• Title/Summary/Keyword: Coefficient of temperature drop

검색결과 133건 처리시간 0.026초

전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구 (An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error)

  • 이병욱;오용택;장한솔;최성경;조효림;성원석;김은정
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

이산화탄소의 마이크로 핀관 내 상향유동 증발열전달 특성에 관한 연구 (An experimental study on heat transfer characteristics in a vertical micro-fin tube during evaporation process of carbon dioxide flowing upward)

  • 김용진;조진민;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.247-251
    • /
    • 2007
  • Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristics of carbon dioxide flowing upward in a vertical micro-fin tube have been investigated by experiment. Before a test section, a pre-heater is installed to adjust the inlet quality of the refrigerant to a desired value. The micro-fin tube with outer diameter of 5 mm and length of 1.44 m was selected as the test section. The test was conducted at mass fluxes of 318 to $530\;kg/m^2s$, saturation temperature of -5 to $5^{\circ}C$, and heat fluxes of 15 to $30\;kW/m^2$. As the vapor quality increases, the heat transfer coefficients of carbon dioxide are increased, and the heat transfer coefficients increase when the heat fluxes and saturation temperatures increase, and there was not much of influence of mass flux on the heat transfer coefficients.

  • PDF

배플수에 따른 원통다관형 열교환기 성능에 관한 실험 적 연구 (An Experimental Study of Shell and Tube Heat Exchanger Performance with Baffle Spacing)

  • 이육형;김순영;박명관
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1748-1755
    • /
    • 2001
  • The shell and tube heat exchangers were introduced to apply to a big capacity condenser and a high pressure feed water heater for power plant in the beginning of 1990s. Design and manufacturing technology fur shell and tube heat exchangers have been developed until now. But it is very difficult to calculate the expected performance characteristics of the shell and tube heat exchanger, because there are many design parameters to be considered according to internal structure and the shell side heat transfer mechanism complicately related to the design parameters. Design parameters to be considered in the design stage of shell and tube heat exchanger are shell and tube side fluids, flow rate, inlet and outlet temperature, physical properties, type of heat exchanger, outer diameter, thickness, length of tube, tube arrangement, tube pitch, permissive pressure loss on both sides, type of baffle plate, baffle cutting ratio. The propose of study is an analysis TEMA(Tubular Exchanger Manufacturers Association) E shell and tube heat exchanger performance with changing a number of baffles(3, 5, 7, 9, 11) and tubes(16, 20) and determined optimal baffle spacing.

이산화탄소의 수직원관 내 상향유동 증발열전달 특성에 관한 연구 (A study on the characteristics of evaporation heat transfer of carbon dioxide flowing upward in a vertical smooth tube)

  • 김용진;조진민;김민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2217-2221
    • /
    • 2007
  • Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristics of carbon dioxide flowing upward in a vertical tube have been investigated by experiment. Before the test section, a pre-heater is installed to adjust the inlet quality of the refrigerant to a desired value. A smooth tube with outer diameter of 5 mm and length of 1.44 m was selected as a test tube. The test was conducted at mass fluxes of 212 to 530 kg/$m^2s$, saturation temperature of -5 to 20$^{\circ}C$, and heat fluxes of 20 to 45 kW/$m^2$. As the vapor quality and mass fluxes increase, the heat transfer coefficients of carbon dioxide are decreased, and the heat transfer coefficients increase when the heat fluxes and saturation temperatures increase.

  • PDF

CO2 압축기의 운전조건과 오일토출의 상관분석에 관한 실험적 연구 (An Experimental Study on Correlation between Oil Discharge and Various Operating Conditions of a CO2 Compressor)

  • 이익수;강병하
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 2011
  • A portion of oil for lubrication of compressor flows together with refrigerant in the refrigeration system. If the oil discharge from a compressor is increased in the refrigeration system, not only pressure drop is increased in other components, such as evaporator and gas cooler, but also heat transfer coefficient in the heat exchangers is decreased. Oil discharge rate from a compressor may strongly depend on operating conditions of a compressor. In this study, one stage single rotary compressor is employed for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Oil circulation ratio(OCR) can be estimated by measured mixture density. The results obtained indicate that the oil circulation ratio(OCR) is increased as the suction temperature or compressor operating frequency is increased. Oil circulation ratio(OCR) correlation of the compressor is also suggested.

격자형 충진물을 이용한 충진탑내 기액상의 역류에 의한 물질전달과 수력학적 동특성 (Mass Transfer and Hydraulic Kinematic Character Using Lattices Packings by Countercurrent Flow of Gas-Liquid Phase in Packing Column)

  • 김장호;하상안
    • 한국해양공학회지
    • /
    • 제2권2호
    • /
    • pp.130-137
    • /
    • 1988
  • This thesis introduced that character of a treatment technique for a mading synthetic resin Hifiow-Ring. The material system of packings make an experiment air$NH_{3}$/air$H_{2}SO_{4}$, $SO_{2}$-air/NaOH, $NH_{3}$-air/$/H_{2}SO_{4}$ under general conditions. Lattices packing compared with conventional packings was proved low pressure loss and high separation efficiency for high loading per trans unit. And an inflow materal tested for absorption and rectification, it made an experiment under a range regular temperature, low energy and small amount of money. That made possible in simple equation, volume material tranfer coefficient$\beta_{L}$ . a by absorption or $\beta_{V}$ .a calculated in all range loading. The peculiarity pressure loss $\Delta\;P/NUT_{ov}$ for Hiflow-ring contributed to a fall cost of energy, a grade number of a vacuum rectification and absorption calculation.

  • PDF

거친 사각채널에서 열전달과 유체유동 특성에 관한 실험 및 수치해석 (Experimental and Numerical Investigation on Heat Transfer and Fluid Flow Characteristics in the Ribbed Square Channel)

  • 강호근;배성택;이대희;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.275-283
    • /
    • 2006
  • Experiment and three dimensional numerical investigations of incompressible turbulent flow through square channels with one- and two-sided ribbed walls are performed to determine pressure drop and heat transfer. The CFX(version 5.7) software package is used for the computation. The ribbed walls have a $45^{\circ}$ inclined square rib. Uniform heat flux is maintained on whole inner heat transfer channel area. The numerical results coincide with experimental data that obtained for $7,600{\le}Re{\le}24.900$, the pitch-to-rib height ratio (p/e) of 8.0. and the rib height-to-channel hydraulic diameter ratio ($e/D_h$) of 0.0667. The results show that values of local heat transfer coefficient and friction factor in the channel with two-sided ribbed wall are higher than those in the channel with one-sided ribbed walls.

휜 타입 내부열교환기 적용에 따른 차량용 냉방시스템 성능 특성 (Performance Characteristics of Vehicle Air Conditioning System Using Internal Heat Exchanger with Inner Fin)

  • 김성철
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.69-73
    • /
    • 2013
  • 내부열교환기를 이용한 에어컨 시스템은 작동유체인 R134a의 고압측 액상냉매와 저압측 기상냉매의 상호 열교환을 통해 시스템의 응축 효율을 증가시켜 에너지 효율을 개선시킨다. 이는 에어컨 시스템의 성능 향상 및 경량화를 가능하게 하여 차량 연비 향상과 냉매 누출을 최소화할 수 있으며, 또한 현 R134a 대비 대체냉매 (R1234yf 등)의 동등 냉방성능 확보를 가능하게 하는 기술이다. 본 연구에서는 내측 압출 파이프 및 외측 사이 고효율 냉각 휜 (fin)이 삽입된 이중관 형태의 내부열교환기 상세 설계를 위해, 냉각 휜의 높이 및 내측 압출 파이프 내부형상 등의 다양한 형상 설계인자 변경에 따른 열전달 성능 및 압력강하 특성을 살펴보았다. 가장 우수한 내부열교환기 성능은 난류형성을 위한 내측관 형상이 라이너 및 세레이션 겸용 타입이었으며, 이는 내부열교환기가 장착되지 않은 경우보다 냉방시스템 성능이 약 6.4%, 시스템 COP는 약 9.2% 향상된 결과를 나타내었다.

수평평활 세관 내에서의 R-290, R-600a, R-22의 응축열전달과 압력강하 특성 (Condensation Heat Transfer Characteristics and Pressure Drop of R-290, R-600a, and R-22 in Horizontal Smooth Pipes with a Small Diameter)

  • 노건상;손창효
    • 청정기술
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2008
  • 본 연구에서는 내경이 각각 5.80 mm와 10.07 mm인 두 개의 수평 이중관열교환기 내에서의 탄화수소계 냉매의 응축열전달과 압력강하에 대한 실험을 $35.5{\sim}210.4\;kg/m^2\;s$의 질량유속과 응축온도인 $40^{\circ}C$에서 수행하였다. 탄화수소계 냉매 R-290과 R-600a의 응축열전달계수가 프레온계 냉매인 R-22보다 높았다. 응축압력강하는 R-600a > R-290 > R-22 순으로 나타났고, 내경이 5.8 mm인 관 내 보다 10.07 mm인 관 내의 압력강하가 R-600a에서는 $6{\sim}15%$ 정도 높았으며, R-290과 R-22에서는 각각 $9.8{\sim}12.5%$$2.1{\sim}4.6%$ 정도 높게 나타났다. 실험으로 구한 응축열전달계수와 종래의 상관관계식을 비교해 본 결과, 모든 관경에 대해 Haraguchi 등의 상관관계식과 가장 좋은 일치를 보였다.

  • PDF

대체냉매 R-32(Difluoromethane)의 열역학적 물성과 R-22 대체냉매로서 열역학적 성능의 초기 평가 (Thermodynamic Properties of R-32(Difluoromethane) and Initial Evaluation of Thermodynamic Perfomance as A R-22 Alternative Refrigerant)

  • 박영무
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.141-155
    • /
    • 1993
  • Thermodynamic properties of R-32 are calculated and its refrigeration performance is evaluated for the purpose the feasibility study of replacing R-22 with R-32. (1) Refrigeration effect of R-32 is superior to that of R-22 because heat of evaporation of R 32 is about 50% higher than that of R-22. However, COP of R-32 system is 10-30% lower than that of R-22 system. It is mainly attributed to the vapor pressore of R-32 being about 62% higher than R-22. (2) Since the pressure ratio and the specific heat ratio of R-32 system is higher than those of R -22, compressor discharging temperature rises as high as to $130-150^{\circ}C$. It may cause mechanical failure of compressor due to the breakdown of lubricant. Compressor should be improved to lower the temperature if R-32 is to replace R-22. (3) Averaged two-phase heat transfer coefficient of R-32 is about 10-20% higher than that of R-22. It may assume better heat exchanger effectiveness but not guarantee the better COP of R-32 system than R-22. (4) The high vapor pressure is the first reason to drop R-32 out of the line of R-22 alternative refrigerant. So, refrigerant mixtures based on R-32 are recommended to adjust the vapor pressure first and keep superior volumetric capacity of R-32.

  • PDF