• 제목/요약/키워드: Coiled tube

검색결과 41건 처리시간 0.031초

Development of a computer code for thermal-hydraulic design and analysis of helically coiled tube once-through steam generator

  • Zhang, Yaoli;Wang, Duo;Lin, Jianshu;Hao, Junwei
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1388-1395
    • /
    • 2017
  • The Helically coiled tube Once-Through Steam Generator (H-OTSG) is a key piece of equipment for compact small reactors. The present study developed and verified a thermal-hydraulic design and performance analysis computer code for a countercurrent H-OTSG installed in a small pressurized water reactor. The H-OTSG is represented by one characteristic tube in the model. The secondary side of the H-OTSG is divided into single-phase liquid region, nucleate boiling region, postdryout region, and single-phase vapor region. Different heat transfer correlations and pressure drop correlations are reviewed and applied. To benchmark the developed physical models and the computer code, H-OTSGs developed in Marine Reactor X and System-integrated Modular Advanced ReacTor are simulated by the code, and the results are compared with the design data. The overall characteristics of heat transfer area, temperature distributions, and pressure drops calculated by the code showed general agreement with the published data. The thermal-hydraulic characteristics of a typical countercurrent H-OTSG are analyzed. It is demonstrated that the code can be utilized for design and performance analysis of an H-OTSG.

극세관 헬리컬 코일형 열교환기에 관한 연구 (A Study on the Helically Coiled Heat Exchanger of Small Diameter Tubes)

  • 김주원;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1492-1499
    • /
    • 2001
  • In order to develop the compact and flexible heat exchangers, we made the helically coiled heat exchangers. They can be manufactured with small diameter copper tubes without the need for fins; inner diameter=1.0 mm, straight tube length=1.5 m. The experiments were carried out with the following conditions; evaporation pressure=0.6 MPa, air velocity=0.7 ∼ 1.7 m/s, and working fluid=R-22. Pressure drop and heat transfer coefficient of heat exchangers were experimented according to the air velocity. The results of heat transfer coefficient show a 35% beneficial increase fur these heat exchangers over the other covered fin-tube heat exchangers. A cooling capacity of about 3 kW was obtained with an air velocity of 1.5 m/s. The distribution header has also been designed fur efficient distribution of refrigerant flow.

Fluidelastic instability of a curved tube array in single phase cross flow

  • Kang-Hee Lee;Heung-Seok Kang;Du-Ho Hong;Jong-In Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1118-1124
    • /
    • 2023
  • Experimental study on the fluidelastic instability (FEI) of a curved tube bundle in single phase downward cross flow is investigated for the design qualification and analysis input preparation of helical coiled steam generator tubing. A 6×9 normal square curved tube array with equal and different vertical/horizontal pitch-to-diameter ratio was under-tested up to 6 m/s in term of gap flow velocity to measure the critical velocity for FEI. The critical velocity for FEI was measured at the turning point from the vibration amplitude plot along the gap flow velocity. Our test results were compared with straight tube results and published data in the design guideline. The applicability of the current design guidelines to a curved tube bundle is also assessed. We found that introducing frequency difference in a curved tube array increases the critical velocity for fluidelastic instability.

열교환기의 나선형 관내 난류유동 수치해석 (Numerical analysis of turbulent flows in the helically coiled pipes of heat transfer)

  • 곽승현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.905-910
    • /
    • 2013
  • 열교환기의 나선형 튜브에 난류모형을 적용하여 유동해석을 수행하였다. 난류모형은 Spalart-Allmaras과 k-${\varepsilon}$이고 시뮬레이션에는 정렬격자를 적용하였다. 레이놀즈 수 영향을 규명하기 위하여 Navier-Stokes 방정식을 풀어 속도벡터, 압력, 잔차, 마찰계수를 재연하였다. 나선형튜브는 원심력을 증가하여 튜브의 바깥부분에 벽전단 응력을 크게 하였다. 열전도율과 마찰저항의 증가는 곡률에 기인하며 튜브의 내부방향으로는 벽 전단응력이 감소했다. 원심력은 유체의 에너지를 증가시켜서 바깥쪽으로 열전도율을 증가시켰고 이는 내부유동의 압력강하 및 관마찰계수가 상호 밀접한 관계가 있음을 규명하여 주었다. 본 수치결과는 검증을 위하여 타 계산에서 얻어진 마찰계수 결과와 비교하였다.

곡률비가 다양한 코일 튜브에서의 열전달현상에 관한 연구 (A Study on the Heat Transfer Phenomena in Coiled Tubes with Variable Curvature Ratios)

  • 한규일;박종운
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1509-1520
    • /
    • 1998
  • An experiment was carried out for the fully developed turbulent flow of water in tube coils on the condition of uniform heat flux. The present work was conducted for various ranges for Dean number(1794~1321), Prandtl number (2.5~4.5), curvature ratio parameters (22~60). Heat transfer to steady viscous flow in coiled tubes of circular cross section was studied for fully developed velocity and temperature fields under the thermal boundary condition of uniform heat flux. The peripherally local Nusselt number correlated as a function of Dean and Prandtl numbers. We studied the flow in heat coiled tubes under the influence of both centrifugal and buoyancy forces in order to gain insight into the flow pattern. In the present study, we obtained three emperical formulas, $Nu_v=0.0231Re^{0.84}Pr^{0.4}(a/R)^{0.13}$ (vertical) $Nu_c=0.0241Re^{0.86}Pr^{0.4}(a/R)^{0.08}$ (corrugated) $Nu_h=0.0227Re^{0.84}Pr^{0.4}(a/R)^{0.09}$ (horizontal).

CFC11, CFC12, HCFC22 대체냉매의 응축 열전달계수 (Condensation heat transfer coefficients of alternative refrigerants for CFC11, CFC12 and HCFC22)

  • 정동수
    • 대한설비공학회지:설비저널
    • /
    • 제28권5호
    • /
    • pp.389-395
    • /
    • 1999
  • 냉동공조설비, 발전설비, 화학플랜트설비 등에 사용되는 응축기는 주로 증기가 관의 외부에서 응축을 하고 냉각수가 관 내부로 흐르는 쉘-튜브(shell and tube)형 태를 취하고 있다. 초기투자비용 및 운전비용을 줄이기 위해서는 응축기의 열교환 성능을 향상시키는 일이 필수적이며 이를 위해 코팅 표면(coated surfaces), 거친 표면(rough surfaces), 코일 튜브(coiled tubes), 선회 흐름장치(swirl flow), 전열면적을 넓힌 낮은 핀관과 3차원 형상을 갖는 열전달 촉진관의 사용이 제시되고 있다.

  • PDF

Development and application of the helically coiled once-through steam generator module for dynamic simulation of nuclear hybrid energy system

  • Keon Yeop Kim;Young Suk Bang
    • Nuclear Engineering and Technology
    • /
    • 제56권8호
    • /
    • pp.3315-3329
    • /
    • 2024
  • Small Modular Reactors (SMRs) adopt the Helically Coiled Once-Through Steam Generators (OTSG) extensively for its compactness and higher heat transfer efficiency. As a heat exchanger between the primary side (reactor coolant system) and the secondary side (feedwater and steam system) of nuclear steam supply system, the inlet/outlet conditions both of shell side and tube side of OTSGs have significant impacts on overall system response. Considering the flexible operation of SMRs and heat application by extracting steam, a simulation tool for accurate prediction of the OTSG dynamic behaviors would be required for optimizing design and control. In this study, the OTSG dynamic simulation model has been developed. Mathematical governing equation has been derived by using moving boundary approach and a simulation module has been developed by using Modelica Language. The developed module has been compared with publicly available experimental results and benchmarked with MARS-KS calculation results. Also, it has been incorporated into the integrated SMR model (i.e., reactor core, primary side, secondary side) and dynamic behaviors with reactivity feedback and heat balancing have been investigated. In both of steady-state and transient conditions, it shows the promising accuracy.

이중 기관식도루 1예 (Double Tracheoesophageal Fistula)

  • 허영수;이희섭;김근우
    • Advances in pediatric surgery
    • /
    • 제2권1호
    • /
    • pp.68-71
    • /
    • 1996
  • Esophageal atresia(EA) with a double tracheoesophageal fistula(TEF) is rare. It accounts for only 0.7% of all cases of EA and TEF. A male newborn weighing 2860g was born by normal vaginal delivery at 41 weeks' gestation to a 27-year-old mother who had a normal pregnancy. But immediately developed recurrent choking and respiratory distress. Feeding tube was inserted and chest X ray showed the feeding tube coiled in the proximal pouch(T-2 level). With a preoperative diagnosis of EA and distal TEF, the thoracotomy was performed on the third day of life. At thoracotomy, TEF was proved to be a double fistula. Both fistulas were divided and an esophageal anastomosis was performed. The postoperative course was uncomplicated until the eighth postoperative day when a minor anastomotic leak. The patient was discharged at 103 days of age.

  • PDF

탄소섬유전극을 이용한 흐름형 전기분해조 제작 및 유기염료의 전기화학적 분해 연구 (Fabrication of Flow Cell Using Carbon Fiber and Electrochemical Decomposition Characteristics for Organic Dyes)

  • 박덕수
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1371-1377
    • /
    • 2012
  • The simulated dyes solution containing Basic Red 46(BR 46), Yellow 21(Y 21), and Maxilon Blue 30(MB 30) were electrochemically oxidized using carbon fiber as an anode. The electrolyses were performed in a electrolytic flow cell constructed by Vycor glass tube. The carbon fiber was positioned in the inside of Vycor glass tube and platinum wire coiled around outside of tube as a cathode. Several operating variables, such as current, time, pH and flow rate of solution were studied. Increasing current density would lead to a corresponding increase in the dye removal efficiency 99.2 % at a 200 mA. The electrolyses time could also improve and removal efficiency was about 99 % after 1.5 hours of electrolyses. The removal efficiency was increased with the increase of flow rate of solution and optimum flow rate was 5 mL/min. THe pHs of solution affect the removal efficiency. The removal efficiency was decreased with the increase of pH of solution and optimum pH was 5.05 (0.1 M $KNO_3$).