• 제목/요약/키워드: Clothing Insulation

검색결과 124건 처리시간 0.027초

'발열내복'이라 광고되는 시판 기능성 보온내복의 써멀 마네킹과 인체 착용 실험을 통한 체온조절 성능 평가 (Evaluation of Thermoregulatory Properties of Thermal Underwear Named as 'Heating Underwear' using Thermal Manikin and Human Performance Test)

  • 이효현;이영란;김지은;김시연;이주영
    • 한국의류산업학회지
    • /
    • 제17권4호
    • /
    • pp.657-665
    • /
    • 2015
  • This study evaluated the thermoregulatory properties of functional thermal underwear ('heating underwear') in markets using a thermal manikin and human wear trials. One ordinary thermal underwear (ORD) and two functional thermal underwear (HEAT1 and HEAT2; manufactured goods, HEAT1: moisture absorbing heat release mechanism, HEAT2: heat storage, release mechanism) were chosen. Thermo-physiological and subjective responses were evaluated at an air temperature of $5.0{\pm}0.5^{\circ}C$ and air humidity of $30{\pm}5%RH$ with five male subjects ($21.6{\pm}1.3yr$ in age, $178.0{\pm}5.9cm$ in height, $68.2{\pm}5.9kg$ in body mass). Experimental conditions consisted of four ensembles that included winter clothes (Control: no underwear, ORD, HEAT1, HEAT2). Water-vapor resistance was greater in fabric of HEAT1 than others. The results were: 1) Total thermal insulation (IT) using a thermal manikin were not greater for HEAT1 (0.860clo) and HEAT 2 (0.873clo) than for ORD (0.886clo). 2) There were no significant differences in rectal temperature, mean skin temperature, heart rate and total body mass loss between the four conditions. Microclimate clothing temperature on the back was greater for ORD than for HEAT1 and HEAT2. Subjects felt more comfortable with HEAT1 than for others at rest. HEAT2 was higher in microclimate humidity when compared to other conditions. The results suggest that thermoregulatory properties of 'heating underwear' in market did not differ from those of ordinary thermal underwear in terms of total thermal insulation and thermoregulatory responses in a cold environment.

생활폐기물 소각장 작업복의 중금속 분석 (Analysis of Heavy Metal Concentration on Working Clothes for Waste Incinerating Workers)

  • 박순자
    • 한국지역사회생활과학회지
    • /
    • 제18권1호
    • /
    • pp.39-53
    • /
    • 2007
  • The purpose of this study was to determine the characteristics of an experimental protective clothing material with regard to comfort and isolation from the hazardous heavy metals produced in municipal waste incineration. An analysis was conducted on the total concentrations of heavy metals in some parts such as surface, middle layer, and interior for the treated fabric, and the untreated one, and working clothes. We conclude that the processed fabric with charcoal for working clothes showed the least exposure to heavy metals of the three. Working clothes worn by workers during waste incineration were much more contaminated than the untreated and treated materials. The material of working clothes could be chosen according to the function with regard to its original chemical characteristics, which are the proper results of the dyeing process. The processed fabric material has high degrees of moisture regain, thermal insulation, water vapor penetration, and antibacterial function; consequently, it is much more comfortable to wear. The fabric material proposed in this research contributed much more to blocking heavy metal concentrations (such as Cd, Pb, Cu, Cr, Zn, Mn) than did the fabric of working clothes at present. Consequently, we strongly suggest that the material of working clothes be upgraded by adopting the above-mentioned charcoal-processed fabric. Materials of working clothes must be improved to increase comfort and prevent harmful gas, flying dust, and heavy metals from permeating the fabrics.

  • PDF

북한의 1월.8월 인체보온지수 분포의 특성 (The Characteristics of January and August Clo-Unit Distribution in North Korea)

  • 강철성
    • 한국지역지리학회지
    • /
    • 제10권1호
    • /
    • pp.151-157
    • /
    • 2004
  • 1월의 clo 값은 대체로 삼지연 지역이 가장 높게 나타나고, 장전 일대의 동해안 지역이 가장 낮게 나타난다. 또한 해안 지역보다 내륙 지역이, 동해안보다 서해안이 clo 값이 높게 나타난다. 이는 지형적 영향과 기온과 풍속의 지역적 차이에 기인한다. 8월에도 삼지연, 해산 일대, 개마고원 등이 높게 나타나는데, 이는 지형적 영향으로 기온 저하와 풍속의 증가로 나타나는 현상이다. 특히 8월에는 삼지연을 중심으로 북동-남서 내륙지역으로 등치선이 만곡하고, 이 축을 중심으로 한 이외의 지역이 비교적 낮은 분포를 보인다. 이러한 원인으로는 위도, 지형 및 장마 이후의 고온 다습한 북태평양 기단의 영향과 강한 일사에 의한 지면 복사열의 방출에 있다고 사료된다.

  • PDF

여닫이와 미닫이를 복합한 고기밀성 단열창호 성능평가 (The Evaluation on Thermal Window High-Tight Composition of Sliding Door and Open Door)

  • 최동혁;최경석;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.724-729
    • /
    • 2009
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. To reduce the loss of the energy which leads, to an air conditioning energy and an expense increase problem the color which the interior furniture and the clothing due to the augmentation and the corpse ultraviolet rays of the unpleasant feeling which is caused by with the transient one solar energy influx which leads the window will burn, it joins in the window and it confronts and the novel solution is demanded.

  • PDF

몰드 브래지어 컵의 제작을 위한 3D 스페이서 패브릭과 폴리우레탄(PU) 폼 조합에 따른 열·수분 전달 특성 비교 (Comparisons of Thermal-moisture Properties in Combination of 3D spacer and Polyurethane(PU) Foam for Mold Brassiere Cups)

  • 이현영;박희주
    • 한국생활과학회지
    • /
    • 제24권2호
    • /
    • pp.285-295
    • /
    • 2015
  • To identify optimized thermal properties of mold brassiere cup for improved thermal comfort during summer, we compared the thermal resistance and the water vapor permeability of Polyurethane (PU) foam, 3D spacer fabric and the two combined materials of the PU foam and the 3D spacer fabric. Four experimental mold brassieres were made of the materials for wearing test. Six women in their twenties evaluated the wearing sensation in the hot and humid environment. The changes in microclimate temperature and humidity while wearing test brassiere cups were measured. Results indicate that thermal resistance increased as more PU foam were combined, while the water vapor permeability was higher as the content of the 3D spacer fabric increased at thickness of 18mm and over. However, in the wear test, the PU foam brassiere was the most preferred in all ambient conditions due to its soft, flexible and smooth texture, despite its high thermal resistance and low water vapor permeability. This indicates that the textures of mold foams are more dominant properties than thermal properties for mold foams in determining the wear comfort of mold brassieres.

남녀 중학생의 겨울철 교실 내 한서감과 기후적응성 (Thermal Sensation in Winter Classroom and Cold Climate Adaptability of Junior High School Students)

  • 조아름;심현섭
    • 한국의류산업학회지
    • /
    • 제20권6호
    • /
    • pp.744-751
    • /
    • 2018
  • This study aimed to provide the information on the thermal sensation and the amount of clothing worn of junior high school students in winter classroom the relation with their climate adaptability. Total usable questionnaires were obtained from 467 male and female students. The questionnaire included general characteristics, physical characteristics, self awareness of body shape, climate adaptability and subjective thermal sensation in winter classroom. The data were analyzed using SPSS Statistics 18.0 for frequency analysis, factor analysis, chi-square analysis, t-test and correlation analysis. The results were as follows. The average body type based on BMI was normal($20.1kg/m^2$ ). Females perceived their body type as thinner than males. They wore more (8.67 garment items compared to 8.14 for males). Only about 25% of students voted the thermal sensation to neutral(47% cool~very cold, 28% warm~very hot). Females were more sensitive to the cold, perceived less healthy, and wore more garments in the cold. Students felt colder in winter classroom when their cold adaptability was lower and they actively adjusted thermal insulation against the cold. It is recommended to suggest the guidelines for the proper indoor temperature and for the wear behavior in classroom in the perspectives of increasing the learning efficiency and improving the students' climate adaptability.

서열환경하에서 체지방률에 따른 오전과 오후의 체온조절반응 (Thermoregulatory Responses of AM & PM with Body Fat Rate at a Hot Environment)

  • 김성숙;이정숙;김희은
    • 한국의류산업학회지
    • /
    • 제7권3호
    • /
    • pp.315-320
    • /
    • 2005
  • With regard to the fact that temperature of human body remains almost constant at $37^{\circ}C$, changes by circadian variation, this study intended to investigate the effect of circadian rhythm on physiological responses of human body according to body fat rate. Fifteen healthy adult women were recruited for this study and were measured body fat as a method of bio impedance. We organized subjects into three groups ; low body fat group(group L-less than 20% of body fat), medium body fat group(group M-20%~30% of body fat) and high body fat group(group H-more than 30% of body fat). The experiment was carried out in a climate chamber of $32^{\circ}C$, 60% RH with the repeat of 'Exercise' and 'Rest' period. Subjects participated in two experiments, one is morning experiment(called 'AM'), the other is afternoon experiment (called 'PM'). The results of this study are as follows ; As to the variation of rectal temperature, group L and M had a significant difference in the time of the day between AM and PM, but group H had almost the same rectal temperature in the two kinds of experimental time. The reason why group H had a smaller difference in the circadian rhythm of rectal temperature in this study is estimated at the Budd et al.(1991)'s results that body fat had effects on reduction in thermogenesis, radiation, mean skin temperature, and increase in insulation of the tissues. Group M had the highest mean skin temperature in the 'PM'. All the 3 groups didn't have stable values in 'AM'. But it showed more stable in 'PM' than 'AM'. Sweat rate was the highest in group H in both 'AM' and 'PM'. Group M had larger sweat rate in 'PM' than 'AM'. but in group L and H, sweat rate was almost the same in two kinds of time of the day. This result suggests that who have more or less body fat have larger difference in sweat rate between morning and afternoon than who have normal body fat.

방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구 (A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season)

  • 여용헌;홍성돈;이민희;김경필;정일한
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.492-500
    • /
    • 2018
  • 동절기 방한복의 성능 평가는 주로 열 저항으로 이루어지고 있다. 그러나, 이를 측정하기 위한 KS가 개정되면서, 동일한 표본의 시험결과가 개정 결과에 비하여 감소하는 결과를 초래하였다. 또한, 공인 시험기관마다 변경된 시험 절차 대한 해석의 차이가 발생하여 시험 기관 간에 결과 편차도 크게 발생하고 있으며, 이로 인해 군수품의 품질보증에 상당한 애로가 되고 있다. 따라서 본 연구에서는 개정된 시험방법에 따른 보온율 감소 현상의 원인을 분석함으로써, 개정 전과 후의 결과 편차를 최소화하고자 한다. 이를 위해 규격의 개정 전과 개정 후의 시험 조건의 차이와 이로 인해 발생 가능한 결과를 검토한다. 또한, 규격의 임의해석에 따른 시험 기관간 결과 편차 발생의 원인을 분석함으로써 시험 기관간의 결과 편차를 최소화 하고자 한다. 이를 바탕으로 개정 전 시험 방법과 편차가 가장 적은 조건을 확인하여 보온율 감소 현상을 예방하기 위한 표준을 제시하고자 한다.

하계 항만열환경정보 제공을 위한 열환경 평가 및 예보시스템 구축 (Heat Stress Assessment and the Establishment of a Forecast System to Provide Thermophysiological Indices for Harbor Workers in Summer)

  • 황미경;윤진아;김현수;김영준;임연주;이영미;김영남;윤의경;김유근
    • 한국환경보건학회지
    • /
    • 제42권2호
    • /
    • pp.92-101
    • /
    • 2016
  • Objectives: Outdoor workers are exposed to thermally stressful work environments. In this study, heat stress indices for harbor workers in summer were calculated to evaluate thermal comfort based on a human heat balance model. These indices are Physiological Subjective Temperature (PST), Dehydration Risk (DhR), and Overheating Risk (OhR) according to respective stage of cargo work in a harbor. In addition, we constructed a forecast system to provide heat stress information. Methods: Thermophysiological indices in this study were calculated using the MENEX model (i.e. the human heat balance model), which used as inputs the meteorological parameters, clothing insulation, and metabolic rate for each stage of cargo work in the harbor of Masan over the course of seven days, including a four-day heat wave. The forecast heat stress information constructed for Masan harbor was based on meteorological data supported by the Dong-Nae Forecast from the KMA (Korea Metrological Administration) and other input parameters. Results: According to higher metabolic rate, thermophysiological indices showed a critical level. In particular, PST was evaluated as reaching the 'Very hot' or 'Hot' level during all seven days, despite the heat occurring over only four. It is important in a regard to consider the work environment conditions (i.e. labor intensity and clothing in harbor). On a webpage, the forecast thermophysiological indices show as infographics to be easily understand. This webpage is comprised of indices for both current conditions and the forecast, with brief guidance. Conclusion: Thermophysiological indices show the risk level to health during a heat wave period. Heat stress information could help to protect the health of harbor workers. Further, this study could extend the applicability of these indices to a variety of outdoor workers in consideration of work environments.

공조제어 적용을 위한 재실자 온열반응 데이터의 유효성 분석에 관한 연구 (An application to HVAC control system based on occupants' thermal response in office buildings)

  • 한혜심;김종훈;정학근;장철용
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.111-117
    • /
    • 2014
  • In South Korea, the government has recently enforced regulations associated with buildings. Temperature restriction in indoor environment is one of the common ways of energy reduction in order not to dissipate heating and cooling energy; however the people who are in restricted temperature feels uncomfortable. Furthermore, occupants cannot feel the same thermal sensation even they are in the same place. For the reason, occupants should express their thermal sensation and HVAC system should be able to apply their demand. It is proved by an adaptive principle. The adaptive model means that people react in ways which tend to restore their comfort, when change occurs such as to produce discomfort. In order to design HVAC control strategies based on adaptive model, we designated an existing office building as a reference building to gather data from actual field. Furthermore, we gathered occupants' thermal sensation and clothing insulation in real-time. We filtered the data with Kalman's filter method. The data was reasonable when there is an alarm messages for asking questionnaire. The response ratio were different in occupants' thermal condition. In conclusion, the filtered occupants' thermal sensation can be used as a real time HVAC control and input value of HVAC control.