• Title/Summary/Keyword: Coagulants

Search Result 253, Processing Time 0.025 seconds

A Fundermental Study Color Removal of Dyeing Wastewater using Low Cost Adsorbents (저가흡착제를 이용한 염색폐수의 색도제거에 관한 기초 연구)

  • 김은호;장성호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.40-45
    • /
    • 1999
  • This study deals with an investigation on low cost adsorbents locally available n dyeing wastewater treatment of color removal. Peat, bentonite, slag and fly ash were utilized for this study. Considering that low cost adsorbents contained in $SiO_2$, $Fe_2O_3$ and $Al_2O_3$ compositions, and coagulants were mainly used aluminate and ferrate in color removal. Color of dyeing wastewater was high removed in peat, berntonite and slag except for fly ash with passed time. It could be known that color removal of peat and slag were increased to pH 4, but was hardly changed with advancing to alkaline. Color intended to be high removed with increasing of agitation speed but to be almost slow after 150rpm. As a result on the experiment of Freundlich adsorption isotherms, adsorption intensity(l/n) appeared to be peat>fly ash>slag>bentonite and adsorption capacity(k) came out peat>bentonite>slag>fly ash. Therefore, if low cost adsorbents substituted for existing adsorbents, peat, bentonite and slag could look forward to an expected economical effect.

  • PDF

Effect of Polymer Coating on the Initial Microorganism Attachment and the Biofilm Growth (고분자 물질 도포가 미생물 부착과 생물막 성장에 미치는 영향)

  • 박영식;송승구
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.104-109
    • /
    • 1998
  • The objective of this study was to examine the effect of polymer coating on the initial microorganism attachment and the biofilm growth. Such as nonion(polyacrylamine), anion(CMC-Na) and cation polymer coagulant(chitosan and PEI) were used for coating material of the support carrier(acryl plate). When polymer coagulant was coated with 5, 10, 20, 35, 50, 100 and 200 mg/l on the surface of acryl plate, initial microorganism attachment increased and optimum concentration for the attachment was 35 mg/l. Biofilm growth experiments were conducted with the substrate loading of 12.7gSCOD/$m^2\cdot$ day using RBC. The polymer coagulants such as CMC-Na, polyacrylamide, PEI and chitosan coating on the acryl plate facilitated the biofilm growth of microorganisms. Until the biofilm dry weight grows up to 0. 0038g/cm$^2$, biofilm growth on the plate coated with cation polymer like chitosan was better than that on the coated plate of nonion(polyacrylamine), anion(CMC-Na) polymer coagulant.

  • PDF

Studies on the Biological Treatment of Dye Waste Water and Degration of Polyvinyl Alcohol (염색공장 폐수중 PVA 분해세균의 분리 및 생물학적 처리효과)

  • 강선태;서승교;권오억
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 1990
  • As a research for treatment of waste water by biological method, we investigated general characteristics of waste water and isolated some useful bacteria which effectively treated waste water. Compositions of waste water were analyzed to give COD 2060 ppm, PVA 560 ppm, T-N 50 ppm, T-P 3.3 ppm and PH 12. Also, we inverstigated optimum nutrients requirement and growth conditions by mixed culture as well as the effect of coagulants. The COD removal rate reached maximum state for 48 hrs culture at pH 7.0 and 30$^{\circ}$C. Alum as the coagulated was the most effective. The COD removal rate was also increased by supplementing 10 ppm phosphorous sources as additional nutrients. The COD of waste water was reduced to 10% of its initial value by the continuous culture. As a result of overall experiments the COD of effluents became about 100 ppm and final pH 7.

  • PDF

Treatment of Dyeing Wastewater by Flocculation with Calsium and Magnesium salts (칼슘과 마그네슘염을 이용한 염색폐수의 응집처리)

  • 김재용;서완주
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.89-98
    • /
    • 2002
  • The changes of conventional clarification process and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. The removal of waste matters such as SS, organic matter, color and turbidity contained in dyeing wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 84% of color in dyeing watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.

Use of Ferrous and Ferric Coagulants To Reduce Bromate and Particulate Levels (입자상 물질 및 Bromate의 저감을 위한 철염응집제의 이용)

  • Krasner Stuart-W;Yates Richard-S;Amy Gary;Garside Jason
    • 수도
    • /
    • v.24 no.4 s.85
    • /
    • pp.39-46
    • /
    • 1997
  • 실험실 규모의 연구를 확대한 Pilot-Plant연구는 Bromate 감소에 대한 다양한 수질 문제에 대응할 수 있었다. 이러한 연구를 통해 산성하에서 $Fe^{2+}$을 주입시 Bromate가 감소됨을 확인하였다. 그러나 이러한 반응은 느린 반응이었으며, 온도에 의존하는 반응이었다. 단독응집제로서 $Fe^{2+}$은 탁도를 증가시켰다. 따라서 탁도를 제어하기 위해 $Fe^{2+}$를 주입하였다. $Fe^{2+}$/$Fe^{3+}$응집제의 조합으로 TOC를 제거할 수 있었다. 초기 결과를 통해 이러한 공정은 매우 면밀히 추진되어야 하며, 모든 온도에서 적용될 수 없었다. 현재까지 얻어진 결과에 의하면 오존처리함으로서 발생되는 Bromate를 최소화하는 방안은 낮은 pH조건과 $Fe^{2+}$의 주입이다. 최종 처리수에서 입자상물질과 철을 최소화하기 위해서는 pH 등과 같은 조건들을 변화시켜 여과공정 이전에 잔류 $Fe^{2+}$를 산화시킬 수 있도록 초기에 최적화가 이루어 져야 한다.

  • PDF

Treatment of stock wastewater by flocculation with Calsium and Magnesium salts (칼슘과 마그네슘염을 이용한 축산폐수의 응집처리)

  • 김재용
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.10-18
    • /
    • 2002
  • The changes of conventional clarification processe and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. In this context as new flocculation using calcium hydroxide and magnesum sulfate was carried out. The removal of waste matters such as SS, organic matter, COD, nitrogen and phosphorus contained in stock wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 60% of COD in stock watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.

A Study on Color Treatment of Dyeing Wastewater with Bittern+Iron(II) chloride (간수+염화일철을 이용한 염색폐수 색도처리에 관한 연구)

  • 김만구;서명포
    • Textile Coloration and Finishing
    • /
    • v.12 no.3
    • /
    • pp.218-223
    • /
    • 2000
  • Color removal of dyeing wastewater is becoming more important due to intensive limitation on color unit of effluent water, so this study was to investigate an efficient color removal of dyeing wastewater. We found that bittern+iron chloride(II) inorganic coagulant developed by Kabool research center is much higher than any other inorganic coagulants for color removal. Optimum pH of this coagulant was 10.5 and removed more than 90% for color removal efficiency. The results showed that COD and color unit of effluent water was average 60mg/L and 200~250 units when continuous activated sludge test after coagulation with this coagulant has done. From the results of the experiments, the application of bittern+iron chloride(II) inorganic coagulant can save the operating cost of wastewater treatment plants.

  • PDF

Effects of Oil and Sugar on SPI-Tofu Characteristics Under Model System (모델시스템에서 기름과 당이 분리대두단백 두부의 특성에 미치는 영향)

  • 김동원;구경형;최희숙;김우정
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.1
    • /
    • pp.90-97
    • /
    • 1994
  • Effect of addition of oil , sucrose, dextrin and oil-sucrose (1 : 1 w/w) mixture on SPI tofu was investigated. The characteristics measured were yield , water holding capacity , textural and organoleptic properties. THe SPI tofufwas prepared by coagulation of soyprotein isolate (SP) suspensino by CaCl$_2$ , CaSo$_4$ an dGDL , followed by compression . Addition of oil to SPI increased the tofu yield and water holding capacity, particulary for those tofu coagulated by CaCl$_2$. Eventhough dextrin addition decreased the yield, it showed the most improving effect on water holding capacity. The tofu prepared by CaSO$_4$coagulant resulted highest in yield and water holding capacity. Hardness was found to be decreased as the oil, sucrose and dextrin added more and adhesiveness, cohesiveness and guminess were also affected. The sensory evaluation showed the SPI tofu prepared by CaSO$_4$ and 10% addition of oil and sucrose mixture to be realtively high in hardness , elasticity and uniformity of the texture.

  • PDF

Comparison of Removal Rates of Sedimentation and DAF(Dissolved Air Flotation) for various Different Conditions in Water Treatment (정수처리공정의 침전법을 개선하기 위한 대체공정으로 용존공기부상법(DAF)을 사용할 때 여러조건에 대한 처리효율 비교)

  • Kim, Mi-Jeong;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.118-125
    • /
    • 1997
  • Conventional sedimentation method has some limitations for turbidity removal in water treatment because drinking water sources are getting polluted. Removal rates of turbidity using DAF and sedimentation process were compared for various water conditions to know whether DAF is effective to improve sedimentation process. Water samples were clay(gravity 2.65) water 100mg/l, H raw water, mixed water of H raw water and clay 100mg/l, and mixed water of HA(Humic Acid) 5mg/l and clay 100mg/l. Other parameters were temperature, coagulants(Alum, $FeCl_3$), and treatment time. Water temperature greatly affected in removal rates of turbidity for sedimentation and DAF. Generally DAF was more effective in removal rates of turbidity than sedimentation at the same experimental condition. Removal rates of $UV_{254}$ were high to over 90%, and independent of temperature and coagulant.

  • PDF

Effects of Pressure and Pressing Time on the Properties of Isolated Soy Protein-Tofu During Compressing Process (압착무게와 압착시간이 분리대두단백 두부의 특성에 미치는 영향)

  • 김동원;김우정
    • The Korean Journal of Food And Nutrition
    • /
    • v.6 no.4
    • /
    • pp.301-306
    • /
    • 1993
  • Effects of pressure and pressing time of soyprotein-CaSO4 coagulates on the yield, water holding capacity and textural characteristics of SPI (soy protein isolated) tofu were investigated. The tofu was prepared by addition of CaSO4 into SPI suspension at 9$0^{\circ}C$ and then compressed. As the compressing pressure increased from 8.66g /cm2 to 49.43g /cm2, the volume yield and moisture absorbed on filter paper were decreased and the textural properties of hardness, adhesiveness, cohesiveness and gumminess were increased. Increase in hardness and gumminess were more significant at high pressure than those at low pressure.

  • PDF