• Title/Summary/Keyword: Coal-Ash

Search Result 708, Processing Time 0.026 seconds

A Study on Collection Efficiency of Pilot Electrostatic Precipitator (연소장치를 이용한 소형 전기집진장치의 집진 효율에 관한 연구)

  • 한재균;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.125-131
    • /
    • 1993
  • Electrostatic Precipitator has been widely used to get high efficiency which is required for collection of fine particles. In order to provide collection efficiency and size distribution data for a pilot electrostatic precipitator, a pilot study has been conducted on fly ash from pulverized coal burning apparatus. The aims of this study are to investigate characteristics of electric charge, to measure collection efficiency varied with the applied voltage, to get an optimum current and current density. Optimum current density was obtained to 0.7mA/$cm^2$ at the average electric field strength 2.33kV/cm in this experiment. Maximum particle collection efficiency was indicated 99.21% at the applied voltage 7kV. Finally, particle size distribution is also compared with photographic results. Both coarse and fine particles at the range of 0.5$\sim$2$\mu$m and 3$\sim$10 SEM $\mu$m were clearly removed by increasing applied voltage.

  • PDF

Adsorption of Lead Ion by Zeolites Synthesized from Jeju Scoria (제주 스코리아로부터 합성된 제올라이트에 의한 납이온 흡착)

  • Kam, Sang-Kyu;Hyun, Sung-Su;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1437-1445
    • /
    • 2011
  • The adsorption performance of lead ion was studied using five zeolites (Na-P1, sodalite (SOD), analcime (ANA), nepheline hydrate (JBW), cancrinite (CAN)) synthesized from Jeju scoria. The adsorption performances of lead ion decreased in the order of Na-P1 > SOD > ANA > JBW > CAN. These results showed that the synthetic zeolite with a higher cationic exchange capacity showed a higher adsorption performance. The uptake of lead ion by synthetic zeolites were described by Freundlich model better than Langmuir model. The adsorption kinetics of lead ion by synthetic zeolites fitted the pseudo 2nd order kinetics better than pseudo 1st order kinetics. The effective diffusion coefficients of lead ion by synthetic zeolites were ten times higher than the zeolite A synthesized from coal fly ash.

CLASSIFICATION OF LAKE SEDIMENTS BY USING HYDROCYCLONES

  • Jo, Young-Min;Jang, Hyun-Tae
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2001.11a
    • /
    • pp.64-69
    • /
    • 2001
  • The present work provides a result from the preliminary experiment for hydrocyclone technology. In this work, local lake sediments and waste coal fly ash were used as test samples, prior to the application of hydrocyclone technology to the waste sludge thickening. A few cyclones based on the Rietema standard geometry were prepared. Chemical analysis of the sediments showed that more organic contaminants were in smaller particles. The experimental tests further showed that physical characteristics of particles, configuration of the cyclone and operation condition would affect the separation efficiency. The current results showed that small size cyclones might improve the separation and concentration of the lake sediments, and higher inlet velocity would increase the concentration rate of under flow and absolute concentration of sediment particles.

  • PDF

Prediction of Slagging Propensity of Coal Ash (석탄 회분의 융착성향 예측)

  • 이시훈;박주식
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 1995
  • 준역청탄에서 무연탄까지의 등급을 갖는 8개탄을 대상으로 ASTM 방법으로 회분을 제조하였으며 회분조성과 용융온도를 측정하여 각 시료의 융착성향을 비교하였다. 보다 간단한 방법으로 정확하게 융착성향을 예측하기 위한 방법을 찾는 것을 목적으로 시료의 색을 측정하였으며 TGA를 이용하여 회분중 휘발량을 측정하였다. 또한 1$600^{\circ}C$에서 회분을 용융시키고 다시 응고시켜 제조한 연마시료를 대상으로 표면에 형성된 공동크기를 분석하였으며 회분의 색, 휘발량, 공동크기 등과 융착성향과의 관계를 고찰하였다. 분석결과 회분의 색은 회분의 융착성향을 크게 구분할 수 있는 지표로써 사용될 수 있으며 TGA에 의한 회분중 휘발량의 측정은 용융온도와, 그리고 용융후 응고시편의 공동크기는 1$600^{\circ}C$에서 계산된 점도와 밀접한 상관성을 갖고 있어 이들을 석탄회분의 융착성향 예측에 사용할 수 있음을 알 수 있다.

  • PDF

Hydration Heat Analysis of Mass Concrete according to FAC and CGS Replacement Rates (FAC 및 CGS 치환율에 따른 매스 콘크리트의 수화열 해석)

  • Kim, Su-Hoo;Beak, Sung-Jin;Han, Soo-Hwan;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.158-159
    • /
    • 2022
  • This study analyzed the temperature stress through mixtures mass concrete hydration heat analysis according to the replacement rates of FAC and CGS. As a result of the analysis, it was possible to confirm the effect of reducing hydration heat when CGS is substituted for the low heat mixture of mass concrete. However, the stress of the FAC+CGS combination exceeded the tensile stress. It is believed that it is necessary to apply the insulating sheet of the surface part and reduce the unit weight of cement.

  • PDF

Characteristics of Adiabatic Temperature Rise for Concrete according to FA Cement and CGS Replacement Rate (FA시멘트 및 CGS 치환율에 따른 콘크리트의 단열온도상승 특성)

  • Baek, Sung-Jin;Hu, Yun-Yao;Kim, Su- Hoo;Han, Jun-Hui;Yoon, Chee Whan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.117-118
    • /
    • 2022
  • In this study, adiabatic temperature rise of concrete depending on binder compositions and CGS contents is studied to provide informations for CGS low-heating aggregate and mixture designs for upper and lower placement lifts. Test nresults indicate that it is desirable to apply the combination of binders between top and bottom lift. For top lift, SESC or ESC is recommended, and for bottom lift, FAC+CGS 50 % is good for material composition.

  • PDF

A study on the engineering optimization for the commercial scale coal gasification plant (상용급 석탄가스화플랜트 최적설계에 관한 연구)

  • Kim, Byeong-Hyeon;Min, Jong-Sun;Kim, Jae-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.131.1-131.1
    • /
    • 2010
  • This study was conducted for engineering optimization for the gasification process which is the key factor for success of Taean IGCC gasification plant which has been driven forward under the government support in order to expand to supply new and renewable energy and diminish the burden of the responsibility for the reduction of the green house gas emission. The gasification process consists of coal milling and drying, pressurization and feeding, gasification, quenching and HP syngas cooling, slag removal system, dry flyash removal system, wet scrubbing system, and primary water treatment system. The configuration optimization is essential for the high efficiency and the cost saving. For this purpose, it was designed to have syngas cooler to recover the sensible heat as much as possible from the hot syngas produced from the gasifier which is the dry-feeding and entrained bed slagging type and also applied with the oxygen combustion and the first stage cylindrical upward gas flow. The pressure condition inside of the gasifier is around 40~45Mpg and the temperature condition is up to $1500{\sim}1700^{\circ}C$. It was designed for about 70% out of fly ash to be drained out throughout the quenching water in the bottom part of the gasifier as a type of molten slag flowing down on the membrane wall and finally become a byproduct over the slag removal system. The flyash removal system to capture solid particulates is applied with HPHT ceramic candle filter to stand up against the high pressure and temperature. When it comes to the residual tiny particles after the flyash removal system, wet scurbbing system is applied to finally clean up the solids. The washed-up syngas through the wet scrubber will keep around $130{\sim}135^{\circ}C$, 40~42Mpg and 250 ppmv of hydrochloric acid(HCl) and hydrofluoric acid(HF) at maximum and it is turned over to the gas treatment system for removing toxic gases out of the syngas to comply with the conditions requested from the gas turbine. The result of this study will be utilized to the detailed engineering, procurement and manufacturing of equipments, and construction for the Taean IGCC plant and furthermore it is the baseline technology applicable for the poly-generation such as coal gasification(SNG) and liquefaction(CTL) to reinforce national energy security and create new business models.

  • PDF

A Study on Manufacturing Cokes for Ferroalloy Using Domestic Anthracite and Waste Plastic (국산(國産) 무연탄(無煙炭)과 폐플라스틱을 사용(使用)하는 합금철용(合金鐵用) 코크스의 제조(製造)에 관한 연구(硏究))

  • Lee, Gye-Seung;Song, Young-Jun;Seo, Bong-Won;Lee, Dae-Young;Lee, Sung-Riong;Yoon, Si-Nae;Kim, Youn-Che
    • Resources Recycling
    • /
    • v.17 no.4
    • /
    • pp.47-56
    • /
    • 2008
  • The aim of this study is to produce cokes which can be used for the production of ferroalloy, for this purpose, domestic anthracite mixed with plastic was sintered at various condition. The combustion and physical properties of anthracite and plastic, coal separation, and the influence of factors on the strength of coke were investigated. The results of this study are as follows: 1. The three kinds of anthracite from the Samcheok region contained 25 to 30% ash of $100{\mu}m$ over size, and have the caloric value of 5,205 cal/g(TaeAn), 4,893 cal/g(JangSung), 4,873cal/g(KyongDong). 2. The recommendable conditions for heavy-fluid separation of the Samcheok coal are to set the specific gravity of heavy fluid to 2.4 and control the size of coal to $35{\sim}140mesh$. 3. It is concluded that phenolic resin powder, liquefied phenolic resin, SAN, and melamine resin can be used as a binder for the anthracite cokes, from the thermal analysis of various plastics. Especially, the liquefied phenolic resin was considered as the most suitable binder as it would simplify the process.

Studies of the Fusibility of Coal Ashes in Oxidizing and Reducing Conditions (산화성 및 환원성분위기에서 석탄회분의 용융성)

  • Park, Chu-Sik;Lee, Shi-Hun;Choi, Sang-Il;Yang, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.179-190
    • /
    • 1997
  • To study the effects of chemical composition on the fusion temperatures of coal ashes, the chemical composition, mineral matter, and fusion temperature were studied with 54 kinds of coal ash samples including Korean anthracite coals. CaO, MgO and $Fe_2O_3$ were observed to be major fluxing elements in reducing and oxidizing atmosphere. The fluxing effect of $Fe_2O_3$ was increased more in reducing atmosphere. In a base/acid ratio, the fusion temperature decreased with increasing amounts of basic components. Nevertheless, the correlation between a fusion temperature and base/acid ratio was not shown well in a higher ratio of $Fe_2O_3/CaO$. The differences of fusion temperatures between oxidizing and reducing atmosphere showed close relationship with $SiO_2/Al_2O_3$ ratio rather than with $Fe_2O_3$ contents. Multiple regression was used to predict the fusion temperature of coal ashes, and it was established that the major predictors in oxidizing atmosphere were Base/Acid, $Fe_2O_3/CaO$, $SiO_2/Al_2O_3$, and $(SiO_2/A1_2O_3){\cdot}(Base/Acid)$ and Base/Acid, $Fe_2O_3/CaO$, $SiO_2$, and $TiO_2$ were major ones in reducing atmosphere.

  • PDF

Characteristics of sound absorption materials by using ecological aggregates (에코골재를 사용한 흡음재의 특성)

  • Kim, Kang-Duk;Ryu, Yu-Gwang;Kim, Yoo-Taek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.6
    • /
    • pp.264-270
    • /
    • 2008
  • Ecological lightweight aggregates were made by using the wastes come from various industrial fields. Wastes were crushed and pulverized by mills and a certain portions of wastes were mixed and formed by pelletizer like small beads. The formed lightweight aggregates were finally sintered with $1125^{\circ}C$/15 min conditions by using rotary kiln. Lightweight concrete sound absorbers were made of ecological lightweight aggregates K73 (Coal bottom ash 70 wt%: Dredged soil 30 wt%) and K631 (Clay 60 wt%: Stone sludge 30 wt%: Spent bleaching clay 10 wt%). For the reference, lightweight concrete sound absorbers made of DL (German made 'L' company LWA) were also made under the same conditions. Sound absorption characteristics were observed and measured according to the kinds of aggregates, water/cement ratio (W/C=20, 25, and 30%), and designed pore rates (V=20, 25, and 30%). The pore rates of the lightweight concrete sound absorber were turned out to be 5 to 10% higher than designed ones. Absorption coefficient of the lightweight concrete sound absorber by using K631 aggregates with W/C=20% and V=25% conditions was 0.88 at 1000 and 3150 Hz from the measurement by the impedance tube.