• Title/Summary/Keyword: Clinical CT

Search Result 1,827, Processing Time 0.021 seconds

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Analysis on Early Detection of Lung Cancer by PET/CT Scan

  • Wang, Huo-Qiang;Zhao, Long;Zhao, Juan;Wang, Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2215-2217
    • /
    • 2015
  • Background: This systemic analysis was conducted to to evaluate the application value of positron emission tomography/computed tomography (PET/CT) in early diagnosis of lung cancer. Methods: Clinical studies evaluating the application value of PET/CT for patients underwent PET/CT imaging. The histological diagnosis served as the standard of truth. Results: Four clinical studies which including 1330 patients with pulmonary spaceoccupying lesions were considered eligible for inclusion. Systemic analysis suggested that, in all 1330 patients, pooled sensitivity was 98.7% (1313.2/1330) and specificity was 58.2%(276.85/476). Conclusion: This systemic analysis suggests that integrated PET/CT imaging provides high sensitivity, and reasonably high specificity, and could be applied for early diagnosis of lung cancer.

Clinical Application of F-18 FDG PET (PET/CT) in Colo-rectal and Anal Cancer (대장-직장 및 항문암에서 F-18 FDG PET (PET/CT)의 임상 이용)

  • Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.52-59
    • /
    • 2008
  • In the management of colo-retal and anal cancer, accurate staging, treatment evaluation, early detection of recurrence are main clinical problems. F-18 FDG PET (PET/CT) has been reported as useful in the management of colo-rectal and anal cancer because that PET has high diagnostic performance comparing to conventional studies. In case of liver metastases, for confirmation of no extrahepatic metastases, in case of high risk of metastasis, for avoiding unnecessary operation, PET (PET/CT) is expected more useful. In anal cancer, PET is expected useful in lymph node staging. For the early prediction of chemotherapy or radiation therapy effect PET has been reported as useful, also. In early detection of recurrence by PET, cost-benefit advantages has been suggested, also. PET/CT is expected to have higher diagnostic performance than PET alone.

THE PET/CT IN THE DIAGNOSIS OF ORAL CANCER: CLINICAL CASES (구강암의 진단에 사용되어지는 PET/CT: 임상 증례)

  • Kim, Sung-Jin;Kim, Yong-Kack;Kim, Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.2
    • /
    • pp.178-182
    • /
    • 2005
  • With the development of systemic diagnostic technique in cancer, the diagnostic methods of head and neck region are developing, also. Now, it is usually used computed tomography(CT), magnetic resornance image(MRI) in head and neck cancer and positron emission tomography(PET) is being increased in diagnostic use because of tumor specificity and accuracy. However, CT and MRI show the advantage of showing precise anatomical landmarks, but the disadvantage of these methods is much affecting by anatomical variations and changes. Otherwise, PET presents the imaging of physiologic and biochemical phenomenon and the disadvantage is the difficult differentiation of normal physiologic uptake, the lack of normal anatomical landmarks. PET/CT, the combination of clinical PET and CT imaging in a single unit is introduced recently, and it helps to get more accurate diagnostic interpretation and to improve in evaluating response to therapy, in management of patients with malignant tumors. So, we report the advantages of PET/CT in the diagnosis of oral cancer with review of literatures.

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

Using MIM Software 3-D PET / CT imaging for the evaluation of radiation therapy on the clinical application of research (MIM 소프트웨어를 이용한 3-D PET/CT 영상의 방사선치료 평가를 위한 임상적용에 관한 연구)

  • Lee, SangHo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.249-255
    • /
    • 2015
  • In this study, through the additional information of the PET / CT images by utilizing the basic data of TPS clinical application on the basis of the image re-forming synthetic function, the True-D technology and MIM software for continued research and development in combination, based on the combination-work between the respective images, reducing the time and cost of useful reading in clinical wide use of image width, efficient, effective tool for tumor targeting at diagnosis and radiation therapy by use as, by using the precise therapeutic effect determination, the time taken to read in the clinical, unnecessary and expect to a can reduce the additional examination by the creation of tumor patients read reports and PACS such asWe expect to be utilized for compatibility development with other software to evaluate the performance of PET / CT equipment.

Changes of Clinical Practice in Gastrointestinal Perforation with the Increasing Use of Computed Tomography

  • Park, Ji-Min;Yoon, Young-Hoon;Horeczko, Timothy;Kaji, Amy Hideko;Lewis, Roger J
    • Journal of Trauma and Injury
    • /
    • v.30 no.2
    • /
    • pp.25-32
    • /
    • 2017
  • Purpose: The use of computed tomography (CT) to evaluate acute abdominal complaints has increased over the past two decades. We investigated how the clinical practice of patients with intestinal perforation has changed with the increasing use of abdominal CT in the emergency department (ED). Methods: We compared ED arrival to CT time, ED arrival to surgical consultation time, and ED arrival to operation time according to the method of diagnosis from 2003-2004 and 2013-2014. Results: In patients with gastrointestinal perforation, time from ED arrival to CT was shorter ($111.4{\pm}66.2min$ vs. $199.0{\pm}97.5min$, p=0.001) but time to surgical consultation was longer ($135.1{\pm}78.8$ vs. $77.9{\pm}123.7$, p=0.006) in 2013-2014 than in 2003-2004. There was no statistically significant difference in time to operation for perforation confirmed either by plain film or CT between the two time periods. There was no statistically significant difference in length of hospital or ICU stay or mortality between the two groups. Conclusion: With the increasing use of abdominal CT in ED, ED arrival to CT time has decreased and ED arrival to surgical consultation time has increased in gastrointestinal perforation. These changes of clinical performance do not delay ED arrival to operation time or adversely influence patient outcome.

A Comprehensive Analysis of Deformable Image Registration Methods for CT Imaging

  • Kang Houn Lee;Young Nam Kang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.303-314
    • /
    • 2023
  • This study aimed to assess the practical feasibility of advanced deformable image registration (DIR) algorithms in radiotherapy by employing two distinct datasets. The first dataset included 14 4D lung CT scans and 31 head and neck CT scans. In the 4D lung CT dataset, we employed the DIR algorithm to register organs at risk and tumors based on respiratory phases. The second dataset comprised pre-, mid-, and post-treatment CT images of the head and neck region, along with organ at risk and tumor delineations. These images underwent registration using the DIR algorithm, and Dice similarity coefficients (DSCs) were compared. In the 4D lung CT dataset, registration accuracy was evaluated for the spinal cord, lung, lung nodules, esophagus, and tumors. The average DSCs for the non-learning-based SyN and NiftyReg algorithms were 0.92±0.07 and 0.88±0.09, respectively. Deep learning methods, namely Voxelmorph, Cyclemorph, and Transmorph, achieved average DSCs of 0.90±0.07, 0.91±0.04, and 0.89±0.05, respectively. For the head and neck CT dataset, the average DSCs for SyN and NiftyReg were 0.82±0.04 and 0.79±0.05, respectively, while Voxelmorph, Cyclemorph, and Transmorph showed average DSCs of 0.80±0.08, 0.78±0.11, and 0.78±0.09, respectively. Additionally, the deep learning DIR algorithms demonstrated faster transformation times compared to other models, including commercial and conventional mathematical algorithms (Voxelmorph: 0.36 sec/images, Cyclemorph: 0.3 sec/images, Transmorph: 5.1 sec/images, SyN: 140 sec/images, NiftyReg: 40.2 sec/images). In conclusion, this study highlights the varying clinical applicability of deep learning-based DIR methods in different anatomical regions. While challenges were encountered in head and neck CT registrations, 4D lung CT registrations exhibited favorable results, indicating the potential for clinical implementation. Further research and development in DIR algorithms tailored to specific anatomical regions are warranted to improve the overall clinical utility of these methods.

Effects of Implementing Artificial Intelligence-Based Computer-Aided Detection for Chest Radiographs in Daily Practice on the Rate of Referral to Chest Computed Tomography in Pulmonology Outpatient Clinic

  • Wonju Hong;Eui Jin Hwang;Chang Min Park;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.890-902
    • /
    • 2023
  • Objective: The clinical impact of artificial intelligence-based computer-aided detection (AI-CAD) beyond diagnostic accuracy remains uncertain. We aimed to investigate the influence of the clinical implementation of AI-CAD for chest radiograph (CR) interpretation in daily practice on the rate of referral for chest computed tomography (CT). Materials and Methods: AI-CAD was implemented in clinical practice at the Seoul National University Hospital. CRs obtained from patients who visited the pulmonology outpatient clinics before (January-December 2019) and after (January-December 2020) implementation were included in this study. After implementation, the referring pulmonologist requested CRs with or without AI-CAD analysis. We conducted multivariable logistic regression analyses to evaluate the associations between using AI-CAD and the following study outcomes: the rate of chest CT referral, defined as request and actual acquisition of chest CT within 30 days after CR acquisition, and the CT referral rates separately for subsequent positive and negative CT results. Multivariable analyses included various covariates such as patient age and sex, time of CR acquisition (before versus after AI-CAD implementation), referring pulmonologist, nature of the CR examination (baseline versus follow-up examination), and radiology reports presence at the time of the pulmonology visit. Results: A total of 28546 CRs from 14565 patients (mean age: 67 years; 7130 males) and 25888 CRs from 12929 patients (mean age: 67 years; 6435 males) before and after AI-CAD implementation were included. The use of AI-CAD was independently associated with increased chest CT referrals (odds ratio [OR], 1.33; P = 0.008) and referrals with subsequent negative chest CT results (OR, 1.46; P = 0.005). Meanwhile, referrals with positive chest CT results were not significantly associated with AI-CAD use (OR, 1.08; P = 0.647). Conclusion: The use of AI-CAD for CR interpretation in pulmonology outpatients was independently associated with an increased frequency of overall referrals for chest CT scans and referrals with subsequent negative results.

The Correlation between CT Images and Pathological Findings in Metastatic Cervical Lymph Nodes (두경부 악성종양에서 경부임파절전이에 대한 CT Scan의 진단적 의의)

  • Lee Won-Sang;Kim Kwang-Moon;Chung Kwang-Hyun;Chang Hoon-Sang;Kim Jee-Woo;Kim Dong-Ik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.4 no.1
    • /
    • pp.5-11
    • /
    • 1988
  • CT examination has been used in the preoperative examination of patients with head and neck cancer. The accuracy of CT in detecting nodal metastases has not been well established. We studied 35 patients (41 neck specimens) with head and neck cancer who underwent neck dissection. Surgical pathologic findings were compared with preoperative CT scan to establish the diagnostic accuracy for cervical lymph node metastases. The results of physical examination, CT scans of neck and histologic examinations were compared each other. The overall diagnostic accuracy of CT was 83.3%. Comparison with clinical accuracy shows the CT scan to be superior to the clinical examination in spite of careful physical examination, particularly in detecting occult metastases.

  • PDF