• Title/Summary/Keyword: Climatic chamber

Search Result 69, Processing Time 0.026 seconds

On the Breeding of “CSR18${\times}$CSR19”- A Robust Bivoltine Hybrid of Silkworm, Bombyx mori L. for the Tropics

  • Kumar, N.Suresh;Basavaraja, H.K.;Kumar, C.M.Kishor;Reddy, N.Mal;Datta, R.K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.5 no.2
    • /
    • pp.153-162
    • /
    • 2002
  • Earlier breeding experiments undertaken at Central Sericultural Research and Training Institute, Mysore, India since a decade had resulted in the development of many productive and qualitatively superior bivoltine hybrids. However, the hot climatic conditions of tropics prevailing particularly in summer are not conducive to rear these high yielding bivoltine hybrids. This has necessitated breeding of compatible bivoltine hybrids for year-round rearing. Accordingly, the Japanese hybrid, B2Ol ${\times}$ BCS12 which was found to be tolerant to high temperature was used as breeding resource material. Following hybridization and selection rearing of silkworms was taken up in SERICATRON (Environmental chamber with precise and automatic control facilities for uniform maintenance of temperature and humidity) at high temperature of $36{\times}1^{\circ}C$ and 85${\times}$5% RH in fifth instar and the control batches at $25{\times}1^{\circ}C$ and 65{\times}$5% RH. Directional selection was resorted to the batches reared at 36$\pm$1$^{\circ}C$ till F$_{5}$ keeping pupation rate as important selection criteria. From $F_{2}% onwards the experiment was modified in such a way as to conduct normal rearing every alternate generation to regain the lost vitality due to continuous exposure to high temperature and high humidity stress. At $F_{2}$ , Oval and dumb-bell cocoons were separated out and designated as CSR18 and CSR19, respectively. By utilizing these lines at $F_{12}$, the hybrid CSR18$\times$CSR19 was prepared and studied for the thermotolerance by subjecting to stress condition at high temperature of 36$\pm$1$^{\circ}C$ and 85$\pm$5% RH in fifth instar and the control batches at $25{\times}1^{\circ}C$ and 65${\times}$5% RH. The better performance of CSR18${\times}$CSR19 (survival > 88%) at $36{\times}1^{\circ}C$ clearly indicates the general superiority of CSR18${\times}$CSR19 with regard to high temperature tolerance over the productive hybrids and CSR18$\times$CSR19 can perform well in varied agro-climatic conditions of the tropics with optimum qualitative and quantitative characteristics.s.

Correlation between blood, physiological and behavioral parameters in beef calves under heat stress

  • Kim, Won Seob;Lee, Jae-Sung;Jeon, Seung Woo;Peng, Dong Qiao;Kim, Young Shin;Bae, Mun Hee;Jo, Yong Ho;Lee, Hong Gu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.6
    • /
    • pp.919-925
    • /
    • 2018
  • Objective: The performance, health, and behaviour of cattle can be strongly affected by climate. The objective of this study was to determine the effect of heat stress on blood parameters, blood proteins (haptoglobin [Hp]; heat shock protein 70 [HSP70]), rectal temperature (RT), heart rate (HR) and rumination time in Korean native beef calves. Methods: Thirty-two Korean native beef calves were randomly assigned to 8 groups with 4 animals per group. They were kept in environmental condition with temperature-humidity index (THI) ranging from 70.01 to 87.72 in temperature-humidity controlled chamber for 7 days. Results: Their HR, RT, and serum cortisol and HSP70 levels were increased (p<0.05) in high THI compared to those at low THI. But, serum Hp level was decreased (p<0.05) in high THI compared to these at low THI. In addition, HR, RT, serum cortisol and HSP70 were positively correlated with THI ($R^2=0.8368$, p<0.01; $R^2=0.6162$, p<0.01; $R^2=0.581$, p<0.01; $R^2=0.2241$, p = 0.0062, respectively). There was also positive association between HR and cortisol ($R^2=0.4697$, p<0.01). Similarly, RT and cortisol were positively associated ($R^2=0.4581$, p<0.01). But, THI and HR were negatively correlated with Hp ($R^2=0.2157$, p = 0.02; $R^2=0.3362$, p = 0.003). Hematology and metabolites results were different among treatment groups. Standing position was higher (p<0.05) in the high THI group compared to that in the low THI group. Conclusion: Based on these results, it can be concluded that HR, RT, blood parameters (Cortisol, HSP70, Hp) and standing position are closely associated with heat stress. These parameters can be consolidated to develop THI chart for Korean native beef calves.

Evaluation of Physiological Responses and Comfort of Protective Clothing Using Charcoal Printing (숯 날염가공한 방호복의 인체생리반응 및 쾌적성 평가)

  • Chung Myung-Hee;Park Soon-Ja;Shin Jung-Sook;Koshiba Tomoko;Tamura Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.981-991
    • /
    • 2006
  • The purpose of this study was to determine the practicability of an experimental protective clothing by identifying the human body's physiological responses to it as well as the human body's comfort level when wearing it, particularly with the use of a processed charcoal material. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric; and one whose inner side made use of a non-woven fabric processed with charcoal with a 10% density. Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climatic chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively, and were measured within a period of 60min, consisting of a 20-min rest period, a 20-min exercise period, and a 20-min recovery period. Based on the results of this study, the efficiency of the processed charcoal material was reviewed, and a database requiring the production of more functional and comfortable protective clothing materials was established.

Study on Atmospheric Corrosion for Two Different Marine Environments in India

  • Saha, Jayanta Kumar
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.120-127
    • /
    • 2007
  • In any developing nation major investment goes for infrastructure and it is not exception in India. Good numbers of buildings, bridges, shopping malls, car parks etc. are coming up with steel for sustainable development. Thus protecting the structures from corrosion are the challenges faced by professionals for all types of steel structures. About 3% of GDP is accounted for loss due to corrosion. To combat this up to date corrosion map is called for as the country has wide variation of climatic zones with vastcoastline. Logically organic paint system can be prescribed based on the corrosion rate on bare steel with respect to environment. Present paper will emphasis on the study conducted on two types of structural steel coated with organic paint located in twomarine environment having been exposed for three years, Test coupons made from steels both bare and coated are deployed at two field stations having marine (Digha) and industrial marine (Channai) environments. Various tests like AC impedance DC corrosion, polarisation, salt spray test, $SO_2$ chamber and Raman spectroscopy were carried out both in laboratory on fresh as well as coupons collected from exposure sites. Rust formed on the bare and scribed coated coupons are investigated. It is found that normal marine environment at Digha exhibits higher corrosion rate than polluted marine environment in Channai. Rust analysis indicates formation of ${\propto}$-FeoOH protects or reduces corrosion rate at Channai and formation of non-protective ${\gamma}$-FeoOH increases corrosion rate at Digha. The slower corrosion rate in Channai than at Digha is attributed due to availability of $SO_2$, in the environment, which converts non‐protective rust ${\gamma}$-FeoOH to protective rust ${\propto}$-FeoOH. While comparing the damage on the coated panels it is found that low alloy structural steel provides less damage than plain carbon steel. From the experimentations a suitable paint system specification is drawn for identical environments for low medium and high durability.

Effects of Hair Style on Human Physiological Response in a Thermal Neutral Environment (쾌적 환경에서 헤어스타일 유형이 인체 생리 반응에 미치는 영향)

  • Kim, Myung-Ju
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.1
    • /
    • pp.117-124
    • /
    • 2010
  • Recently, research on variables associated with hair styles are increasing with the spreading of total coordinated intention in the fields of clothing and cosmetology. In the present study, we focused on examining the skin temperature on the scalp(the vertex, temporal, and occiput), humidity on the occiput, skin temperatures (the forehead, back of ear, back of neck, upper back, abdomen, forearm, hand, thigh, calf, and foot), rectal temperature, total body mass loss by hair styles in a thermal neutral environment. Four young females participated as subjects. For a certain period, each subject had the five different hair styles in a random order: (1)Straight short hair(SS), (2)Perm waved short hair(PS), (3) Straight long hair(SL), (4)Perm waved long hair(PL), (5)Ponytail style(PT). Subjects wore briefs, bra, shirts with long sleeves, long legged training pants, and socks. The environmental variables of a climatic chamber were kept constant at $21{\pm}0.5^{\circ}C$ of air temperature and 55${\pm}$5%RH of air humidity. The results indicated the following: The skin temperature and humidity on the scalp did not show any significant differences among five different hair styles, but straight long hair style(SL)was the highest on the vertex, temporal, and occiput. The temporal skin temperature($29.8\sim30.8^{\circ}C$) was the highest, while the vertex skin temperature($28.7\sim30.1^{\circ}C$) was the lowest. Humidity on the occiput was the highest in the perm waved long hair style(PL). The back of ear skin temperature was significantly lower in the ponytail style(PT) than in the other four hair styles(p<.001). In the straight long hair style(SL), the skin temperature on the back of the neck and on the upper back were significantly higher than those of the other four hair styles(p<.01). Mean skin temperature and rectal temperature had no significant differences among hair styles. Total body mass was the highest in the perm waved long hair style(PL)(p<.05). We acquired fundamental data to enable the improvement of the current hair clinic system, wigs, functional hats, and helmets.

Effects of Covering Parts of Body with Garments on Human Thermoregulation and Sensation(II) (신체의 부위별 피복이 체온조절 및 주관적인 감각에 미치는 영향(II))

  • 이종민
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • In this study the physiological significance of the upper and lower body on thermoregulation and sensation are examined. Experiments were carried out on 4 females in a climatic chamber conditioned at $25\pm1^{circ}C, 50\pm5%$ R.H.. Before the measurements, subjects were exposed to 3 types of enviromental temperature: 1) $25\pm1^{\circ}C$ for 60 min.(ST), 2) $25^{\circ}C$\rightarrow35^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(HT), 3) $25^{\circ}C$\rightarrow15^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(LT) covering the upper body (U) or lower body (L) with garments. 1) $T_{re}$ was significantly higher in L than in U only in 57 condition. $T_{sk}$ and Temp. under the clothing were higher in U than in L in all three conditions. Thermal sensation was warmer in U than in L, and comport sensation was most comfortable in HT condition. 2) When the upper or lower body was covered or exposed, the mean skin temperature of the upper body was higher than that of the lower body. Following covering and uncovering the same area, the changes in skin temperature were greater in the upper body than in lower body, and covering the upper body produced a greater difference of skin temperature between body and lower body than covering the lower body. 3) In all environmental conditions, when the upper body was uncovered, the skin temperatures of the chest, upper arms and forearms dropped to a considerable degree, and when the lower body was uncovered, skin temperatures of the legs showed the same pattern. On the other hand, skin temperature of the thinghs showed only little change in all cases except forehead and back uncovered or covered in two clothing types.

  • PDF

The Effect of Differences between Gal-Ot and Undyed Clothing and clothing Types on Wear Sensation (갈옷과 흰옷 및 그 의복형태의 차가 착용감에 미치는 영향)

  • 박순자;손원교
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.30-41
    • /
    • 1999
  • This study was conducted to verify the advantages of Gal-Ot. Gal-Ot is defined the clothings dyed with persimmon juice. Firstly the physical properties of fabrics were examined. Secondly the wear tests were conducted. The wear tests were performed in climatic chamber controlled 3$0^{\circ}C$ air temperature 50$\pm$5% R.H and 0.2m/s air movement. Four women subjects participated in this experiment and 4 times experiments were performed per one subject. The expeimental schedule was planned following 4 steps that is sedentary posture during 30 minutes-walking the 5。slope treadmill by 70m/min during 20 minutes-sedentary posture during 20 minutes-standing posture on toward the blowing wind during 10 minutes. The results obtained is as folows : The insulation of fabric was increased with dyeing with persimmon juice. The air permeability of fabric was remarkably increased with dyeing with persimmon juice. The mean skin temperatures of subjects were apt to be higher in wearing Gal-Ot than undyed clothing. The clothing micro temperature of subjects were slightly inclined to become lower in wearing Gal-Ot than undyed clothing, The clothing micro humidity was decreasee when: the subjects were gal-Ot than wore undyed clothing, And then it brought about more comfortable on wear sensation. The differences of physiological reactions were not consistent between clothing types except for sweat rate on the back. This result may be attributed the to complex experimental schdules consisted of four steps and to a little difference between open type and close type. However I consider that the clothing type of Gal-Ot is suitable for open type because Gal-Ot is summer wear for blocking the sultry heat.

  • PDF

Assessment of Wear Comfort of Water-vapor-permeable (WVP) garments (투습방수의류의 착용쾌적성 평가)

  • Kang, In-Hyeng;Park, Hyo-Suk;Lee, Han-Sup
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.9
    • /
    • pp.928-939
    • /
    • 2012
  • This study evaluates wear comforts of water-vapor-permeable (WVP) garments through a measurement of various parameters such as skin and rectal temperatures, microclimate between skin and clothing, sweat rate, and subjective sensations (thermal, wet and comfort sensations) to correlate the physiological responses of the human body with its comfort feeling. Wear comfort during a specific exercise on a treadmill in a climatic chamber (temperature T = $20{\pm}0.5^{\circ}C$ and relative humidity H = $50{\pm}10%$) were studied using eight men wearing seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. A comfort sensation was found to be highly correlated with skin T (p<.001), microclimate (T and H) between skin and clothing (p<.001) and sweat rate (p<.05). A regression model correlating comfort sensations and physiological responses obtained from wearer trials could be established: Y = 14.167 - 0.362 ${\times}$ X1 + 0.424 ${\times}$ X2 - 0.238 ${\times}$ X3 - 0.561 ${\times}$ X4 + 0.253 ${\times}$ X5 + 0.214 ${\times}$ X6 - 0.393 ${\times}$ X7 + 0.023 ${\times}$ X8 - 0.043 ${\times}$ X9. (Y = comfort sensation, X1 = forehead skin T, X2 = forearm skin T, X3 = hand skin T, X4 = thigh skin T, X5 = T of chest microclimate, X6 = T of thigh microclimate, X7 = chest sweat rate, X8 = H of back microclimate, X9 = H of thigh microclimate. The regression model obtained in this work can be used by manufacturers to objectively estimate the comfort sensation of sportswear before it is introduced to the consumer market. This study provides salient information to sportswear manufacturers and sportswear consumers.

Physiological Responses of Wearing Industrial Gaiters in a Hot Environment (더운 환경에서 산업용 각반 착용 시 인체생리반응)

  • Choi, Jeong-Wha;Park, Joon-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.7
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

Thermal Physiological Response of Functional Knitwears for Health and Comfort (건강 쾌적 니트의류가 온열생리반응에 미치는 영향)

  • Kang, Mi-Jung;Kwon, Young-Ah;Kim, Tae-Kyu
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1645-1652
    • /
    • 2007
  • The purpose of this study was to evaluate physiological response and subjective sensation of functional knitwears with different materials and designs. The three different types of knitwears were knitted(polar-neck with cotton/chitosan-C, V-neck with cotton/chitosan-CV and polar neck with cotton/chitosan/silver yarn-CS) and evaluated by four healthy female subjects. Eardrum temperature, mean skin temperature, clothing microclimate, and heart rate were measured in climatic chamber($30^{\circ}C$, 50%RH, 0.5m/sec). The results were as follows. 1. Eardrum temperature was generally evaluated as lower in CV and CS than in C. Mean skin temperature was lower in knitwears with silver yarn than in knitwears without silver yarn. 2. Clothing microclimate temperature on the chest was lower in knitwears with silver yarn than in knitwears without silver yarn. 3. Clothing microclimate humidity was generally lower knitwears with silver yarn than knitwears without silver yarn. 4. Heart rate was lower in knitwears with silver yarn than in knitwears without silver yarn and lower in V-neck than in polar neck. 5. Thermal sensation was slightly warmer in knitwears without silver yarn than in knitwears with silver yarn. Overall comfort sensation was evaluated as more comfortable in CV and CS than in C.