• 제목/요약/키워드: Clinical ECG

검색결과 174건 처리시간 0.023초

관상동맥 회로술 치험 1예 (Aorto-Coronary Bypass Graft -A Case Report-)

  • 이두연
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.297-305
    • /
    • 1979
  • Occlusive coronary artery disease presents a potential threat to a significant population in the United States. According to many case reports, the increasing incidence of coronary artery disease due to atherosclerosis is noted in Korean, recently. Operative vascular procedures have increased steadily in number over the past 20 years in the United States. There have been many isolated case reports about coronary artery surgery, but these had little clinical impact. Nowadays, major three coronary bypass surgery has developed principally at three cardiac centers in the United States since 1967. Among three coronary bypass operation, the aorta-coronary artery saphenous vein bypass graft was first demonstrated by Favolaro and Effler at the Cleveland Clinic in 1967. We experienced one case of coronary artery disease, which was treated successfully by aorta-coronary saphenous vein graft with mild hypothermia under extracorporeal circulation in May, 1977. Saphenous vein was removed from above the knee and was 2.5 mm in diameter. The left ventricle was not vented for the left ventricle was not overdistended. Temporary artificial pace-maker-Medtronic-was implanted for the prevention and treatment of post-operative arrhythmia and heart block in post-operative first day. He is a 57 year old male businessman who had been suffered from hypertension [200 mmHg in systolic pressure] since 4 years ago, who had intermittent conservative treatment at local clinic. He had been afflicted with severe chest pain with choking sensation for 50 days. This symptom was aggravated exposing cold weather, or cold water, but was respond to rest. Pre-operative ECG revealed no any other ischemic sign except sinus bradycardia. Significant S-T segment depression was noted at lead II, AVF after double 5 minutes exercise, indicating positive Master`s test. Serum cholesterol was slight elevated to 253 mg/dl. Final pre-operative diagnosis was made by coronary arteriogram, which showed about 1.0-cm segmental 90 % occlusive atherosclerotic lesion in the proximal part of right coronary artery above the origin of acute marginal artery. Left coronary artery revealed good patency and there was no collateral circulation between right and left coronary artery .Hospital course was not eventful. He was discharged with good result on the post-operative day. He has been free from chest pain for longer than 2 years. And also the arterial flow in the coronary bypass graft is auscultated with the pocket-sized ultrasonic velocity detector, which shows the patency of the coronary bypass graft good.

  • PDF

동방결절 기능 부전군을 가진 페키니즈 종의 개에 대한 심장 박동수 반응형 영구 심장 박동기의 장착 (Rate-Responsive Permanent Pacemaker Implantation in a Pekingese Dog with a Sick Sinus Syndrome)

  • 한동현;최란;현창백
    • 한국임상수의학회지
    • /
    • 제27권5호
    • /
    • pp.569-572
    • /
    • 2010
  • 간헐적인 기절과 운동 불내성의 주요증상을 호소하는 4살 령의 중성화된 암컷 페키니즈 개 (체중 3.6 kg)가 내원하였다. 신체검사상 지속적인 맥박 결손을 가진 아주 불규칙한 심박동(irregularly irregular heart rhythm)이 나타났다. 12 유도 표면 심전도에서는 동방결절 기능 부전군을 의미하는 간헐적인 방실 접합부 이탈박동과 함께 특이적인 동정지가 나타났다. 본 환자에 대한 심장 박동수 반응형의 양극성 심장 박동조절기(VVIR type)를 이용한 영구적 경정맥형 심박 조율시술은 우심실 내에서 실시되었다. 심장 박동기 장착 이후, 환자의 임상증상은 눈에 띠게 호전되었다. 시술이후 아직까지 기절의 증상은 더 이상 나타나지 않고 있다.

부호화와 정보 엔트로피에 기반한 심방세동 (Atrial Fibrillation: AF) 패턴 분석 (Atrial Fibrillation Pattern Analysis based on Symbolization and Information Entropy)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.1047-1054
    • /
    • 2012
  • 심방세동(Atrial Fibrillation:AF)은 각종 심장질환에서 비교적 빈번히 발생하는 부정맥으로 알려져 있으며, 그 발병률은 연령의 증가와 더불어 점차 증가한다. 전통적으로 심방세동을 검출하는 방법은 시간 영역 분석법과 주파수 영역분석법이 대부분이었다. 하지만 심전도 신호는 잡음의 영향을 많이 받는 환경에서 검출의 정확도가 떨어지며, 시간 주파수 영역 분석법은 RR 간격에 따라 변화하는 불규칙적 리듬에 관한 정보를 정확하게 얻지 못하는 단점이 있다. 본 연구에서는 부호화와 정보 엔트로피에 기반한 AF 패턴 분석 방법을 제안한다. 이를 위해 먼저 RR 간격 데이터를 차분 분할 방식을 통해 부호 서열화 한 후 그 리듬에 대한 패턴을 분석하고 이를 샤논의 정보 엔트로피를 통해 복잡도를 정량화하여 심방세동을 검출하였다. 성능 평가를 위해 10부터 100까지의 문턱값에 따른 엔트로피를 통해 복잡도를 분석하였으며 MIT-BIH 심방세동 데이터베이스를 이용하여 실험하였다.

A Study on the Effect of Basic Life Support Training on the First Responsive Police Officers

  • Jo, Byung-Tae;Kim, Seon-Rye
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권10호
    • /
    • pp.175-182
    • /
    • 2019
  • 이 연구는 경찰관에게 실시한 기본인명소생술 훈련의 효과를 증명하기 위해 실시되었고, 연구대상자는 K 경찰관 중 10명의 실험군과 10명의 대조군으로, 교육프로그램은 60분 이론과 30분 실습을 포함하였다. 기본인명소생술 술기 측정은 미국심장협회에서 제시한 응급 심혈관 치료의 가이드라인을 따랐다. 결과는 다음과 같다. 실험군에서 현장확인기술, 1차 평가수행기술 및 기본인명소생술 능력(심장압박, 인공호흡, 의학적 평가)이 대조군에 비하여 높게 나타났다. 결론적으로, 이 연구결과는 시뮬레이션 교육프로그램이 전통적인 이론실습강의보다 경찰관의 임상술기능력을 향상시키는데 효과적이라는 것을 증명하였다. 그러므로 시뮬레이션 교육프로그램을 심정지 응급치료에 대한 교육프로그램으로 적용하는 것을 제안한다.

In silico evaluation of the acute occlusion effect of coronary artery on cardiac electrophysiology and the body surface potential map

  • Ryu, Ah-Jin;Lee, Kyung Eun;Kwon, Soon-Sung;Shin, Eun-Seok;Shim, Eun Bo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제23권1호
    • /
    • pp.71-79
    • /
    • 2019
  • Body surface potential map, an electric potential distribution on the body torso surface, enables us to infer the electrical activities of the heart. Therefore, observing electric potential projected to the torso surface can be highly useful for diagnosing heart diseases such as coronary occlusion. The BSPM for the heart of a patient show a higher level of sensitivity than 12-lead ECG. Relevant research has been mostly based on clinical statistics obtained from patients, and, therefore, a simulation for a variety of pathological phenomena of the heart is required. In this study, by using computer simulation, a body surface potential map was implemented according to various occlusion locations (distal, mid, proximal occlusion) in the left anterior descending coronary artery. Electrophysiological characteristics of the body surface during the ST segment period were observed and analyzed based on an ST isointegral map. We developed an integrated system that takes into account the cellular to organ levels, and performed simulation regarding the electrophysiological phenomena of the heart that occur during the first 5 minutes (stage 1) and 10 minutes (stage 2) after commencement of coronary occlusion. Subsequently, we calculated the bipolar angle and amplitude of the ST isointegral map, and observed the correlation between the relevant characteristics and the location of coronary occlusion. In the result, in the ventricle model during the stage 1, a wider area of ischemia led to counterclockwise rotation of the bipolar angle; and, during the stage 2, the amplitude increased when the ischemia area exceeded a certain size.

CT를 이용한 심장 기능 검사 (Using CT to Evaluate Cardiac Function)

  • 이종민
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.308-326
    • /
    • 2024
  • 심장 기능의 포괄적인 결과는 심장박출량과 전신 정맥 환류로 표현된다. 심장의 4개의 방실은 각자 고유한 기계적 기능을 가진다. 심장방실과 판막, 폐순환 시스템은 전부하 또는 후부하의 형태로 상호 연관되어 있다. 심장 기능 장애는 전반적인 심장 기능의 실패로 전형적인 임상 증상을 나타낸다. 심장 기능 장애의 근본 원인을 조사하려면 심장 내 혈류 유동 경로에 대한 단계별 평가가 필요하다. 이러한 맥락에서, 심장의 세부 구조를 볼 수 있는 영상검사의 표지자는 심장 기능 평가에 중요한 역할을 한다. 영상기반 평가를 통해 개별 심장 구성 요소의 기능을 단계별로 조사할 수 있다. 심장 기능 평가를 위한 영상검사 중 최근 심장 CT가 포함되고 검증되었다. 본 종설에서는 포괄적 및 단계별 심장 기능 평가를 위한 심장 CT 기반 영상 표지자에 대해 논의하겠다.

심장 관상동맥 외과 (The Clinical Summary of the Coronary Bypass Surgery)

  • 정황규
    • Journal of Chest Surgery
    • /
    • 제13권3호
    • /
    • pp.174-185
    • /
    • 1980
  • It was my great nohour that I can be exposed to such plenty materials of the coronary bypass surgery. Here, I am summarizing the xoronary bypass surgery, clinically. The material is serial 101 patients who underwent coronary bypass surgery between July 17, 1979 to November 30, 1979 in Shadyside Hospital, University of Pittsburgh. 1. Incidence of the Atherosclerosis is frequent in white, male, fiftieth who are living in industrialized country. It has been told the etiologic factor of the atherosclerosis is hereditary, hyperlipidemia, hypertension, smoking, drinking, diabetes, obesity, stress, etc. 2. The main and most frequent complication of the coronary atherosclerosis is angina pectoris. Angina pectoris is the chief cause of coronary bypass surgery and the other causes of coronary bypass surgery are obstruction of the left main coronary artery, unstable angina, papillary muscle disruption or malfunction and ventricular aneurysm complicated by coronary artery disease. 3. The preoperative clinical laboratory examination shows abnormal elevation of plasma lipid in 82 patint, plasma glucose in 40 patient, total CPK-MB in 24 patient stotal LDH in 22 patient out of 101 patient. 4. Abnormal ECG findings in preoperative examine were 29.1% myocardial infarction, 25.8% ischemia and injury, 14.6T conduction defect. 5. Also we had done Echocardiography, Tread Mill Test, Myocardial Scanning, Vectorcardiography and Lung function test to get adjunctive benefit in prediction of prognosis and accurate diagnosis. 6. The frequency of coronary atherosclerosis in main coronary arteries were LAD, RCA and Circumflex in that order. 7. The patients' main complaints which were became as etiologic factor undergoing coronary bypass surgery were angina, dyspnea, diaphoresis, dizziness, nausea and etc. 8. For the coronary bypass surgery, we used cardiopulmonary bypass machine, non-blood, diluting prime, cold cardioplegic solution and moderate cooling for the myocardial protection. 9. We got the grafted veins from Saphenous and Cephalic vein. Reversed and anastomosed between aorta and distal coronary A. using 5-0 and 7-0 prolene continuous suture. Occasionally we used internal mammary A. as an arterial blood source and anastomosed to the distal coronary A. and to side fashion. 10. The average cardiopulmonary bypass time for every graft was 43.9 min. and aortic clamp time was 23 minute. We could Rt. coronary A. bypass surgery only by stand by the cardiopulmonary machine and in the state of pumping heart. 11. Rates by the noumbers of graft were as follow : 21.8% single, 33.7% double, 26.7% triple, 13.9% quadruple, 3% quintuple and 1% was sixtuple graft. 12. combined procedures with coronary bypass surgery were 6% aneurysmectomy, 3% AVR, 1% MVR, 13% pacer implantation and 1% intraaortic ballon setting. 13. We could see the complete abolition of anginal pain after operation in 68% of patient, improvement 25.8%, no change in 3.1%, and there was unknown in 3%. 14. There were 4% immediate postoperative deaths, 13.5% some kinds of heart complication, 51.3% lung complications 33.3% pleural complications as prognosis.

  • PDF

37마리 개의 동맥관 개존증의 임상소견과 비외과적 치료의 회고연구 (Retrospective Study of Patent Ductus Arteriosus in 37 Dogs: Clinical Presentations and Interventional Therapy)

  • 박종인;최란;이승곤;현창백
    • 한국임상수의학회지
    • /
    • 제30권2호
    • /
    • pp.87-94
    • /
    • 2013
  • 본 회고 연구에서는 동맥관 개존증에 이환된 개에서 심장중재술을 통한 치료증례의 임상적 특징과 치료예후를 조사하였다. 환축의 구성을 보면, 말티스와 암컷이 차지하는 비중이 컸다. Bounding pulse와 좌심저부의 심잡음이 가장 대표적인 신체검사 소견이며, differential cyanosis은 매우 드물게 관찰되었다. 심전도상 특징은 좌심종대소견과 동성빈맥이였다. 흉부방사선상 좌심실 종대와 대동맥 확장을 동반한 triple bumps가 대표적인 소견이 였다. 심초음파상 특징은 좌심실 종대를 동반한 폐동맥 단축단면상 심각한 와류 소견이였으며, 다수의 환자에서 이첨판 역류 소견도 관찰되었다. 37증례 중 32증례에서 thromboemolic coils (TCE)이나 Amplatz canine ductal occluder (ACDO)를 이용한 심장 중제술적 치료가 실시되었다. 일시적인 혈색소뇨가 관찰되었고 장착된 코일이나 ACDO가 이탈되는 부작용이 확인되었다. 하지만 장기 관찰이 가능했던 29증례에서 특별한 부작용은 관찰되지 않았다.

수풍순기환(搜風順氣丸)이 내당능장애 환자와 경증 당뇨병환자의 혈당조절에 미치는 영향 (The Hypoglycemic Effect of Supungsunkihwan on Impaired Glucose Tolerance & Mild NIDDM Patiens)

  • 권영구;최기림;이진신;안영민;안세영;두호경;이병철
    • 대한한방내과학회지
    • /
    • 제22권3호
    • /
    • pp.285-290
    • /
    • 2001
  • Purpose : Impaired glucose tolerance (IGT) was standardized in 1979 by the National Diabetes Data Group and the World Health Organization as a risk factor for type 2 diabetes, replacing groups such as 'borderline' and 'chemical' diabetes. The main clinical significance of IGT is as a risk factor for type 2 diabetes and as a risk factor for cardiovascular disease and as a component of the metabolic syndrome. In 1997 the American Diabetes Association(ADA) was proposed the new classification and diagnostic criteria for diabetes, which is strict with the diagnostic baseline of Diabetes from 140mg/dl to 126mg/dl. And it's main purpose is to prevent chronic complications by early diagnosis and treatments. In the oriental medicine, Supungsunkihwan has been used in treatments of Diabetes including IGT & NIDDM, however there is not enough studies about the its objective hypoglycemic effect. so in order to investigate whether there is hypoglycemic effect of Supungsunkihwan, clinical studies were performed with IGT and mild NIDDM patients. Methods : Prior to the study, fasting blood sugar(FBS) and postprandial 2hrs(PP2hrs) glucose were checked. In addition, ECG, cholesterol, TG, HbA1c levels were measured, and the dinical characteristics of patients that can be influence to the blood sugar level such as age, gender, rest type, diet type were surveyed. Supungsukihwan was administered for 7 days, and FBS & PP2hrs were measured again after the therapy. Result : PP2hrs glucose levels were decreased by the administration of Supungsunkihwan. And It's hypoglycemic effects has the correlation with age. That is, the more age increase, the more hypoglycemic effect decrease. Conclusion : Supungsukihwan has hypoglycmic effects on IGT & mild NIDDM patients and it is more effective when administrated to young patients relatively.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF