• 제목/요약/키워드: Co depletion layer

검색결과 27건 처리시간 0.025초

진공 플라즈마 용사법을 통해 형성된 NiCoCrAlY 오버레이 코팅의 반복 산화 거동 (Cyclic Oxidation Behavior of Vacuum Plasma Sprayed NiCoCrAlY Overlay Coatings)

  • 유연우;남욱희;박훈관;박영진;이성훈;변응선
    • 한국표면공학회지
    • /
    • 제52권6호
    • /
    • pp.283-288
    • /
    • 2019
  • MCrAlY overaly coatings are used as oxidation barrier coatings to prevent degradation of the underlying substrate in high temperature and oxidizing environment of the hot section of gas turbines. Therefore, oxidation resistance in high temperature is important property of MCrAlY coatings. Also, coefficients of thermal expansion (CTE) of MCrAlY have middle value of that of Ni-based superalloys and oxides, which have the effect of preventing the delamination of the surface oxides. Cyclic oxidation test is one of the most useful methods for evaluating the high temperature durability of coatings used in gas turbines. In this study, NiCoCrAlY overlay coatings were formed on Inconel 792(IN 792) substrates by vacuum plasma spraying process. Vacuum plasma sprayed NiCoCrAlY coatings and IN 792 susbstrates were exposed to 1000℃ one-hour cyclic oxidation environment. NiCoCrAlY coatings showed lower weight gain in short-term oxidation. In long-term oxidation, IN 792 substrates showed higher weight loss due to delamination of surface oxide but NiCoCrAlY coatings showed lower weight loss. X-ray diffraction (XRD) analysis showed α-Al2O3 and NiCr2O4 was formed during the cyclic oxidation test. Through cross-section observation using scanning electron microscopy (SEM) and electron back scatter diffraction (EBSD) analysis, thermally grown oxide (TGO) layer composed of α-Al2O3 and NiCr2O4 was formed and the thickness of TGO increased during 1000℃ cyclic oxidation test. β phase in upper side of NiCoCrAlY coating was depleted due to oxidation of Al and outer beta depletion zone thickness also increased as the cyclic oxidation time increased.

LCA기법을 이용한 랜탈 재제조품의 환경성 평가 (Environmental Evaluation for the Remanufacturing of Rental Product Using the LCA Methodology)

  • 곽인호;황용우;박광호;박지형;설소영;신화정;양은혁;민곤식
    • 대한환경공학회지
    • /
    • 제38권11호
    • /
    • pp.611-617
    • /
    • 2016
  • 사용 후 제품을 회수하여 완전 해체하고 부품들을 세척, 수리, 또는 새로운 부품으로 교체하여 재조립함으로써 신품과 동일한 성능 수준으로 재 제품화 하는 재제조는 천연자원과 에너지 사용의 저감 등 자원순환 측면에서의 환경적 개선효과가 뛰어나 자원 측면에서 주목받고 있다. 재제조는 뛰어난 환경개선 효과 및 자원보존으로 인해 우리나라에서 많은 연구가 수행되어왔으며, 현재 자동차 부품, 프린터 토너 및 카트리지를 중심으로 재제조가 이루어지고 있다. 하지만 코어의 상태가 양호한 상태로 반환되어 재제조 공정을 거쳐 새 제품과 동일한 상태의 재제조품 생산이 가능한 렌탈 제품은 아직까지 활성화 되어있지 않다. 따라서, 본 연구에서는 LCA 기법을 이용해 렌탈 제품 중 하나인 공기청정기 신품과 재제조 제품의 환경성평가를 수행하였으며, 이를 통해 렌탈 제품 신품 대비 재제조품의 환경적 개선 효과를 정량적으로 분석하였다. 분석결과 공기청정기 1대 재제조 시 환경영향은 신품대비 약 20.7% 감소하는 것으로 나타났다. 환경과 관련된 영향범주 중 오존층 파괴(ODP)가 94% 감소하여 가장 큰 효과가 있는 것으로 나타났으며, 공기청정기의 수명주기에서 원료 추출 단계에서는 자원고갈(ADP) 및 지구온난화(GWP)에 대한 환경개선 효과가 가장 큰 것으로 나타났다.

전과정평가(LCA)를 이용한 친환경 인증 건축물과 일반 건축물의 환경영향 비교 사례 연구 (Comparison of Environmental Impacts of Green and Traditional Buildings using Life Cycle Assessment)

  • 홍태훈;정광복;지창윤
    • 한국건설관리학회논문집
    • /
    • 제15권3호
    • /
    • pp.58-65
    • /
    • 2014
  • 본 연구는 국내에서 시행중인 친환경 건축물 인증제도 (G-SEED)에 따른 환경영향 저감 효과를 파악하는 것을 목적으로 한다. 이를 위하여, G-SEED 인증을 받은 초등학교 건축물과 인증을 받지 않은 일반 초등학교 건축물을 대상으로, 전과정평가 방법론을 이용하여 4가지 환경영향범주 (지구온난화, 오존층파괴, 산성화, 부영양화)에 따른 환경영향을 평가하고, 결과를 비교하였다. 건축물에 대한 환경영향평가는 자재생산, 자재운송, 시공, 운영단계를 포함하였으며, 운영기간은 40년으로 설정하였다. 두 건축물의 단위연면적당 환경영향을 비교한 결과, 일반 초등학교 건축물에 비해 친환경 인증 초등학교 건축물의 환경영향이 큰 것으로 나타났다. 예를 들어, 친환경 인증 초등학교 건축물의 지구온난화지수는 3.751 $t-CO_2eq./m^2$ 로 산출된 반면, 일반 초등학교 건축물의 지구온난화지수는 3.282 $t-CO_2eq./m^2$ 로 산출되어, 약 12.5% 크게 나타났다. 이는 G-SEED 인증이 4가지 측면에서의 환경영향의 저감을 보장하지 못한다는 것을 의미한다. 따라서 건축물로부터 발생하는 환경영향의 저감을 달성하기 위해서는 G-SEED에 대한 보완이 필요하다.

An Application of Optimum Heat Exchanger for the Grasp on Performance Characteristics of $NH_3$ Refrigeration System

  • 허옥남;권일욱;홍석주;김재열;이종인;전상신;하경수;이승재;박찬수;정송태
    • 한국공작기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.69-74
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants is to be restricted due to the depletion of ozone layer, this experiment applies the $NH_{3}$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa by 50kPa and for degree of superheat from $0^{circ}$ to $1^{circ}$ by $10^{circ}$ at each condensing pressure. As a result of experiment, 1) As degree of superheat increased, evaporating pressure of the compressor decreased so equilibrium temperature decreased. And specific volume of refrigerant vapors increased so refrigerant mass flow and heat load of the evaporator decreased. 2) An influence of change of condensing pressure on heat load of the evaporator was insignificant. 3) With the identical degree of superheat, change of compressed temperature was insignificant according to each condensing pressure, so there was little change in enthalpy.4) when the degree of superheat is $0^{circ}$C at each condensing pressure, the refrigeration system has the hi띤est performance.

CFRP/GFRP 적층복합재의 두께가 혼합모드 균열거동과 AE에 미치는 영향 (The Effect of the CFRP/GFRP Composite Thickness on AE Characteristics and Mixed Mode Crack Behavior)

  • 윤유성;김다진솔;권오헌
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.9-14
    • /
    • 2014
  • Recently many efforts and researches have been done to cope with industrial facilities that require a low energy machines due to the gradual depletion of the natural resources. The fiber-reinforced composite materials in general have good properties and have the proper mechanical properties according to the change of the ply sequences and fiber distribution types. However, in the fiber-reinforced composite material, there are several problems, including fiber breaking, peeling, layer lamination, fiber cracking that can not be seen from the metallic material. Particularly, the fracture and delamination are likely to be affected by the thickness of the stacking laminates when the bi-material laminated structure is subjected to a load of the mixed mode. In this study, we investigated the effect of the thickness ratio of the difference in the CFRP/GFRP bi-material laminate composites by measuring the cracking behavior and the AE characteristics in a mixed mode loading, which may be generated in the actual structure. The results show that the thickness of the CFRP becomes more thick, the mode I energy release rate becomes a larger, and also the influence of mode I is greater than that of mode II. In addition, AE amplitude which shows the level of the damage in the structure was obtained the more damage in the CFRP with the thin thickness.

$NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구 II -열교환기 타입 변경- (The Study on Performance Characteristics of $NH_3$ Refrigeration System for Various Degree of Superheat - Part II : The Change of Heat Exchanger Type -)

  • 하옥남;권일욱;전상신;이승재;정송태;하경수;윤갑식;이종인;홍경한
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.297-302
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the $NH_3$ gas to study the performance characteristics of $NH_3$ refrigeration system by the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa and for degree of superheat from $0^{\circ}C\;to\;10^{\circ}C$ at each condensing pressure. As a result of experiment, when the degree of superheat is $0^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

스마트건설기반에서의 지반그라우팅을 위한 황토의 적용성 검토 (A Study on the Application Review of Hwang-toh for Ground Grouting Based on Smart Construction)

  • 이태세;이동혁
    • 한국지반환경공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.21-27
    • /
    • 2024
  • 석회암이 주 원료인 시멘트는 세계적으로 건설자재로 잘 활용해 왔으나, 토목건축 개발이 가속화 됨에 따라 석회암이 점차적으로 고갈이 될 것이다. 토목과 건축에 소요되는 주 재료인 시멘트는 현대에 사용량이 급증하고 있어서 미래에는 품질 좋은 석회암 자원의 고갈 또한 예상보다 이를 것이다. 그래서 축적된 기술력을 바탕으로 기존 자원이 시멘트를 대체할 건설자재로 사용이 가능하다면 고갈되어 가는 석회암 자원을 오랜 기간 동안 더 활용할 수 있을 것이다. 본 연구는 한국 지형의 면적에 표층으로 10% 가량을 형성하고 있는 황토를 건설자재로 일부 활용할 수 있는지를 판단하기 위해서 황토급결제를 개발하여 현장에 적용이 가능한지 여부를 실내시험을 통하여 증명하고자 한다.