• 제목/요약/키워드: Coil tube

검색결과 156건 처리시간 0.025초

고화질소 냉각형 고온초전도마그네트 개발(I) (Development of HTS magnet cooled by solid nitrogen(I))

  • 오상수;하홍수;하동우;권영길;류강식;이해근;;한일용
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.19-21
    • /
    • 2000
  • We are developing portable type HTS magnet system cooled by solid nitrogen. This system have recooling and recharging capabilities. In this paper, we report preliminary test results obtained from the experimental solid nitrogen system and pancake magnet would with Bi-2223/Ag tapes, respectively. The operation period was sensitively dependent on the vacuum rate n the cryostat, size of SUS tube for flowing N_{2}$, and liquid nitrogen to cool the cryostat. The fabricated coil I_{c}$was 75 A at 20 K in self field.

  • PDF

액화질소 초저온과 이원냉동 초저온 냉열의 비교 실험적 연구 (A Study on the Cold Energy for Liquefied Nitrogen Gas and Cascade Refrigeration System)

  • 김철수;장현순;정효민;정한식
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.56-62
    • /
    • 2007
  • This paper represents the cold energy for liquefied nitrogen gas and cascade refrigerator. In this study, the vaporizer of liquefied nitrogen gas has the fin coil tube type with the dimension of inside diameter of 10mm and outside diameter of 12mm. Also, the total length of vaporizer is 20,000mm. The main experimental parameters are the mean velocity in duct and the supplied flow-rates of liquefied nitrogen gas. For the cascade refrigeration system, the refrigerants are ethane(R 170) in the high pressure stage and R 22 in the low pressure stage.

  • PDF

Design and Simulation of Heating Rubber Roller for Laminating Process

  • Hur, Shin;Woo, Chang Su
    • Elastomers and Composites
    • /
    • 제51권4호
    • /
    • pp.280-285
    • /
    • 2016
  • The purpose of this study is to get optimum design and operation conditions of the heating rubber roller for laminating process. The cause of performance degradation of heating rubber roller is delamination of rubber on metal tube, rubber aging due to high temperature. We measured the material properties of thermal expansion, thermal conductivity, specific heat and density and analyzed thermal distributions of rubber layer using finite element method. As a result of heat/flow analysis, the density distribution of heating coil must shorten the stabilization time by reducing the temperature deviation on the length direction at the temperature rising section after increasing the density of the area contacting with the laminate film at the center part which is an opposite of the current composition while enabling to maintain the temperature of heater to be consistent while maintaining the temperature deviation to be low when heat loss is created. Finally, we determined optimum heating method of heating rubber roller.

탁주의 저온 살균조건에 관한 연구 (Studies on the Pasteurization Conditions of Takju)

  • 이철호;태원택;김기명;이현덕
    • 한국식품과학회지
    • /
    • 제23권1호
    • /
    • pp.44-51
    • /
    • 1991
  • 탁주의 저장성에 영향을 미치는 미생물의 열저항성을 측정하고 이들 미생물에 대한 상업적 살균조건을 수립하였다. 대부분의 탁주내 세균 영양세포 $60^{\circ}C$의 가열에서 파괴되었으며 생잔 포자형성균은 저장기간 중 거의 증식되지 않았다. 따라서 탁주의 저장 중 품질저하를 일으키는 미생물의 효모와 곰팡이류로 판단되었다. 정치형 cap-tube 가열에서 효모의 D-value는 $65^{\circ}C$에서 3.5분, $80^{\circ}C$에서 0.46분이었으며 곰팡이는 $65^{\circ}C$에서 2.7분. $80^{\circ}C$에서는 0.25분이었다. 그러나 연속식 coil형 열교환기를 사용할 경우 효모의 D-value는 $65^{\circ}C$에서 7.1초, $80^{\circ}C$에서 2.3초로, 곰팡이의 경우 $65^{\circ}C$에서 3초, $80^{\circ}C$에서 1초 이하로 크게 낮아졌다. 연속식 코일형 열교환기에서 $65^{\circ}C$ 이상의 온도에서 17초간 가열한 탁주는 $30^{\circ}C$에서 2주간 저장하는 동안 산도 및 pH변화를 보이지 않았으나 점도가 다소 증가하는 경향을 보였다. 효모의 살균효과 12D를 얻기 위한 가열온도가 $70^{\circ}C$에서 $85^{\circ}C$로 증가할 수록 화독냄새와 쓴 맛은 증가하였으며 따라서 탁주의 전체적인 기호도가 저하하였다. 그러나 $80^{\circ}C$에서 가열시간을 8D에서 12D로 증가시킬 경우 온도증가에서처럼 커다란 품질변화가 나타나지 않았다. 광범위한 품질평가시험결과 연속식 살균장치에서 $80^{\circ}C$에서 탁주효모의 10D에 해다하는 23초동안 가열살균하는 것이 탁주의 저온살균조건으로 가장 적합하다는 결론을 얻었다.

  • PDF

자기포화를 이용한 강자성체의 와전류검사장비 개발 (Development of Eddy Current Testing System using Magnetic Saturation in ferromagnetic Materials)

  • 성제중;신용훈;엄태건;강석철;권영호;서동만
    • 비파괴검사학회지
    • /
    • 제23권4호
    • /
    • pp.356-363
    • /
    • 2003
  • 플랜트, 산업용 설비로서 사용되어지고 있는 강관의 결함 검출을 위한 와전류검사장비를 개발하였다. 강관은 내부 불균일 한 전자기적 특성을 포함하고 있는 자성체로서 와전류검사의 응답신호를 왜곡시키므로 이러한 전자기적 특성의 균일화를 위해 자기포화가 요구된다. 자기포화가 없을 경우 결함신호는 잡음신호와 구별되지 않았으나 약 0.62A의 전류가 코일에 가해졌을 때 자기포화되어 결함을 검출 할 수 있었다 자기포화형 탐촉자는 헬름홀츠 코일을 적용하여 제작하였고 내부 대역 통과필터를 이용하여 직류자기장으로 야기되는 잡음신호를 최소화하였다. 개발된 장비를 이용한 현장실험 결과 1m/sec의 이송속도에서 관통홀$({\phi}=2.0mm)$ 결함을 정확히 검출 할 수 있었다.

Molecular Beam Epitaxial Growth of Oxide Single Crystal Films

  • Yoon, Dae-Ho;Yoshizawa, Masahito
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.508-508
    • /
    • 1996
  • ;The growth of films have considerable interest in the field of superlattice structured multi-layer epitaxy led to realization of new devices concepts. Molecular beam epitaxy (MBE) with in situ observation by reflection high-energy electron diffraction (RHEED) is a key technology for controlled layered growth on the atomic scale in oxide crystal thin films. Also, the combination of radical oxygen source and MBE will certainly accelerate the progress of applications of oxides. In this study, the growth process of single crystal films using by MBE method is discussed taking the oxide materials of Bi-Sr-Ca-Cu family. Oxidation was provided by a flux density of activated oxygen (oxygen radicals) from an rf-excited discharge. Generation of oxygen radicals is obtained in a specially designed radical sources with different types (coil and electrode types). Molecular oxygen was introduced into a quartz tube through a variable leak valve with mass flowmeter. Corresponding to the oxygen flow rate, the pressure of the system ranged from $1{\;}{\times}{\;}10^{-6}{\;}Torr{\;}to{\;}5{\;}{\times}{\;}10^{-5}$ Torr. The base pressure was $1{\;}{\times}{\;}10^{-10}$ Torr. The growth of Bi-oxides was achieved by coevaporation of metal elements and oxygen. In this way a Bi-oxide multilayer structure was prepared on a basal-plane MgO or $SrTiO_3$ substrate. The grown films compiled using RHEED patterns during and after the growth. Futher, the exact observation of oxygen radicals with MBE is an important technology for a approach of growth conditions on stoichiometry and perfection on the atomic scale in oxide. The oxidization degree, which is determined and controlled by the number of activated oxygen when using radical sources of two types, are utilized by voltage locked loop (VLL) method. Coil type is suitable for oxygen radical source than electrode type. The relationship between the flux of oxygen radical and the rf power or oxygen partial pressure estimated. The flux of radicals increases as the rf power increases, and indicates to the frequency change having the the value of about $2{\times}10^{14}{\;}atoms{\;}{\cdots}{\;}cm^{-2}{\;}{\cdots}{\;}S^{-I}$ when the oxygen flow rate of 2.0 seem and rf power 150 W.150 W.

  • PDF

250 m 급 Bi-2223/Ag 고온 초전도선재 제조 (Fabrication of 250 m class Bi-2223/Ag HTS Tapes)

  • 하홍수;오상수;하동우;장현만;김상철;송규정;박찬;권영길;류강식
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발 (Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor)

  • 정현규;이동훈;이윤상;허형;정용무
    • 비파괴검사학회지
    • /
    • 제24권2호
    • /
    • pp.164-170
    • /
    • 2004
  • 중수로 내부구조물 중 칼란드리아관(CT)와 액체주입노즐관(LIN)은 서로 수평으로 90도 교차되게 배열되어 있으며 원자로 내의 열, 방사선, 하중에 의해 creep 현상이 발생되어 처짐이 일어난다. 칼란드리아관은 액체주입노즐관과 동일 재료이나 운전 온도와 방사선 조사량으로 인해 액체주입노즐관에 비해 상당히 열악한 조건에 노출되어 있으므로 처짐이 심각할 것으로 예상된다. 만약 두 관의 접촉이 발생되면 원전 안전성에 영향을 미칠 것이므로 인접관에 대한 접촉여부 점검은 중수로 안전현안 중 하나이다. 이러한 접촉여부를 확인하기 위하여 핵연료채널 내부로 탐촉자를 삽입하여 인접관과의 교차점에서 간격을 직접측정하기 위한 방법으로 원거리장 와전류검사 (RFECT) 기술을 적용하였다. 핵연료채널 인접관인 액체주입노즐관 신호 취득시 발생 가능한 잡음 신호(두께변화, Lift-off, 수축)에 대해 체적적분법에 의한 모델링으로 조사하였고, 신호와 잡음과의 분리 가능한 조건을 확인하였다. 원거리장 와전류검사 적정 조건은 민감도와 투과력 그리고 잡음신호 등을 동시에 고려하여 주파수 1kHz와 코일간격 200m로서 결정하였다. 원거리장 와전류검사 실험 결과 칼란드리아관과 액체주입노즐관 사이의 간격 변화에 대한 신호 특성을 전압평면을 이용하여 상관관계를 도출하였다.

저전도율 유체 측정에서 소형 전자기유량계의 신호 특성 (Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement)

  • 임기원;정성수
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.613-620
    • /
    • 2016
  • 유체의 전도율(conductivity)이 전자기유량계의 특성에 미치는 영향을 평가하기 위해 소형 전자기 유량계를 설계 제작하였다. 유량계의 측정관(measuring tube)은 $4mm{\times}3mm$의 직사각형 단면을 가지며 길이는 9 mm이다. 전극은 직경이 1.5 mm인 점전극과 단면이 $2mm{\times}3mm$인 면전극으로 설계하였다. 코일의 열 발생에 영향을 미치는 자화주파수, 회전수 및 굵기를 변화시키면서 최적값을 찾았다. 최적화된 측정관은 자속밀도(magnetic flux density) 0.04 T (400 gauss)를 발생시키며 안정되고, 선형적인 유량신호를 얻을 수 있었다. 유량계를 특성을 평가하기 위해 중량식 유량계 교정 장치를 제작하였다. 유동율 범위는 최대 $1.17{\times}10^{-5}m^3/s$(700 cc/min)이며 ISO규격에 따라 유동량 결정의 불확도를 평가하였으며 크기는 0.06 % 이내이었다. 유체의 전도율은 $3-11{\mu}S/cm$ 사이에서 조절하였다.

노출된 영구 심박조율기의 치험례 (Clinical Experience of Exposed Pacemakers)

  • 오득영;김태형;이종원;이백권;한기택;안상태;최윤석
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.753-756
    • /
    • 2005
  • In the cases of severe arrythmia and conduction failure, a permanent implanted pacemaker is considered an essential treatment modality with less complication rate, broad indications and low morbidity. However, some pacemakers needs to be removed or replaced due to infection, in need of a lead upgrade, elective replacement, conduction failure or insulation failure. The most common indication for pacemaker extraction is infection. Conservative treatments such as administration of intravenous antibiotics and limitation of debridement are not effective and the removal of the entire pacing system is considered to be the best approach to pacemaker pocket infection. Although a locking stylet, a laser sheath and other newer methods of transvenous lead extraction have been proven to be effective, all leads cannot be removed. Moreover, major complications such as, cardiac tamponade and respiratory arrest during leads extraction procedure should not be ignored. We experienced two cases of exposed pacemakers in the subclavicular region. After removing the pacemaker body, exposed proximal lead was pulled out and cut off. The end of remnant external insulation tube was tied to prevent infection propagation between external insulation tube and inner metalic coil. Wounds were covered by local flap coverage. No other problems were detected during the one-year follow-up. Since there are few reports on lead-preserving method of treating limited infection of exposed pacemakers, we would like to present our new method for treating exposed pacemakers.