• Title/Summary/Keyword: Closed-Structure

Search Result 983, Processing Time 0.03 seconds

Dependency of the emission efficiency on doping profile of the red phosphorescent organic light-emitting diodes

  • Park, Won-Hyeok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.224-224
    • /
    • 2016
  • Many researchers have been tried to improve the performance of the phosphorescent organic light-emitting diode(PHOLED) by controlling of the dopant profile in the emission layer. In this work, as shown in Fig. 1 insert, a typical red PHOLED device which has the structure of ITO/NPB(50nm)/CBP(30nm)/TPBi(10nm)/Alq3(20nm)/LiF(0.8nm)/Al(100nm) is fabricated with a 5nm thick doping section in the emission layer. The doping section is formed by co-deposition of CBP and Ir(btp)2acac with a doping concentration of 8%, and it's location(x) is changed from HTL/EML interface to EML/HBL in 5nm steps. The current efficiency versus current density of the devices are shown in Fig. 1. By changing the location of doping section, as shown in Fig. 1 and 2, at x=5nm, the efficiency shows the maximum of 3.1 cd/A at 0.5 mA/cm2 and it is slightly decreased when the section is closed to HTL and slightly increased when the section is closed to HBL. If the doping section is closed to HTL(NPB) the excitons can be quenched easily to NPB's triplet state energy level(2.5eV) which is relatively lower than that of CBP(2.6eV). Because there is a hole accumulation at EML/HBL interface the efficiency can be increased slightly when the section is closed to HBL. Even the thickness of the doping section is only 5nm,. the maximum efficiency of 3.1 cd/A with x=5 is closed to that of the homogeneously doped device, 3.3 cd/A, because the diffusion length of the excitons is relatively long. As a result, we confirm that the current efficiency of the PHOLED can be improved by the doping profile optimization such as partially, not homogeneously, doped EML structure.

  • PDF

A Visual-perceptive Study on Closed and Open Forms of Ethnic Looks since the 1980s (1990년대 이후 에스닉 룩의 폐쇄형과 개방형의 시지각적 연구)

  • 서봉하
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.4
    • /
    • pp.145-156
    • /
    • 2004
  • This study is regarding closed and open forms, which have relatively high recognition among visual perception phenomena in costumes. In particular, this study reviewed closeness and openness of ethnic look, which is a representative open costume. Closed form can be summarized as simple and clear silhouette, conspicuous differentiation from the background, simple construction of the costume and colors with low brightness and clearness. It Is modern, functional, rational and modest. On the other hand, open form can be summarized as complicated and inconspicuous edge line, complicated inner shape and colors with high brightness, high clearness and vividness. It includes concepts of pleasure, entertainment, joy, eroticism, rebel and resistance. Modern costumes have been simplified for a long time and they have functional and closed characteristics in their shape, structure and form. On the other hand, modern open form costumes are usually found in sub-cultural styles such as punk, hippie, kitsch and vintage, and some ethnic looks. Following is a summary of the characteristics of open form shown in the ethnic look. 1. The shape, structure of costumes, hair accessories, lace, ruffle and ornaments are complicated and irregular. 2. The silhouette is inconspicuous because of ambiguity between backgrounds and ABC (Apparel-Body-Construct) or the use of see-through materials. 3. It makes complicated visual shapes because it does not have a single type but is composed of various clothing items together. 4. It gives complex feelings by matching various colors or more than two different fabrics. 5. It looks like the open type because of the complex patterns shown in the costumes.

Vibration Control of Hvbrid Smart Structure Using PZT Patches and ER Fluids (PZT와 ER유체를 적용한 복합지능구조물의 진동제어)

  • Yun, Shin-Il;Park, Keun-Hyo;Han, Sang-Bo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.734-739
    • /
    • 2003
  • Many types of smart materials and control laws are available to actively adjust the structure from various external disturbances. Usually, a certain type of control laws to activate a specific smart material is well established, but the effectiveness of the control scheme is limited by the choice of the smart materials and the responses of the structure. ER fluid is adequate to provide relatively large control force, on the other hand, the PZT patches are suitable to provide small but arbitrary control forces at any point along the structure. It was found that active vibration control mechanism using ER fluid failed to suppress the excitation off the resonant frequency with changed structural characteristics along the frequency response function of the closed loop of the control system. To compensate this additional peak of the closed loop system, PPF control using PZT as an actuator is added to construct a hybrid controller.

  • PDF

Effects of Three-Body Interactions on the Stability of Small Carbon Clusters (3체 인력이 탄소 cluster들의 안정도에 미치는 효과)

  • Lee, Jong-Mu
    • Korean Journal of Materials Research
    • /
    • v.1 no.2
    • /
    • pp.86-92
    • /
    • 1991
  • A potential energy function comprising a two-body potential term which is modified form Morse potential and a three-body potential term which is modified from Axilrod-Teller potential has been developed for small carbon clusters. The structural changes of small carbon clusters $C_2-C_6$ are qualitatively investigated by employing this potential energy function representing the energies of the small carbon cluster isotopes as a function of the three body intensity factor. It is found that the structure of the small carbon cluster changes from open structure to closed one, from complicated structure to simple one, and from three-dimensional structure to two-or-one dimensional one as the degree of the three-body interaction increases.

  • PDF

Design of Friction Dampers installed at a Multi-Story Building under Seismic Load (지진하중을 받는 다층 건물에 설치된 마찰감쇠기 설계)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.457-462
    • /
    • 2011
  • In this study, a simplified design procedure for friction dampers of a multi-story structure in order to reduce seismic response is proposed. To get insight for control effect of the structure with friction dampers is difficult, because of a nonlinear characteristic by a friction damper. Since a control force of a friction damper is influenced by coupling velocity between floors, adjoining modes are coupled. Thus structural response are derived by assuming steady-state response in resonance. As it is impossible that an exact solution is obtained for seismic load, first, a closed form solution can be achieved under harmonic vibration. Second, to convert a three-story building into a single-degree-of-freedom(SDOF) structure, modal analysis is performed. Third, an equivalent damping ratio is derived with utilizing closed form solution. And response reducing factor is proposed by it. Finally, friction force of a damper is designed for using response reducing factor, and then designed dampers are verified for seven seismic data. The nonlinear analysis results confirm the validity of the proposed procedure.

A Dual Band Directional Coupler with Feedback Compensation Using Diplexer Structure (Diplexer 구조를 이용한 Dual Band 방향성 커플러)

  • Kim Ki-Joong;Park Ja-Young;Jeong Young-Hak;Bae Hyo-Gun;Kim Nam-Heung;Kim Hak-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.783-789
    • /
    • 2005
  • In this paper, a novel design and implementation of a dual-band directional coupler based on RF IPD(Integrated Passive Device)-on-glass technology is proposed, which can be adopted in GSM/GPRS cellular phones for closed loop power control at the output of the power amplifier. The proposed coupler has a compensation capacitor to improve the directivity, and was designed using a new diplexing structure to minimize the cross-band isolation.

A Study to Propose Closed-form Approximations of Seismic Hazard (지진 재해도의 닫힌 근사식 제안에 관한 연구)

  • Kwag, Shinyoung;Hahm, Daegi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.245-251
    • /
    • 2018
  • In this paper, we address some issues in existing seismic hazard closed-form equations and present a novel seismic hazard equation form to overcome these issues. The presented equation form is based on higher-order polynomials, which can well describe the seismic hazard information with relatively high non-linearity. The accuracy of the proposed form is illustrated not only in the seismic hazard data itself but also in estimating the annual probability of failure (APF) of the structural systems. For this purpose, the information on seismic hazard is used in representative areas of the United States (West : Los Angeles, Central : Memphis and Kansas, East : Charleston). Examples regarding the APF estimation are the analyses of existing platform structure and nuclear power plant problems. As a result of the numerical example analyses, it is confirmed that the higher-order-polynomial-based hazard form presented in this paper could predict the APF values of the two example structure systems as well as the given seismic hazard data relatively accurately compared with the existing closed-form hazard equations. Therefore, in the future, it is expected that we can derive a new improved APF function by combining the proposed hazard formula with the existing fragility equation.

Optimal Design of Stator of Permanent Magnet Motors Having Closed Slot For The Cogging Torque Reduction (폐슬롯 형상을 가진 영구 자석형 동기 전동기의 코깅 토크 저감을 위한 고정자 치수 최적화)

  • Chun, J.S.;Hong, S.K.;Yoon, J.S.;Jung, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.59-61
    • /
    • 1995
  • This paper presents the cogging torque analysis of the permanent magnet type AC servo motor which have the closed slot structure. Generally, existence of the slot opening causes the cogging torque. But the cogging torque exists in this type motor(having closed slot structure) because the bridge part is saturated by the rotor flux. In this paper, the finite element analysis is used to calculate the cogging torque and the rated torque. As the size of the bridge part-the thickness and the width-changes, the cogging torque and the rated torque are obtained repeatedly like as upper procedures. Finally, the trends of the cogging torque and the rated torque versus the size of the bridge part are obtained from this analysis procedures. By this approach, the optimal geometry of the bridge part can be found which minimize the cogging torque satisfying the required value of the rated torque.

  • PDF