• 제목/요약/키워드: Co-contamination

검색결과 451건 처리시간 0.029초

이산화탄소 지중저장의 환경 관리를 위한 미국과 유럽연합의 법·제도 현황과 시사점 (Status and Implications of Regulatory Frameworks for Environmental Management of Geologic CO2 Storage in USA and EU)

  • 장은선;윤성택;최병영;정다위;강헌
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권6호
    • /
    • pp.9-22
    • /
    • 2012
  • Though geologic storage of $CO_2$ (GS) is considered as an attractive technological option to enormously reduce greenhouse gases emission into the atmosphere, many concerns on potential environmental and health risks associated with $CO_2$ leakage have been raised. In particular, groundwater contamination due to the brine displacement by a pressure build-up and the acidification by leaked $CO_2$ is paid a special attention. Therefore, integrated regulatory frameworks have been established by law in many countries to secure the permanent containment of injected $CO_2$. Regulatory frameworks deal with entire processes of GS, including site selection, monitoring and post-closure environmental management. This review paper provides a summary of regulatory frameworks in USA (U.S. EPA Geologic Sequestration Rule) and EU (Geologic $CO_2$ Sequestration Directive). The regulatory framework to properly address environmental issues should be established for the deployment of CCS projects in Korea.

변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/PCDFs 오염수준 및 이성체 분포 (Contamination level and congener profiles of PCBs, Co-PCBs and PCDD/DFs in transformer insulation oil samples)

  • 김경수;김종국;신선경;김경심;송병주
    • 분석과학
    • /
    • 제19권3호
    • /
    • pp.263-271
    • /
    • 2006
  • 변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/Fs를 GC/ECD와 HRGC/HRMS를 이용하여 정량한 결과 각각 N.D.~77.3 ppm, 0.0863~2.49 ppm과 N.D.~0.00241 ppm으로 검출되었다. WHO-TEQ 농도는 Co-PCBs가 23.3~600 pgTEQ/g, PCDD/Fs가 N.D.~128 pgTEQ/g (${\Sigma}Co$-PCBs+PCDD/Fs은 24.4~728 pgTEQ/g)으로 검출되어, 총 TEQ 농도 중 PCDD/Fs가 차지하는 비율은 12% 이하였으나, 변압기 절연유 중에 미량의 다이옥신이 존재하는 것으로 나타났다. 총 10개의 시료 중 4개의 시료에서 현행 기준인 2 ppm을 초과하였으며, 시료에 따라서 Aroclor 1242, 1248, 1254 및 1260이 단품 혹은 혼합품의 형태로 포함되어 있었다. 또한 Co-PCBs와 PCDD/Fs의 농도사이에 상관성이 나타났으나 (P<0.003), 변압기의 제작년도와 농도사이에 상관성은 나타나지 않았다. Co-PCBs 이성체 분포에 있어서 non-ortho 치환 이성체에 비해 mono-ortho 이성체가 높은 비율을 차지하였으며, PCB-118 이성체가 모든 시료에서 42% 이상으로 가장 높은 비율을 차지하였다. PCDD/Fs 이성체 분포에 있어서는 OCDD가 53% 이상으로 다른 이성체에 비해 높은 비율을 차지했다. 또한 일부 시료 중 Co-PCBs의 이성체패턴은 환경 대기시료 뿐만 아니라 PCBs 제품인 Aroclor와 유사한 패턴을 나타내어, 변압기 절연유가 대기 중 PCBs의 오염원 중 하나라는 것이 시사되었다.

Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석 (Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter)

  • 장지용;정문택;송종남;하재준;한재복
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2018
  • 단창형의 Geiger-Muller 계수관을 이용한 표면오염검사에서 베타선을 측정하기 위해 외부로 노출된 디텍터를 보호하는 방법으로 랩을 사용하고 있는데 이 방법이 측정계수율과 교정인자에 미치는 영향을 분석하고 방사선작업종사자에게 과도한 랩의 사용은 베타선의 측정값에 영향을 줄 수 있음을 인지시켜주고자 하였다. 실험방법은 3 KBq, 1.5 KBq, 0.3 KBq의 에너지가 다른 베타선을 이용하여 랩 두께에 따른 베타선 측정계수율과 교정인자의 변화를 비교 분석하였다. 실험 대상으로는 2012년 3월 한국인정기구 (KOLAS) 인증을 받은 교정센터에서 보유한 단창형의 Geiger-Muller 계수관을 대상으로 하였으며, Cl-36(Chlorine)과 Sr-90(Strontium)을 베타선 방사선원으로 사용하였다. 측정계수율은 랩 두께가 증가할수록 감소함을 확인 할 수 있었고 교정인자는 랩 두께가 증가할수록 증가하는 것을 알 수 있었다. 측정계수율의 감소와 교정인자의 변화는 기기지시값의 정확도를 감소시킬 수 있지만 디텍터의 오염 및 손상 또한 베타선 측정에서 중요한 영향을 주기 때문에 어느 정도 두께의 랩을 사용함이 가장 효과적인지 알아볼 필요성이 있다. 측정계수율과 교정인자의 낮은 변화율을 보여주는 두께의 랩을 사용한다면 디텍터를 보호하면서 베타선의 측정값에도 영향을 최소한으로 줄 수 있을 것으로 사료된다.

고탁도 해역의 온배수 활용을 위한 탁도저감시스템 적용에 대한 연구 (A Study on the Application of a Turbidity Reduction System for the Utilization of Thermal Wastewater in High Turbidity Zones)

  • 하신영;오철;국승기
    • 해양환경안전학회지
    • /
    • 제24권7호
    • /
    • pp.916-922
    • /
    • 2018
  • 는 열교 환기를 세척할 때 최근 신재생에너지의무화제도(RPS: Renewable Portfolio Standard)대상 신재생에너지 항목에 발전소 온배수가 신재생에너지공급인증서(REC:Renewable Energy Certificate)의 수열에너지(가중치 1.5)로 추가되어 온배수 열원에 대한 가치가 높아졌다. 본 연구에서는 고탁도지역 온배수의 직접적인 활용을 위한 방안으로 히트펌프시스템 내 탁도저감장치를 도입하여 열교환기에 가해지는 오염물질의 저감 효과를 확인해보기 위해 한 달 동안 실증테스트를 실시하였다. 실험결과 탁도 저감효과가 80 % 이상으로 고탁도 지역의 온배수 활용을 위한 방안으로 탁도저감장치의 적용가능성을 확인 할 수 있었다. 또한 탁도저감시스템에 따른 열교환기의 오염도 저감 효과를 검증하기 위해 30일간 운전한 열교환기를 해체하여 분석해본 결과 탁도저감시스템을 거친 열교환기보다 그렇지 않은 열교환기의 오염정도가 높은 것을 확인하였다. 열교환기에 유입된 오염물질(스케일)을 분석해본 결과 주로 $SiO_2$, $Na(Si_3Al)O_8$, $CaCO_3$, NaCl 성분의 광물이 검출되었는데 이는 높은 탁도로 인해 해양퇴적토가 열교환기에 유입된 것으로 분석되었다. 그 외에도 소량이지만 $TiO_2$, MnO, $Cr_2O_3$가 검출되었다. 이는 열교환기를 세척할 때 열교환기 재료로부터 기인한 중금속이 소량 용출된 것으로 판단된다.

산화제 제어 확산화염의 화염구조 및 NO 생성 특성에 관한 수치해석적 연구 (Numerical Study on Flame Structure and NO Formation Characteristics in Oxidizer-Controlled Diffusion Flames)

  • 이창언;한지웅
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.742-749
    • /
    • 2002
  • Numerical Study with detailed chemistry has been conducted to investigate the flame structure and NOx formation characteristics in oxygen -enhanced(CH$_4$/O$_2$-$N_2$) and oxygen-enhanced-EGR(CH$_4$/O$_2$-$CO_2$) counter diffusion flame with various strain rates. A small amount of $N_2$is included in oxygen-enhanced-EGR combustion, in order to consider the inevitable $N_2$contamination by $O_2$production process or air infiltration. The results are as follows : In CH$_4$/O$_2$-$CO_2$flame it is very important to adopt a radiation effect precisely because the effect of radiation changes flame structure significantly. In CH$_4$/O$_2$-$N_2$flame special strategy to minimize NO emission is needed because it is very sensitive to a small amount of $N_2$. Special attention is needed on CO emission by flame quenching, because of increased CO concentration. Spatial NO production rate of oxygen-enhanced combustion is different from that of air and oxygen-enhanced-EGR combustion in that thermal mechanism plays a role of destruction as well as production. In case CH$_4$/O$_2$-$CO_2$flame contains more than 40% $CO_2$it is possible to maintain the same EINO as that of CH$_4$/Air flame with accomplishing higher temperature than that of CH$_4$/Air flame. EINO decreases with increasing strain rate, and those effects are augmented in CH$_4$/O$_2$flame.

산화제 제어 화염의 구조 및 NO 생성 특성 (Structure and NO formation characteristics of oxidizer-controlled diffusion flames)

  • 한지웅;이창언
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.185-190
    • /
    • 2001
  • Numerical Study with detailed chemistry has been conducted to investigate the flame structure and NOx formation characteristics in oxygen-enhanced$(CH_4/O_2-N_2)$ and oxygen-enhanced-EGR$(CH_4/O_2-CO_2)$ counter diffusion flame with various strain rates. A small amount of $N_2$ is included in oxygen-enhanced-EGR combustion, in order to consider the inevitable $N_2$ contamination by $O_2$ production process or air infiltration. The results are as follows : In $CH_4/O_2-CO_2$ flame it is very important to adopt a radiation effect precisely because the effect of radiation changes flame structure significantly. In $CH_4/O_2-N_2$ flame special strategy to minimize NO emission is needed because it is very sensitive to a small amount of $N_2$. Special attention is needed on CO emission by flame quenching, because of increased CO concentration. Spatial NO production rate of oxygen-enhanced combustion is different from that of air and oxygen-enhanced-EGR combustion in that thermal mechanism plays a role of destruction as well as production. In case $CH_4/O_2-CO_2$ flame contains more than 40% $CO_2$ it is possible to maintain the same EINO as that of $CH_4/Air$ flame with accomplishing higher temperature than that of $CH_4/Air$ flame. EINO decreases with increasing strain rate, and those effects are augmented in $CH_4/O_2$ flame. Complementary study is needed with extending the range of strain rate variation.

  • PDF

틸팅열차의 전과정평가를 통한 철도차량 환경성 개선방안연구 (Study on Improving the Environmental Performance of a Railway Vehicle through a Life Cycle Assessment of the Tilting Train)

  • 이철규;김용기;이재영;최요한;김초영
    • 한국철도학회논문집
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 국제환경규제는 제품사용단계에서 발생한 환경오염에 대한 사후처리방식에서 설계단계에서 사전환경 오염차단과 자원순환으로 전환하고 있다. 사전환경오염 차단도구로는 제품의 환경성능을 정량화하고 이러한 정보를 객관적으로 제공하는 환경성 인증제도가 활용되고 있으며 유럽에서는 이를 구매단계부터 적용하고 있다. 본 연구에서는 국내 최초로 틸팅열차를 대상으로 ISO 14025기준과 환경부 환경성적표지제도의 작성지침에 따라 전과정평가를 수행하였으며 그 결과를 제시하였다. 틸팅열차 1편성의 생애주기 온실가스 총배출량은 $3.54{\times}10^7kgCO_2eq.$로 분석되었으며 이는 유럽의 동일한 철도차량 온실가스 배출량과 비교할때 높은 수치이다. 차량별 온실가스배출량 분석결과 동력분산식임에도 Mcp차량의 배출량이 상대적으로 많았으며 차체의 배출량이 대차보다 높음을 확인하였다.

전주시 도로변 퇴적물의 중금속 오염 특성 (Characteristics of Heavy Metal Pollution in Contaminated Roadside Sediments in Jeonju City, Korea)

  • 조규성
    • 한국지구과학회지
    • /
    • 제24권8호
    • /
    • pp.711-720
    • /
    • 2003
  • 전주시 도로변 퇴적물의 중금속 오염을 평가하고 특성을 알기 위해 2002년 여름과 겨울 두 차례에 걸쳐 67곳에서 134개의 시료를 채취했다. 이들 시료를 Thompson and Wood (1982)와 Tessier et al. (1979)의 방법으로 화학처리한 후 Cd, Co, Cr, Cu, Ni, Pb, Zn, Mn등의 원소를 분석했다. 전주 도로변 퇴적물에 함유된 Zn, Cu, Pb, Cd의 함량은 서울의 도로변 토양, 먼지, 하수 슬러지에 함유된 것 보다 낮지만 세계 여러 나라에서 제시하는 토양 중 환경기준값을 초과했으며 자연 토양 중의 함량 보다 2-7배 초과한 값이다 산업지역, 상업지역, 주거지역으로 구분해 분석한 결과 전반적으로 산업지역에서의 중금속 함량이 약간 높고(특히 Cr, Ni, Pb, Zn)오염지수도 높다. 상업지역과 주거지역간의 중금속 오염 정도는 비슷하며 산업지역이 아니라도 특정 금속 가공업체나 자동차 정비 관련 업체가 위치해 있는 곳은 오염이 심하다. 연속추출 결과 중금속 원소의 존재 형태는 Pb, Zn, Mn등은 주로 탄산염 광물과 수반되거나 Fe-Mn산화물과 수반된 형태로 존재하고, Cu는 유기물과 함께 존재하는 비율이 높다. 그러나 전체적으로 규산염광물과 수반된 형태로 존재하는 비율이 50% 이상을 차지한다. 따라서 서울 지역에 비해 인위적 오염의 정도가 낮은 편이지만, Cd, Co, Ni, Pb, Zn, Mn등의 원소가 탄산염 형태로 존재하는 비율이 높기 때문에 오염원으로서의 가능성이 높다.

삼산제일광산 광미 내 유해 미량원소의 오염 및 이동도 (Contamination and Mobility of Toxic Trace Elements in Tailings of Samsanjeil Mine)

  • 연규훈;이평구;염승준;최상훈
    • 자원환경지질
    • /
    • 제38권4호
    • /
    • pp.451-462
    • /
    • 2005
  • 경상남도 고성군 삼산제일 동광산 주변 지역에 방치되어 있는 약 28만 톤의 광미를 포함한 광산폐기물에 의한 주변 환경의 오염정도를 평가하기 위하여 광미, 폐광석, 주변토양을 대상으로 화학분석(전함량분석, 토양오염공정시험법, 연속추출)을 통하여 유해 미량원소의 함량 및 이동도를 알아보았다. 광미 내 유해 미량원소의 전함량을 배경토양과 비교 했을 때, 부화도가 높은 순서는 Cu(14.0배)$\gg$As(3.6배)>Co(3.1배)>Zn(2.1배)=Pb(2.1배)>Cd(1.6배) 순이다. 광미 내 유해 미량원소의 존재형태(fraction I+fraction II)를 알아본 견과, 이동이 기능한 존재형태가 많은 순서는 $Zn(29.0\%)>Cu(12.3\%)>Pb(9.6\%)>Cd(3.0\%)>As=Co(0.0\%)$ 순으로 나타난다. 광미, 폐광석, 주변토양 내 유해 미량원소의 함량 및 존재형태를 고려해 볼 때, 주변 환경을 오염시킬 가능성이 있는 유해 미량원소는 구리(Cu)와 아연(Zn)인 것으로 판단된다. 한편, 광미 내 유해 미량원소의 함량을 네덜란드의 기준과 비교한 결과, Cu를 제외한 나머지 원소가 환경에 미치는 영향은 없을 것으로 추정되었다.

토양 탱크에서 흡수 알코올과 비흡수 알코올을 이용한 벤젠-비수용상액체 제거 연구 (Removal of Benzene-Nonaqueous Phase liquid(NAPL) in Soil Tank by NAPL Swelling and Non-swelling alcohols)

  • 송충현;정승우
    • 유기물자원화
    • /
    • 제17권3호
    • /
    • pp.40-47
    • /
    • 2009
  • 토양으로 유출된 비수용상액체(nonaqueous phase liquid; NAPL)의 제거를 위한 알코올 희석 세정공정의 기술개발을 위하여 3-D 토양탱크에서 NAPL 흡수 및 비흡수 알코올 단독 또는 공기 동시 주입공정에 의한 벤젠 NAPL 제거 효과를 평가하였다. 37L 규모의 토양탱크에 729mL의 벤젠을 주입하고 70%에탄올 (NAPL 비흡수 알콜)과 40%이소 프로판올(NAPL 흡수 알콜)을 탱크 하부에 설치된 주입정에 주입하고 상부의 추출정으로부터 자유상 NAPL 및 수용액을 추출하였다. 그리고 알코올 주입과 공기를 동시 주입하여 기존 토양칼럼실험에서 확인된 공기 동시주입시 화학세정 증대 효과를 아울러 평가하였다. 70% 에탄올 및 40% 이소-프로판올에 의한 토양탱크 세정공정 결과 전체 벤젠 제거율의 과반수는 자유상 NAPL 형태로 제거되었다. 알코올의 NAPL 흡수 특성에 따라 벤젠 제거 특성이 현저히 다르게 나타난 토양칼럼결과와 달리 3-D공정에서는 알코올 NAPL 흡수특성의 영향이 매우 적게 나타났다. 70%에탄올과 공기 동시 주입에 의한 벤젠 제거 증대 효과는 3-D 토양탱크 실험결과에서도 여전히 확인되었다. 그러나 NAPL 흡수 알코올인 40% 이소-프로판올은 공기 동시 주입에 의한 벤젠 제거 증대효과가 여전히 미미하게 나타났다. 3-D 토양탱크 실험결과 화학세정공정에 의한 NAPL제거에 있어 가장 중요한 인자는 추출정의 NAPL 및 유출수 추출능력이었다. 즉 토양내 효과적인 NAPL 정화를 위해서는 화학적인 작용에 의하여 이동된 자유상 NAPL 및 수용액을 밖으로 효율적으로 추출할 수 있는 공정이 필요하다.