• Title/Summary/Keyword: Coagulation-Sedimentation

Search Result 117, Processing Time 0.032 seconds

A Study on the Reduction of Color in Dye Wastewaters by Physico-chemical Processes (물리, 화학적 처리방법에 의한 염색폐수의 색도제거에 관한 연구)

  • 이준석;김민호;김영규
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.29-35
    • /
    • 1993
  • This study was performed to obtain optimal conditions for reduction of color in dye wastewaters using coagulation-sedimentation processes with redox reactions. The reduction of color as well as organic matters variation was observed after coagulation-sedimentation processes using FeSO$_4$ $\cdot$ 7H$_2$O and NaOCl. Coagulation-redox reaction was done with the dose of Coagulant and oxidant at various pH values. Redox reaction was done through jar-mixing and aeration. The results of study were as follows: 1. In the coagulation-sedimentation processes using FeSO$_4$ $\cdot$ 7H$_2$O, color reduction was heigher at pH 3. With variance of dosage of FeSO$_4$ $\cdot$ 7H$_2$O, color reduction was higher at 250 mg/l. When coagulation-sedimentation using FeSO$_4$ $\cdot$ 7H$_2$O 250 mg/l was added at pH 3, the reduction of color, COD$_{Mn}$, and COD$_{Cr}$ showed 47.6%, 21.3% and 22.1%, respectively. 2. When NaOCI was added at level of 100 ppm in raw wastewater at pH 3, the reduction of color, COD$_{Mn}$, and COD$_{Cr}$ showed 30.2%, 5.5% and 6.2%, respectively. 3. After coagulation-sedimentation processes by addition of FeSO$_4$ $\cdot$ 7H$_2$O, when NaOCl was added at level of 250 mg/l in supernant, color reduction was 47.8% in aeration and 37.5% in jar-mixing. 4. Color reduction by aeration was higher than that by jar-mixing.

  • PDF

A Study on Effect of Jet Mixed Separator Combination for Pre-treatment of Ultrafiltration Membrane Filtration Process (UF 막 여과 공정의 효과적인 전처리 공정으로 분류교반고액분리조(噴流攪拌固液分離槽) (Jet Mixed Separator: JMS) 도입 효과에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Watanabe, Yoshimasa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.38-46
    • /
    • 2005
  • In this research, we tried to combine the coagulation/sedimentation process as pre-treatment with UF membrane filtration to reduce the membrane fouling and to improve the permeate water quality. We used the Jet Mixed Separator (JMS) as coagulation/sedimentation process. We observed that the HPC and E.Coli can't be removed through the direct UF memebrane filtation of surface water. The removal efficiency of dissolved organic substances, indicated by E260 and DOC, was 40% and 15%, respectively. However, the removal efficiency of it increased two time as a result of combination of JMS process as coagulation/sedimentation pre-treatment. This was resulted from the formation of high molecular humic micro-floc through JMS process. The accumulation amount of irreversible cake layer which was not removed by backwashing was less than direct UF membrane filtration of surface water. Moreover, the loading rate of fouling induced substances, such as humic substances and suspended substances, on membrane surface decreased drastically through JMS process. As a result, the accumulation amount of irreversible cake on membrane surface was decreased.

Rheological Study on bentonite Clay Sedimentation with various concentrations of Sea water (해수의 농도 변화에 따른 bentonite 침전에 대한 유변학적 고찰)

  • 최상원;서호준
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.35-41
    • /
    • 1996
  • For studying of coagulation and sedimentation in estuarine clay, we obtained several flow curves with various concentrations of sea water by using Coutte type rotational rheometer. The initial shear stress on high concentration of sea water was observed big, but after this, its value is decreasing with increasing shear rate. The maximum pick of shear stress is decreasing with the decreasing of concentration of sea water The trend is same totally above for viscosity. The sedimentation times with the concentration of sea water vary in $\infty$ ~ 5 minutes. The zeta potential is changed dramatically between 114 and 118 concentration of sea water. That is consistent with the sedimentation graph. From these results, the phenomena of coagulation and sedimentation can be explained with viscoelastic terms on structual formation among particles by the changes of surface potential affected from contacting sea water to dispersed particles.

  • PDF

Pilot Scale Assessment of DOC and THMs Removal in Conventional Water Treatment System

  • Lee, Choong-Dae;Lee, Yoon-Jin
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.829-834
    • /
    • 2006
  • This research aims to investigate the behavior of organic matter that causes bacterial re-growth and the formation of disinfectant by-products such as THM in water treatment, and to optimize conditions for a more efficient and conventional water facility. THM removed 51 % and 12 % through coagulation/sedimentation and filtration using a selected conventional system. In this experiment, the removal ratio of DOC was highest at 68 % when the Gt value was 42,000 and lowest at 41 % when the Gt value was 30,000. 77-84 % of total DOC was removed during coagulation/sedimentation, and 15-23 % was removed during filtration. When Gt values were between 30,000 and 66,000, over 50 % of high molecular matter above 10 K during coagulation/sedimentation was removed. Turbidity removed 98 % when the G1 value was 66,000. As the Gt value increased, the turbidity removal ratio increased. Turbidity removed over 20 % during the filtration process.

ε-polylysine biopolymer for coagulation of clay suspensions

  • Kwon, Yeong-Man;Im, Jooyoung;Chang, Ilhan;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.12 no.5
    • /
    • pp.753-770
    • /
    • 2017
  • The coagulation or flocculation of cohesive clay suspensions is one of the most widely used treatment technologies for contaminated water. Flocculated clay can transport pollutants and nutrients in ground water. Coagulants are used to accelerate these mechanisms. However, existing coagulants (e.g., polyacrylamide, polyaluminum chloride) are known to have harmful effects in the environment and on human health. As an alternative, eco-friendly coagulant, this study suggests ${\varepsilon}-polylysine$, a cationic biopolymer fermented by Streptomyces. A series of sedimentation experiments for various ${\varepsilon}-polylysine$ concentrations were performed, and the efficiency of sedimentation with ${\varepsilon}-polylysine$ was estimated by microscopic observation and light absorbance measurements. Two types of sedimentation were observed in the experiments: accumulation sedimentation (at 0.15%, 0.20%, 0.25% ${\varepsilon}-polylysine$) and flocculation sedimentation (at 0%, 0.1%, 0.5%, 1.0%, 2.0% ${\varepsilon}-polylysine$). These sedimentation types occur as a result of the concentration of counter ions. Additionally, the performance of ${\varepsilon}-polylysine$ was compared with that of a previously used environmentally friendly coagulant, chitosan. The obtained results indicate that flocculation sedimentation is appropriate for contamination removal and that ${\varepsilon}-polylysine$ functions more efficiently for clay removal than chitosan. From the experiments and analysis, this paper finds that polylysine is an alternative eco-friendly coagulant for removing chemical contaminants in groundwater.

Fate and Characteristics of Dissolved Organic Matters in a Water Reclamation Facility, Korea (하수처리수 재이용시설의 공정별 용존유기물질 거동 및 특성)

  • Kwon, Eun-Kwang;Lee, Wontae
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.355-362
    • /
    • 2021
  • This study investigated the fate of dissolved organic matter (DOM) in a water reclamation facility (WRF) in Korea. The WRF consists of coagulation, sedimentation, microfiltration, and reverse osmosis (RO) components. The production capacity of WRF is 90,000 m3/day. The reclaimed water is reused as industrial water. We also characterized DOM in raw, processed, and finished waters based on analysis of dissolved organic carbon (DOC), ultraviolet absorbance at 254 nm (UVA254), fluorescence excitation emission matrix (FEEM), and DOC fractions via liquid chromatography-organic carbon detection (LC-OCD). Based on the results of DOC, UVA254, and FEEM analyses, neither the coagulation/sedimentation nor the microfiltration at the WRF effectively removed DOM. The RO process removed more than 94% of DOM. The raw water (i.e., secondary treated effluent obtained from a wastewater treatment plant) exhibited tryptophan-like peaks, which are a promising marker of wastewater, in the FEEM analysis. Coagulation and microfiltration failed to eliminate the wastewater marker, whereas RO completely removed it. The raw water also carried high levels (89.4%) of hydrophilic and low-molecular weight substances, which are difficult to remove via coagulation-sedimentation or microfiltration. Humic substance was a major component of the hydrophilic fractions. Based on the LC-OCD analysis, RO effectively removed the humic and polymeric materials from DOM.

A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System (응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Kim, Seung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

Effect of Coagulation and Homogenization on the Dissolved Air Flotation and Sedimentation of Bulking Sludge (응집과 균질화가 팽화슬러지의 용존공기부상과 침전에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.68-74
    • /
    • 2007
  • The objective of this study is to examine the effect of the coagulation and homogenization in bulking sludge thickening of paper manufacturing plant using DAF(Dissolved Air Flotation) and gravitational sedimentation. The effects of parameters such as dosage of coagulant and homogenization time were examined. The results showed that DAF and sedimentation was affected aluminum sulfate and anion polymer coagulant differently. At the optimum dosage of aluminum sulfate, thickening efficiency of DAF and sedimentation process were increase 1.25 time and 2.02 time, respectively. At the optimum dosage of anion polymer coagulant, thickening efficiency of DAF process was increase 1.35 time, but thickening efficiency at sedimentation was 1.06 time. When anion polymer coagulant of 0.5 mg/l was added in DAF process, water content of sludge was decreased from 96.6% to 90.7% in dewatering process using Buchner funnel test device. After homogenization(20500 rpm, 10 min), Sauter mean diameter of sludge floc was decreased from 631 ${\mu}m$ to 427 ${\mu}m$, however increase of flotation efficiency by DAF was only 1.09 time.

Comparison of the PO43- Ion Removal Efficiency Using Various PAC Coagulant Types in Sedimentation and Flotation Processes (침전 및 부상 공정에서 PAC 응집제 종류별 PO43- 이온 제거 효율 비교)

  • Jeong-Hak Choi;Ju-Seop Kim;Jong-Won Park;Seong-Kee Min;Hye-Yeon Lee;Chang-Han Lee
    • Journal of Environmental Science International
    • /
    • v.33 no.9
    • /
    • pp.667-674
    • /
    • 2024
  • In the present study, we aimed to determine the optimal polyaluminum chloride (PAC) dosage in raw water based on the PO43--P concentration using PAC coagulants with aluminum concentrations of 10%, 12%, and 17%. The correlation between the Al/P molar ratio and the removal efficiency of aggregated Al-PO43--P flocs was evaluated using sedimentation and flotation processes. As the PO43--P concentration in the raw water increased, the Al/P molar ratio gradually decreased from 6.14 to 1.98. The Al/P molar ratio of PAC formulations with higher aluminum contents showed a decreasing trend in the following order: PAC 17% < PAC 12% < PAC 10%. An increase in the Al/P molar ratio led to a slight increase in the average particle size of Al-PO43--P flocs formed during the coagulation process. At optimal Al/P molar ratios, PO43--P removal efficiency ranged from approximately 80% to 93% for both the coagulation/precipitation and coagulation/flotation processes. The coagulation/flotation process exhibited a slightly higher PO43--P removal efficiency than coagulation/precipitation.

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.