
    • /
    • 제9권6호
    • /
    • pp.103-111
    • /
    • 2001
  • During cold-start period, the reduction of exhaust emissions is a challenging task. To decrease harmful gaseous substances such as HC, it is necessary to realize a fast catalyst warm-up. In this study, the performance of dual pipe exhaust system have been carried out through different test mode. From measurement of gas temperature and HC concentration, the following conclusions were derived ; 1) Compared with single pipe, dual pipe exhaust system remarkably increase temperature of exhaust gas going through M.C.C(Main Catalytic Converter). 2) W.C.C.(Warm-up Catalytic Converter) also decreases HC emission. To reduce HC emission, it is helpful to use W.C.C. as well as dual pipe exhaust system. 3) Using finite element method, it is shown that inner parts have much higher distribution of temperature than outer parts.

  • PDF

LNG 냉열을 이용하는 동력사이클 열역학 해석 (Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy)

  • 최권일;장홍일
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF

LNG운반선의 증발기체 재액화 장치의 사이클 해석

  • 진영욱
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2012년 춘계학술대회
    • /
    • pp.221-232
    • /
    • 2012
  • Cycle analysis has been performed to find out the optimum design point of the BOG re-liquefaction plant. The cycle state, defined by three cycle variables, was mainly described by the three cold temperatures of the three-pass heat exchanger, on which the constraints by the heat exchanger are imposed. The cycle states which are confined within a domain limited by the temperature constraints were the primary issue of this study. The BOG mass within the domain was analyzed first and then the cycle performance was related to the BOG mass afterwards, which enabled us to explain the observed behavior of the cycle performance under the temperature constraints by the heat exchanger. A good cycle performance could be ensured if the two cold Nitrogen temperatures of the three temperatures were placed close together near $-140^{\circ}C$ while the BOG temperature is kept far above enough, but not too far, from $-140^{\circ}C$ such that it does not interfere in their optimum temperature range.

  • PDF

헬륨을 냉매로 사용한 1/2파장 열음향 냉동기의 실험 및 성능평가 (The construction and performance Investigation of 1/2 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant)

  • 최두원;김동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.471-476
    • /
    • 2006
  • Thermoacoustic refrigerators are operated with acoustic power to pump heat. The acoustic standing wave displaces the gas In the channels of the stack while compressing and expanding. The thermal interaction between the osillating gas he surface of the stack generates an acoustic heat pumping. in this study, a thermoacoustic refrigerator is composed of a resonator of 4cm diameter, stack of plates, heat exchangers and cooling part. Length of the hot heat exchangers, the stack of plates and the cold heat exchanger are 9mm, 8mm and 6mm respectively. Using helium as a coolant at frequency of 516Hz, the cold-part temperature of exchanger fell to $-19.0^{\circ}C$ after 1hours.

  • PDF

LNG운반선의 화물 누출 시 함침된 고분자 폼의 기계적 성능에 관한 연구 (A study on the mechanical performance of impregnated polymer foam in cargo leakage of LNG carrier)

  • 박기범;김태욱;김슬기;이제명
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권4호
    • /
    • pp.345-352
    • /
    • 2017
  • 본 연구에서는 액화천연가스(Liquefied natural gas, LNG) 운반선 화물창 손상으로 인한 극저온 LNG 누출 및 하중 작용 시 화물창의 초저온 보냉재를 구성하고 있는 고분자 폼(Polymer foam) 소재의 성능을 관찰하고자 하였다. LNG와 맞닿아 있는 LNG 운반선 1차 방벽은 유체 충격하중이나 오랜 시간 동안의 LNG 적재/하역으로 인해 손상이 누적 되면 누출로 이어지게 된다. 극저온 유체의 누출은 다공성 밀폐 셀 구조인 고분자 폼 내부에 영향을 끼쳐 작용 하중에 대한 거동변화를 야기한다. 본 연구에서는 단열재(Insulation)로 사용되는 고분자 소재인 폴리이소시아누레이트 폼(Polyisocyanurate foam, PIF) 시험편의 기계적 성능에 대한 평가를 수행하였다. 시험편에 극저온 액체를 함침시켜 압축실험을 진행함으로써 저온 취성(Cold brittleness)으로 인한 성능 변화와 함께 극저온 유체의 함침 영향에 대해 정량적으로 비교분석 하였다.

초음속 2차원 2단 혼합층에서 중간층의 역할 (A Study on the Effect of Mid Layer on Supersonic 2D Double Shear Layer)

  • 김동민;백승욱
    • 한국추진공학회지
    • /
    • 제19권1호
    • /
    • pp.9-17
    • /
    • 2015
  • 기본 유동 형상은 상대적으로 얇은 중간층이 연료와 공기 사이에 끼어있는 평행 2단 혼합층으로 구성되어 있다. 본 연구는 중간층의 두께 변화에 따른 연소 향상을 수치해석을 통해 조사하였다. 이 경우에, 난류 혼합층에서 열 방출에 의한 효과가 중요하다. 수치해석을 수행하기 위해 완전 보존적인 비정상 2차 시간 정확도의 하부 반복 기법과 2차 총 변화 억제 기법을 k-${\omega}$ 전단응력이동 모델이 결합된 유한체적법과 함께 사용하였다. 다음과 같이 3개의 경우에 대해 해석을 수행하였다. 연료와 공기로 구성된 단일 혼합층, 연료와 공기 사이에 불활성 기체층이 끼어있는 2단 혼합층, 그리고 연료와 공기 사이에 차가운 연료층이 끼어있는 2단 혼합층. 수치해석은 중간 기체층이 1, 2, 4 mm 인 경우에 대하여 수행되었다. 기체층의 총 두께는 4 cm이다. 불활성기체층이 2, 4 mm인 경우와 저온의 연료층이 4 mm인 경우에 단일 혼합층의 경우보다 연소영역이 확대된다.

Cold Flow Simulation of $SF_{6}$ Puffer Circuit Breaker

  • Bae, Chae-Yoon;Jung, Hyun-Kyo;Shin, Sang-In;Park, Oh-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.121-128
    • /
    • 2001
  • Numerical schemes for the simulation of the cold gas flow in the SF6 puffer type circuit breaker is presented. The governing equation is axisymmetric compressible Euler Equation and FVM is used to analyze the behavior of flow. The upwind scheme is used to avoid numerical instability and MUSCL is used to obtain high order accuracy. For the efficient calculation, AF-ADI scheme is used. The simulation result shows good agreement with the experimental data.

  • PDF