• Title/Summary/Keyword: Coil Gap Size

Search Result 27, Processing Time 0.02 seconds

Design and Fabrication of Implantable LC Resonant Blood Pressure Sensor (인체 삽입용 LC 공진형 혈압 센서 디자인 및 제작)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.171-176
    • /
    • 2013
  • In this paper, we present a MEMS (micro-electro-mechanical system) implantable blood pressure sensor which has designed and fabricated with consideration of size, design flexibility, and wireless detection. Mechanical and electrical characterizations of the sensor were obtained by mathematical analysis and computer aided simulation. The sensor is composed of two coils and a air gap capacitor formed by separation of the coils. Therefore, the sensor produces its resonant frequency which is changed by external pressure variation. This frequency movement is detected by inductive coupling between the sensor and an external antenna coil. Theoretically analyzed resonant frequency of the sensor under 760 mmHg was calculated to 269.556 MHz. Fused silica was selected as sensor material with consideration of chemical and electrical reaction of human body to the material. $2mm{\times}5mm{\times}0.5mm$ pressure sensors fitted to radial artery were fabricated on the substrates by consecutive microfabrication processes: sputtering, etching, photolithography, direct bonding and laser welding. Resonant frequencies of the fabricated sensors were in the range of 269~284 MHz under 760 mmHg pressure.

Investigation of Electromagnetic Force for Magnetic Contactor of Railway Vehicles (철도차량용 전자접촉기 전자코일의 전자기력 특성 연구)

  • Jung, Jooyoung;Park, Ji-Won;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.324-330
    • /
    • 2016
  • A magnetic contactor is a switching device widely used for electric circuits. For the operation of magnetic contactors, magnetic coils are essential; these coils create and interrupt the electric circuit. In this paper, the finite element analysis model was developed to reflect the experimental data, and was verified through alteration of the applied voltages and the numbers of turns. Effects of electromagnetic force on the geometrical variations of the facing poles for fixed and moving cores of two magnet coils were investigated. In addition, effects of slope and air gap size between two facing poles on the electromagnetic force were explored through the distribution of the magnetic flux density in the magnetic coils of a push-type solenoid. Through this analysis, the characteristics of the electromagnetic force against the facing poles were explored.

Proposal of Magnetic Coupling Type Implantable Middle Ear Hearing Aid (자기결합방식의 이식형 인공중이의 제안)

  • 정영숙;윤영호;박재훈;송병섭;이승하;김명남;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.487-495
    • /
    • 1998
  • In this paper, a new type of implantable middle ear hearing aid, which consists of external loop coil, a small magnet and a simple external device, is proposed. The internal device of proposed type consists of only a small magnet and the external device does not need to be positioned behind the ear or in the ear canal. The proposed type is excellent in cosmetic sides and very convenient to use, because the external device can be hidden in upper garment and collar of clothes. Also, purposely this type doesn't need to be small on the size of battery, which means it has longer battery life. Therefore, the battery is not necessary to be charged frequently. It also can solve the difficulty of gap calibration at surgical operation which conventional Implantable middle. Therefore, the battery is not necessary to be charged frequently. It also can solve the difficulty of gap calibration at surgical operation which conventional implantable middle ear hearing aid has. We investigate the performance of proposed implantable middle ear bearing aid and we analyze that proposed type is appropriate for mild and severe hearing impaired person and the result of experiment showed the accuracy of our analysis. For the validation of our analysis we used the temporal bone at the experiment and confirm that ossicles can be vibrated when the proposed system In startled in the body.

  • PDF

A Design and Performance Evaluation of Semi-active MR Damper for the Smart Control of Construction Structures (건설구조물의 스마트 제어를 위한 준능동 MR 감쇠기의 설계 및 성능평가)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.165-171
    • /
    • 2009
  • This research developed two semi-active MR dampers whose gaps in the orifice area were different from each other, and evaluated their damping performance by loading tests. The Damping performance of MR dampers characteristically depends on various factors like their material and mechanical ones, but most importantly on the size of gap in the orifice area. For this research, we designed the orifice gaps of two dampers as each 1.0mm and 2.0mm, both with the 80mm outer diameter of the orifice. We also designed two loading test sets with different input currents, and acquired different control ability from them. The acquired test results were analyzed and evaluated with their maximum and minimum damping force and also their dynamic range from the force-displacement hysteresis loops and the force-input current relationship curve. This research clearly proved how the damping performance of control devices depends on the gap effect, and also presented a possibility that the two dampers developed in this research could be used for the smart control of construction structures by effectively adapting the input current and the number of coil turns.

Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer (소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구)

  • Lee, Hoon-Hee;Jung, Chang-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, a Small-sized and planer resonator design of Magnetic Resonance - Wireless Power Transfer(MR-WPT) were proposed for practical applications of mobile devices, such as a laptop, a smart-phone and a tablet pc. The proposed MR-WPT system were based on four coil MR-WPT and designed as a transmitter part (Tx) and a receiver part (Rx) both are the same shape with the same loop and resonator. There are four different spiral coil type of resonators with variable of line length, width, gap and turns in $50mm{\times}50mm$ size. The both of top and bottom side of substrate(acrylic; ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$) ere used to generate high inductance and capacitance in limited small volume. Loops were designed on the same plane of resonator to reduce their volume, and there are three different size. The proposed MR-WPT system were fabricated with two acrylic substrate plane of Tx and Rx each, the Rx and Tx loops and resonators were fabricated of copper sheets. There are 12 combinations of 3 loops and 4 resonators, each combination were measured to calculate transfer efficiency and resonance frequency in transfer distance from 1cm to 5cm. The measured results, the highest transfer efficiency was about 70%, and average transfer efficiency was 40%, on the resonance frequency was about 6.78 MHz, which is standard band by A4WP. We proposed small-sized and planer resonator of MR-WPT and showed possibility of mobile applications for small devices.

Optimal Design of New Magnetorheological Mount for Diesel Engines of Ships (선박용 디젤엔진을 위한 새로운 MR 마운트의 최적설계)

  • Do, Xuan-Phu;Park, Joon-Hee;Woo, Jae-Kwan;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.3
    • /
    • pp.209-217
    • /
    • 2013
  • This paper presents an optimal design of a magnetorheological(MR) fluid-based mount(MR mount) that can be used for to vibration control in diesel engines of ships. In this work, a mount that uses mixed-modes(squeeze mode, flow mode, and shear mode) is proposed and designed. To determine the actuating damping force of the MR mount required for efficient vibration control, the excitation force from a diesel engine is analyzed. In this analysis, a model of a V-type engine is considered. The relationship between the velocity and pressure of gas in terms of the torque acting on the piston is derived. Subsequently, by integrating the field-dependent rheological properties of commercially available MR fluid with the excitation force, the appropriate size of the MR mount is designed. In addition, to achieve the maximum actuating force under geometric constraints, design optimization is undertaken using the ANSYS parametric design language software. Through magnetic density analysis, optimal design parameters such as the bottom gap and radius of coil are determined.

Optimal Design of New MR Mount for Diesel Engine of Ship (선박디젤엔진을 위한 새로운 MR 마운트의 최적설계)

  • Do, Xuan-Phu;Park, Joon-Hee;Woo, Jae-Kwan;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.93-99
    • /
    • 2012
  • This paper presents an optimal design of magnetorheological (MR) fluid based mount (MR mount in short) which can be applicable to vibration control of diesel engine of ship. In this work, a mixed - mode including squeeze mode, flow mode and shear mode is proposed and designed. In order to determine actuating damping force of MR mount required for efficient vibration control, excitation force from diesel engine is analyzed. In this analysis, a model of V-type engine is considered and the relationship between velocity and pressure of gas in torque of the piston is derived. Subsequently, by integrating the field-dependent rheological properties of commercially available MR fluid with the excitation force an appropriate size of MR mount is designed. In addition, in order to achieve maximum actuating force with geometric constraints design optimization is undertaken using ANSYS software. Through the magnetic density analysis, optimal design parameters such as bottom gap and radius of coil are determined.

  • PDF