• Title/Summary/Keyword: Coil performance

Search Result 601, Processing Time 0.023 seconds

A Visual Study on Nucleate Boiling Phenomena in a Closed Two-Phase Thermosyphon (밀폐형 2상 열사이폰내의 비등현상에 관한 가시화 연구)

  • 강환국;오광헌;김철주;박이동;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.185-198
    • /
    • 1995
  • This is an experimental study conducted to visualize the nucleate boiling phenomena and flow regimes occurring inside the liquid pool in a closed two-phase thermosyphon. To meet this purpose, an annular-type thermosyphon was designed and manufactured using a glass tube and a stainless steel tube, being assembled axisymmetrically. The heat to be supplied to the working fluid is generated within a very thin layer of stainless steel tube wall by applying a high frequency electromagnetic field through the induction coil, axisymmetrically set around the evaporator zone. Some important results were as follows ; 1) Considering the structural complexity of the tested thermosyphon, it showed good performance for the range of heat flux 2< q" <25kW/$m^2$ and saturation vapor pressure, 0.1<Pv<1.1bar 2) different type of nucleating boiling regimes were observed as described below, -Pulse boiling regime : Flow pattern changed cyclically with time during 1 cycle of pulse boiling process. The onset of Nucleation was followed by expulsive growing of vapor bubble, resulting in the so called blow-up phenomenon, massive expulsion of large amount of liquid around the bubble. -Transient : Some spherical vapor bobbles were observed growing out from 2~3 nucleating sites, that was dispersed at the lower part of the heated tube wall in the liquid pool. But the rest upper region above the nucleating sites were filled with churns or bubbles of vapor. -Continuous nucleate boiling regime : The whole zone of evaporator was filled with lots of spherical vapor bubbles, and the bubbles showed tendency to decrease in diameter as the heat flux increased.ased.

  • PDF

Improved Control Algorithm Development for Control Element Drive Mechanism Control System (제어봉구동장치제어계통의 개선된 제어 알고리즘 개발)

  • Kim, Byeong-Moon;Lee, Young-Ryul;Han, Jae-Bok;You, Joon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.761-765
    • /
    • 1995
  • The old Timing Controller for Control Element Drive Mechanism (CEDM) is designed as an open loop control system because it is difficult to mount sensors within the Control Element Drive Mechanism(CEDM) which is operating under the pressure boundary of the reactor vessel. In this work new method which can be used to detect the CEDM operational conditions without mounting sensors within the CEDM housing is developed in order to resolve problems of the old Timing Controller. By using the developed new method, the new Timing Controller for the CEDM is designed as a closed loop controller which has features of the control rod drop prevention, fine position control and the coil life time extension. The algorithm developed under closed loop control concept resolves most problems occurred in the old Timing Controller and improves the performance and reliability of the system. During designing and testing of the Timing Controller algorithm, the real time CEDM simulator developed here was used. And all functions of the developed algorithm were verified using CEDM simulator with the real data collected from the site. The results show that the Timing Controller performs its intended functions properly.

  • PDF

Optimal Design and Performance Evaluation of X-type Magnetic Spring Suspension for Commercial Vehicle Seat (상용차 시트용 X-형 구조 마그네틱 현가기구의 최적 설계 및 성능평가)

  • Kwac, Lee Ku;Kim, Hong Gun;Song, Jung Sang;Shin, Hee Jae;Seo, Min Kang;Kim, Byung Ju;An, Kay Hyeok;Lee, Hye Min;Han, Woong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.5
    • /
    • pp.456-464
    • /
    • 2014
  • Commercial vehicle drivers typically feel more fatigued compared to general-public drivers. because they spend longer periods of time driving and experience more rough road conditions. This study showed that the application of a magnet, a linear spring, and a seat suspension with nonlinear characteristics was the optimal design to increase comfort while driving. The resonant frequency for the optimal design suspension was 2.8 Hz, and the stiffness was analyzed through displacement-load experiments. Vibration transmissibility was analyzed by suspension stiffness and the existing dynamic compression. The magnetic spring type was at 0.875. As a result, the X-type magnetic spring performed better than the existing spring at 0.729.

Antimicrobial Activity of Water-soluble Extract from Artemisia princeps var. orientalis (Artemisia princeps var. orientalis 수용성 추출물의 항균효과)

  • Cho, Hwa-Young;Yoon, Sung-Yong;Park, Jeong-Jin;Yun, Kung-Won;Park, Jong-Moon
    • KSBB Journal
    • /
    • v.21 no.2
    • /
    • pp.129-132
    • /
    • 2006
  • The importance of natural preservative has increased in recent years. The natural preservatives have been used in the field of foods, cosmetics and pharmacology. In the present work Artemisia sp., well recognized for their effect of antimicrobial activity, were extracted by methanol and water sequentially for selecting only water-soluble compounds that can be used as additives in food and cosmetics. Antimicrobial activities of water extracts from stem and leaf of Artemisia princeps var. orientalis were investigated by the disc diffusion method. Two gram positive bacteria(Staphylococcus aureus and Bacillus subtilis) and three gram negative bacteria(Escherichia coil, Agrobacterium tumefaciens and Pseudomonas putida) were used for antimicrobial activity studies. The water-soluble compounds from methanol extract showed higher antimicrobial activity than only water extract to these bacteria. Comparative evaluation of water-soluble metabolite profiles with caffeic acid that is known as an antimicrobial compound from Artemisia sp. was performed by high performance liquid chromatography with photo-diode array detection.

Design and Implementation of PIC/FLC plus SMC for Positive Output Elementary Super Lift Luo Converter working in Discontinuous Conduction Mode

  • Muthukaruppasamy, S.;Abudhahir, A.;Saravanan, A. Gnana;Gnanavadivel, J.;Duraipandy, P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1886-1900
    • /
    • 2018
  • This paper proposes a confronting feedback control structure and controllers for positive output elementary super lift Luo converters (POESLLCs) working in discontinuous conduction mode (DCM). The POESLLC offers the merits like high voltage transfer gain, good efficiency, and minimized coil current and capacitor voltage ripples. The POESLLC working in DCM holds the value of not having right half pole zero (RHPZ) in their control to output transfer function unlike continuous conduction mode (CCM). Also the DCM bestows superlative dynamic response, eliminates the reverse recovery troubles of diode and retains the stability. The proposed control structure involves two controllers respectively to control the voltage (outer) loop and the current (inner) loop to confront the time-varying ON/OFF characteristics of variable structured systems (VSSs) like POESLLC. This study involves two different combination of feedback controllers viz. the proportional integral controller (PIC) plus sliding mode controller (SMC) and the fuzzy logic controller (FLC) plus SMC. The state space averaging modeling of POESLLC in DCM is reviewed first, then design of PIC, FLC and SMC are detailed. The performance of developed controller combinations is studied at different working states of the POESLLC system by MATLAB-Simulink implementation. Further the experimental corroboration is done through implementation of the developed controllers in PIC 16F877A processor. The prototype uses IRF250 MOSFET, IR2110 driver and UF5408 diodes. The results reassured the proficiency of designed FLC plus SMC combination over its counterpart PIC plus SMC.

Development of a Refrigeratory-Based Dehumidifier for Humidity Environment Control in Greenhouse (시설원예 습도환경 제어를 위한 냉각식 제습기 개발)

  • Kang, G.C.;Yon, K.S.;Ryou, Y.S.;Kim, Y.J.;Kang, Y.K.;Paek, Y.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.4
    • /
    • pp.247-255
    • /
    • 2007
  • During the winter season in Korea, the relative humidity of greenhouse at night often exceeds 90% because air temperature inside the greenhouse is usually controlled using a heater with all of windows closed to minimize heat loss, thereby requiring the use of a dehumidifier that can maintain optimum humidity levels of $70{\sim}80%$ to provide a good growth condition of crops. Also, such a high humid condition can cause the development of a pest, such as insects, fungi or diseases. However, the use of most conventional dehumidifiers for low temperature dehumidification is limited because their performance is degraded due to frost accumulation on the evaporator coil. This study was carried out to develop a refrigeratory-based dehumidifier suitable for low temperature dehumidification in greenhouse cultivation. The developed dehumidifier consists of a condenser and an evaporator installed separately so that relative and absolute humidity levels can be reduced when air passed through the condenser and evaporator, respectively. The prototype dehumidifier showed a dehumidification capacity of $5{\sim}7kg/h$ when air with a temperature of $15{\sim}25^{\circ}C$ and a relative humidity of $70{\sim}95%$ came into the dehumidifier. Under the condition that either temperature or relative humidity was fixed, the amount of condensed water was proportional to the levels of both temperature and relative humidity.

A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector (차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구)

  • Kim, Shi-Kuk;Yuk, Hyun-Dai;Yang, Seung-Hyun;Jee, Seung-Wook;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.85-92
    • /
    • 2009
  • This paper studied on the development of standardization tester for the field inspection of the rate of rise spot type heat detector. It was to find the problems of the 4 type's testers such as A type (electric bulb type), B type (halogen lamp type), C type (heating coil type), D type (fumigator type) which were used to check of the rate of rise spot type heat detector in inspection for the fire protection. To identify those problems, this paper described about the development of standardization tester for the field inspection of the rate of rise spot type heat detector and that have the function of auto setting temperature more $30^{\circ}C$ higher than room temperature and keep the constant temperature. And keep the constant wind velocity of 85cm/sec. Performance verification results of the developed prototype that had same conditions such as the sensitivity test conditions at the type approval of the rate of rise spot type heat detector.

Frequency Characteristics of 2-Layer Spiral Planar Inductor (2층 나선형 박막 인덕터의 주파수 특성)

  • Kim, Jae-Wook;Ryu, Chang-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4101-4106
    • /
    • 2011
  • In this study, we propose that the structures of 2-layer spiral planar inductors have a lower spiral coil and via increasing inductance in limited possession are and confirm the frequency characteristics. The structures of inductors have Si thickness of $300{\mu}m$, $SiO_2$ thickness of $7{\mu}m$. The width of Cu coils and the space between segments have $20{\mu}m$, respectively. The number of turns of coils have 3. The performance of spiral planar inductors was simulated to frequency characteristics for inductance, quality-factor, SRF(Self- Resonance Frequency) using HFSS. The 2-layer spiral planar inductors have inductance of 3.2nH over the frequency range of 0.8 to 1.8 GHz, quality-factor of maximum 8.2 at 2.5 GHz, SRF of 5.8 GHz. Otherwise, 1-layer spiral planar inductors have inductance of 1.5nH over the frequency range of 0.8 to 1.8 GHz, quality-factor of maximum 18 at 8 GHz, SRF of 19.2 GHz.

A multi-functional cable-damper system for vibration mitigation, tension estimation and energy harvesting

  • Jung, Hyung-Jo;Kim, In-Ho;Koo, Jeong-Hoi
    • Smart Structures and Systems
    • /
    • v.7 no.5
    • /
    • pp.379-392
    • /
    • 2011
  • This paper presents a multi-functional system, consisting of a magnetorheological (MR) damper and an electromagnetic induction (EMI) device, and its applications in stay cables. The proposed system is capable of offering multiple functions: (1) mitigating excessive vibrations of cables, (2) estimating cable tension, and (3) harvesting energy for wireless sensors used health monitoring of cable-stayed bridges. In the proposed system, the EMI device, consisting of permanent magnets and a solenoid coil, can converts vibration energy into electrical energy (i.e., induced emf); hence, it acts as an energy harvesting system. Moreover, the cable tension can be estimated by using the emf signals obtained from the EMI device. In addition, the MR damper, whose damping property is controlled by the harvested energy from the EMI device, can effectively reduce excessive cable vibrations. In this study, the multi-functionality of the proposed system is experimentally evaluated by conducting a shaking table test as well as a full-scale stay cable in a laboratory setting. In the shaking table experiment, the energy harvesting capability of the EMI device for wireless sensor nodes is investigated. The performance on the cable tension estimation and the vibration mitigation are evaluated using the full-scale cable test setup. The test results show that the proposed system can sufficiently generate and store the electricity for operating a wireless sensor node twice per day, significantly alleviate vibration of a stay cable (by providing about 20% larger damping compared to the passive optimal case), and estimate the cable tension accurately within a 2.5% error.

CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber (덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD)

  • Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2021
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. A curved constant temperature chamber was constructed that can be tested under the same conditions as in the natural state so that the research can be conducted in which frost does not occur on the outdoor unit of the heat pump regardless of the season. Simulations were performed to verity whether such a curved constant temperature chamber has feasibility as an experimental device. For CFD conditions, the length of the straight duct in front of the outdoor unit located in the duct-type constant temperature chamber was 1, 5, 10 and 15 times the diameter of the duct. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.