• Title/Summary/Keyword: Code injection

Search Result 310, Processing Time 0.029 seconds

Numerical Study for Spray Characteristics of Liquid Jet in Cross Flow with Variation of Injection Angle (분사각 변화에 따른 횡단류에 분사되는 액체제트의 분무특성에 대한 수치적 연구)

  • Lee Kwan-Hyung;Ko Jung-Bin;Koo Ja-Ye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.161-169
    • /
    • 2006
  • The spray characteristics of liquid jet in cross flow with variation of injection angle are numerically studied. Numerical analysis was carried out using KIVA code, which was modified to be suitable for simulating liquid jet ejected into cross flow. Wave model and Kelvin-Helmholtz(KH)/Rayleigh-Taylor(RT) hybrid model were used for the purpose of analyzing liquid column, ligament, and the breakup of droplet. Numerical results were compared with experimental data in order to verify the reliability of the physical model. Liquid jet penetration length, volume flux, droplet velocity profile and SMD were obtained. Penetration length increases as flow velocity decreases and injection velocity increases. From the bottom wall, the SMD increases as vertical distance increases. Also the SMD decreases as injection angle increases.

Analysis of Behavior Characteristics of Common Rail System Injector for the Variations of Injector Parameters (커먼 레일 시스템 인젝터의 파라미터 변화에 따른 거동특성 해석)

  • Kim, Joong-Bae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.5
    • /
    • pp.499-508
    • /
    • 2009
  • This paper focuses on the modelling of common rail diesel injector using the AMESim code and shows the appropriateness of the developed model. For the developed injector model, simulations are carried out to analyze the behavior characteristics of the injector for the variations of injector model parameters such as orifice diameters, rail pressures, and energizing times. Simulation results show that the diameters of inlet and outlet orifices have close relation with injection quantity. Increment of rail pressure and energizing time provides increment of injection quantity, and simulated energizing time map shows injection characteristics of the common rail injector.

Numerical Simulation of Flow-Induced Birefringence: Comparison of Injection and Injection/Compression Molding

  • Lee, Ho-Sang;Isayev, A.I.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.66-72
    • /
    • 2007
  • A computer code was developed to simulate the filling stage of an injection/compression molding process using a finite element method. The constitutive equation was the compressible Leonov model and the PVT relationship was assumed to follow the Tait equation. The flow-induced birefringence was related to the calculated flow stresses through the linear stress-optical law. Simulations of a disk under different processing conditions, including variations of the compression stroke and compression speed, were performed to determine their effects on the flow-induced birefringence. Simulated pressure traces were also compared to those obtained in conventional injection molding and with experimental data from the literature.

CFD Simulation of SMD Distribution of Diesel Sprays Injected from a Common Rail Injector According to Compression Ratio of Combustion Chamber (커먼레일 인젝터로부터 분사되는 디젤 분무의 연소실 압축비 변화에 따른 SMD 분포의 CFD 시뮬레이션)

  • Lee, Choong Hoon
    • Journal of ILASS-Korea
    • /
    • v.19 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • A diesel spray overall SMD (Sauter mean diameter) in a spray chamber was simulated with CFD by varying the compression ratio in the spray chamber from 18:1 to 100:1. The gas densities of the spray chambers for the compression ratios of 18:1 and 100:1 were 17.97 and $74.8kg/m^3$, respectively. Standard KIVA-3V code was used for the CFD simulation. Various fuel injection patterns such as single injection, pilot injection and split injection were used for the CFD simulation. Fuel injection pressures for the simulated diesel sprays are 90 and 120 MPa. As the compression ratio increases, the CFD simulated SMD was decreased, which was generally in agreement with previous experimental studies.

DETAILED EVALUATION OF THE IN-VESSEL SEVERE ACCIDENT MANAGEMENT STRATEGY FOR SBLOCA USING SCDAP/RELAP5

  • Park, Rae-Joon;Hong, Seong-Wan;Kim, Sang-Baik;Kim, hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.7
    • /
    • pp.921-928
    • /
    • 2009
  • As part of an evaluation for an in-vessel severe accident management strategy, a coolant injection into the reactor vessel under depressurization of the reactor coolant system (RCS) has been evaluated in detail using the SCDAP/RELAP5 computer code. A high-pressure sequence of a small break loss of coolant accident (SBLOCA) has been analyzed in the Optimized Power Reactor (OPR) 1000. The SCDAP/RELAP5 results have shown that safety injection timing and capacity with RCS depressurization timing and capacity are very effective on the reactor vessel failure during a severe accident. Only one train operation of the high pressure safety injection (HPSI) for 30,000 seconds with RCS depressurization prevents failure of the reactor vessel. In this case, the operation of only the low pressure safety injection (LPSI) without a HPSI does not prevent failure of the reactor vessel.

Verification and Hydraulic Model Development of 3rd Generation Piezo Injector for CRDi System in Passenger Vehicle (승용CRDi용 3세대 피에조 인젝터 유압해석모델 개발 및 검증)

  • Jo, Insu;Jeong, Myoungchul;Lee, Jinwook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.181-187
    • /
    • 2013
  • Performance of DI diesel engine with high fuel injection method is directly related to its emission characteristics and fuel consumption. In this study, numerical model of 3rd generation piezo-driven injector was designed to analyze the hydraulic performance. Also the injection response characteristics was investigated by using the AMESim simulation code. From this study, it was shown that 3rd generation piezo-driven injector had a faster response and had better control capability due to its hydraulic bypass-circuit that has potential to higher hydraulic characteristics and improved accuracy of injected fuel quantity.

Transient Flow Analyses of the Intake and Compression Processes In a Direct Injection Engine (직분식 디젤엔진의 흡입$\cdot$압축 행정시 엔진 실린더 내의 비정상 유동 해석)

  • Joo K. J.;Park H. K.
    • Journal of computational fluids engineering
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2002
  • The transient flow fields in a direct injection engine was analyzed by using the STAR-CD CFD code doting the intake/compression processes. The analyses were focused on the computation grid generation by using the IC3M code which is a pre-developed and especially well adapted for the analyses of internal combustion engine. The results showed that the used grid generation technique was well suited for the flow analyses on any internal combustion engine.

Transient Flow Analyses of the Intake and Compression Processes In Direct Injection Engines (직분식 디젤엔진의 흡입$\cdot$압축 행정시 엔진 실린더 내의 비정상 유동 해석)

  • Joo K. J.;Park H. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63-69
    • /
    • 2001
  • The transient flow fields in direct injection engines were analyzed by using the STAR-CD CFD code during the intake/compression processes. The analyses were focused on the computation grid generation by using the IC3M code which is a pre-developed and especially well adapted for the analyses of internal combustion engines. The results showed that the used grid generation technique was well suited for the flow analyses on any internal combustion engines.

  • PDF

Improvement of Direct Contact Condensation Model of RELAP5/MOD3.1 for Passive High-Pressure Injection System

  • Lee, Sang-Il;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.368-373
    • /
    • 1996
  • A simple set of the transition criterion of the condensation regimes and the heat transfer coefficients on the direct contact condensation of the core makeup tank is developed, and implemented in RELAP5/MOD3.1 The condensation regimes are divided into two regimes: supply limit and condensation limit. In mode]ing the transition criterion between two regimes, a large-eddy model developed by Theofanous is used, and the empirical coefficient of the present large-eddy model is close to that of the large-eddy model. It turns out that the modified code better predicts the experimental data, especially the injection flow rate and the water level trend than the original code does.

  • PDF

Investigation of Separated Injection of Air and Argon in Segmented Constrictor Type Arc Heaters (세그먼트 아크히터 내부에서 공기와 아르곤 기체의 혼합 현상에 대한 연구)

  • Lee, Jeong-Il;Jeong, Ga-Ram;Kim, Kyu-Hong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.197-200
    • /
    • 2008
  • The existing computer code to solve the air flow in a segmented constrictor-type arc-heated wind tunnel named ARCFLO4 is improved to accept an air-argon mixture as the working gas and to consider the separated injection of air and argon. The new version of the code is used to calculate the flows in the Aerodynamic Heating Facility of NASA Ames Research Center where argon concentration is relatively high. The calculation shows that argon tends to increase the diameter of the arc-column, increase ionization fraction, decrease thermal efficiency of the arc-heater, and push the ratio of the centerline-to-average enthalpy toward unity. The calculated operating characteristics of the arc-heater agree well with the experimental data.

  • PDF