• Title/Summary/Keyword: Coaxial Air

Search Result 110, Processing Time 0.025 seconds

Combustion characteristics of coaxial diffusion flame with high preheated and swirled air (고온 공기와 선회수에 의한 동축 분류 화염의 연소 특성)

  • Kim, Jin-Sik;Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.112-117
    • /
    • 2001
  • An experiment using high preheated and swirled air in the coaxial diffusion flame burner was carried out in order to decrease NOx emission and improve the thermal efficiency. $N_2$ gas was used for diluent and propane was utilized for fuel. Combustion using high preheated air has two remarkable characteristics ; (1) low NOx emission with increasing dilution level, (2) high thermal efficiency in the furnace. Also, swirled air can mix fuel and oxidizer well in condition of diffusion flme and maintain the stable combustion. The color of flame changes from yellow to blue green according to increasing the dilution level of mixture gas. NO emission decreased with increasing dilution level and the swirl number.

  • PDF

Stability of Attached Flame in $H_2$/CO Syngas Non-premixed Turbulent Jet Flame ($H_2$/CO 합성가스 비예혼합 난류 제트화염에서 부착화염의 화염안정화)

  • Hwang, Jeong-Jae;Bouvet, Nicolas;Sohn, Ki-Tae;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.22-29
    • /
    • 2012
  • The detachment stability characteristics of syngas $H_2$/CO jet attached flames were studied. The flame stability was observed while varying the syngas fuel composition, coaxial nozzle diameter and fuel nozzle rim thickness. The detachment stability limit of the syngas single jet flame was found to decrease with increasing mole fraction of carbon monoxide in the fuel. In hydrogen jet flames with coaxial air, the flame detachment stability was found to be independent of the coaxial nozzle diameter. However, velocities of appearance of liftoff and blowout velocities of lifted flames have dependence. At lower fuel velocity range, the critical coaxial air velocity leading to flame detachment increases with increasing fuel jet velocity, whereas at higher fuel velocity range, it decreases. This increasing-decreasing non-monotonic trend appears for all $H_2$/CO syngas compositions (50/50~100/0% $H_2$/CO). To qualitatively understand the flame behavior near the nozzle rim, $OH^*$ chemiluminescence imaging was performed near the detachment limit conditions. For all fuel compositions, local extinction on the rim is observed at lower fuel velocities(increasing stability region), while local flame extinction downstream of the rim is observed at higher fuel velocities(decreasing stability region). Maximum values of the non-monotonic trends appear to be identical when the fuel jet velocity is normalized by the critical fuel velocity obtained in the single jet cases.

Nitrogen Dilution Effects on Liftoff Flame Stability in Non-premixed Turbulent Hydrogen Jet with Coaxial Air (질소희석이 부상된 수소 난류확산화염의 화염안정성에 미치는 영향)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.393-396
    • /
    • 2008
  • The study of nitrogen dilution effect on flame stability was experimentally investigated in non-premixed turbulent lifted hydrogen jet with coaxial air. hydrogen gas was used as a fuel and coaxial air was injected to make flame liftoff. And both of the fuel jet and coaxial air velocity were fixed as $u_F$=200 m/s and $u_A$=16 m/s, while nitrogen diluents mole fraction was varied from 0 to 0.2. For the analysis of flame structure and flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF had been performed. It was found that the turbulent flame propagation velocity increased as decreasing of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity, even though the mole fraction of nitrogen diluents gas was changed.

  • PDF

Flame Structure of a Liftoff Non-Premixed Turbulent Hydrogen Jet with Coaxial Air (부상된 수소 난류확산화염의 화염구조)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.9
    • /
    • pp.699-708
    • /
    • 2009
  • To understand hydrogen jet liftoff height, the stabilization mechanism of turbulent lifted jet flames under non-premixed conditions was studied. The objectives were to determine flame stability mechanisms, to analyze coexistence of two different flame structure, and to characterize the lifted jet at the flame stabilization point. Hydrogen flow velocity varied from 100 to 300 m/s. Coaxial air velocity was changed from 12 to 20 m/s. Simultaneous velocity field and reaction zone measurements used, PIV/OH PLIF techniques with Nd:YAG lasers and CCD/ICCD cameras. Liftoff height decreased with the increase of fuel velocity. The flame stabilized in a lower velocity region next to the faster fuel jet due to the mixing effects of the coaxial air flow. The flame stabilization was related to turbulent intensity and strain rate assuming that combustion occurs where local flow velocity and turbulent flame propagation velocity are balanced. At the flame base, two different flame structures were found that was the partial premixed flames and premixed flame.

A Study on the Flow Characteristics in Double Coaxial Pipe Jets (동축이중원관 분류에 있어서의 유동 특성에 관한 연구)

  • Shin, C.H.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.1 no.4
    • /
    • pp.46-53
    • /
    • 1996
  • The present study is aiming at improving the performance of main nozzle of an air jet loom with a modified reed and auxiliary nozzles. The double coaxial pipe jets consisting of a central air jet and an annular air jet have been experimentally investigated. The duter jet has a potential core and a constant velocity. The inner jet through an inner long pipe is induced by the subatmospheric pressure near the inner nozzle edge, and the jet velocity of an inner pipe is always lower than that of a outer pipe. The static pressures of the main nozzle over a wide range of the nozzle tank pressure were measured, and the nozzle velocity and Mach numbers were analytically calculated. Experiment81 results indicate that the critical condition of Mach number of unity to occur at the two positions in a main nozzle; one of them is the needle tip and the other is the acceleration tube exit An increase in the tank pressure causes the critical throat condition to occur at the two positions above. The velocity of acceleration-tube exit is maximum at the critical length L* and flow patter in acceleration-tube over critical lengh remains unstable.

  • PDF

Effect of Gas Density on Self-Pulsation in Liquid-Gas Swirl Coaxial Injector (액체-기체 와류동축형 분사기의 자기-맥동에 대한 기체 밀도의 영향)

  • Ahn, Jonghyeon;Kang, Cheolwoong;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.134-143
    • /
    • 2022
  • When a recess is applied to a swirl coaxial injector that uses liquid and gas propellants, a self-pulsation phenomenon in which the spray oscillates at regular intervals may occur. The phenomenon is caused by the interaction between the liquid and gas propellants inside the injector recess region. The propellants' kinetic energies are expected to affect significantly the spray oscillation. Therefore, cold-flow tests using helium as a gas-simulating propellant were conducted and compared with the results of the previous study using air. Dynamic pressure was measured in the injector manifold and frequency characteristics were investigated through the fast Fourier transform analysis. In the experimental environment, the helium density was about seven times lower than the air density. Accordingly, the intensity of pressure fluctuations was confirmed to be greater when air was used. At the same kinetic energy condition, the perturbation frequency was almost identical in the low flow rate conditions. However, as the flow rate increased, the self-pulsation frequency was higher when helium was used.

Precise Impedance Measurement of Coaxial Loads using Air Line Impedance Standards (Air Line 임피던스 표준을 이용한 동축형 부하의 임피던스 정밀 측정)

  • 강진섭;김정환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.788-795
    • /
    • 2000
  • In this paper, a method for the precise impedance measurement of coaxial loads using an offset open and short as the reflection standards and reference air lines with different lengths as the impedance standards is proposed. Measured input impedances of power sensors and thermistor mounts obtained from SWR bridges(5~400MHz) and a vector network analyzer(100~1,000MHz) are presented in the frequency range of 5MHz to 1,000 MHz.

  • PDF

The Natural Frequency of a Coaxial Cylindrical Shell with Fluid Coupling (유체 연성이 작용하는 동축 원통형 쉘의 고유진동)

  • 안병준;정경훈;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.975-979
    • /
    • 1994
  • The experimental and finite element studies of a coaxial cylindrical shell filled with liquid in the annular gap were performed to understand its vibration characteristics. Finite element analysis was achieved by using ANSYS code. Form the investigation of the changing trend of natural frequencies for the change of annular gap we know that the natural frequency of the coaxial cylindrical shell varies according to the mode shape. that is, in case of in-phase mode the natural frequency decrease as annular gap increase, but in case of out-of-phase mode the natural frequency increase. Finite element analysis results show the excellent agreement with the experimental results both in air and in water case, so that analysis on other cases with be possible without experiment.

  • PDF

An Experimental Study on Flame Structure and Combustion Characteristics of Turbulent Diffusion Flame(I) (난류확산화염의 화염구조와 연소특성에 관한 실험적 연구)

  • Choe, Byeong-Ryun;Jang, In-Gap;Choe, Gyeong-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1028-1039
    • /
    • 1996
  • This study was focused on the examination of the flame structure and the combustion characteristics of diffusion flame which was formed the turbulent shear flow of a double coaxial air jet system. The shear flow was formed by the difference velocity of surrounding air jet(U$\_$s/) and center air jet (U$\_$c/). So experimental condition was divided S-type flame (.lambda. > 1) and C-type flame (.lambda. < 1) by velocity ratio .lambda. (=U$\_$s//U$\_$c/). For examination of the flame structure and the combustion characteristics in diffusion flame, coherent structure was observed in flame by schlieren photograph method. We measured fluctuating temperature and ion current simultaneously and accomplished the statistical analysis of its. According to schlieren photograph, the flame was stabilized in the rim of the direction of lower velocity air jet, coherent eddy was produced and developed by higher velocity air jet. The statistical data of fluctuating temperature and ion current was indicated that reaction was dominated by higher velocity air jet. The mixing state of burnt gas and non-burnt gas was distributed the wide area at Z = 100 mm of C-type flame.

The Effect of Turbulence Intensity on the NOx Formation of Hydrogen Coaxial Jet Turbulent Diffusion Flames (난류강도가 수소 동축분류 난류 확산화염의 NOx 생성에 미치는 영향)

  • Han, Ji-Ung;Jeong, Yeong-Sik;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.147-155
    • /
    • 2001
  • Experimental investigations were conducted for two hydrogen-nitrogen coaxial jet diffusion flames. A flame was a conventional coaxial jet diffusion flame and the other was a coaxial jet diffusion flame of which ambient air-jet turbulence was intensified. In this study, firstly two kinds of NOx measuring system were campared by using different convertors, secondly the NOx formation characteristics were investigated in order to examine the effect of turbulence intensity. In this study it is known that stainless convertor has some problem in the converting process from NO$_2$to NO in fuel rich region but molybdenum convertor can detect the amount of NOx correctly. The increase of turbulence intensity reduces the thermal NOx less than a half in our experiment and this effect is conspicuous near the nozzle. The conversion rate from NO to NO$_2$and the portion of NO$_2$among NOx are increased with turbulence intensity. These NOx measurements will help to understand the influences of turbulence intensity on NOx formation.