• Title/Summary/Keyword: Coagulants

Search Result 249, Processing Time 0.031 seconds

Systemic Lupus Erythematosus in a Dog, Suspexted Systemic Lupus Erythematosus in a Dog, and Autoimmune Thrombocytopenic Purpura Hemorrhagica in a Dog (개에 있어서 전신성홍반성루프스 1예와 전신성혼반성루프스 의증 1예 및 자가면역성혈소판감소성출혈성자반병 1예)

  • 이창우;나기정;임정식;서정욱
    • Journal of Veterinary Clinics
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 1996
  • Systemic lupus erythematosus in a dog, suspected systemic lupus erythematosus in a dog, and autoimmune thrombocytopenic purpura hemmorrhagica in a dog are reported. A fice-year old, female Chihuahua (Case 1) showed initially hemorrhagic diathesis and purpura hemorrhagica. Afterward, it showed polymyositis and polyarthritis. LE-cell was demonstrated on LE-cell preparation trom blood. Systemic lupus erythematosus was diagnosed. This reponded well to the immunosuppressants, but developed iatrogenic Cushing syndrome and steroid hepatopathy. A two-and-half-year old, male toy poodle (Case 2) had chief complaint of red urine. Occult blood test for the urine sediment. This did not respond at all to antibiotics and carbazochrome, which is one of systemic coagulants. LE-cell was demonstrated on LE-cell preparation from blood. This responded relatively well to immunosupressants such as prenisolone, azathioprine and cyclophosphamide. systemic lupus erythematosus is suspected. A nine-year-and-three-month old, female Maltese (Case 3), which had history of congestive heart failure and ovariohysterectomy showed purpura hemorrhagica in the skin of chest. This had severe thrombocytopenia and leukocytosis. As prednisolone was administered before immunological examination or demonstration of LE-cell, it was impossible to diagnose whether purpura hemorrhagica developed as a member of systemic lupus erythematosus or independent of systemic lupus erythematosus. This responded well to prednisolone, and so autoimmune thrombocytopenic purpura hemorrhagica was diagnosed.

  • PDF

The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank (응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리)

  • Kim, Dong-Ha;Lee, Soo-Young;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Assessment and its control of non-point source pollution in Korea: Review (국내 비점오염 현황 및 제어방안: 총설)

  • Kang, Minwoo;Lee, Sangsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.457-467
    • /
    • 2019
  • Because non-point source pollution is very closely related to hydrological characteristics, its importance is highly emphasized nowadays along with accelerating climate change. Especially for Korea, the non-point source pollution and its control are entirely depending on runoff, precipitation, drainage, land use or development, based on geographical and topographical reasons of Korea. Many studies reported the physical (e.g., apparatus- and natural-type facilities, etc.) and chemical methods (e.g., organic and inorganic coagulants, etc.) of controling non-point pollutant source pollution, however, those are needed to be reconsidered along with climate change causing the unexpected patterns and amounts of precipitation and strengthen complexity of social community. The objectives of this study are to assess recent situations of non-point source pollution in Korea and its control means and to introduce possible effective ways of non-point source pollution against climate change in near future.

Effect of residual metal salt on reverse osmosis membrane by coagulation-UF pretreatment process (응집-UF 전처리 공정에 의한 잔류 금속염이 역삼투막에 미치는 영향)

  • Go, Gilhyun;Kim, Suhyun;Kang, Limseok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.413-420
    • /
    • 2019
  • Pretreatment system of desalination process using seawater reverse osmosis(SWRO) membrane is the most critical step in order to prevent membrane fouling. One of the methods is coagulation-UF membrane process. Coagulation-UF membrane systems have been shown to be very efficient in removing turbidity and non-soluble and colloidal organics contained in the source water for SWRO pretreatment. Ferric salt coagulants are commonly applied in coagulation-UF process for pretreatment of SWRO process. But aluminum salts have not been applied in coagulation-UF pretreatment of SWRO process due to the SWRO membrane fouling by residual aluminum. This study was carried out to see the effect of residual matal salt on SWRO membrane followed by coagulation-UF pretreatment process. Experimental results showed that increased residual aluminum salts by coagulation-UF pretreatment process by using alum lead to the decreased SWRO membrane salt rejection and flux. As the salt rejection and flux of SWRO membrane decreased, the concentration of silica and residual aluminum decreased. However, when adjusting coagulation pH for coagulation-UF pretreatment process, the residual aluminum salt concentration was decreased and SWRO membrane flux was increased.

Extension of Tofu Shelf-Life with Water Soluble Degraded Chitosan as a Coagulant (수용성 키토산 분해물질을 응고제로 이용한 두부의 저장성 증대)

  • 전기환;전기환;함영태
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.1
    • /
    • pp.161-166
    • /
    • 1999
  • CaCl2 and water soluble degraded chitosan mixtures were used as coagulants for extending the shelf life of tofu. Microbial counts, pH, and turbidity in tofu immersion solution were analyzed during the periods of storage at 4oC and physico chemical properties of tofu were determined by rheological properties, color and yield. There was no significant difference in moisture content and yield between tofu made with and without chitosan. Failure stress and stress relaxation values were reduced when chitosan was added to CaCl2, but there was no significant change among contents of chitosan added to tofu. The pH values were decreased at the beginning and then slowly increased after 14 days storage. The changes in turbidity were increased during storage, but the change in 2.0g degraded chitosan mixture with 7.0g CaCl2 coagulant(2.0:7.0 ratio) was lower than others and initial turbidity was lower as much as chitosan added to coagulant. These data showed that the water soluble degraded chitosan had a good anti microbial effect and increases the shelf life of tofu.

  • PDF

Removal characteristics of organic matter during pretreatment for membrane-based food processing wastewater reclamation

  • Jang, Haenam;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.205-210
    • /
    • 2018
  • In this study, we investigated coagulants such as polyaluminum chloride (PACl) and ferric chloride ($FeCl_3$) and the combination of a coagulant and powdered activated carbon (PAC) for the removal of dissolved organic matter (DOM) from fish processing effluent to reduce membrane fouling in microfiltration. The efficiency of each pretreatment was investigated through analyses of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$). Membrane flux and silt density index (SDI) analyses were performed to evaluate membrane fouling; molecular weight distributions (MWD) and fluorescence excitation-emission matrix (FEEM) spectroscopy were analyzed to assess DOM characteristics. The results demonstrated that $FeCl_3$ exhibited higher DOC and $UVA_{254}$ removals than PACl for food processing effluent and a combination of $FeCl_3$ and PAC provided comparatively better results than simple $FeCl_3$ coagulation for the removal of DOM from fish processing effluent. This study suggests that membrane fouling could be minimized by proper pretreatment of food processing effluent using a combination of coagulation ($FeCl_3$) and adsorption (PAC). Analyses of MWD and FEEM revealed that the combination of $FeCl_3$ and PAC was more efficient at removing hydrophobic and small-sized DOM.

Study on the Treatment of Contaminated Lake Water Using Micro Air Bubbles (미세기포를 이용한 오염 호소수의 정화에 관한 연구)

  • Kim, Jun-Young;Park, Chang-Won;Lee, Jong-Kyung;Chang, In-Soung
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • Many lakes or irrigative reservoirs in Korea are rapidly contaminated due to the ever increasing pollutants. Although lots of treatment processes have been recommended and practiced, economical and technical improvement is currently needed. In this study, contaminated irrigation reservoir was treated using the proposed process which is consisted of fine air bubbles, coagulation and flotation. Fine bubbles, approximate diameter of 3 to $10{\mu}m$, were generated using cavitation in the pressurized tank and polyaluminum chloride was used as coagulants. This fine bubbles, coagulation and flotation effectively controlled the low density algae, for example, Chlorophyll-a was removed more than 97 %. Removal efficiency of COD, SS, T-N and T-P were 80.7%, 94.3%, 64.1 % and 92.4%, respectively. Pollutants released from the sediments was removed more than 80% of organics and 60-70 % of nutrients. Consequently, fine bubbles coagulation and flotation process could be effectively used as an alternative treatment method for the purpose of control of lake water quality.

ENHANCED COAGULATION: DETERMINATION OF CONTROLLING CRITERIA AND AN EFFECT ON TURBIDITY REMOVAL

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.105-111
    • /
    • 2005
  • The applicability of the USEPA's (United States Environmental Protection Agency) three criteria of enhanced coagulation (criterion 1-TOC level less than 2 mg/l. before chlorination; criterion II-% requirement of TOC removal; criterion III-point of diminishing return) for Korean waters was evaluated in this study. This study also investigated an effect of enhanced coagulation on turbidity removal, and attempted to identify the best coagulant for enhanced coagulation. Three different waters were used in this study: one river water and two lake waters. five different coagulants were used: alum, liquid alum, PACl, ferric chloride with and without water. Results of this study showed that all three criteria were achievable for the tested waters. For these waters, controlling criterion was found to be different depending upon raw water characteristics. When initial Toe level was low(< 4 mg/L), criterion I (< 2 mg/L) could be the controlling criterion. As TOC level increased, criterion II (% TOC removal) became the controlling criteria. It was possible to achieve different goals of turbidity and TOC removals. Although the optimum region of TOC removal was more acidic than that of turbidity removal, there was no conflict between these two removals. The best coagulant was found to be different depending upon the evaluation tool: maximum and optimum removal. ferric chloride was more effective than alum in terms of the maximum TOC removal, while Al-based coagulant such as alum or PACl was the best coagulant in terms of the optimum TOC removal.

Effect of Microbial Activity by Using the Coagulants in the Biological Treatment Process (생물학적 처리공정에서 응집제 사용에 따른 미생물 활성도 영향)

  • Han, Seung-Woo;Chun, Mi-Hee;Park, Jun-Min;Kang, Dong-Hyo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • Alum contained dominantly the monomeric aluminum species, and PAC contained the polymeric aluminum species. Both Alum and PAC has been improved removal of TP with increasing coagulant dose. Coagulant used directly influenced the microbial activity. Impact on microbial activity, the PAC was smaller than Alum. And impact on microbial activity and population according to the return sludge appeared to be minor.

Effects of polymeric Al and hydrolysis products of PAC at different pH on performance of nanofiltration with PAC coagulation pretreatment (PAC 전처리 시 수소이온 농도에 따라 발생 가능한 알루미늄 종에 의한 나노여과막 성능 연구)

  • Choi, Yang-Hun;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.15-24
    • /
    • 2010
  • Coagulation can be used for pretreatment of NF membrane filtration. Foulants such as organic matter and particulate can be removed effectively with the process while high flux recovery is maintained. Recently various types of polyaluminium coagulants including polyaluminium chloride(PAC) are commercially available for water treatment. This study examines effects of polymeric Al and hydrolysis products of PAC on nanofiltration membrane performance. Dominant hydrolysis products were polymeric Al, $Al(OH)_3$, and ${Al(OH)_4}^{-1}$ at acidic, neutral, and alkaline pH conditions, respectively. Under acidic pH condition, flux decline was increased with increasing PAC concentrations, possibly due to polymeric Al adsorption on membrane pore and/or surfaces. For neutral and alkaline pH conditions, little flux decline was observed with increasing PAC concentrations except the highest ${Al(OH)_4}^{-1}$ concentration, with which rapid flux decline was shown. Removal of ionic matters was also varied with pH conditions in this study. Especially, conductivity removal was substantially low and $Ca^{2+}$ concentration in the permeate was quite high at neutral pH condition.