• Title/Summary/Keyword: Co-60

Search Result 4,354, Processing Time 0.041 seconds

Effect of Modified Atmosphere Packaging on Preservation of Pumpkin Rice Cake (호박 설기떡의 저장성에 미치는 변형기체포장의 영향)

  • Moon, Ki-Bok;Kim, Hwan-Ki;An, Duck-Soon;Lee, Dong-Sun
    • Food Science and Preservation
    • /
    • v.17 no.6
    • /
    • pp.908-913
    • /
    • 2010
  • Modified atmosphere packaging (MAP) was evaluated for the storage of pumpkin rice cake as a means of preserving quality and extending shelf-life. Retail-sized amounts of rice cake were packaged in trays under different modified atmosphere conditions (air, vacuum, 60% $CO_2$/40% $N_2$ and 100% $CO_2$) using gas-barrier plastic film; control was in air-permeable stretch wrap. The packages were stored at $20^{\circ}C$ with periodical measurement of package atmosphere and cake quality attributes. The modified atmosphere packages of 60% $CO_2$/40% $N_2$ and 100% $CO_2$ inhibited the growth of molds/yeasts completely and significantly retarded the growth of aerobic bacteria. All the packages except that of 100% $CO_2$ showed the reduction of internal $O_2$ concentration and increase of the $CO_2$ with storage time due to the microbial activity. There has been slight decrease of $CO_2$ concentration for 60% $CO_2$/40% $N_2$ and 100% $CO_2$ packages just after start of the storage possibly due to dissolution of headspace $CO_2$ into the cake. Any MAP conditions did not affect the retrogradation of the rice cake. Surface color of the cake within affordable microbial quality limit was not affected significantly by packaging conditions.

Disposal of CO in CO-Poisoning Dogs (일산화탄소중독견(一酸化炭素中毒犬) 체내(體內)에서의 일산화탄소처리능(一酸化炭素處理能)에 관(關)하여)

  • Ryo, Ung-Yun;Kang, Bann
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1968
  • The Present study attempted to analyze the fate of CO diffused into the circulating blood through the alveoli. Dogs were induced to CO poisoning by rebreathing CO gas mixture contained in Krog's spirometer, by closed circuit method, for 60 minutes. The spirometer was filled initially with 282 ml of CO and 20 liters of air and oxygen, so the composition of gases were arranged as 1.4% in CO and 50% in $O_2$ at the begining of the rebreathing. Oxygen was added corresponding to the utilization of $O_2$ by the animal in proceeding of the experiment. At 60th minutes of CO rebreathing, the concentration of CO in arterial blood and in mixed venous blood were analysed and compared with each other after the CO contents were corrected with the hematocrit measured in the arterial and mixed venous blood. The distribution of CO gas to other tissues was estimated by the analysis of CO diffused into the cystic bile and into the peritoneal gas pocket which was formed by injection of 300 ml air into the peritoneal cavity prior to the CO gas rebreathing. The blood volume was measured by dilution method using $^{51}Chromium$ tagged red cells. CO amount vanished in the animal body was calculated by subtraction of total CO content in blood stream and the CO remained in closed circuit breathing system from the CO amount given to the breathing system at the begining of the experiment. Results obtained are summarized as follows: 1. The content of CO corrected by the hematocrit value was slightly less in mixed venous blood than in arterial blood. The amount of CO diffused into the cystic bile and into the peritoneal cavity was averaged to 0.1% and 0.4% of the CO amount in 100 ml of blood, respectively. 2. For 60 minutes of CO rebreathing, CO-hemoglobin saturation reached about 77% at the 60th minutes, CO amount vanished in the experimental animal averaged 36.1 ml/dog/hr., or 21% of the total CO volume in the blood stream. The average vanishing rate of CO during 60 minutes of CO rebreathing per kg of body weight was 2.71 ml/hr. Production of CO measured in ten dogs under hypoxic condition averaged 0.023 ml/kg/hr. The major part of the CO vanished in the dogs seemed to be oxidized to $CO_2$ by various tissues of the animal. The conclusion might be delivered as such oxidation of CO to $CO_2$ by animal tissues can play a role in part of the process of recovery and protection of animal from CO-poisoning.

  • PDF

Fabrication and $^{60}Co$ Gamma Induced Damage of Plastic Scintillators (플라스틱 섬광체의 제작과 $^{60}Co$ $\gamma$-선에 의한 방사선 손상)

  • Kim, Sung-Hwan;Nam, Seung-Hee;Cheon, Jong-Kyu;Kim, Wan;Kang, Hee-Dong;Kim, Do-Sung;Lee, Woo-Gyo;Doh, Sih-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.350-356
    • /
    • 2000
  • The optimum composition ratios of primary solute(p-terphenyl) and secondary solute(popop) have been investigated in order to fabricate plastic scintillator with higher light output and less radiation damage. The radiation damage induced by $^{60}Co$ $\gamma$-irradiation depends on mainly the concentration of secondary solute. The spectral range of the luminescence was $400{\sim}450\;nm$, its peak emission appeared at 415 nm. The transmittance and the light output were not changed by radiation damage up to $1{\times}10^4\;Gy$ irradiation with $^{60}Co$ $\gamma$-rays.

  • PDF

Distribution Characteristics of Radionuclies (60Co, 137Cs) During the Melting of Radioactive Metal Waste (방사성 금속폐기물의 용융시 방사성 핵종(60Co, 137Cs)의 분배특성)

  • Min, Byung Youn;Choi, Wang Kyu;Oh, Won Zin;Jung, Chong Hun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.627-632
    • /
    • 2007
  • A fundamental study on the melt decontamination of metal wastes generated by dismantling the nuclear facility, the melting of metal wastes such as stainless steel and carbon steel have been carried out to investigate the distribution phenomena of the radioisotopes such as $^{60}Co$ and $^{137}Cs$ into the ingot, slag and dust phases by using the various slag types, slag concentration and basicity in an arc furnace. The $^{60}Co$ remained homogeneously in the ingot phase above 90 % and it was barely present in the slag below 10 %. The effect of the slag composition on the distribution for Co-60 was not considerable, but a basic slag former with high fluidity showed effective. $^{137}Cs$ was completely eliminated from the melt of the stainless steel as well as the carbon steel and distributed to the slag and the dust phase.

Combustion Kinetics of Pulverized Indian Coal-Char in Different CO2-O2 Mixture Isothermally (여러 CO2-O2 혼합기체에서 인도산 분말숯의 등온 연소반응)

  • Saravanan, V.;Shivakumar, R.;babu, P. Niruguna;Ramakrishna
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.635-639
    • /
    • 2009
  • Experimental work was carried out to study the combustion kinetics of the Indian coal-char in the varying mixture of carbon dioxide-oxygen ($CO_2-O_2$). The coal sample was pulverized and sieved to less than 58 microns and charred using volatile furnace by passing the nitrogen gas. The experiments were carried out using the Thermo Gravimetric Analyzer (TGA-50) at CPRI, Bangalore, different proportions of ($CO_2-O_2$) gas was allowed in to the TGA-50 (80-20, 60-40, 40-60, 20-80) mole basis were used to study the combustion kinetics of coal Isothermally, kinetic parameters like Activation energy (E) and the pre-exponential factors (A) are calculated using the unification approach and modified Arrhenius equation.

Study on the Effectiveness of some Decontamination Agents against Skin Contamination of $^{137}Cs$ and $^{60}Co$ (제염제의 $^{137}Cs$$^{60}Co$에 의한 피부오염의 제염효과에 관한 연구)

  • Chon, Je-Keun;Ji, Pyung-Kook;Kwak, Sang-Soo;Kim, Byung-Tae;Park, Chong-Mook
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.7-15
    • /
    • 1998
  • In order to evaluate the effectiveness of some decontamination agents against skin contamination of $^{60}Co$ and $^{137}Cs$, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin , $^{60}CoC1_2$ and $^{137}CsCl$ were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, KAERICON which was developed for decontamination of radionulides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-tay detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of initial amounts of $^{137}Cs$ and $^{60}Co$, respectively, were panerated into the skin. In the experiment to remove the residual radioactivity fixed on the skin, KAERICON showed the decontamination rates up to 52.1%(decontamination factor of 2.1) and IOCON showed the equivalent decontamination rate (decontamination factor 1.9) for $^{137}Cs$. However, IOCON and CHARCON showed the poor decontamination rates of less than 20%(decontamination factor of 1.2) for $^{60}Co$, and KAERICON showed the poor decontamination rate (decontamination factor 1.1) for $^{60}Co$. For TRICON, the decontamination factors were 1.6 to 1.8 for $^{137}Cs$, and 1.0 to 1.2 for $^{60}Co$, respectively.

  • PDF

Preparation of Cellulose Nanoparticles Loaded with Retinyl Palmitate (레티닐 팔미테이트가 봉입된 셀룰로오스 나노입자의 제조)

  • Lee, Jeong-Soon;Ma, Sang-Chol;Kang, Ki-Choon;Pyo, Hyeong-Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.3
    • /
    • pp.175-181
    • /
    • 2008
  • Cellolose nanoparticles loaded with retinyl palmitate were prepared by modified spontaneous emulsification solvent diffusion method. We used polysorbate 20, polysorbate 60, and PPG-26-Buteth-26/PEG-40 Hydrogenated castor oil as dispersion medium. The optimum condition for particle size of cellulose nanoparticles was 1w/v% ethyl cellulose with, 3w/v% polysorbate 60 solution. And The optimum condition for leading amount of retinyl palmitate of cellulose nanoparticles was 2w/v% ethyl cellulose with 1w/v% polysorbate 60 solution. Also, we found that this optimum condition can be applicable to other active compounds.

Soil-to-Plant Transfer Factors and Migration of Radionuclides Applied onto Soli during Growing Season of Cucumber (오이의 재배기간중 처리한 방사성 핵종의 토양;작물체간 전이계수 및 지하이동)

  • Choi, Yong-Ho;Park, Hyo-Kook;Kim, Sang-Bog;Choi, Geun-Sik;Lee, Jeong-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.304-310
    • /
    • 1997
  • In greenhouse, a mixed solution of Mn-54, Co-60, Sr-85 and Cs-137 was applied to the soil of culture boxes 2 days before sowing cucumber and at 4 different times during its growth for measuring their transfer factors (TFs) for fruit and migration in soil. TFs varied with radionuclide, application time and harvest time by factor of up to about 60. Variations in TFs with application time showed different patterns among radionuclides. TFs decreased on the whole in the order of Sr-85 > Mn-54 > Co-60 > Cs-137. TFs of Mn-54, Co-60 and Cs-137 mixed with topsoil before sowing were a little higher than those for the soil-surface application made at an early growth stage while no difference in Sr-85 TF was found. After harvest, soil concentrations of the radionuclides applied at an early growth stage were examined. They decreased with increasing soil depth and 80${\sim}$99% of the radioactivity remained in the top 3cm. Soil pemeation of the radionuclides migration decreased in the order of Sr-85 > Mn-54 > Co-60 > Cs-137. The present data can be utilized in estimating radionuclide concentration in cucumber fruit, taking proper measures for its harvest and consumption and designing the best way of soil decontamination following an radioactive deposition during the cucummber growing season.

  • PDF

Trouble in Source Driving System of a $^{60}Co$ Teletherapy Unit ($^{60}Co$ 치료장치의 선원 구동상의 문제점)

  • Kang, Wee-Saing
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.65-69
    • /
    • 1986
  • An asymmetry in dose profile of a $^{60}Co$ teletherapy unit was found by means of water-phantom measurement. The reason of that trouble was confirmed to be the abnormal 'ON' position of the source, which is resulted from the high friction between contiguous surfaces of the spring for driving the source to 'OFF' position. Lubrication in the spring improved the mobility a little, but was not a radical repair. The radical repair was to replace the old spring by new one. Periodic maintenance for source driving system and periodic measurement of field symmetry are required for prevention of abnormal 'ON' position of $^{60}Co$ source.

  • PDF