• Title/Summary/Keyword: Coil의 위치 변화

Search Result 39, Processing Time 0.024 seconds

Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils (6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.699-706
    • /
    • 2018
  • In this study, we measured signal intensities according to array coil position changes to provide reference data of coil directions and the distances as it deters image quality unless the coils are aligned properly. The multi-purpose MRI phantom was placed in body array coils, and it was moved to the top, bottom, left, and right directions by 2 cm from the center to 10 cm. After obtaining images, signal intensities were measured and compared. The results of this study were as follows: Except for the upward direction, the signal intensities of the reference signal was not significantly different from that of the reference signal intensity within 2cm in both T1 and T2-weighted images. In conclusion, in clinical circumstances which various challenges exist to align the coils exactly on the same lines, array coils should be positioned at least within 2 cm from the center except for the upward direction, on the same line to prevent the image qualities are lowered.

A numerical study on the optimum operation condition for axial oxygen concentration in 8 inch silicon growth by cusp MCZ (8인치 실리콘성장을 위한 커스프 MCZ계에서 축방향 산소분포에 대한 연구)

  • 이승철;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.406-417
    • /
    • 1997
  • A numerical study was conducted on the optimum magnetic field intensity and asymmetric factor for uniform axial oxygen concentration in 8 inch silicon single crystal growing process by magnetic Czochralski method. For constant shape of cusp field, a change of coil and crucible position were compared. In case of symmetric cusp field, magnetic field intensity variation shows concave downward with crystal growing for uniform, axial oxygen concentration. A numerical results show similar value of standard deviation of average oxygen concentration for uniform oxygen concentration between coil and crucible position change. In case of asymmetric cusp field. asymmetric factor is increased with crystal growing to have uniform oxygen concentration.

  • PDF

The Change of Flow Characteristics in Lateral Aneurysm Models for Different Coil Locations (코일 위치에 따른 측방 동맥류 내부 혈류 유동의 변화)

  • 이계한;송계웅;변홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.375-383
    • /
    • 2002
  • Aneurysm embolisation method using coils have been widely used. Micro coils are introduced via a small catheter, and are packed inside of aneurysm sac, which induces intraaneurysmal flow stagnation and thrombus formation. When partial blocking of an aneurysm is inevitable, the location of coils is important since it changes the flow patterns inside the aneurysm, which affect the embolisation process. We measured the flow field inside the partially blocked lateral aneurysm models in vitro, and tried to suggest the effective locations of coils for aneurysm embolisation. Velocity fields are measured using a particle image velocitimeter for different coil locations- proximal neck, distal neck, proximal dome and distal dome. Flow into the aneurysm sac was significantly reduced in the distally blocked models, and coils at distal neck blocked inflow more effectively comparing to those at distal dome. This study suggests that distal neck should be the most effective location for aneurysm embolisation.

Performance Measurement of the Wireless Charging Devices Using Eletromagnetic Induction Techniques (전자기유도방식을 이용한 무선 충전 기기의 구현 및 성능 측정)

  • Ryu, Daun;Kim, Young Hyun;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.237-243
    • /
    • 2015
  • This paper presented the design of wireless power transfer (WPT) system using electromagnetic induction techniques and analysed WPT efficiency. Also, we presented the optimum coil condition by measuring the efficiency variation according to some receiving coil parameter changes. Voltage change is measured by receiving coil position for the designed transmitting and receiving circuit. Voltage change according to inductance variation at the same position and charging time are compared at the same environment by using a developed application program to realize an optimum WPT system. Developed wireless power transfer system using electromagnetic induction techniques uses 125 kHz. It takes 16 minutes by using wired charger, and 23 minutes by using wireless charger for charging from 50% to 60% charging status.

Dependance of hot-zone position on AlN single crystal growth by PVT method (PVT법에 의한 AlN 단결정 성장에서 Hot-Zone 의존성)

  • Yin, Gyong-Phil;Kang, Seung-Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.2
    • /
    • pp.84-88
    • /
    • 2016
  • AlN single crystals were grown by the PT (Physical vapor transport) method with position-changable induction coil. And the graphite crucible dimensioned ${\Phi}90{\times}H120$ was used on processing. The temperature was $1950{\sim}2050^{\circ}C$ and ambient pressure was 150~1 Torr. And the hot-zone was changed according to times on growing for result comparison. When hot-zone by coil is located below far enough (> 40 mm) from AlN crystal concentration position, the as-grown crystals physical size is better ($300{\mu}m/hr$) than another condition, but the condition-reproducibility was very poor. However the closer the distance between hot-zone and AlN growing posion, the smaller the size of as-grown crystal and the rarer the generation of the crystal nuclear, but the crystal growing condition is stable for quality. The best condition for both growth rate and quality is gained when the starting position of hot-zone coil is about 20 mm distance from growing position. For the best growth condition, the position of hot-zone is very sensitive factor and the further more the condition of speed of coil shift also must control.

Dynamic Characteristics of Moving Coil Linear Oscillatory Actuator Considering the Variable Inductance and Push/pull Effects (가동차 위치에 따른 인덕턴스 변화와 Push/Pull 효과를 고려한 가동코일형 LOA의 동특성)

  • Jeong, Sang-Sub;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.307-314
    • /
    • 2001
  • A moving coil linear oscillatory actuator is consisted of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure and an iron core as a pathway for magnetic flux. The variation of mover position and the consequent changes of coil flux path affect the coil inductance, because coil flux leaks at the open region of LOA stator. The interaction between permanent magnet and armature field is to shift the airgap flux density variation due to the magnet alone by a certain amount. The unbalanced reciprocation force due to armature reaction field decreases the advantage of moving coil LOA, such as a high degree of linearity and controllability in the force ad motion control. This paper firstly describes the coil inductance, the deviation of flux density, and the unbalanced reciprocation force, which are derived form the permeance model of LOA. Secondly, the analytical method are verified using the 2D finite element method and tests. Finally, the dynamic simulation algorithm taking the armature reaction effect and variable inductance into account, is proposed and confirmed through the experiment.

  • PDF

Intraaneurysmal Blood Flow Changes for the Different Coil Locations (코일 위치에 따른 동맥류 내부 혈류유동의 변화)

  • 이계한;정우원
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.295-300
    • /
    • 2004
  • Coil embolization technique has been used recently to treat cerebral aneurysms. When a giant or a multilobular aneurysm are treated by roils, filling an aneurysm sac completely with coils is difficult and partial blocking of an aneurysm sac is inevitable. Blood flow characteristics, which nay affect the embolization process of an aneurysm sac, are changed by the locations of coils for the Partially blocked aneurysms. Blood flow fields are also influenced by the geometry of a parent vessel. In order to suggest the coil locations effective for aneurysm embolization, the blood flow fields of lateral aneurysm models were analyzed for the different coil locations and parent vessel geometries. Three dimensional pulsatile flow fields are analyzed by numerical methods considering non-Newtonian viscosity characteristics of blood. Flow rate into the aneurysm sac (inflow rate) and wall shear stress, which are suspected as flow dynamic factors influencing aneurysm embolization, are also calculated. Inflow rates were smaller and the low wall shear stress zones were larger in the neck blocked models compared to the dome blocked models. Smaller inflow and larger low wall shear stress zones in the distal neck blocked model imply that the distal neck should be the effective coil locations for aneurysm embolization.

Study on Correlation with Receiving Coil and Transmitting Coil for Wireless Power Transfer at Iron Spindle (철제 스핀들에서 무선전력전송을 위한 송전기와 수전기의 상관관계 연구)

  • Lee, GiBum;Ahn, Geontae;Choi, KangHyouk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.18-19
    • /
    • 2015
  • 본 논문에서는 회전체에 붙어있는 센서에 전원을 공급하기 위하여 전자기 공진형 무선전력전송을 사용하고 있다. 회전체는 철제 스핀들로 만들어 졌으며, 스핀들 표면에 수전기를 부착하여 무선전력을 수전하고 있다. 송전기에 무선전력을 송전하고 수전기에서 전력을 수전하고자 할 때, 철제 스핀들 때문에 전력 전달효율이 감소된다. 따라서 최적의 전력전달 조건을 찾아 송전기와 수전기의 위치 및 크기를 설계하여야 한다. 본 논문에서는 송전기의 위치를 변화시키고, 수전기의 각도를 변화시키면서 송 수전기 간의 전력전달 특성을 연구하였다.

  • PDF

Design of a Wireless Intraocular Pressure Sensor Based on MEMS Technology (안압의 비접촉 검출을 위한 MEMS 기반의 센서 설계)

  • Kang, Buung-Joo;Park, Jong-Hoon;Lee, So-Hyun;Kang, Ji-Yoon;Park, Chang-Kun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.905-912
    • /
    • 2011
  • Interaocular pressure (IOP) sensor and external coil to detect the resonance frequency of the IOP sensor are designed and implemented using MEMS technology. The IOP sensor is designed using 3-D electromagnetic (EM) simulation. The resonance frequency of IOP sensor needs to be lower than that of the external coil. Additionally, the resonance frequency of the IOP sensor needs to be located near the resonance frequency of the coil to get the sufficient amplitude of phase variation. The frequency where the phase peak appears must be constant according to the distance between the IOP sensor and the external coil. From the measurement results, we demonstrated that the designed IOP sensor has the same resonance frequency with various distances between the IOP sensor and the coil.

Changes of Blood Flow Characteristics for different Coil Locations after the Embolisation of Lateral Aneurysms (측방 동맥류 색전술 후 코일 위치에 따른 혈류 유동의 변화)

  • 이계한;송계웅;변홍식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.124-127
    • /
    • 2002
  • Ceil embolisation technique has been used to treat the intracranial aneurysms. Microcoils inserted into the aneurysm sac induce the blood flow stagnation inside the aneurysm sac, which causes the thrombus formation and embolisation of aneurysm. Since the intraaneurysmal flow patterns affect the embolisation process, we want to measure the flow field for different locations of coil inside the aneurysm sac . Lateral aneurysm models are manufactured using rapid prototyping, and the velocity fields are measured using particle image velocitimeter. Distally blocked models showed less flow into the aneurysm sac comparing to proximally blocked models. Also blocking the neck of aneurysm showed better inflow blocking comparing to blocking the dome of aneurysm. These results suggest that distal neck should be the preferred locations of coil for aneurysm embolisation.

  • PDF