• Title/Summary/Keyword: Coil Break

Search Result 17, Processing Time 0.026 seconds

Condition Monitoring for Coil Break Using Features of Stationary Rolling Region (정상 압연 구간의 특징을 이용한 판 파단의 상태감시)

  • Oh, J.S.;Yang, S.W.;Shim, M.C.;Caesarendra, W.;Yang, B.S.;Lee, W.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1252-1259
    • /
    • 2009
  • Due to the international competition and global pressure, the roll speed is increased. However, higher speeds increase the power density in the process as well as the plant's potential to react with vibrations. Under certain operating conditions, vibrations may occur, which again cause chattermarks, strip rupture or coil break fault. The appropriate condition monitoring is needed to improve product quality and availability. The aim of condition monitoring is to reduce maintenance costs, increase productivity and improve product quality. This paper proposes a condition monitoring tool designed for the classification of coil break fault. This method is used to cold rolling mill for faults monitoring based on vibration and motor current signals. The results show that the performance of classification has high accuracy based on experimental work.

Development and Characteristics of a New Insulator between Turns of Superconducting Coil (초전도 Coil의 새로운 turn간 절연재료의 개발 및 특성)

  • 박영욱;이동성;이정원;곽동순;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.26-29
    • /
    • 2002
  • Polyimide-epoxysilane (coupling agent) composites were reacted with oligomeric PDMS, a condensation product of difunctional silane, by a sol-gel process and were then dried into films. And then, the surface, mechanical, and electric properties were measured. The study showed that PDMS existed in the polymide matrix by the use of FT-IR. In the mechanical properties, the maximum elongation and toughness was increased in the polyimide with silane-groups. But the maximum tensile strength was slightly decreased. And the intensive dispersion of the silane-groups on the surface of polyimide was ascertained through XPS measurement. In the electric properties. AC break down voltage was increased by increasing the amount of difunctional silane. This experiment showed that PDMS added polyimide had better mechanical and electric properties than classical materials.

Vibration Pattern Prediction through The Analysis on the Break-up Mode and the Heat Transfer Relationship of Slim Speaker Diaphragm (슬림 스피커 진동판의 분할진동 모드와 열전달 관계 분석을 통한 진동 패턴 예측)

  • Kim, Hyun-Kab;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.109-115
    • /
    • 2016
  • In this paper, In this paper, we use two methods to compare the slim speakers. That way, the diaphragm scan using laser and diaphragm photographed using a thermal imaging camera. Slim speaker has the structure of a flat plate type. Break-up mode by this characteristic is displayed in a larger size. Further, since the installation space is narrow, it has limited moving coil cooling. As a result, the break-up mode slim speakers, a significant impact on quality. In this study, try to connect the break-up mode of the diaphragm, the heat transfer mode of the diaphragm. Experiment for comparison, a two-step. The first step is to measure the divided vibration through the vibration plate scan. The second step measures the diaphragm photographed using a thermal imaging camera. Then, compare the results of both of the same frequency. Thus, comparing the heat transfer pattern and the pattern of break-up mode. Tend to be analysis of break-up mode from the pattern comparison, and document for the optimum design.

Relationship Analysis of Break-up Mode and Heat Transfer of Micro-Speaker Diaphragm (마이크로 스피커 진동판에 대한 분할진동 모드와 열전달의 관계 분석)

  • Kim, Hyun-Kab;Kim, Hie-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.333-336
    • /
    • 2017
  • A speaker diaphragm generates a divided vibration. The influence of the break-up mode is sufficient to cause a shape change in the diaphragm. In this paper, is widely used in ultra-thin multi-media devices, including smart phones is the advance guard of the IT sector, the micro-speakers and its target. Micro-speakers are different from general speakers. The plate has structural form and space constraints. In particular, they utilize a closed-type drive space. It is difficult to provide cooling for the auxiliary suspension structure because of the heat generated in the moving coil. The present study considered the relationship between the break-up mode and the heat transfer of the diaphragm. An experiment was conducted in two stages to compare the embodiment of the break-up mode and heat transfer in a certain frequency range. The changes in the heat were determined through measurements and thermal imaging of the break-up mode. The break-up mode tendency of the diaphragm could be rapidly predicted based on the imaging results using the thermal imaging camera. This will help in the optimal design of micro-speakers.

Properties of Electrical Performance by Inverter Surge on Stator Coil of Traction Motor (인버터 서지에 의한 견인전동기 고정자 권선의 전기적 특성 변화)

  • Park, Hyun-June;Jang, Dong-Uk;Choi, Nam-Ho;Choi, Jong-Sun;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1285-1287
    • /
    • 2003
  • The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking. the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss($tan{\delta}$), capacitance and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor.

  • PDF

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge (과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화)

  • 박현준;장동욱;이길헌;최종선;김저우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

SBLOCA AND LOFW EXPERIMENTS IN A SCALED-DOWN IET FACILITY OF REX-10 REACTOR

  • Lee, Yeon-Gun;Park, Il-Woong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.347-360
    • /
    • 2013
  • This paper presents an experimental investigation of the small-break loss-of-coolant accident (SBLOCA) and the loss-of-feedwater accident (LOFW) in a scaled integral test facility of REX-10. REX-10 is a small integral-type PWR in which the coolant flow is driven by natural circulation, and the RCS is pressurized by the steam-gas pressurizer. The postulated accidents of REX-10 include the system depressurization initiated by the break of a nitrogen injection line connected to the steam-gas pressurizer and the complete loss of normal feedwater flow by the malfunction of control systems. The integral effect tests on SBLOCA and LOFW are conducted at the REX-10 Test Facility (RTF), a full-height full-pressure facility with reduced power by 1/50. The SBLOCA experiment is initiated by opening a flow passage out of the pressurizer vessel, and the LOFW experiment begins with the termination of the feedwater supply into the helical-coil steam generator. The experimental results reveal that the RTF can assure sufficient cooldown capability with the simulated PRHRS flow during these DBAs. In particular, the RTF exhibits faster pressurization during the LOFW test when employing the steam-gas pressurizer than the steam pressurizer. This experimental study can provide unique data to validate the thermal-hydraulic analysis code for REX-10.

A Study on the High Speed Breaking of Parallel Arcing (병렬아크의 고속 차단에 관한 연구)

  • Kim, Il-Kwon;Ji, Hong-Keun;Kim, Sung-Uk;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.327-331
    • /
    • 2008
  • This paper dealt with high speed breaking method to parallel arcing in low-voltage systems. The proposed high speed breaking circuit consists of a Rogowski coil and an integrator, and operates with an earth leakage circuit breaker (ELCB). A parallel arcing state was simulated by a short circuit using stripped wires. In this test, we analyzed tripping characteristics of the circuit breaker by the length of wires from 5m to 30m. From the experimental results, we confirmed that the proposed method can break the parallel arcing within a few millisecond.

  • PDF

The Preventive measure and the cause analysis for field coils breaking away from the rotor in hydro generator (수차발전기 회전자 Coil 이탈 원인분석 및 방지대책)

  • Kim, Seung-Hyo;Moon, Hyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1021-1023
    • /
    • 2000
  • This paper presents the preventive measure and the cause for field coils breaking away from the rotor, which lately occurred when No.1 hydro generator was operating in Chung-Ju Dam No.2 Hydro Power Station. In findings, we ascertained the truth of contact between rotor rim and field coils, and think that field coils will break away from the rotor because of mechanical stress according as continuous operation after completion. 1985. Therefore, we conclude that the preventive measure for such a phenomenon is that stopper should be installed between rotor rim and field coils, and bolts should be tightened because of operating characteristic however there are not the design standards for installing stopper in generator rotor internationally.

  • PDF

Design and Control of Ultra-precision Dual Stage with Air bearings and Voice coil motor for nm scanning system (나노 정밀도 스캐닝 용 공기베어링과 보이스 코일 모터의 초정밀 이중 스테이지 설계 및 제어)

  • Kim K.H.;Choi Y.M.;Kim J.J.;Lee M.G.;Lee S.W.;Gweon D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1883-1886
    • /
    • 2005
  • In this paper, a decoupled dual servo (DDS) stage for ultra-precision scanning system with large working range is introduced. In general, dual servo systems consist of a fine stage for short range and a coarse stage for long range. The proposed DDS also consists of a $XY\theta$ fine stage for handling and carrying workpieces and one axis coarse stage. Its coarse stage consists of air bearing guide system and a coreless linear motor with force ripple. The fine has four voice coil motors(VCM) as its actuator. According to a VCM's nature, there are no mechanical connections between coils and magnetic circuits. Moreover, VCM doesn't have force ripples due to imperfections of commutation components of linear motor systems - currents and flux densities. However, due to the VCM's mechanical constraints the working range of the fine is about $25mm^2$. To break that hurdle, the coarse stage with linear motors is used to move the fine about 500mm. Because of the above reasons, the proposed DDS can achieve higher precision scanning than other stages with only one servo. With MATLAB's Sequential Quadratic Programming (SQP), the VCMs are optimally designed for the highest force under conditions and constraints such as thermal dissipations due to its coil, its size, and so on. And for their movements without any frictions, guide systems of the DDS are composed of air bearings. To get precisely their positions, a linear scale with 5nm resolution are used for the coarse stage's motion and three plane mirror laser interferometers with 5nm for the fine's $XY\theta$ motions. With them, on scanning the two stages have same trajectories. The control algorithm is named Parallel method. The embodied ultra-precision scanning system has sub 100nm following error and in-positioning stability.

  • PDF