• Title/Summary/Keyword: Coil Array

Search Result 94, Processing Time 0.03 seconds

Association between High Diffusion-Weighted Imaging-Derived Functional Tumor Burden of Peritoneal Carcinomatosis and Overall Survival in Patients with Advanced Ovarian Carcinoma

  • He An;Jose AU Perucho;Keith WH Chiu;Edward S Hui;Mandy MY Chu;Siew Fei Ngu;Hextan YS Ngan;Elaine YP Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.5
    • /
    • pp.539-547
    • /
    • 2022
  • Objective: To investigate the association between functional tumor burden of peritoneal carcinomatosis (PC) derived from diffusion-weighted imaging (DWI) and overall survival in patients with advanced ovarian carcinoma (OC). Materials and Methods: This prospective study was approved by the local research ethics committee, and informed consent was obtained. Fifty patients (mean age ± standard deviation, 57 ± 12 years) with stage III-IV OC scheduled for primary or interval debulking surgery (IDS) were recruited between June 2016 and December 2021. DWI (b values: 0, 400, and 800 s/mm2) was acquired with a 16-channel phased-array torso coil. The functional PC burden on DWI was derived based on K-means clustering to discard fat, air, and normal tissue. A score similar to the surgical peritoneal cancer index was assigned to each abdominopelvic region, with additional scores assigned to the involvement of critical sites, denoted as the functional peritoneal cancer index (fPCI). The apparent diffusion coefficient (ADC) of the largest lesion was calculated. Patients were dichotomized by immediate surgical outcome into high- and low-risk groups (with and without residual disease, respectively) with subsequent survival analysis using the Kaplan-Meier curve and log-rank test. Multivariable Cox proportional hazards regression was used to evaluate the association between DWI-derived results and overall survival. Results: Fifteen (30.0%) patients underwent primary debulking surgery, and 35 (70.0%) patients received neoadjuvant chemotherapy followed by IDS. Complete tumor debulking was achieved in 32 patients. Patients with residual disease after debulking surgery had reduced overall survival (p = 0.043). The fPCI/ADC was negatively associated with overall survival when accounted for clinicopathological information with a hazard ratio of 1.254 for high fPCI/ADC (95% confidence interval, 1.007-1.560; p = 0.043). Conclusion: A high DWI-derived functional tumor burden was associated with decreased overall survival in patients with advanced OC.

Inactivation of Pathogenic Bacteria by Addition of Thermophilic Bacteria in the Thermophilic Aerobic Oxidation(TAO) System (고온호기산화장치의 고온미생물 첨가에 의한 병원성 미생물의 불활성화)

  • Lee W. I.;H. Tsujii;T. Maki;Lee M. G.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.111-118
    • /
    • 2004
  • This study analyzed temperature increase, microorganism changes, and inactivation of pathogenic microorganisms in pig slurry when treated with thermophilic microorganisms in Thermophilic Aerobic Oxidation(TAO) system. An amount of $6 m^3$ of pig slurry was treated in an $18 m^3(3.0\times2.5\times2.4 m)$ reactor for 5 to 7 days in two groups: the control of pig slurry only and the treatment of pig slurry with 6 liters of thermophilic microorganism(Bacillus sp.). To study the microorganism changes in the reactor, the populations of aerobic mesophilic microorganisms, thermophilic microorganisms and general pathogens were analyzed. To study the inactivation of pathogenic microorganisms, the levels of E. coli, Salmonella sp, Crytosporidium parvum and Giardia lamblia were analyzed. The temperature inside the reactor ranged from 18 to $62^{\circ}C$ for the control while far the treatment group it ranged from 18 to $66^{\circ}C$, showing a slightly higher array. With regard to changes in microorganisms, both mesophilic and thermophilic organisms decreased from $3.1\times10^6$ to $1.2\times10^2$ CFU/ml and from $1.0\times10^4$ to $8.0\times10^1$ CFU/ml, respectively, in the control. In the treatment, on the other hand, mesophilic organisms decreased from $3.0\times10^8$ CFU/ml to $8.6\times10^5$ CFU/ml while thermophilic organisms increased sharply from $2.0\times10^6$ to $1.2\times10^8$ CFU/ml. For pathogens, Salmonella and Giardia were not detected either before or after the treatment, while E. coli and C. parvum were found to be $10^5$ CFU/ml each before treatment and negative after it. From this experiment, it was concluded that thermophilic microorganisms could effectively sanitize liquid compost by generating high temperature in the TAO system, which in turn would inhibit the growth of pathogenic organisms.

  • PDF

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.