• 제목/요약/키워드: Closed school

Search Result 1,614, Processing Time 0.031 seconds

CO concentration distribution in a tunnel model closed at left end side using CFD

  • Peng, Lu;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.282-290
    • /
    • 2013
  • A primary air pollutant as an indicator of air quality released from incomplete combustion is Carbon monoxide. A study of the distributions of CO concentration with no heat source in a tunnel model closed at left end side is simulated with a commercial CFD code. The tunnel model is used to investigate the CO concentration distributions at three Reynolds numbers of 990, 1970, and 3290. which are computed by the inlet velocities of 0.3, 0.6 and 1.0 m/s. The CFD predictive approaches can be useful for a better design to analyze the distributions of CO concentrations. In the case of the tunnel model closed at left end side alone, the concentration changes of x/H=-5 and -2.5 have the similar laminar characteristics like the case of the tunnel model closed at both end sides expecially at low values of Reynolds number. Irregular average CO concentration variations at Re=1790 are considered that the transition from laminar to turbulent flow occurs even in three different tunnel models.

Thermal Reliability Analysis of BLDC Motor in a High Speed Axial Fan by the Accelerated Life Test (가속수명시험에 의한 고속팬용 밀폐구조형 BLDC 모터의 열신뢰성 분석)

  • Lee Tae-Gu;Moon Jong-Sun;Yoo Hoseon;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1169-1176
    • /
    • 2005
  • In this paper, thermal reliability of a closed type BLDC (Brushless DC) motor for high speed axial fan was analyzed by the accelerated life test. The closed type BLDC (Model No. MB1-8855-J01) motor was controlled by PCB module, which was composed of various electrical components. The failure of the closed type BLDC motor happened in PCB module due to high temperature. Failure mechanism of the closed type BLDC motor appears to be electrolyte dry out of capacitor. The accelerate life test was performed in temperature stress of $85^{\circ}C\;and\;105^{\circ}C$, respectively The failure data from the accelerated life test were analyzed and the life in each stress level was estimated with 960h and 261 h. At last, both life expression according to operating temperature of PCB module and life of the closed type BLBC motor in normal condition $(50^{\circ}C)$ were suggested.

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Comparisons of Accuracy of Knee Joint Motion During Closed verse Open Kinetic Chain Tasks in Subjects with Flexible Flatfeet

  • Kim, Ju Sang;Kwon, Younghyun;Lee, Mi Young
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • Purpose: This study examined the effects of flexible flatfeet on the accuracy of knee joint motions in closed and open kinetic chain tasks. Methods: Twenty-four healthy participants were recruited for this study. The subjects were divided into two groups using a navicular drop (ND) test: flexible flatfoot group (n=12, male: 6, aged $22.00{\pm}2.22years$) and age-matched control group (n=12, males: 6, aged $22.17{\pm}1.53years$). The accuracy of knee motion was measured quantitatively by tracing through the flexion and extension motion of the knee joints in the closed kinetic chain and the open kinetic chain. Results: There was a significant difference in the accuracy index between the groups in closed kinetic chain task, but there was no significant difference in the open kinetic chain task. In addition, there was a significant difference in the accuracy index between the closed kinetic chain and the open kinetic chain task in the flexible flatfoot group. In addition, a significant negative correlation was observed between the ND and accuracy index in the closed kinematic chain task, but there was no significant relationship between the ND and accuracy index in the open kinematic chain task. Conclusion: Flexible flatfeet can affect the accuracy of the adjacent joints, such as the knee joint in the closed kinematic chain.

Fabrication of complete denture using Centric tray and closed mouth technique for edentulous patient (과도한 치조제 흡수를 보이는 무치악 환자에서 Centric tray와 폐구법 인상을 이용한 총의치 수복 증례)

  • Jung, Sua;Ma, Boyoung;Yang, Hongso;Park, Sangwon;Lim, Hyun-Pil;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.120-125
    • /
    • 2018
  • Conventional denture impression techniques have limitations for edentulous patients with severe alveolar bone resorption and can cause problems from excessive border extension. Especially when a patient has movable tissue it is difficult to make accurate impression, thus might interrupt stable seating of complete denture. Fabrication of complete denture using closed mouth technique for edentulous patient with severe ridge resorption is thought to provide better stability and retention. In this case, an 86-year-old patient had both edentulous jaws with epulis fissuratum on maxillary anterior ridge and severe mandibular ridge resorption. Thus, tentative vertical dimension was determined by using Centric trayand individual tray attached with gothic arch tracer was fabricated. Complete denture was fabricated using closed mouth technique and the patient was satisfied with better stability and retention of the complete denture.

A Study on the Establishment of Welfare Facilities for the Aged Using the Facilities Characteristics of Closed Schools - Focused on the Northern Area of Gyeonggi-Do - (폐교의 시설 특성을 활용한 노인복지시설 구축에 관한 연구 - 경기 북부지역을 중심으로 -)

  • Kim, Hak Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.2
    • /
    • pp.17-24
    • /
    • 2021
  • Changes in the population structure caused by a decrease in the birthrate and an extension of life expectancy cause problems in utilization inefficiencies of closed schools and shortage welfare facilities for the aged. The closed schools have location characteristics that are close to the existing residence and facilities such as land and school buildings, so it is expected that the schools will be used as welfare facilities for the aged in the community. The purpose of this study is to compare and analyze the facility characteristics of closed schools in northern Gyeonggi-Do and present the types of aged welfare facilities that can be built, providing basic data for developing customized aged welfare facilities. The results of this study are summarized as follows: 1) The proportion of aged people in northern Gyeonggi-Do is higher than in southern Gyeonggi-Do, but welfare facilities for the aged are insufficient, so it is necessary to expand welfare facilities for the aged in northern Gyeonggi-Do. 2) Urban areas such as Paju and Goyang City have a lot of residential proximity, Dongducheon and Yangju have a lot of residential proximity, while schools located in urban and rural areas such as Yeoncheon have a lot of residential proximity. 3) Closed schools in urban areas such as Goyang City and Paju City are desirable to use them as residential facilities for senior citizens, day and night protection and short-term protection facilities, while closed schools in Namyangju City, Pocheon City, and Gapyeong County are desirable to use them as senior citizen centers and medical welfare facilities.

Lateral facial cleft : Cases Report (횡안열 환자의 치험례)

  • Choi Ju-Suck;Cho Sang-Ki;Beak Jin-A;Ko Seung-O;Shin Hyo-Keun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.6 no.1
    • /
    • pp.53-58
    • /
    • 2003
  • Lateral facial cleft is a rare congenital craniofacial anomaly. Their incidence is about 1 in 60,000 births and early treatment with closure in layers is important. Surgical treatment must reconstruct an anatomic and functional situation which give a good esthetic result. This study reports two cases of male at 31 months and 9 months suffered from esthetic problems due to lateral displacement of the oral commisure on the right side. Surgical treatment; the mucosa is closed in with a Z-plasty to avoid intraoral band contracture, the orbicularis oris muscle is closed after interfiber reorientation, and the skin is closed with multiple Z-plasty. So we report two cases of unilateral lateral facial cleft and review of etiopathogenesis in children with lateral facial cleft.

  • PDF

Characteristics of Closed Circuit Cooling Tower with Multi Path on Cooling Water Inlet Conditions (냉각수 변화에 따른 멀티패스 밀폐식 냉각탑의 성능)

  • Shim, Gyu-Jin;Baek, Seung-Moon;Moon, Choon-Geun;Yoon, Jung-In;Kim, Eun-Pil;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.597-602
    • /
    • 2008
  • The experiment of performance about closed-wet cooling tower(CWCT) was conducted in this study. The test section has the cooling water that flows from top part of a heat exchanger that has an entrance of cooling water with one and multi path. The heat exchanger consists of 15.88mm tubes with ten rows and ten columns and staggered arrangement. In this experiment, heat and mass transfer coefficients and range are calculated with variations of cooling water and path. The results indicated that operating CWCT using two path have the high values of heat and mass transfer coefficients and range than one path.

  • PDF

TREATMENT OF THE OSTEOMYELITIS OCCURRED BY THE FRACTURE OF THE MANDIBLE (악골 골절후 발생된 골수염의 처치의 치험례)

  • Kim, Sung-Kug;Sohn, Dong-Seok;Go, Mal-Sik;Seo, Jung-Sik;Lee, Chul-Hee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.3
    • /
    • pp.277-282
    • /
    • 1995
  • With the use of antibiotics and improved dental care, osteomyelitis of the jaw is less common these days, But sometimes the management of osteomyelitis is more difficult because of appearance of resistant organisms to antibiotics. Treatment of the steomyelitis are incision and drainage, closed catheter irrigations, sequestrectomy, saucerization, hyperbaric ocygen therapy, and resection with or without bone graft. We experienced advanced osteomyelitis due to delayed treatment of left mandibular angle fracture. He have medical history of pschysoprenia. We decided to treat the patient with open reduction and closed cather irrigation. We achived reconsolidation of mandibular fracture accompanied by osteomyelitis by complete removal of inflammatory tissues, rigid fixation with miniplate and closed catheter irrigation.

  • PDF

Modeling and Design of Zero-Voltage-Switching Controller for Wireless Power Transfer Systems Based on Closed-Loop Dominant Pole

  • Chen, Cheng;Zhou, Hong;Deng, Qijun;Hu, Wenshan;Yu, Yanjuan;Lu, Xiaoqing;Lai, Jingang
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1235-1247
    • /
    • 2019
  • Zero-Voltage-Switching (ZVS) operation for a Wireless Power Transfer (WPT) system can be achieved by designing a ZVS controller. However, the performance of the controller in some industrial applications needs to be designed tightly. This paper introduces a ZVS controller design method for WPT systems. The parameters of the controller are designed according to the desired performance based on the closed loop dominant pole placement method. To describe the dynamic characteristics of the system ZVS angle, a nonlinear dynamic model is deduced and linearized using the small signal linearization method. By analyzing the zero-pole distribution, a low-order equivalent model that facilitates the controller design is obtained. The parameters of the controller are designed by calculating the time constant of the closed-loop dominant poles. A prototype of a WPT system with the designed controller and a five-stage multistage series variable capacitor (MSVC) is built and tested to verify the performance of the controller. The recorded response curves and waveforms show that the designed controller can maintain the ZVS angle at the reference angle with satisfactory control performance.