• 제목/요약/키워드: Cohen's Kappa

검색결과 91건 처리시간 0.028초

구내방사선사진의 인접면 치아우식 진단에 대한 유용성 평가 (The Value of Periapical Radiograph in the Diagnosis of Interproximal Caries)

  • 김영희;강병철
    • Imaging Science in Dentistry
    • /
    • 제30권1호
    • /
    • pp.49-54
    • /
    • 2000
  • Purpose : To compare the diagnostic performance of clinical and radiologic examination for the interproximal caries on intraoral periapical radiographs and to evaluate the value of periapical radiographs. Methods: One hundred seven dental patients were examined clinically, with a mouth mirror and an explorer, by a dentist at the department of oral medicine, and the presence or absence of interproximal caries lesion was recorded. The patients were prescribed one or more dental periapical radiographs. Radiographs were assessed for the presence of interproximal caries by three oral and maxillofacial radiologists independantly. Two thousand sixty interproximal surfaces were included in this study. The diagnostic accuracies of clinical and radiologic examinations for interproximal caries were calculated. To assess the degree of agreement between clinical and radiologic examinations, Cohen's coefficient of agreement was computed. Results: The specificity of clinical and radiologic examination was 0.991, 0.997 and the sensitivity was 0.279, 0.985 respectively. The diagnostic accuracy of radiologic examination was statistically significantly higher than that of clinical examination (P<0.05). Cohen's kappa value of clinical and radiologic examination was 0.335, 0.942 respectively. These results suggested that clinical examination show only fair agreement, whereas radiologic examination show perfect agreement. Conclusion: The diagnositic performance of the dental periapical radiographs on interproximal caries were higher than that of clinical examination, thus this study showed the validity of periapical radiographs for detecting interproximal caries lesion without bitewing radiograph.

  • PDF

알레르기 비염의 한의학적 분류를 위한 진단 평가지와 한의사 변증의 일치도 평가 (Assessment of Concordance Rate in Pattern Analysis between Pattern Diagnosis of KiFDA on Allergic Rhinitis in 2008 and Doctor of Korean Medicine)

  • 이규진;김희택;장보형;최인화;고성규
    • 한방안이비인후피부과학회지
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2014
  • Objective : This study aimed to assessment for concordance rate in pattern analysis between pattern diagnosis of KiFDA on allergic rhinitis in 2008 and doctor of Korean medicine. Methods : Data were obtained from 35 patients with allergic rhinitis(AR). They were asked to perform the questionnaires and had been interviewed by specialist of Korean Medicine. For correlation analysis, we used Cohen's Kappa. Results : The pattern diagnosis was done only 15 patients(42.9%). Correlation between pattern diagnosis of questionnaires and specialist showed 0.2105 in Kappa and 0.1993 in weighed Kappa. Conclusions : The result may provide the basis of modification in Pattern Diagnosis of KiFDA on allergic rhinitis in 2008.

한국과 미국 초등학교 교과서에 나타난 과학의 본성 비교 분석 (Comparative Analysis of the Presentation of the Nature of Science (NOS) in Korea and US Elementary Science Textbooks)

  • 이영희
    • 한국과학교육학회지
    • /
    • 제34권3호
    • /
    • pp.207-212
    • /
    • 2014
  • The national reform document, Science for All Americans (AAAS, 1990), and the Next Generation Science Standards (NRC, 2012) emphasize the importance of the nature of science in guiding science educators in accurately portraying science to students. Therefore, it is important that textbook materials convey an accurate conception of the nature of science. This study employs content analysis to examine the content of textbooks in US and Korea elementary science textbooks with regard to the four aspects of the nature of science: (a) nature of scientific knowledge; (b) nature of scientific inquiry; (c) nature of scientific thinking; and (d) nature of interactions among science, technology, and society (Chiappetta, Fillman, & Sethna, 2004). Intercoder reliability was determined by calculating Cohen's kappa (Cohen, 1960). Findings show that while US elementary science textbooks are not balanced in presenting the four aspects of the nature of science regardless of the publishing companies, the presentation of the nature of science in Korean elementary science textbooks have better balanced treatment of the four themes across the grade levels. On the other hand, both US and Korean elementary science textbooks are attempting to convey an idea of what science is by emphasizing scientific knowledge and investigation.

Q-Ray View 활용이 치위생과정을 위한 치아 검사의 신뢰도 향상에 미치는 영향 (The Effects of the Q-Ray View on Reliability of Assessing a Tooth Status for Dental Hygiene Process)

  • 오혜영;정회인;구혜민;김백일
    • 치위생과학회지
    • /
    • 제14권4호
    • /
    • pp.461-467
    • /
    • 2014
  • 본 연구는 치위생과 대학에서 이루어지고 있는 치위생과정 실습에서 3학년 학생들이 대상자의 치아상태를 Q-ray view를 사용하지 않고 평가한 방법과 Q-ray view를 사용하여 평가한 방법을 숙련된 검사자의 치아검사결과를 기준치로 하여 부위별, 병소 및 수복물별 일치도를 비교하였다. 부위별 차이에서 병소와 수복물은 Q-ray view를 사용한 경우에 높은 일치도를 나타냈다. 특히 상악전치부는 수복물에서 100% 정답기준과 일치하였다. 병소 및 수복물별 차이에서 Q-ray view를 사용한 경우 병소에서는 치아우식증과 초기우식증, 치아파절에서 차이가 있었고 수복물에서는 수복물 또는 치면열구전색이 없는 경우와 심미수복물에서 유의한 차이가 있었다. 본 연구의 결과 Q-ray view를 병행해서 치아검사를 수행했을 때 경험이 부족한 치위생과 학생의 치아검사 신뢰성이 향상되었다. 따라서 치위생과정 실습에서 Q-ray view는 학생의 치아검사역량 증진에 효과적인 도구로 활용될 수 있을 것이다.

화학물질사고 피해영역 산출을 위한 드론맵핑 기반의 정규식생지수 활용방안 연구 (NDVI Based on UAVs Mapping to Calculate the Damaged Areas of Chemical Accidents)

  • 임언택;정용한;김성삼
    • 대한원격탐사학회지
    • /
    • 제38권6_3호
    • /
    • pp.1837-1846
    • /
    • 2022
  • 매년 증가하는 화학사고는 유해 물질의 확산과 잔류로 인명과 환경에 피해를 주고 있다. 환경피해 조사는 지리적 조사 범위와 시기를 확정하기가 더 까다로운 측면이 있다. 전문 조사 인력이 부족한 현실을 감안할 때 효율적인 정량 평가방법의 개발이 시급하다. 본 연구는 이러한 상황의 개선을 위해 각종 센서를 장착한 드론을 활용하여 화학사고 현장 조사를 수행하였다. 화학사고로 인한 환경 피해면적은 고해상도 광학 영상을 사진측량기법을 적용하여 생성된 정사영상과 다중분광센서로 취득한 5개 분광대역 정보를 활용한 정규식생지수를 적용하여 산출되었다. 그 결과, 정규식생지수를 토대로 피해지역과 비피해지역으로 분류하고, 화학사고로 인한 피해면적에 대한 일치도를 나타내는 Kappa 상관계수는 0.649 (임계값 0.7)의 수준을 보였다. 다양한 반사특성을 가진 지형지물이 존재하는 피해 현장의 여건을 고려할 때, 분광정보와 정규식생지수만으로 피해면적을 분석이 이루어진 연구의 한계가 있으며, 향후 이를 극복할 수 있는 화학물질사고 조사 현업화 방안의 추가적인 연구가 필요할 것으로 판단된다.

건설업에서 발생하는 근골격계질환 위험요인의 작업자 자가 평가용 체크리스트 개발 (Development of a Self-Administered Checklist for Evaluation of the Musculoskeletal Disorders Risk Factors in Construction Industry)

  • 이윤근;박희석;박정근
    • 대한인간공학회지
    • /
    • 제29권5호
    • /
    • pp.811-818
    • /
    • 2010
  • In this study, a self-administered checklist for evaluation of the musculoskeletal disorders risk factors in construction industry was developed, and its reliability and validity were studied. 10 items of the checklist were determined based on the literature review, and total 2,793 construction workers participated in the analysis of the checklist's applicability. The results from the reliability analysis showed high Cohen's kappa coefficient (0.50~0.77), and high validity was also obtained in terms of relative risk (RR 1.73~9.14). Positive predictability was relatively low (13.0~32.5%), while negative predictability was high (80.1~96.8%). It can be concluded that the checklist would be suitable as a quick filtering tool of the ergonomic risk factors.

Validity of Self-reported Smoking Using Urinary Cotinine among Vocational High School Students

  • Park, Soon-Woo;Kim, Jong-Yeon
    • Journal of Preventive Medicine and Public Health
    • /
    • 제42권4호
    • /
    • pp.223-230
    • /
    • 2009
  • Objectives : This study was conducted to validate self-reported smoking among high school students using urinary cotinine. Methods : A self report of smoking behavior was collected together with urine sample for cotinine analysis from 130 male and female students in two vocational high school students in November, 2007. Validity and agreement between self-reported smoking and urinary cotinine was analyzed with STATA 9.0 for different definitions of current smokers, and frequent and daily smokers. Urinary cotinine concentration was measured by the DRI Cotinine Assay for urine (Microgenics Corp., Fremont, CA) on Toshiba 200FR. The cut-off point of urinary cotinine was 50 ng/dl. Results : The concentrations of urinary cotinine were significantly different according to the frequency and amount of smoking. Sensitivity and specificity was 90.9% and 91.8% respectively, and the Cohen s kappa value was 0.787 among the current smokers who smoked at least one day during one month preceding the survey. The comparable high sensitivity, specificity, and kappa value were shown also among the other definitions of current smokers, that is, subjective smokers, and weekly smokers. Conclusions : The results showed the high validity of self-reported smoking among high school students. However, due to the small sample size and limitation of the participants, it is cautious to generalize the results to overall high school students.

단순 방사선 검사를 이용하여 석회성 건염에서 발생하는 석회 침착물의 성상에 대한 예측이 가능한가? (Is it Possible to predict the Characteristics of Calcific Deposition in Calcific Tendinitis of Shoulder Joint?)

  • 김성재;이희제;이광현;박동혁;이봉근
    • 대한정형외과 초음파학회지
    • /
    • 제7권2호
    • /
    • pp.77-83
    • /
    • 2014
  • 목적: 본 연구의 목적은 견관절의 석회성 건염에서 발생하는 석회 침착물의 성상에 대한 기존의 단순 방사선학적 분류법들이 가지는 진단적 정밀도(precision)에 대한 평가로써, 관측자간 일치도를 평가하고, 석회 침착물의 치약형 성상 여부를 예측하는데 있어서의 진단적 정확도(accuracy)를 평가하여, 기존의 방사선학적 분류법들이 가지는 진단적 검사로써의 유용성에 대하여 평가하는 것이다. 대상 및 방법: 2010년 3월부터 2013년 9월까지 본원에서 견관절 석회성 건염으로 수술적 치료를 받은 26명 환자(26예 견관절)를 대상으로 후향적 연구를 시행하였다. 관절경하에서 관측한 석회 침착물의 성상은 총 26예 중 14예에서 분필 가루형이었고, 12예에서 치약형이었다. 수술 전 단순 견관절 방사선 검사상 나타나는 석회 침착물의 형태를 G$\ddot{a}$rtner, DePalma, Patte이 기술한 3가지 분류 체계에 따라 각각 2인의 평가자가 분석하였으며, Cohen's kappa를 이용하여 각 분류법의 관측자간 일치도를 평가하였다. 단순 방사선상에서 G$\ddot{a}$rtner 분류 III형, DePalma 분류 I형, Patte 분류 II형의 각각의 치약형 석회 침착물의 예측에 대한 민감도 및 특이도, 양성 우도비 및 음성 우도비, 그리고 진단적 승산비(diagnostic odds ratio)를 평가하였다. 치약형 석회 침착물 성상의 기준은 관절경하에서 관측한 성상을 기준으로 하였다. 결과: 단순 방사선상에서 평가한 석회 침착물의 형태에 대한 평가자간 신뢰도는 Patte 분류에서 Kappa 값이 0.62로 가장 높았고, DePalma가 0.56, G$\ddot{a}$rtner가 0.36 순이었다. 치약형 침착물을 예측하는 단순 방사선상의 침착물 형태의 민감도는 G$\ddot{a}$rtner 분류 III형, DePalma 분류 I형, Patte 분류 II형에서 각각 순서대로 83.3%, 91.7%, 58.3%였으며, 특이도는 각각 85.7%, 50.0%, 64%였다. 양성 우도비는 각각 순서대로 5.833, 1.833, 1.633였으며, 음성 우도비는 각각 0.194, 0.167, 0.648이었다. 진단적 승산비는 각각 순서대로 30.00, 11.00, 2.52이었다. 결론: 견관절의 석회성 건염에서 발생하는 석회 침착물의 성상의 예측에 대한 기존의 분류법을 이용한 평가 결과, 진단적 정밀도 및 정확도 모두에서 높은 수치를 보이는 분류법은 없었다. 따라서 추후 초음파와 같은 검사를 이용하여 석회 침착물 성상의 예측 가능 여부에 대한 추가적 연구가 필요할 것으로 생각된다.

  • PDF

한국판 정신장애 진단 선별 질문지의 표준화 연구 (Study on Standardization of Korean Version of Psychiatric Diagnostic Screening Questionnaire(K-PDSQ))

  • 최형근;정성원;조현주;김정범;정철호
    • 대한불안의학회지
    • /
    • 제9권1호
    • /
    • pp.31-37
    • /
    • 2013
  • 정신장애 진단선별 질문지(PDSQ)는 임상에서 흔하게 진단되는 DSM-IV 축 1의 장애를 평가하기위해 고안된 최초의 자기보고식 질문지이다. PDSQ는 포괄적인 평가가 가능하고, 공존질환을 평가 할 수 있으며 신뢰도와 타당도가 높은 것으로 알려져 있다. 이 연구는 K-PDSQ의 표준화를 위한 연구로서, K-PDSQ와 M.I.N.I.-Plus의 비교를 통해 K-PDSQ의 진단적 타당성과 유용성을 검증하고자 하였다. 계명대학교 동산병원 정신건강의학과를 방문한 외래와 입원환자 640명을 대상으로 K-PDSQ와 M.I.N.I.-Plus의 진단적 일치도, K-PDSQ의 시행시간, 민감도 및 특이도를 산출하였다. K-PDSQ와 M.I.N.I.-Plus의 Cohen's kappa계수는 .66로 일치도가 높게 나타났고, K-PDSQ의 시행 소요시간은 $18.2{\pm}11.80$분이었다. 타당도에 있어 국내 환자군 대상으로 산출된 절단점을 적용하였을 때 높은 수준의 민감도와 특이도를 나타냈다. 대부분의 하위척도에서 수용자 작업특성 곡선(ROC)이 대각선 위에 있었고 곡선아래 영역(AUC) 값이 .80 이상으로 선별검사로서 유용성이 입증되었다. K-PDSQ는 M.I.N.I.-Plus와 상당한 진단적 일치도를 보였고, 시행시간이 짧고, 민감도와 특이도에서 높은 수준을 보였다. 따라서 K-PDSQ는 외래 진료환경에 적용하여 임상면담 이전에 환자에 대한 진단적 평가와 공존질환을 선별해내는데 큰 도움이 될 것으로 생각된다.

Reliability of Scapular Downward Rotation Measurement in Subjects With Scapular Downward Rotation Syndrome

  • Choi, Woo-Jeong;Lee, Ji-Hyun;Jeong, Hyo-Jung;Yoon, Tae-Lim;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제21권3호
    • /
    • pp.73-79
    • /
    • 2014
  • The purposes of the current study were to (1) estimate the inter-rater agreement for visual assessment of scapular downward rotation (SDR), (2) develop the scapular downward rotation index (SDRI) as a method to measure SDR objectively and quantitatively, and (3) analyze the intra- and inter-rater reliability of the SDRI. Twenty subjects with scapular downward rotation syndrome (SDRS) were recruited for this study. The visual assessment and the measurement for the SDRI were conducted by two examiners in two sessions each. The SDRI [$(a-b){\div}a{\times}100$] is calculated with the measurement of two linear distances: One is a perpendicular distance from the root of the scapular spine to the thoracic mid-line (a), and the other is a perpendicular distance from the inferior angle of the scapula to the thoracic mid-line (b). Cohen's kappa coefficient was calculated to estimate the inter-rater agreement for visual assessment. Intra-class correlation coefficients (ICCs) with a 95% confidence interval (CI), the standard error of measurement, and minimal detectable differences were calculated to assess intra- and inter-rater reliability of SDR measurement using the SDRI. The results indicated that the kappa coefficient of inter-rater agreement for visual assessment was fair (${\kappa}=.21$). The intra-rater reliability of SDR measurement using the SDRI was excellent for examiner 1 (ICC=.92, 95% CI=.78~.97) and good for examiner 2 (ICC=.82, 95% CI=.55~.93). The inter-rater reliability was moderate (ICC=.73, 95% CI=.32~.89). These findings showed that SDR measurement using the SDRI for subjects with SDRS may be considered reliable and better than the visual assessment.