• 제목/요약/키워드: Clinical profile

검색결과 707건 처리시간 0.028초

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • 대한청각학회지
    • /
    • 제25권2호
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

The Effect of an Empowerment Program on the Health-promoting Behaviors of Iranian Women Workers: A Randomized Controlled Trial

  • Noori, Fatemeh;Behboodimoghadam, Zahra;Haghani, Shima;Pashaeypoor, Shahzad
    • Journal of Preventive Medicine and Public Health
    • /
    • 제54권4호
    • /
    • pp.275-283
    • /
    • 2021
  • Objectives: The workplace is an ideal place for encouraging health-promoting behaviors. Therefore, the aim of the present study was to determine the effect of an empowerment program on the health-promoting behaviors of women workers. Methods: This randomized clinical trial was conducted with 80 women workers employed at a food packaging facility in 2020. The subjects were selected using convenience sampling and were classified into intervention and control groups using block randomization. An empowerment program for women workers was conducted across 6 sessions based on an empowerment model. Data collection tools included a demographic questionnaire and the Health Promoting Lifestyle Profile-II, which participants completed both before the program and 8 weeks after the last session. Data analysis was performed in SPSS version 16 using descriptive analysis and inferential statistics. Results: There were no significant differences between the 2 groups in various health-promoting behaviors before the program. However, the intervention group's scores for nutrition (34.92±1.09 vs. 27.87±4.23), physical activity (24.40±2.94 vs. 17.40±5.03), stress management (26.35±2.60 vs. 23.05±4.27), spiritual growth (34.02±3.00 vs. 30.22±5.40), interpersonal relationships (30.82±2.38 vs. 27.60±4.61), and health responsibility (31.60±2.71 vs. 28.22±4.59) were significantly higher than the control group's 8 weeks after the program had ended. Moreover, there was a significant difference in the total score of health-promoting behaviors for the intervention group compared to the control group (179.00±9.22 vs. 151.42±20.25, p=0.001). Conclusions: An empowerment program for women workers led to significant improvements in the health-promoting behaviors of the participants. Similar programs can ultimately improve women's health in the workplace.

Pharmacokinetics of thalidomide in dogs: can feeding affect it? A preliminary study

  • Pierini, Alessio;Sartini, Irene;Giorgi, Mario;Lebkowska-Wieruszewska, Beata;Lisowski, Andrzej;Poapolathep, Amnart;Marchetti, Veronica
    • Journal of Veterinary Science
    • /
    • 제21권5호
    • /
    • pp.60.1-60.11
    • /
    • 2020
  • Background: Tumor-associated neoangiogenesis is a crucial target for antitumor therapies. Thalidomide (TAL) is a promising anti-neoangiogenetic drug that has recently been used in the treatment of several malignancies in dogs. Objectives: The aim of the study was to assess the pharmacokinetics of TAL after single oral administration in dogs. Additionally, the influence of feeding on the pharmacokinetic profile of TAL in dogs has been preliminarily investigated. Methods: Six healthy adult female Labradors were enrolled according to a randomized single-dose, 2-treatment, 2-phase, paired 2 × 2 cross-over study design. The dogs were administered a single 400 mg capsule of TAL in fasted and fed conditions. Blood was collected from 15 min to 48 h after dosing, and TAL quantified in plasma by a validated high-performance liquid chromatography method. The pharmacokinetics of TAL were analyzed using a non-compartmental approach. Results: TAL concentration was quantifiable up to 10 h and 24 h after fasted and fed conditions, respectively. Cmax (fasted, 1.34 ± 0.12 ㎍/mL; fed, 2.47 ± 0.19 ㎍/mL) and Tmax (fasted, 3 h; fed, 10 h) differed substantially between the 2 groups. AUC and t1/2λz were significantly higher in fed (42.46 ± 6.64 mg × h/L; 17.14 ± 4.68 h) compared to fasted (12.38 ± 1.13 mg × h/L; 6.55 ± 1.25 h) dogs. The relative oral bioavailability of TAL for the fasted group was low (36.92% ± 3.28%). Conclusions: Feeding affects the pharmacokinetics of oral TAL in dogs, showing a delayed, but higher absorption with different rate of elimination. These findings are of importance in clinical veterinary settings, and represent a starting point for further related studies.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • 제25권2호
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.

Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures

  • Esra Nur Avukat;Canan Akay;Emre Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권4호
    • /
    • pp.214-226
    • /
    • 2023
  • PURPOSE. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.

DNA Array Analysis of Changes in Gene Expression Profile in DHEA-induced PCO

  • Yu, Jeong-Min;Yoo, Seong-Jin;Kim, Do-Rim;Youm, Mi-Young, Kim, Jee-Yun;Kang, Sung-Goo
    • 한국수정란이식학회:학술대회논문집
    • /
    • 한국수정란이식학회 2002년도 국제심포지엄
    • /
    • pp.112-112
    • /
    • 2002
  • Under normal conditions, women produce a single dominant follicle that participates in a single ovuation each menstrual cycle. But Polycystic ovary syndrome(PCOS) conditions, folliculogenesis does not proceed normally. This condition leads to the accumlation of large numbers of small graffian follicles in which the theca interstitial cells (TIC) produce abnormally large amounts of androgen. PCOS is probably the most common endocrine disorder, affecting women of reprodutive age with 5-10% prevalence estimate. Chronic anovulation, hyperandrogenism, hirsutism, obesity, infertility and polycystic ovaries are clinical hallmarks of women with PCOS. Its etiology remains unknown. To investigate the gene expression pattern of ovary in PCO-induced rat, we used cDNA expression analysis. Total RNA was extracted from the ovary of PCO-induced rat and reverse-transcribed in the presence of[$\alpha$$^{32}$P]-dATP Which were hybridized to Atlas$^{TM}$ Rat Toxicology 1.2 array (Clontech) representing approximately 1176 rat genes. We compared gene expression between ovary of pco-induced immature female rats and control. Differential gene expression profiles were revealed (LIFR-alpha, ADRA1A, Heat shock 90-kDa protein A, PDGFRA). Reverse transcription-polymerase chain reaction(RT-PCR) was used to validate the relative expression pattern obtained by the cDNA array. The precise relationship between the altered expression of genes and PCO is a matter of further investigation. This study was supported by Korea Science and Engineering Foundation(KOSEF)

  • PDF

Effects on hematology and blood biochemistry profile of intramuscular meloxicam injection in Brahminy kite and Barn owl

  • Ratiwan Sitdhibutr;Raveewan Ploypan;Sirawit Subaneg;Chaiyan Kasorndorkbua
    • Journal of Veterinary Science
    • /
    • 제24권3호
    • /
    • pp.43.1-43.8
    • /
    • 2023
  • Background: Meloxicam is used widely for exotic animal analgesia, but its toxicity in common raptor species in Thailand is unclear. Objectives: This study evaluated the single-dose effect of intramuscular meloxicam in common raptor species in Thailand for short-term and long-term periods. Methods: Twenty-two raptors were administered a single 1 mg/kg dose of meloxicam individually via intramuscular injection. The following were evaluated: clinical appearance, body weight, body condition score, body temperature, fecal appearance, complete blood cell count, and biochemistry panel before (day 0) and after the injection (1, 7, and 30 days). The collected samples were categorized into three groups: Brahminy kite (Haliastur indus) (n = 10), adult Barn owl (Tyto javanica) (n = 4), and juvenile Barn owl (n = 8). Results: None of the raptors in the study groups showed any abnormalities. The hematological profiles were significantly different in the short-term period (day 1 and day 7). The creatinine, aspartate aminotransferase, and creatinine kinase increased in several groups. On the other hand, the packed cell volume decreased in the Brahminy kite and juvenile Barn owl groups. According to the findings, an intramuscular injection of 1 mg/kg meloxicam affected the blood biochemistry panel of the muscle, but the affected raptors recovered within one week. Conclusions: An intramuscular injection of meloxicam at a single 1 mg/kg dose in Brahminy kites and Barn owls was not associated with the morbidity, hepatotoxicity, gastrointestinal toxicity, and nephrotoxicity in the short- and long-term periods.

Composition and Diversity of Salivary Microbiome Affected by Sample Collection Method

  • Lee, Yeon-Hee;Hong, Ji-Youn;Lee, Gi-Ja
    • Journal of Oral Medicine and Pain
    • /
    • 제47권1호
    • /
    • pp.10-26
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate whether various saliva collection methods affect the observed salivary microbiome and whether microbiomes of stimulated and unstimulated saliva and plaque differ in richness and diversity. Methods: Seven sampling methods for unstimulated saliva, stimulated saliva, and plaque samples were applied to six orally and systemically healthy participants. Bacterial 16S ribosomal RNA genes of 10 major oral bacterial species, namely, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, Fusobacterium nucleatum, Prevotella intermedia, Prevotella nigrescens, Streptococcus mitis, Streptococcus sobrinus, and Lactobacillus casei, were analyzed by real-time polymerase chain reaction. We comprehensively examined the dependence of the amount of bacterial ribosomal DNA (rDNA), bacterial-community composition, and relative abundance of each species on sample collection methods. Results: There were significant differences in the bacterial rDNA copy number depending on the collection method in three species: F. nucleatum, P. nigrescens, and S. mitis. The species with the highest richness was S. mitis, with the range from 89.31% to 100.00%, followed by F. nucleatum, P. nigrescens, T. denticola, T. forsythia, and P. intermedia, and the sum of the proportions of the remaining five species was less than 1%. The species with the lowest observed richness was P. gingivalis (<0.1%). The Shannon diversity index was the highest in unstimulated saliva collected with a funnel (4.449). The Shannon diversity index was higher in plaque samples (3.623) than in unstimulated (3.171) and stimulated (3.129) saliva and in mouthwash saliva samples (2.061). Conclusions: The oral microbial profile of saliva samples can be affected by sample collection methods, and saliva differs from plaque in the microbiome. An easy and rapid technique for saliva collection is desirable; however, observed microbial-community composition may more accurately reflect the actual microbiome when unstimulated saliva is assayed.

Assessment of the radiant emittance of damaged/contaminated dental light-curing tips by spectrophotometric methods

  • Abdulrahman A. Balhaddad;Isadora Garcia;Fabricio Collares;Cristopher M. Felix;Nisha Ganesh;Qoot Alkabashi;Ward Massei;Howard Strassler;Mary Anne Melo
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.55.1-55.12
    • /
    • 2020
  • Objectives: This study investigated the effects of physically damaged and resin-contaminated tips on radiant emittance, comparing them with new undamaged, non-contaminated tips using 3 pieces of spectrophotometric laboratory equipment. Materials and Methods: Nine tips with damage and/or resin contaminants from actual clinical situations were compared with a new tip without damage or contamination (control group). The radiant emittance was recorded using 3 spectrophotometric methods: a laboratory-grade thermopile, a laboratory-grade integrating sphere, and a portable light collector (checkMARC). Results: A significant difference between the laboratory-grade thermopile and the laboratory-grade integrating sphere was found when the radiant emittance values of the control or damaged/contaminated tips were investigated (p < 0.05), but both methods were comparable to checkMARC (p > 0.05). Regardless of the method used to quantify the light output, the mean radiant emittance values of the damaged/contaminated tips were significantly lower than those of the control (p < 0.05). The beam profile of the damaged/contaminated tips was less homogeneous than that of the control. Conclusions: Damaged/contaminated tips can reduce the radiant emittance output and the homogeneity of the beam, which may affect the energy delivered to composite restorations. The checkMARC spectrophotometer device can be used in dental offices, as it provided values close to those produced by a laboratory-grade integrated sphere spectrophotometer. Dentists should assess the radiant emittance of their light-curing units to ensure optimal curing in photoactivated, resin-based materials.