• Title/Summary/Keyword: Coal-fired Power Plant

Search Result 262, Processing Time 0.023 seconds

여과식 채취방법에 의한 대기오염 총침착물의 특성 -석탄화력발전소 주변지역을 중심으로- (Characteristics of Total Atmospheric Deposition by the Filtration-Sampling Method at Coal-Fired Power Plant Area)

  • 박정호;조인철;최금찬
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.161-170
    • /
    • 2002
  • Total(=wet+dry) atmospheric depositions were collected by filtration-sampling method at 17 sampling sites of the coal-fired power plant area from September 1999 to January 2000. The soluble and insoluble fractions of deposition were also measured to investigate a suitability of simplified collection method for a long-term monitoring of total deposition. In the study, the 50% of sampled soluble fractions showed the electric conductivity (E.C.) of below 50 $\mu$S/cm and the 42% of them showed the lower pH than 5.0. The monthly mean fluxes of water soluble ionic components; S $O_4$$^{2-}$, C $l^{[-10]}$ , N $O_3$$^{[-10]}$ , N $a^{+}$, N $H_4$$^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$ were 168.4 kg/k $m^2$.month, 100.5 kg/k $m^2$.month, 88.6kg/k $m^2$.month, 31.3kg/k $m^2$.month, 25.6 kg/k $m^2$.month, 13.3 kg/k $m^2$.month, 8.7 kg/k $m^2$.month, 43.1kg/k $m^2$.month, respectively. The mean ionic concentration of all sample(n=79) was 314 $\mu$eq/ι, with contributions of 24.2% and 23.0% by [nss-C $a^{2+}$] and [nss-S $O_4$$^{2-}$]. The ratio of [N $O_3$$^{[-10]}$ ]/[nss-S $O_4$$^{2-}$] and [N $H_4$-C $a^{2+}$] were found to be 0.52 and 0.68, respectively.espectively.

미세입자(PM2.5)의 배출원 구성물질 성분비 개발에 관한 연구 (A Study on the Development of Source Profiles for Fine Particles (PM2.5))

  • 이학성;강충민;강병욱;이상권
    • 한국대기환경학회지
    • /
    • 제20권3호
    • /
    • pp.317-330
    • /
    • 2004
  • The Purpose of this study was to develop the P $M_{2.5}$ source Profiles, which are mass abundances (fraction of total mass) of a chemical species in P $M_{2.5}$ source emissions. The source categories studied were soil, road dust, gasoline and diesel vehicles, industrial source, municipal incinerator, coal-fired power plant, biomass burning, and marine. The chemicals analyzed were ions. elements. and carbons. From this study, soil source had the crustal components such as Si, hi, and Fe. In the case of road dust. Si, OC, Ca, Fe had large abundances. The abundant species were S $O_4$$^{2-}$, C $l^{[-10]}$ , N $H_4$$^{+}$, and EC in the gasoline vehicle and EC, OC, C $l^{[-10]}$ , and S $O_4$$^{2-}$ in the diesel vehicle. The main components were S $O_4$$^{2-}$, S N $H_4$$^{+}$, and EC in the industrial source using bunker C oil as fuel, C $l^{[-10]}$ , N $H_4$$^{+}$, Fe, and OC in the municipal incinerator source, and Si, Al, S $O_4$$^{2-}$, and OC in the coal -fired power plant source. In the case of biomass burning, OC, EC, and C $l^{[-10]}$ were mainly emitted. The main components in marine were C $l^{[-10]}$ , N $a^{+}$, and S $O_4$$^{2-}$.EX> 2-/.

Natural radioactivity level in fly ash samples and radiological hazard at the landfill area of the coal-fired power plant complex, Vietnam

  • Loan, Truong Thi Hong;Ba, Vu Ngoc;Thien, Bui Ngoc
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1431-1438
    • /
    • 2022
  • In this study, natural radioactivity concentrations and dosimetric values of fly ash samples were evaluated for the landfill area of the coal-fired power plant (CFPP) complex at Binh Thuan, Vietnam. The average activity concentrations of 238U, 226Ra, 232Th and 40K were 93, 77, 92 and 938 Bq kg-1, respectively. The average results for radon dose, indoor external, internal, and total effective dose equivalent (TEDE) were 5.27, 1.22, 0.16, and 6.65 mSv y-1, respectively. The average emanation fraction for fly ash were 0.028. The excess lifetime cancer risks (ELCR) were recorded as 20.30×10-3, 4.26×10-3, 0.62×10-3, and 25.61×10-3 for radon, indoor, outdoor exposures, and total ELCR, respectively. The results indicated that the cover of shielding materials above the landfill area significantly decreased the gamma radiation from the ash and slag in the ascending order: Zeolite < PVC < Soil < Concrete. Total dose of all radionuclides in the landfill site reached its peak at 19.8 years. The obtained data are useful for evaluation of radiation safety when fly ash is used for building material as well as the radiation risk and the overload of the landfill area from operation of these plants for population and workers.

Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang Doo;Kim, Yi-Gon;Lee, Bong Kuk;Bae, Young Chul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권2호
    • /
    • pp.187-192
    • /
    • 2004
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experimental results of the simulation.

경량골재 로타리킬른의 운전최적화를 위한 석탄연소 및 원료입자 승온특성 해석 (Analysis of Coal Combustion and Particle Temperature Profiles in a Rotary Kiln for Production of Light-weight Aggregate)

  • 박종근;류창국;김영주
    • 한국연소학회지
    • /
    • 제19권3호
    • /
    • pp.18-25
    • /
    • 2014
  • Bottom ash from a coal-fired power plant is usually landfilled to a nearby site, which causes a growing environmental concern and increased operating costs. One way of recycling the bottom ash is to produce light-weight aggregate (LWA) using a rotary kiln. This study investigated the temperature profiles of raw LWA particles in a rotary kiln to identify the range of operating conditions appropriate for ideal bloating. For this purpose, a new simulation method was developed to integrate a 1-dimensional model for the bed of LWA particles and the computational fluid dynamics (CFD) for the fuel combustion and gas flow. The temperature of LWA particles was found very sensitive to the changes in the air preheating temperature and excess air ratio. Therefore, an accurate control of the operation parameters was essential to achieve the bloating of LWA particles without excessive sintering or melting.

Application of Cathodic Protection on Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권4호
    • /
    • pp.140-146
    • /
    • 2005
  • Fossil fired power plant produces the electric energy by using a thermal energy by the combustion of fossil fuels as like oil, gas and coal. The exhausted flue gas by the combustion of oil etc. contains usually many contaminated species, and especially sulfur-content has been controlled strictly and then FGD (Flue Gas Desulfurization) facility should be installed in every fossil fired power plant. To minimize the content of contaminations in final exhaust gas, high corrosive environment including sulfuric acid (it was formed during the process which $SO_2$ gas combined with $Mg(OH)_2$ solution) can be formed in cooling zone of FGD facility and severe corrosion damage is reported in this zone. These conditions are formed when duct materials are immersed in fluid that flows on the duct floors or when exhausted gas is condensed into thin layered medium and contacts with materials of the duct walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of those ducts. The frequent shut down and repairing works of the FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, corrosion problems have severely occurred in a cooling zone even though high corrosion resistant materials were used. In this work, a new technology has been proposed to solve the corrosion problem in the cooling zone of FGD facility. This electrochemical protection system contains cathodic protection method and protection by coating film, and remote monitoring-control system.

국내 석탄재 재활용 확대 방안 연구 (Studies on Expanding Application for the Recycling of Coal Ash in Domestic)

  • 조한나;맹준호;김은영
    • 환경영향평가
    • /
    • 제26권6호
    • /
    • pp.563-573
    • /
    • 2017
  • 매년 화력발전소에서 약 800톤이상 되는 석탄재가 발생되고 있다. 발생되는 석탄재 중 재활용되고 남은 석탄재는 회처리장에 매립되고 있다. 현재 회처리장 용량에는 한계가 있고, 석탄재 매립으로 인한 환경영향의 우려로 회처리장 신규 확보도 어려운 상황이다. 환경영향 최소화라는 측면에서 석탄재 재활용 및 유효이용이 향후 장기적 국가적으로 시급하게 해결해야 할 문제로 인식되고 있다. 따라서, 본 연구는 국내 석탄재 재활용 확대를 가로막고 있는 문제점을 분석하여 해외 사례를 바탕으로 친환경적 국토관리와 자원순환사회를 위한 석탄재 재활용 확대 방안을 제안 하고자 하였다. 국내 석탄재 재활용 확대 방안은 다음과 같다. 첫째, 석탄재를 재활용 할 수 있는 법적 근거를 마련하는 것이다. 이를 위해서는 환경성 예측 평가에 대한 기법과 기준 및 체계 개발이 필요하다. 둘째, 이해관계자들의 인식 전환을 유도하는 것이다. 석탄재의 환경 안전성에 대한 연구 및 홍보가 필요하며 이해관계자들의 적극적인 의사소통 및 정보 제공이 필요하다. 셋째, 석탄재 재활용을 활성화 할 수 있는 실제적인 지원방안이 필요하다. 정책방안으로는 석탄재 처리비 지원, 석탄재 공급센터 설치 등이 있다.

탄소세 변화에 따른 IGCC와 이산화탄소 저감기술 진입경쟁력 및 온실가스 저감효과 분석 (A Study on Competitiveness and GHG Mitigation Effect of IGCC and Carbon Capture Technology According to Carbon Tax Change)

  • 전영신;김영창;김형택
    • 에너지공학
    • /
    • 제17권2호
    • /
    • pp.54-66
    • /
    • 2008
  • 2005년 2월 16일 발효된 교토의정서 체제에서 부속서 I 에 포함된 선진국들은 온실가스에 대하여 2008년부터 2012년까지 연간 1990년 대비 년 평균 5.2%를 감축하도록 목표량을 규정하였다. 이러한 목표량을 달성하기 위하여 EU등의 국가는 배출권 거래제도 및 청정개발체제(CDM)사업 등 온실가스를 저감하기 위하여 힘쓰고 있다. 교토-의정서 1차 공약기간 중에서 온실가스 감축목표를 부여받지 않은 OECD국가는 우리나라와 멕시코 두 나라 뿐이며, 이산화탄소 배출량 9위인 우리나라에 2차 공약기간(2013년$\sim$2017년)부터 의무저감에 대한 국제적 압력이 가중되고 있다. 본 연구에서는 탄소세를 변화시키면서 발전소 건설의 변화와 그에 따른 $CO_2$ 저감량을 계산하고, 시나리오 별 석탄가스화복합발전(Integrated Gasification Combined Cycle; IGCC)과 $CO_2$ 저감장치 설치 발전소의 진입경쟁에 대하여 분석하였다. 시뮬레이션 결과 탄소세가 증가하더라도 원자력발전소의 건설이 무조건 증가하는 것이 아니라 일정한 비율만을 차지하고, 석탄화력발전소의 감소비중을 LNG 복합화력이 차지하는 것을 알 수 있었으며, IGCC와 같은 대안 기술이 존재한다면 석탄화력의 감소비중의 일부를 차지한다.

화력발전소 보일러 연료소비량 계산 및 정확성 검증 (Fuel Consumption Rate Calculation Equation and its Application at fewer Boiler)

  • 장석원;김재훈
    • 에너지공학
    • /
    • 제14권2호
    • /
    • pp.147-152
    • /
    • 2005
  • 본 논문에서는 화력발전소 보일러 연료소비량을 측정에 의하지 않고 계산으로 구하는 방법을 세부 항목 별로 유도하고 그 결과를 검증하였다. 보일러 경계를 출입하는 Energy in Energy out의 정량적 관계를 분석하여 Energy in에 해당하는 투입열량과 Energy out에 해당하는 흡수열량 및 손실열량으로부터 에너지 출입의 유기적인 관계식을 수립하여 연료소비량 계산식을 유도, 정립하고 실제 운전중인 석탄 및 중 유연소 발전소에 적응하여 계산식의 정확성을 검증하였다.

500MW 화력발전소 저압터빈 Hood 공진 특성에 관한 연구 (Study on vibration characteristics of low pressure turbine hood resonance in a 500MW thermal power plant)

  • 조철환;조성태;구재량;김형석
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.23-27
    • /
    • 2013
  • In this research paper, we study on how to decrease the high vibration of turbine hood casings which are main facilities of power generation industry. Cause of Standard coal-fired power 500MW facilities turbine hoods' high vibration is that Natural frequency of hood casing designed in near domain frequency, when they are making hoods. We investigate to reduce high vibration at hood casing. We use FEM method to found how to avoid resonance, and test to confirm that our FEM result. We Finally attach minium mass plate at hood casing to avoid resonance and high vibration reduce lower $100{\mu}m$.