• Title/Summary/Keyword: Clothing surface temperature

Search Result 146, Processing Time 0.022 seconds

Thermal and subjective responses by sun hats for farmer in a hot climatic chamber (서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응)

  • 김명주;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.5
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.

Transient Heat Flux Evaluation of Underwear for Protective Clothing using Sweating Manikin (발한 마네킹을 이용한 보호복용 언더웨어의 동적(Transient) 열류량 평가)

  • Park, Hye-Jun;Kim, Hyun-Jung;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.157-165
    • /
    • 2008
  • Transient thermal response of five types of underwear(cotton jersey, wool jersey, nylon jersey, cotton mesh and polyester mesh) for a protective coverall is evaluated using a sweating thermal manikin. Experimental protocol for transient thermal response of the sweating thermal manikin was also proposed. As results, it was found that steady state thermal response from sweating thermal manikin was not sensitive enough to evaluate thermal comfort of the experimental garments. However, when half time is used as an index of the heat flux change in transient thermal response, difference was found among underwear materials. Half time of cotton was the shortest and heat transfer of cotton was the fastest followed by polyester mesh, cotton jersey, nylon jersey and wool jersey. Dynamic thermal response of wool underwear was quite different from that of cotton underwear. Wool shows quite less heat flow at the initial stage, however, moisture permeability of wool was higher than cotton at the later stage. It was difficult to distinguish surface temperature difference visually using thermogram taken right before the completion of dry and wet test in steady state thermal response.

Comfort Properties of Ski Wear Using Vapor-Permeable Water Repellent Fabrics and Thermal Insulation Battings (투습발수직물과 축열보온섬유를 이용한 스키웨어의 쾌적감)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.245-254
    • /
    • 1992
  • The purpose of this study was to evaluate the mechanical thermal resistances and comfort properties of ski wear made with vapor-permeable water repellent (VPWR) fabrics and thermal insulation battings. Four types of experimental clothing were made with the combination of two VPWR fabrics (Hipora-$TM^{\circledR}$, Hipora-$CR^{\circledR}$) and two thermal insulation battings ($Viwarm^{\circledR},\;Airseal^{\circledR}$). Thermal resistances of ski wear were objectly evaluated by thermal manikin experiment ($21{\pm}\;2^{\circ}C,\;50{\pm}5\%$ R.H.,0.25 m/sec air velocity) and thermographic accessment ($2{\pm}2^{\circ}C,\;0\%$ R.H.,0.25 m/sec air velocity, and emissivity level : 1). Garment wear tests of ski wear included the measurement of the microclimate (inner temp. and relative humidity) of the experimental clothing by digital thermohygrometer and subject wear sensation using McNall's thermal comfort ratings. CBo values of experimental clothing 4 (Hipora-$CR^{\circledR}+Airseal^{\circledR}$) and 1 (Hipora-$TM^{\circledR}+Viwarm^{\circledR}$) were significantly higher than those of 2 (Hipora-$TM^{\circledR}+Airseal^{\circledR}$) and 3 (Hipora-$CR^{\circledR}+Viwarm^{\circledR}$). Thermal resistances in the points of breast, back, belly, and loin was significantly higher than those of upper am, fore arm, and shank of measuring points on the thermal manikin. According to the color map of the thermogram, the experimental clothing 4 indicated higher surface temperatures than the others showing more yellowish spots on the surface of clothing. Inner temperature of experimental clothing was not significantly different among the four types of ski wear, but relative humidities of experimental clothing were significantly different. Relative humidities of experimental clothing 1 and 3 showed higher than those of 2 and 4. Relative humidity of experimantal clothing was affected largely by the thermal resis- tance of thermal insulation batting materials. The subject wear sensation of experimental clothing 2 and 4 showed lower humidity than the others. Subject wear sensation was affected more by humidity sensation than by thermal sensation.

  • PDF

Wettability and Water Repellency of Polyester Fabrics Treated by Low Temperture Plasma (저온플라즈마처리에 의한 폴리에스테르직물의 흡수성 및 발수성 변화)

  • 권영아
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.2
    • /
    • pp.317-328
    • /
    • 1995
  • The objective of this study was to determine the effects of low temperature plasma on the surface properties of polyester fabric with respect to wettability and water repellency. Highly wettable polyester fabric surfaces were obtained by oxygen treatment. The improved wettabililty of oxygen plasma treated fabrics decreased with aging time up to 30 days, and then the wettability remained relatively constant and still exhibited significant improvement compared to that of untreated polyester. Water repellency was significantly improved by tetratfluorocarbon plasma treatment. Such an improvement appears due to introduced fluo\ulcornerrine atoms or a thin fluorocarbon film on the fiber surface. Water repellency remained constant in fact, even after 150 days.

  • PDF

A Study on Bedquilts During Sleeping on Ondol in Winter (겨울철 온돌난방에서의 이불에 관한 연구)

  • Kweon, Soo Ae;Lee, Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.291-299
    • /
    • 1993
  • In this study, bedclimate was investigated depending on three bedquilts used on ondol in winter. The environmental room condition and the ondol surface temperature were maintained $20{\pm}1^{\circ}C$, $50{\pm}3%R$. H and $30{\pm}1^{\circ}C$, respectively. The materials of the experimental quilts were not different from each other. But the weights of cotton filler were 1.5, 3.0, and 4.5kg for the bedquilts. Two healthy young women were subjected for seven hour's sleep with two replications for this study. The results are as follows. 1) The range of temperature under the mattress was higher($38.5{\sim}43.2^{\circ}C$) than that of the temperature on the mattress($32.4{\sim}37.0^{\circ}C$) or that of the temperature inside the bedquilts($30.2{\sim}34.5^{\circ}C$). The humidity inside the bedquilts was 40~73%R.H. 2) The range of bedclimate which subjects feel comfortable were $33.6{\sim}37.1^{\circ}C$ on the mattress, $30.2{\sim}33.6^{\circ}C$, 42~67%R.H. inside the bedquilts. At this range, the mean skin temperature of the subjects was was $34.7{\sim}35.6^{\circ}C$. 3) When there was heating, the weight of mattress increased due to evaporation by heat from below, while wehght of other bedding increased. 4) The lower limbs are noted to be a good representative for the prediction of the skin temperature during sleep. 5) The thicker the bedquilt, the warmer and more humid the bedquilt, which induce frequent body movement during sleep, hence inferior comfort properties of bedquilts.

  • PDF

Natural Dyeing of Silk Fabrics with Rumex crispus L. Root (소루쟁이뿌리를 이용한 견직물의 천연염색)

  • Han, Mi-Ran;Lee, Jeong-Sook
    • Fashion & Textile Research Journal
    • /
    • v.11 no.1
    • /
    • pp.166-173
    • /
    • 2009
  • The natural dyeing of silk fabrics with Rumex crispus L. root extract was investigated. The dyeability of Rumex crispus L. root extract was evaluated with condition of concentration, temperature, time, repeat-numbers, pH, mordants variables, methods of mordanting, color fastness and antibacterial activity, etc. The wavelength of maximum absorption of the Rumex crispus L. distilled water extract appears at 274 nm and 336 nm, methanol extract was 274 nm and 356 nm. Optical dyeing temperature of silk fabrics was $70^{\circ}C$. The K/S values of the dyed fabrics were increased with increasing dyeing time. Surface colors of dyed fabrics were various by the used mordants; RP-YR-Y range. The color fastness was improved by adding mordants were added except Sn. Dyed silk fabrics with mordants showed antibacterial activity.

Dyeabilities of Lac Extract onto the Silk and Wool Fabrics (동물성 섬유에 대한 Lac 추출물의 염색성)

  • 박문영;김호정;이문철
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.8
    • /
    • pp.1248-1253
    • /
    • 2002
  • Coocus laccae(Laccifer lacca Kerr), usually known as Lac, is a kind of cocoon which is parasitic on the tree around India and China. It contains the laconic acid of red colored dyes and has been used for cosmetic or natural dyeing prior to the introduction of New World cochineal. Nevertheless, the characterization of lac has not been studied, very little informed. The purpose of this study is to examine the effects of dyeing conditions fur Lac extract, such as pH of dye bath, concentration of Lac exact dyeing temperature and time, to find out the optimum conditions. The results were as follow. 1. The highest K/S values of the silk and wool was shown at PH 3 and PH 4. 2. K/S values of the silk came to nearly the adsorption equilibrium state at 40$^{\circ}C$ and the curve of wool showed a dramatic increase with the increase of temperature. 3. Dyed silk and wool fabrics showed good light fastness without using mordants.

Ventilation and Comfort Sensation by Slit Positions of Running Wear Jackets (러닝웨어 재킷의 슬릿 위치가 통기성과 착용감에 미치는 영향)

  • Lim, Ji-Hye;Roh, Eui-Kyung;Yoo, Hwa-Sook;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.11
    • /
    • pp.1794-1805
    • /
    • 2009
  • This study investigates the influence of slit positions on the microclimate temperature/humidity of garments. To design the slits, a market survey was performed to indicate the method to apply the slits, in addition to a literature survey about muscles and body surface variation through body movements. Based on the survey, three positions of slits were selected, shoulder slit, lowback slit, and midback slit, a slit width of 1cm and length to 30cm was used. The results showed that microclimate temperatures/humidity on the back according to the slit positions were in the order of, lowback, midback, and the shoulder. The lowback slit showed the highest effect on the temperature/humidity of a front trunk. Lowback slits affected on localized areas of the glutaeus maximus, erector spinae, and latissimus dorsi. Midback slits affected the back muscle and deltoid. Shoulder slits showed a more significant effect on the localized area of the deltoid versus other localized areas. In the subjective sensations, the lowback slit was cooler, dryer, and more comfortable than the other slits. For the subjective sensations by fabric characteristics, the slit positions correlated at |r|${\geq}.8$ and were significant at p<.001 The results show that the lowback slit has a superior air exchange effect and thermoregulation qualities.

End Use Tactile Property of the Split-type Nylon/PET Microfiber Fabrics (마찰과 세탁에 의한 극세섬유 직물의 표면과 촉감변화에 관한 연구)

  • 오경화;윤재희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.539-545
    • /
    • 2004
  • In this study, the effect of washing, bleaching, and abrasion on tactile and the water absorption properties of the split-type Nylon/Polyester (N/P) microfiber pile-knit was investigated under various enduse conditions. We examined the water absorption and surface properties of PET microfiber which will be very useful in the future. We also studied the variations of their performance during usage caused by friction and repeated washing, regard to all kinds of physical, chemical changes which will appear while using those textiles. Progress in further splitting of PET microfiber fabric is observed with increases in the number of washing and bleaching cycles, and treatment temperature. Initial water absorption (%) was increased with progress in splitting, which provided efficient capillary channel. Surface properties were varied with additional splitting by washing and abrasion. Formation of pilling and splitting by abrasion increase surface roughness, diminishing tactile property, and reduced water absorption property. The current results from this study is expected to provide the appropriate washing management guide to consumers, and to inform end-use performance of product to a producer for improving product quality.

Analysis of the Effects of Vests with Fan in Summer Environments (여름철 환경에서 팬이 있는 조끼의 인체 착용 효과)

  • Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.6
    • /
    • pp.856-865
    • /
    • 2019
  • This study analyzed the effect of wearing a vest with an attached electric fan. Korean men in their 20s were given test "fan vests" equipped with fans on the chest, stomach, upper back, or lower back to wear. Participants wore them in a climate chamber set to replicate a summer environment (30±3℃, 75±1%RH, 0.2 m/sec). Subjective sensations and surface temperatures were measured. The attached fan on the front of the vest lowered the temperature of the vest and the skin surface where the fan was positioned, regardless of whether the wearer engaged in exercise. However, a fan attached to the lower back of the vest was effective in lowering the lower back of the vest as well as the upper back, back of the arm, and back of the neck. In addition, subjective evaluations indicated that a vest with fans attached to the stomach and lower back provided a cool sensation. However, it was confirmed that the design of an auxiliary tool capable of dispersing the weight is necessary since the weight of the fans can interfere with the comfort of wearing the vest.